• Title/Summary/Keyword: M152

Search Result 811, Processing Time 0.024 seconds

Development of Pool Boiling Heat Transfer Correlation for Hydrocarbon Refrigerants (탄화수소계 냉매의 풀비등 열전달 상관식 개발)

  • Park Ki-Jung;Baek In-Cheol;Jung Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.247-253
    • /
    • 2006
  • In this work, pool boiling heat transfer coefficients (HTCs) of hydrocarbon refrigerants are measured from a horizontal smooth tube of 19.0 mm outside diameter. Tested pure refrigerants are Propylene, Propane, Isobutane, Butane and Dimethylether (DME). The pool temperature was maintained at saturation temperature of $7^{\circ}C$ and heat flux was varied from $10kW/m^2$ to $80kW/m^2$ with an interval of $10kW/m^2$. Wall temperatures were measured directly by thermocouple hole of 0.5 mm out-diameter, 152 mm long and inserting ungrounded sheathed thermocouples from the side of the tube. Tested results show that HTCs of Propane, Propylene are 2.5%, 10.4% higher than those of R22 while those of Butane and Isobutane are 55.2%, 44.3% lower than those of R22 respectively. For pure refrigerants, new correlation can be applied to all of CFCs, HCFCS, HFCs, as well as hydrocarbons was developed. The mean deviation was 4.6%.

Evaluation on Flexural Behavior of Double-tee Slabs with the Least Depth from Optimization Process (최적이론에 의하여 설계된 최소 깊이 더블티 슬래브의 휨거동 평가)

  • 유승룡;김대훈;유재천
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.141-152
    • /
    • 1999
  • Precast prestressed double-tee slab may be designed by the PCI Design Handbook. It is based on the bridge construction and is required for reorganization for the use of buildings in the domestic construction environments. Much enhanced sections are developed from the reforming process on the determined design factors in the previous experimental works on double tees. Pre-determined shape, reinforcement detail, and 5000 psi concrete strength can not be expected as the best solution for the domestic construction requirements because large amount of use on that systems are anticipated. Flexural tests are performed on four full-scale 12.5m proto-type models, "least depth double tee", which are resulted from the optimization process. Domestic superimposed live load regulation, domestic material properties which is available to product, building design requirements and economy in construction are considered as the main factors to establish. the first two sections are double tee section for 1.2 ton/$\m^2$ market live load with straight and one-point depressed strands and the second two are for 0.6 ton/$\m^2$ parking live load with those strand types. All of the specimens tested fully comply with the flexural strength requirements as specified by ACI 318-95. However, the research has shown that following improved considerations are needed for better result in practice. The locations and method of connection for the lowest bottom mild bar, connection method between precast and cast-in-place concrete, and dap-end reinforcement are need to be improved.

Genetic Structure of Macrophomina phaseolina Populations, the Causal Agent of Sesame Charcoal Rot Disease in Iran

  • Maryam Dolatkhah;Fariba ghaderi;Abdollah Ahmadpour
    • Research in Plant Disease
    • /
    • v.30 no.1
    • /
    • pp.50-59
    • /
    • 2024
  • Charcoal rot disease, caused by the fungus Macrophomina phaseolina, is one of the most important diseases of Sesame (Sesamum indicum) all over the world. However, the population biology of M. phaseolina is poorly understood. In this study, M. phaseolina isolates from five different regions of Iran (Khuzestan, Fars, Bushehr, Hormozgan, and Kohgiluyeh & Boyer-Ahmad provinces) (n=200) were analyzed for genetic variation using inter simple sequence repeats marker. In total, 152 unique haplotypes were identified among the 200 M. phaseolina isolates, and gene diversity (H=0.46-0.84) and genotypic diversity were high in each of the regions. The structure analysis clustered five Iranian populations into two distinct groups, the individuals from group 1 were assigned to the Bushehr population and the individuals from Khuzestan, Fars, Hormozgan and Kohgiluyeh & Boyer-Ahmad were aggregated and formed group 2. The results matched with genetic differentiation and gene flow among regions. Analyses of the distribution of gene diversity within and among five Iranian populations were 61% and 39%, respectively. Our results showed that infected seeds are thought to be the dominant mechanism responsible for the spreading of the pathogen in southern parts of Iran. In summary, it is essential to have local quarantine and prevent seed exchanges between geographical populations to restrict the dispersal of pathogen over long distances and provide certified seeds in Iran.

