• Title/Summary/Keyword: M.T.T.F.

Search Result 1,616, Processing Time 0.027 seconds

The Effect of 131I Therapy by Taking in Laxatives (방사성요오드 치료 시 완하제 투여 효과)

  • Kil, Sang-Hyeong;LEE, Hyo-Yeong;Park, Kwang-Yeol;Jo, Kyung-Nam;Baek, Seung-Jo;Hwang, Kyo-Min;Cho, Seong-Mook;Choi, Jae-Hyeok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.3-9
    • /
    • 2014
  • Purpose: Our goals were to evaluate the effect of high dose radioiodine treatment for thyroid cancer by taking in laxatives. Materials and Methods: Twenty patients(M:F=13:7, age $46.3{\pm}8.1\;yrs$) who underwent high dose radioiodine treatment were seperated into Group 1 taking $^{131}I$ 5,500 MBq and Group 2 with the use of laxatives after taking $^{131}I$ 5,500 MBq. The whole body was scanned 16 hours and 40 hours after taking radioactive iodines by using gamma camera, the ROIs were drawn on the gastro-intestinal tract and thigh for calculation of reduction ratio. At particular time during hospitalization, the radioactivity remaining in the body was measured in 1 meter from patient by using survey meter (RadEye-G10, Thermo Fisher Scientific, USA). Schematic presentation of an Origin 8.5.1 software was used for spatial dose rate. Statistical comparison between groups were done using independent samples t-test. P value less than 0.05 was regarded as statistically significant. Results: The reduction ratio in gastro-intestinal 16 hours and 40 hours after taking laxatives is $42.1{\pm}6.3%$ in Group 1 and $72.1{\pm}6.4%$ in Group 2. The spatial dose rate measured when discharging from hospital was $23.8{\pm}6.7{\mu}Sv/h$ in Group 1 and $8.2{\pm}2.4{\mu}Sv/h$ in Group 2. The radioactivity remaining in the body is much decreased at the patient with laxatives(P<0.05). Conclusion: The use in combination with laxatives is helpful for decreasing radioactivity remaining in the body. The radioactive contamination could be decreased at marginal individuals from patients.

  • PDF

A Combat Effectiveness Evaluation Algorithm Considering Technical and Human Factors in C4I System (NCW 환경에서 C4I 체계 전투력 상승효과 평가 알고리즘 : 기술 및 인적 요소 고려)

  • Jung, Whan-Sik;Park, Gun-Woo;Lee, Jae-Yeong;Lee, Sang-Hoon
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.2
    • /
    • pp.55-72
    • /
    • 2010
  • Recently, the battlefield environment has changed from platform-centric warfare(PCW) which focuses on maneuvering forces into network-centric warfare(NCW) which is based on the connectivity of each asset through the warfare information system as information technology increases. In particular, C4I(Command, Control, Communication, Computer and Intelligence) system can be an important factor in achieving NCW. It is generally used to provide direction across distributed forces and status feedback from thoseforces. It can provide the important information, more quickly and in the correct format to the friendly units. And it can achieve the information superiority through SA(Situational Awareness). Most of the advanced countries have been developed and already applied these systems in military operations. Therefore, ROK forces also have been developing C4I systems such as KJCCS(Korea Joint Command Control System). And, ours are increasing the budgets in the establishment of warfare information systems. However, it is difficult to evaluate the C4I effectiveness properly by deficiency of methods. We need to develop a new combat effectiveness evaluation method that is suitable for NCW. Existing evaluation methods lay disproportionate emphasis on technical factors with leaving something to be desired in human factors. Therefore, it is necessary to consider technical and human factors to evaluate combat effectiveness. In this study, we proposed a new Combat Effectiveness evaluation algorithm called E-TechMan(A Combat Effectiveness Evaluation Algorithm Considering Technical and Human Factors in C4I System). This algorithm uses the rule of Newton's second law($F=(m{\Delta}{\upsilon})/{\Delta}t{\Rightarrow}\frac{V{\upsilon}I}{T}{\times}C$). Five factors considered in combat effectiveness evaluation are network power(M), movement velocity(v), information accuracy(I), command and control time(T) and collaboration level(C). Previous researches did not consider the value of the node and arc in evaluating the network power after the C4I system has been established. In addition, collaboration level which could be a major factor in combat effectiveness was not considered. E-TechMan algorithm is applied to JFOS-K(Joint Fire Operating System-Korea) system that can connect KJCCS of Korea armed forces with JADOCS(Joint Automated Deep Operations Coordination System) of U.S. armed forces and achieve sensor to shooter system in real time in JCS(Joint Chiefs of Staff) level. We compared the result of evaluation of Combat Effectiveness by E-TechMan with those by other algorithms(e.g., C2 Theory, Newton's second Law). We can evaluate combat effectiveness more effectively and substantially by E-TechMan algorithm. This study is meaningful because we improved the description level of reality in calculation of combat effectiveness in C4I system. Part 2 will describe the changes of war paradigm and the previous combat effectiveness evaluation methods such as C2 theory while Part 3 will explain E-TechMan algorithm specifically. Part 4 will present the application to JFOS-K and analyze the result with other algorithms. Part 5 is the conclusions provided in the final part.

