• Title/Summary/Keyword: M2 polarization

Search Result 645, Processing Time 0.063 seconds

Effect of Corrosion Atmosphere and Strain Rate on the Stress Corrosion Cracking of High Strength 7xxx Aluminum Alloy (고강도 7xxx 알루미늄 합금의 응력부식균열에 미치는 부식환경과 응력속도의 영향)

  • Yun, Yeo-Wan;Kim, Sang-Ha
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.3
    • /
    • pp.121-128
    • /
    • 2008
  • High strength 7xxx aluminum alloys have been applied to automotive bump back beam of the some limited model for light weight vehicle. The aluminum bump back beam is manufactured through extrusion, bending and welding. The residual stress given on these processes combines with the corrosive atmosphere on the road spreaded with corrosive chemicals to melt snow to occur the stress corrosion cracking. The composition of commercial 7xxx aluminum has Zn/Mg ratio about 3 and Cu over 2 wt% for better strength and stress corrosion cracking resistivity. But this composition isn't adequate for appling to the automotive bump back beam with high resistance to extrusion and bad weldability. In this study the composition of 7xxx aluminum alloy was modified to high Zn/Mg ratio and low Cu content for better extrusion and weldability. To estimate the resistivity against stress corrosion cracking of this aluminum alloy by slow strain rate test, the corrosion atmosphere and strain rate separate the stress corrosion cracking from conventional corrosion must be investigated. Using 0.6 Mol NaCl solution on slow strain rate test the stress corrosion cracking induced fracture was not observed. By adding 0.3% $H_2O_2$ and 0.6M $Na_2SO_4$ to 1M NaCl solution, the corrosion potential and current density of polarization curve moved to active potential and larger current density, and on the slow strain rate test the fracture energy in solution was lower than that in pre-exposure. These mean the stress corrosion cracking induced fracture can be estimated in this 1M NaCl + 0.3% $H_2O_2$ + 0.6M $Na_2SO_4$ solution. When the strain rate was below $2{\times}10^{-6}$, the stress corrosion cracking induced fracture start to be observed.

Induction of heme oxygenase-1 with dietary quercetin reduces obesity-induced hepatic inflammation through macrophage phenotype switching

  • Kim, Chu-Sook;Choi, Hye-Seon;Joe, Yeonsoo;Chung, Hun Taeg;Yu, Rina
    • Nutrition Research and Practice
    • /
    • v.10 no.6
    • /
    • pp.623-628
    • /
    • 2016
  • BACKGROUND/OBJECTIVES: Obesity-induced steatohepatitis accompanied by activated hepatic macrophages/Kupffer cells facilitates the progression of hepatic fibrinogenesis and exacerbates metabolic derangements such as insulin resistance. Heme oxyganase-1 (HO-1) modulates tissue macrophage phenotypes and thus is implicated in protection against inflammatory diseases. Here, we show that the flavonoid quercetin reduces obesity-induced hepatic inflammation by inducing HO-1, which promotes hepatic macrophage polarization in favor of the M2 phenotype. MATERIALS/METHODS: Male C57BL/6 mice were fed a regular diet (RD), high-fat diet (HFD), or HFD supplemented with quercetin (HF+Que, 0.5g/kg diet) for nine weeks. Inflammatory cytokines and macrophage markers were measured by ELISA and RT-PCR, respectively. HO-1 protein was measured by Western blotting. RESULTS: Quercetin supplementation decreased levels of inflammatory cytokines ($TNF{\alpha}$, IL-6) and increased that of the anti-inflammatory cytokine (IL-10) in the livers of HFD-fed mice. This was accompanied by upregulation of M2 macrophage marker genes (Arg-1, Mrc1) and downregulation of M1 macrophage marker genes ($TNF{\alpha}$, NOS2). In co-cultures of lipid-laden hepatocytes and macrophages, treatment with quercetin induced HO-1 in the macrophages, markedly suppressed expression of M1 macrophage marker genes, and reduced release of MCP-1. Moreover, these effects of quercetin were blunted by an HO-1 inhibitor and deficiency of nuclear factor E2-related factor 2 (Nrf2) in macrophages. CONCLUSIONS: Quercetin reduces obesity-induced hepatic inflammation by promoting macrophage phenotype switching. The beneficial effect of quercetin is associated with Nrf2-mediated HO-1 induction. Quercetin may be a useful dietary factor for protecting against obesity-induced steatohepatitis.