The Role of Adenosine Receptors on Acetylcholine Release in the Rat Hippocampus (흰쥐 해마에서 Acetylcholine 유리에 미치는 Adenosine 수용체의 역할)

  • Choi, Bong-Kyu;Kim, Do-Kyung
    • The Korean Journal of Pharmacology
    • /
    • v.30 no.2
    • /
    • pp.145-152
    • /
    • 1994
  • As it has been reported that the depolarization induced acetylcholine(ACh) release is modulated by activation of presynaptic $A_1-adenosine$ heteroreceptor and various lines of evidence indicate the $A_2-receptor$ is present In hippocampus, this study was undertaken to delineate the role of adenosine receptors on hippocampal ACh release. Slices from the rat hippocampus were equilibrated with $[^3H]-choline$ and the release of the labelled product, $[^3H]-ACh$, which evoked by electrical stimulation(3 Hz, $5\;Vcm^{-1}$, 2 ms, rectangular pulses) was measured, and the influence of various agents on the evoked tritium outflow was Investigated. Adenosine$(0.3{\sim}100\;{\mu}M)$ and CPA$(0.1{\sim}30\;{\mu}M)$ decreased the $[^3H]-ACh$ release in a dose-dependent manner without changing the basal rate of release. DPCPX$(1{\sim}10\;{\mu}M)$, a selective $A_1-receptor$, antagonist, increased the $[^3H]-ACh$ release in a dose related fashion with slight increase of basal tritium release. And the effects of adenosine and CPA were significantly inhibited by $DPCPX(2\;{\mu}M)$ treatment. CPCA, a specific $A_2-agonist$, in concentration ranging from 0.3 to 30 ${\mu}M$, decreased the evoked tritium outflow, and these effects were also abolished by $DPCPX(2\;{\mu}M)$ treatment. But the CPCA effects were not affected by $DMPX(2\;{\mu}M)$, a specific Aa-antagonist, treatment. However, CGS 21680c, a recently introduced potent $A_2-agonist$, in concentration ranging from 0.1 to $10{\mu}M$, did not alter the evoked tritium outflow. These results indicate that the decrement of the evoked ACh release by adenosine is mediated by $A_1-heteroreceptor$, but $A_2-adenosine$ receptor is not involved in ACh release in the rat hippocampus.

  • PDF

Capacitive Skin Piloerection Sensors for Human Emotional State Cognition (인간의 감정변화 상태 인지를 위한 정전용량형 피부 입모근 수축 감지센서)

  • Kim, Jaemin;Seo, Dae Geon;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.2
    • /
    • pp.147-152
    • /
    • 2015
  • We designed, fabricated, and tested the capacitive microsensors for skin piloerection monitoring. The performance of the skin piloerection monitoring sensor was characterized using the artificial bump, representing human skin goosebump; thus, resulting in the sensitivity of $-0.00252%/{\mu}m$ and the nonlinearity of 25.9 % for the artificial goosebump deformation in the range of $0{\sim}326{\mu}m$. We also verified two successive human skin piloerection having 3.5 s duration on the subject's dorsal forearms, thus resulting in the capacitance change of -6.2 fF and -9.2 fF compared to the initial condition, corresponding to the piloerection intensity of $145{\mu}m$ and $194{\mu}m$, respectively. It was demonstrated experimentally that the proposed sensor is capable to measure the human skin piloerection objectively and quantitatively, thereby suggesting the quantitative evaluation method of the qualitative human emotional state for cognitive human-machine interfaces applications.

Serologic Tests of IgG and IgM Antibodies and IgG Avidity for Diagnosis of Ocular Toxoplasmosis