Purification and properties of inulin fructotransferase (Depolymerizing) from Enterobacter sp. S45 (Enterobacter sp. S45 생산 inulin fructotransferase의 정제 및 특성)

  • Kang, Su-Il;Kim, Su-Il
    • Applied Biological Chemistry
    • /
    • v.36 no.2
    • /
    • pp.105-110
    • /
    • 1993
  • Inulin fructotransferase from Enterobacter sp. S45 was purified with DEAE-cellulose column chromatography and fast protein liquid chromatography. The purified enzyme gave a single band on polyacrylamide gel electrophoresis. The molecular weight was estimated to be 42,800 by SDS-polyacrylamide gel electrophoresis. The optimal pH and temperature for the enzyme reaction were pH 5.5 and $55^{\circ}C$, respectively. $Mg^{2+}$ activated the enzyme activity, but $Fe^{3+}$, $Cu^{2+}$, $Hg^{2+}$ significantly inhibited. After exhaustive digestion of inulin by the enzyme, DFA III, sucrose, 1-kestose and nystose were produced. Sucrose, 1-kestose, raffinose and melezitose can't be used as substrates by the enzyme, but nystose and 1-F-fructofuranosyl nystose were hydrolysed. The Km and Vmax for inulin of the enzyme were 1.4 mM and $0.196\;{\mu}mole/min$, respectively.

  • PDF

Serial $^{99m}Tc$-HMPAO Brain SPECT for Assessing Perfusion Improvement after EDAS in Moyamoya Patients (모야모야병에서 EDAS 수술효과의 평가를 위한 수술전후 $^{99m}Tc$-HMPAO SPECT의 유용성)

  • Lee, Kyung-Han;Lee, Sang-Hyung;Yeo, Jeong-Seok;Kwark, Chul-Eun;Chung, June-Key;Lee, Myoung-Chul;Cho, Byoung-Kyu;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.22-30
    • /
    • 1994
  • Encephalo-duro-arterio-synangiosis (EDAS) is a relatively new surgical procedure for treatment of childhood moyamoya disease. We assessed regional cerebral perfusion in moyamoya patients before (1.3 mo) and after (6.8 mo) EDAS with $^{99m}Tc$-HMPAO brain SPECT. A total of 21 EDAS operations in 17 moyamoya patients was included. Preoperative CT or MRI showed cerebral infarction in 14 patients and carotid angiography showed Suzuki grade I to V stenosis in 6%, 9%, 62%, 12% and 12% of the hemispheres respectively. Preoperative SPECT showed regional hypoperfusion in all patients, bilateral frontal and temporal lobes being the most frequently involved site. $4{\times}4$ pixel sized ROIs were applied on the frontotemporal cortex in 3 slice averaged transverse tomographic images. An index of regional perfusion was measured as: PI (%)=average F-T activity/average cerebellar activity${\times}100$ Pre-EDAS ipsilateral PI ranged from 23.7 to 98.4% (mean: $74.3{\pm}17%$) and increased significantly after operation ($81.4{\pm}17%$, p<0.001). Individual post-EDAS PI improved in 15/21 cases, showed no significant change in 5 and was slightly aggravated in 1. The amount of clinical improvement (${\Delta}CI$) was graded with a scale of 0 to 4 based on frequency and severity of TIA attacks. When patients were grouped according to pre-EDAS PI, group II (PI 70-89) showed a significantly higher ${\Delta}CI$ (3.3) compared to group I (PI< 70, 1.57) or group III (PI >90, 0.5) (P< 0.001). The amount of perfusion improvement (${\Delta}PI$) showed significant correlation with ${\Delta}CI$ (r=0.42, p=0.04). ${\Delta}PI$ did not, however, correlate with the amount of neovascularization assessed angiographically in 8 patients. Serial HMPAO SPECT is an useful noninvasive study for assessing perfusion improvement after EDAS in childhood moyamoya patients.