A Study on the strees corrosion cracking of the pressed aluminum alloy (알루미늄 합금 압출재(Al 6xxx계)의 응력부식균열(SCC) 거동)

  • Lee, Jeong-Hwa;Gwon, Yu-Hyeon;Kim, Sang-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.217-218
    • /
    • 2009
  • 최근 경량화, 리사이클성, 기기의 소형화, 내환경성 등의 이점을 가지고 있는 알루미늄 합금이 여러 분야서 재인식 되고 있다. 그러나 이런 알루미늄 합금이 부식 환경에 노출 될 경우 음력부식균열이 발생할 수 있게 된다. 이러한 음력부식균열의 발생은 알루미늄의 기계적 특성에 안 좋은 영향을 미치므로 제품의 품질저하, 수명 단축, 효율저하, 재해발생 등 직간접적으로 광범위한 피해를 입게 되기에 부식에 대한 많은 연구가 진행이 되고 있다. 이 중에 고비강도용 알루미늄 압출소재인 Al 6xxx계 합금의 열처리 및 조성 변화에 따른 음력부식 균열의 거동에 대해 연구하였다. 응력부식균열 시험은 SSRT시험으로 많이 하고 있는데, 이 시험은 인장시편을 부식 환경 하에 노출하면서 천천히 일정한 변형속도로 당기는 시험이다. 본 연구에서는 Strain rate를 ${10^{-6}}s^{-1}$ 부식용액은 1M-NaCl + 0.6M-$Na_{2}SO_{4}$ + 0.3%-$H_{2}O_{2}$을 사용하여 시험을 하였다. 그러나 시험에 대한 분석은 Tafel polarization curve, SEM, OMS를 이용하였다.

  • PDF

The Influence of Assay Error Weight on Gentamicin Pharmacokinetics Using the Bayesian and Nonlinear Least Square Regression Analysis in Appendicitis Patients

  • Jin, Pil-Burm
    • Archives of Pharmacal Research
    • /
    • v.28 no.5
    • /
    • pp.598-603
    • /
    • 2005
  • The purpose of this study was to determine the influence of weight with gentamicin assay error on the Bayesian and nonlinear least squares regression analysis in 12 Korean appen dicitis patients. Gentamicin was administered intravenously over 0.5 h every 8 h. Three specimens were collected at 48 h after the first dose from all patients at the following times, just before regularly scheduled infusion, at 0.5 h and 2 h after the end of 0.5 h infusion. Serum gentamicin levels were analyzed by fluorescence polarization immunoassay technique with TDxFLx. The standard deviation (SD) of the assay over its working range had been determined at the serum gentamicin concentrations of 0, 2, 4, 8, 12, and 16 ${\mu}g$/mL in quadruplicate. The polynominal equation of gentamicin assay error was found to be SD (${\mu}g$/mL) = 0.0246-(0.0495C)+ (0.00203C$^2$). There were differences in the influence of weight with gentamicin assay error on pharmacokinetic parameters of gentamicin using the nonlinear least squares regression analysis but there were no differences on the Bayesian analysis. This polynominal equation can be used to improve the precision of fitting of pharmacokinetic models to optimize the process of model simulation both for population and for individualized pharmacokinetic models. The result would be improved dosage regimens and better, safer care of patients receiving gentamicin.

Electrocatalytic Oxidation of HCOOH on an Electrodeposited AuPt Electrode: its Possible Application in Fuel Cells

  • Uhm, Sung-Hyun;Jeon, Hong-Rae;Lee, Jae-Young
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.10-18
    • /
    • 2010
  • Controlled electrodeposition of dendritic nano-structured gold-platinum (AuPt) alloy onto an electrochemically pretreated carbon paper substrate was conducted in an attempt to improve catalyst utilization and to secure an electronic percolation network toward formic acid (FA) fuel cell application. The AuPt catalysts were obtained by potentiostatic deposition. AuPt catalysts synthesized as bimetallic alloys with 60% Au content exhibited the highest catalytic activity towards formic acid electro-oxidation. The origin of this high activity and the role of Au were evaluated, in particular, by XPS analysis. Polarization and stability measurements with 1 mg $cm^{-2}$ AuPt catalyst (only 0.4 mg $cm^{-2}$ Pt) showed 52 mW $cm^{-2}$ and sustainable performance using 3M formic acid and dry air at $40^{\circ}C$.

MOGABA: Monitoring of Gamma-ray Bright AGN with KVN 21-m radio telescopes at 22, 43 and 86GHz

  • Lee, Sang-Sung;Byun, Do-Young;Baek, Junhyu;Han, Myounghee;Yang, Jihae;Sohn, Bong Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.239.2-239.2
    • /
    • 2012
  • We report preliminary results of MOGABA project for monitoring total flux density, linearly polarized flux, and polarization angle at 22, 43 and 86GHz of Gamma-ray bright AGN (Active Galactic Nuclei) with KVN (Korean VLBI Network) 21-m radio telescopes. The project has been conducted in one year since May 2011 with an effective monitoring cycle of 1 week, observing four main objects (3C 454.3, BL Lac, 3C 273, and 3C 279). More objects were included in the source list when they had flared in Gamma-ray. Especially, we included a compact radio source at the Galactic center, SgrA* since Jan. 2012. In this paper, we report the current status of the project and preliminary results for the monitoring observations.