  • Rahimi-Esboei, Bahman;Zarei, Mohammad;Mohebali, Mehdi;Valian, Hossein Keshavarz;Shojaee, Saeedeh;Mahmoudzadeh, Raziyeh;Salabati, Mirataollah
    • Parasites, Hosts and Diseases
    • /
    • v.56 no.2
    • /
    • pp.147-152
    • /
    • 2018
  • This prospective study was aimed to detect acute and chronic ocular toxoplasmosis by comparison of anti-Toxoplasma gondii IgM and IgG antibody levels and IgG avidity test. One hundred and seventeen patients with ocular toxoplasmosis (OT) who referred to the Farabi Eye Hospital, Tehran, Iran were included in this study. Of the patients, 77 cases were positive for anti-T. gondii IgG, and 8 cases were positive for anti-T. gondii IgM. IgG avidity test revealed 11, 4, and 102 cases were low, intermediate, and high, respectively, and 6.8% and 9.4% of cases were positive for IgM and IgG avidity tests, respectively (P=0.632). Agreement (Kappa value) between paired tests IgG-IgM, IgG-IgG avidity, and IgM-IgG avidity was 0.080, 0.099, and 0.721, respectively (P<0.05). This study showed that conventional serologic tests (IgM and IgG levels) and IgG avidity correlate well each other and can be used to differentiate recent infections from old OT. It seems that reactivated old infections rather than recently acquired infections are majority of Iranian OT patients.

Performance Characteristics of PM10 and PM2.5 Samplers with an Advanced Chamber System (챔버 기술 개발을 통한 PM10과 PM2.5 시료채취기의 수행 특성)

  • Kim, Do-Hyeon;Kim, Seon-Hong;Kim, Ji-Hoon;Cho, Seung-Yeon;Park, Ju-Myon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.8
    • /
    • pp.739-746
    • /
    • 2010
  • The purposes of this study are 1) to develop an advanced chamber system within ${\pm}10%$ of air velocity at the particulate matter (PM) collection area, 2) to research theoretical characteristics of PM10 and PM2.5 samplers, 3) to assess the performance characteristics of PM10 and PM2.5 samplers through chamber experiments. The total six one-hour experiments were conducted using the cornstarch with an mass median aerodynamic diameter (MMAD) of $20\;{\mu}m$ and an geometric standard deviation of 2.0 at the two different air velocity conditions of 0.67 m/s and 2.15 m/s in the chamber. The aerosol samplers used in the present study are one APM PM10 and one PM2.5 samplers accordance with the US federal reference methods and specially designed three mini-volume aerosol samplers (two for PM10 and one for PM2.5). The overall results indicate that PM10 and PM2.5 mini-volume samplers need correction factors of 0.25 and 0.39 respectively when APM PM samplers considered as reference samplers and there is significant difference between two mini-volume aerosol samplers when a two-way analysis of variance is tested using the measured PM10 mass concentrations. The PM10 and PM2.5 samplers with the cutpoints and slopes (PM10: $10{\pm}0.5\;{\mu}m$ and $1.5{\pm}0.1$, PM2.5: $2.5{\pm}0.2\;{\mu}m$ and $1.3{\pm}0.03$) theoretically collect the ranges of 86~114% and 64~152% considering the cornstarch characteristics used in this research. Furthermore, the calculated mass concentrations of PM samplers are higher than the ideal mass concentrations when the airborne MMADs for the cornstarch used are smaller than the cutpoints of PM samplers and the PM samplers collected less PM in another case. The chamber experiment also showed that PM10 and PM2.5 samplers had the bigger collection ranges of 37~158% and 55~149% than the theocratical calculated mass concentration ranges and the relatively similar mass concentration ranges were measured at the air velocity of 2.15 m/s comparing with the 0.67 m/s.

Spatial Distribution Pattern of Chloranthus japonicus Population at Mt. Ahop (아홉산 홀아비꽃대 집단의 공간적 분포 양상)

  • Huh, Man Kyu
    • Journal of Life Science
    • /
    • v.28 no.2
    • /
    • pp.148-152
    • /
    • 2018
  • The patchiness of local environments within a habitat is assumed to be a primary factor affecting the spatial patterns of plants, and a randomization procedure is developed for testing the null hypothesis that only spatial association with patches determined the spatial patterns of plants. Chloranthus japonicus (Chloranthaceae) is an herbaceous perennial and a member of the genus Chloranthus in the family Chloranthaceae. The spatial pattern of C. japonicus was analyzed according to several patchiness indices, population uniformity or aggregation under different sizes of plots by dispersion indices, and spatial autocorrelation. Population densities (D) varied from 0.356 to 2.270, with a mean of 1.527. The values of dispersion indices ( at Mt. Ahop were lower than 1 at six plots ($2m{\times}2m$, $2m{\times}4m$, $4m{\times}4m$, $4m{\times}8m$, $8m{\times}8m$, and $8m{\times}16m$), but the two large plots ($16m{\times}16m$ and $16m{\times}32m$) were higher than 1. Thus, the aggregation indices ( were negative at Mt. Ahop, which indicates a uniform distribution. The two large plots ($16m{\times}16m$ and $16m{\times}32m$) had positive CIs. However, the values were not large (0.009 for the $16m{\times}16m$ plot and 0.038 for the $16m{\times}32m$ plot). The mean crowding ($M^{\ast}$) and patchiness index (PAI) showed positive values for all plots.