  • PDF

A New Record of Tarsonemid Mite, Stenotarsonemus spinki (Acari, Tarsonemidae) and Its Damage on Rice in Korea (한국 미기록 벼먼지응애, Steneotarsonemus spinki와 그 피해)

  • 조명래;김덕수;임대준;나승용;임명순
    • Korean journal of applied entomology
    • /
    • v.38 no.2
    • /
    • pp.157-164
    • /
    • 1999
  • A tarsonemid mite. Stet~rotc~r.sot~rrrs~puin.sk i Smiley 1967. is an important rice pest in major rice producing countries of Thailand. Philippine. China, and Taiwan. S. spinki was found first time in Korea from rice grown in environment controlled greenhouse. Rice fed by the mite showed damage symptoms of deformed panicles and inflorescence, lesions on the inner surface of leaf sheath, and browning of rice hulls. Females of S. .spi~lkwi as 263.0 pni (246.5-284.6f 12.2) in body length and 92.4 pm (79.5- 104.9 t 7.6) in body width. Body was elongate and broadest in region of hysterosoma. Body color was pale brown. Legs were robust except for the legs IV which were typical tarsonemid female legs terminating in a whiplike seta two times the length of the leg. Male of S. spir~kiw as 196.5 pm ( 176.5-222.8 + 15.8) in body length and 109.3 ym (98.6- 1 17.7 + 6.4) in body width. Anterior ends of apodemes 111 were extended further than apodemes IV. Femur IV had large inner median lateral flange. and inner anterior and outer median setae were short about equal length. Tarsal claw was stout and curved ventrally.

  • PDF

Low-Temperature Crystallization of Amorphous Si Films by Cu Adsorption (구리 흡착에 의한 비정질 실리콘 박막의 저온 결정화 거동)

  • Jo, Seong-U;Son, Dong-Gyun;Lee, Jae-Sin;An, Byeong-Tae
    • Korean Journal of Materials Research
    • /
    • v.7 no.3
    • /
    • pp.188-195
    • /
    • 1997
  • Copper ions were adsorbed on amorphous Si films by spincoating of Cu solutions and were employed as surface nucleation sites for low-temperature crystallization. The crystallization temperature can bc lo~vered down to $500^{\circ}C$ and rhe crystallization time can be shortened by Cu adsorption. The Cu-adsorbed amorphous films were crystallized by fractal growth with the shape of tree branches. The fractal size ranged from $30 to 300{\mu}m$, depending on the Cu solution concentration. The fractals consisted of f e a t h e r like elliptical grains with the size of $0.3~0.4{\mu}m$. which was comparable to that of the intrinsic films crystallized at $600^{\circ}C$. Both the nucleation activation energy and grotvth activation energy decreased as the Cu concentration in the solution increased. The results suggest thcit the adsorbed Cu increases preferred nucleation sites at the surface and enhmces crystallization by reducing thc activation energies of nucleation and growth.

  • PDF

Experimental study on the tension of cables and motion of tunnel element for an immersed tunnel element under wind, current and wave