  • PDF

Corrosive Characterisics of 12Cr Alloy Steel and Fatigue Characteristics of the Artificially Degraded 12Cr Alloy Steel (12Cr 합금강의 부식특성 및 인공열화된 12Cr합금강의 피로특성)

  • Jo, Sun-Young;Kim, Chul-Han;Bae, Dong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.6
    • /
    • pp.965-971
    • /
    • 2001
  • To estimate the reliability of 12Cr alloy steel, the material of turbine blade in the steam power plant, Its corrosion susceptibility and fatigue characteristics in NaCl and Na$_2$SO$_4$solution with the difference of concentration and temperature was investigated. The polarization tests recommended in ASTM G5 standard for corrosion susceptibility in the various corrosive solutions was estimated. It showed that the higher temperature, the faster corrosion rates and corrosion rates were the fastest in 3.5 wt.% NaCl and 1M Na$_2$SO$_4$solution. From these results, the degradation conditions were determined in distilled water, 3.5 wt.% NaCl and 1M Na$_2$SO$_4$solution at room temperature, 60$\^{C}$ and 90$\^{C}$ during 3, 6 and 9 months. Its surface had a few pits for long duration. But, it was not susceptible in sulfide and chloride condition of several temperatures. If the degraded 12Cr alloy steel and non-degraded one were compared with fatigue characteristics, Any differences were not found regardless of temperature and degradation period.

Characteristics of PLT Thin Films on MgO Substrates and Fabrication of Infrared Sensor (MgO 기판 위에 올린 PLT 박막의 특성과 적외선 센서의 제작)

  • Cho, Sung-Hyun;Jung, Jae-Mun;Lee, Jae-Gon;Kim, Ki-Wan;Hahm, Sung-Ho;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.188-193
    • /
    • 1997
  • The lanthanum-modified lead titanate (PLT) thin films on (100) cleaved MgO single crystal substrate have been prepared by RF magnetron sputtering method using PbO-rich target with varing La contents. The substrate temperature, working pressure, $Ar/O_{2}$, and RF power density of PLT thin films were $580^{\circ}C$ 10mTorr, 10/1, and $1.7W/cm^{2}$, respectively. In these conditions, the c-axis growth and tetragonality of the PLT thin films decreased for addition of La content and the PLT thin films showed diffuse phase transition from high temperature XRD patterns. The infrared sensor was fabricated. The remanent polarization was above $1.71{\mu}C/cm^{2}$ and the pyroelectric voltage was above 500mV with 10:1 signal to noise ratio.

  • PDF

Effects of Deposition Pressure on the Phase Formation and Electrical Properties of BiFeO3 Films Deposited by Sputtering

  • Park, Sang-Shik
    • Korean Journal of Materials Research
    • /
    • v.19 no.11
    • /
    • pp.601-606
    • /
    • 2009
  • $BiFeO_3$ (BFO) thin films were prepared on $Pt/TiO_2/Si$ substrate by r.f. magnetron sputtering. The effects of deposition pressure on electrical properties were investigated using measurement of dielectric properties, leakage current and polarization. When BFO targets were prepared, Fe atoms were substituted with Mn 0.05% to increase electrical resistivity of films. (Fe+Mn)/Bi ratio of BFO thin films increases with increasing partial pressure of $O_2$ gas. The deposited films showed the only BFO phase at 10 mTorr, the coexistence of BFO and $Bi_2O_3$ phase at 30-50 mTorr, and the only $Bi_2O_3$ phase at 70 mTorr. The crystallinity of BFO films was reduced due to the higher Bi contents and the decrease of surface mobility of atoms at high temperature. The porosity and surface roughness of films increased with the increase of the deposition pressure. The films deposited at high pressure showed low dielectric constant and high leakage current. The dielectric constant of films deposited at various deposition pressures was 84${\sim}$153 at 1 kHz. The leakage current density of the films deposited at 10${\sim}$70 mTorr was about $7{\times}10.6{\sim}1.5{\times}10.2A/cm^2$ at 100 kV/cm. The leakage current was found to be closely related to the morphology and composition of the BFO films. BFO films showed poor P-E hysteresis loops due to high leakage current.

The Limiting Current Density and the Regeneration of a Heterogeneous Ion Exchange Membrane in a Nickel Plating Rinse Waters Treatment Process by Electrodialysis (전기투석에 의한 니켈도금 폐수처리 공정에서 한계전류밀도와 불균질 이온교환막의 재생)

  • 윤용수
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.2
    • /
    • pp.38-46
    • /
    • 2001
  • In this work, the heterogeneous ion exchange membrane was used in a electrodialysis apparatus to treat a Ni planting rinse water because the heterogeneous ion exchange membrane was excellent efficiency as compared with low manufacturing cost, was easy to make, and had a good mechanical properties. For a regeneration of membrane and to obtain the optimal condition for a scale-up of apparatus after treating Ni plating rinse water, we would find about the limiting current density and the concentration polarization. When the Ni plating rinse water 150mg/L was treated with the electrodialysis apparatus using the heterogeneous ion exchange membrane, the limiting current density was about $1.49{\;}mA/\textrm{cm}^2$. And the limiting current density increased with the flow rate and concentration of Ni plating rinse water. We recognized that the used membrane could be reused by periodic backwashing because efficiency was constant when the membrane was backwashed after treating wastewater.

  • PDF