Spatial Distribution of Soft Bottom Macrobenthos of Yeoja Bay in Summer Season, South Coast of Korea (여자만 연성저질의 여름철 대형저서동물 공간분포)

  • Lim, Hyun-Sig
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.20 no.2
    • /
    • pp.78-91
    • /
    • 2015
  • Macrobenthic community was studied at 87 stations including intertidal and subtidal area in Yoja Bay, south coast of Korea in summer season of July 2001. Duplicate sediment samples were taken using a van Veen grab ($0.1m^2$) in each station. Mud facies of the sediments were widly distributed in the bay. And relatively high content of sand was shown in the Bulgyo-cheon stream estuary. A total of 274 species was occurred with a mean density of $2,346ind./m^2$ and a mean biomass of $78.2g/m^2$. The polychaetes were species- and density-dominant faunal group with a total of 122 species (44.5% of the total number of species), and mean density of $1,543ind./m^2$ (65.8% of the mean density). Meanwhile, molluscs were biomass-dominant faunal group with $44.4g/m^2$. Bio-Env. analysis showed that the combination of bottom salinity and sand content of the surface sediments was highly correlated to the major macrobenthic communities. The macrobenthic species number, decreasing toward inner bay from mouth of the bay, was significantly correlated to the sediment environmental variables and bottom water salinity. The spatial distribution of abundance showed significant correlation to the sand and mud contents and mean grain size of the surface sediments. Major dominant species were Minuspio japonica (polychaete) with a mean density of $1,167ind./m^2$ at upper part of the bay where salinity was low and Eriopisella sechellensis (amphipod) with $152ind./m^2$ in central part of the bay. Species diversity (H') was $3.0{\leq}$ in the mouth part of the bay and ranged 2.0-3.0 in the inner part of the bay, which showed a significant positive correlation to bottom salinity. Total number of species also showed significant correlations to the sediment composition and bottom salinity. Based on the cluster analysis the macrobenthic community of the bay was classified into five station groups from the bay mouth toward the inner part of the bay depending on the species composition. From the SIMPER analysis Minuspio japonica, Eriopisella sechellensis and Sternaspis scutata mainly contributed to the classification of station group. These results suggested that the macrobenthic communities of the bay were mainly influenced by bottom salinity together with sediment composition, and that the studies of spatial distributions of major dominant species and benthic communities should be conducted continuously to monitor the Yeoja Bay benthic environment.

A fouling mitigation device for a wastewater heat recovery heat pump system using a bubbling fluidized bed with cleaning sponge balls (버블 유동층과 세정 볼을 이용한 폐수 열원 히트펌프 시스템 증발기의 관 외측 오염 저감 장치에 관한 연구)

  • Kim, Jong-Soo;Kim, Do-Bin;Kim, Jun-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.152-156
    • /
    • 2016
  • Wastewater heat recovery heat pump systems use heated wastewater from public baths or factories as the heat pump's heat source. Generally, this system uses a bare tube evaporator. In the heat transfer process from wastewater to refrigerant, thermal resistance is caused primarily by fouling deposits on the outside surface of tube. Fouling directly increases thermal resistance and decreases heat pump efficiency. Thus, it is desirable to eliminate fouling. In this study, we fabricated a fouling mitigation device using a bubbling fluidized bed with cleaning sponge balls in the wastewater bath. Experimental conditions were as follows: $20^{\circ}C$ cold-water temperature, $40^{\circ}C$ wastewater temperature, 100 L/h cold water flow rate, and $0.161m^2$ heat exchanger surface area. Experimental results showed that the thermal resistance of fouling decreased by 56% with the fluidized bed alone and by 86% with both the fluidized bed and cleaning sponge balls.