  • Wu, Hao;Rheem, Chang-Kyu;Chen, Wei;Xu, Shuangxi;Wu, Weiguo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.889-901
    • /
    • 2021
  • The tension of cables and motion response significantly affect safety of an immersed tunnel element in the immersion process. To investigate those, a hydrodynamic scale-model test was carried out and the model experiments was conducted under wind, current and wave loads simultaneously. The immersion standby (the process that the position of the immersed tunnel element should be located before the immersion process) and immersion process conditions have been conducted and illustrated. At the immersion standby conditions, the maximum force of the cables and motion is much larger at the side of incoming wind, wave and current, the maximum force of Element-6 (6 cables directly tie on the element) is larger than for Pontoon-8 (8 cables tie on pontoon of the element), and the flexible connection can reduce the maximum force of the mooring cables and motion of element (i.e. sway is expecting to decrease approximate 40%). The maximum force of the mooring cables increases with the increase of current speed, wave height, and water depth. The motion of immersed tunnel element increases with increase of wave height and water depth, and the current speed had little effect on it. At the immersion process condition, the maximum force of the cables decrease with the increase of immersion depth, and dramatically increase with the increase of wave height (i.e. the tension of cable F4 of pontoons at wave height of 1.5 m (83.3t) is approximately four times that at wave height of 0.8 m). The current speed has no much effect on the maximum force of the cables. The weight has little effect on the maximum force of the mooring cables, and the maximum force of hoisting cables increase with the increase of weight. The maximum value of six-freedom motion amplitude of the immersed tunnel element decreases with the increase of immersion depth, increase with the increase of current speed and wave height (i.e. the roll motion at wave height of 1.5 m is two times that at wave height of 0.8 m). The weight has little effect on the maximum motion amplitude of the immersed tunnel element. The results are significant for the immersion safety of element in engineering practical construction process.

Efficient Anti-Tumor Immunotherapy Using Tumor Epitope-Coated Biodegradable Nanoparticles Combined With Polyinosinic-Polycytidylic Acid and an Anti-PD1 Monoclonal Antibody

  • Sang-Hyun Kim;Ji-Hyun Park;Sun-Jae Lee;Hee-Sung Lee;Jae-Kyung Jung;Young-Ran Lee;Hyun-Il Cho;Jeong-Ki Kim;Kyungjae Kim;Chan-Su Park;Chong-Kil Lee
    • IMMUNE NETWORK
    • /
    • v.22 no.5
    • /
    • pp.42.1-42.20
    • /
    • 2022
  • Vaccination with tumor peptide epitopes associated with MHC class I molecules is an attractive approach directed at inducing tumor-specific CTLs. However, challenges remain in improving the therapeutic efficacy of peptide epitope vaccines, including the low immunogenicity of peptide epitopes and insufficient stimulation of innate immune components in vivo. To overcome this, we aimed to develop and test an innovative strategy that elicits potent CTL responses against tumor epitopes. The essential feature of this strategy is vaccination using tumor epitope-loaded nanoparticles (NPs) in combination with polyinosinic-polycytidylic acid (poly-IC) and anti-PD1 mAb. Carboxylated NPs were prepared using poly(lactic-co-glycolic acid) and poly(ethylene/maleic anhydride), covalently conjugated with anti-H-2Kb mAbs, and then attached to H-2Kb molecules isolated from the tumor mass (H-2b). Native peptides associated with the H-2Kb molecules of H-2Kb-attached NPs were exchanged with tumor peptide epitopes. Tumor peptide epitope-loaded NPs efficiently induced tumor-specific CTLs when used to immunize tumor-bearing mice as well as normal mice. This activity of the NPs significantly was increased when co-administered with poly-IC. Accordingly, the NPs exerted significant anti-tumor effects in mice implanted with EG7-OVA thymoma or B16-F10 melanoma, and the anti-tumor activity of the NPs was significantly increased when applied in combination with poly-IC. The most potent anti-tumor activity was observed when the NPs were co-administered with both poly-IC and anti-PD1 mAb. Immunization with tumor epitope-loaded NPs in combination with poly-IC and anti-PD1 mAb in tumor-bearing mice can be a powerful means to induce tumor-specific CTLs with therapeutic anti-tumor activity.

A Study on the Use of Active Protocol Using the Change of Pitch and Rotation Time in PET/CT (PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구)

  • Jang, Eui Sun;Kwak, In Suk;Park, Sun Myung;Choi, Choon Ki;Lee, Hyuk;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.67-71
    • /
    • 2013
  • Purpose: The Change of CT exposure condition have a effect on image quality and patient exposure dose. In this study, we evaluated effect CT image quality and SUV when CT parameters (Pitch, Rotation time) were changed. Materials and Methods: Discovery Ste (GE, USA) was used as a PET/CT scanner. Using GE QA Phantom and AAPM CT Performance Phantom for evaluate Noise of CT image. Images are acquired by using 24 combinations that four stages pitch (0.562, 0.938, 1.375, 1.75:1) and six stages X-ray tube rotation time (0.5s-1.0s). PET images are acquired using 1994 NEMA PET Phantom ($^{18}F-FDG$ 5.3 kBq/mL, 2.5 min/frame). For noise test, noise are evaluated by standard deviation of each image's CT numbers. And then we used expectation noise according to change of DLP (Dose Length Product) to experimental noise ratio for index of effectiveness. For spatial resolution test, we confirmed that it is possible to identify to 1.0 mm size of the holes at the AAPM CT Performance Phantom. Finally we evaluated each 24 image's SUV. Results: Noise efficiency were 1.00, 1.03, 1.01, 0.96 and 1.00, 1.04, 1.02, 0.97 when pitch changes at the QA Phantom and AAPM Phantom. In case of X-ray tube rotation time changes, 0.99, 1.02, 1.00, 1.00, 0.99, 0.99 and 1.01, 1.01, 0.99, 1.01, 1.01, 1.01 at the QA Phantom and AAPM Phantom. We could identify 1.0 mm size of the holes all 24 images. Also, there were no significant change of SUV and all image's average SUV were 1.1. Conclusion: 1.75:1 pitch is the most effective value at the CT image evaluation according to pitch change and It doesn't affect to the spatial resolution and SUV. However, the change of rotation time doesn't affect anything. So, we recommend to use the effective pitch like 1.75:1 and adequate X-ray tube rotation time according to patient size.

  • PDF

Clinical Usefulness of PET-MRI in Lymph Node Metastasis Evaluation of Head and Neck Cancer (두경부암 림프절 전이 평가에서 PET-MRI의 임상적 유용성)

  • Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.26-32
    • /
    • 2014
  • Purpose: As PET-MRI which has excellent soft tissue contrast is developed as integration system, many researches about clinical application are being conducted by comparing with existing display equipments. Because PET-MRI is actively used for head and neck cancer diagnosis in our hospital, lymph node metastasis before the patient's surgery was diagnosed and clinical usefulness of head and neck cancer PET-MRI scan was evaluated using pathological opinions and idiopathy surrounding tissue metastasis evaluation method. Materials and Methods: Targeting 100 head and neck cancer patients in SNUH from January to August in 2013. $^{18}F-FDG$ (5.18 MBq/kg) was intravenous injected and after 60 min of rest, torso (body TIM coil, Vibe-Dixon) and dedication (head-neck TIM coil, UTE, Dotarem injection) scans were conducted using $Bio-graph^{TM}$ mMR 3T (SIEMENS, Munich). Data were reorganized using iterative reconstruction and lymph node metastasis was read with Syngo.Via workstation. Subsequently, pathological observations and diagnosis before-and-after surgery were examined with integrated medical information system (EMR, best-care) in SNUH. Patient's diagnostic information was entered in each category of $2{\times}2$ decision matrix and was classified into true positive (TP), true negative (TN), false positive (FP) and false negative (FN). Based on these classified test results, sensitivity, specificity, accuracy, false negative and false positive rate were calculated. Results: In PET-MRI scan results of head and neck cancer patients, positive and negative cases of lymph node metastasis were 49 and 51 cases respectively and positive and negative lymph node metastasis through before-and-after surgery pathological results were 46 and 54 cases respectively. In both tests, TP which received positive lymph node metastasis were analyzed as 34 cases, FP which received positive lymph node metastasis in PET-MRI scan but received negative lymph node metastasis in pathological test were 4 cases, FN which received negative lymph node metastasis but received positive lymph node metastasis in pathological test was 1 case, and TN which received negative lymph node metastasis in both two tests were 50 cases. Based on these data, sensitivity in PET-MRI scan of head and neck cancer patient was identified to be 97.8%, specificity was 92.5%, accuracy was 95%, FN rate was 2.1% and FP rate was 7.00% respectively. Conclusion: PET-MRI which can apply the acquired functional information using high tissue contrast and various sequences was considered to be useful in determining the weapons before-and-after surgery in head and neck cancer diagnosis or in the evaluation of recurrence and remote detection of metastasis and uncertain idiopathy cervical lymph node metastasis. Additionally, clinical usefulness of PET-MRI through pathological test and integrated diagnosis and follow-up scan was considered to be sufficient as a standard diagnosis scan of head and neck cancer, and additional researches about the development of optimum MR sequence and clinical application are required.

  • PDF