• Title/Summary/Keyword: M-pass

Search Result 736, Processing Time 0.035 seconds

Water Transport during the Single-pass Perfusion Experiments : Effects of Some Perfusates and Their Osmolality (일회통과 관류실험시 물의 수송 : 관류액의 종류와 삼투압의 영향)

  • 이정화;이현주;용철순;오두만
    • YAKHAK HOEJI
    • /
    • v.39 no.4
    • /
    • pp.411-416
    • /
    • 1995
  • The single-pass perfusion experiments were performed in anesthetized rats to investigate the effects of perfusates and their osmolality on the water transport and to determine the correlation between the extent of water transport and the volume change of perfusate. Phenol red was used as a nonabsorbable marker. In normal rats, when perfused at a flow rate of 0.5 ml/min, 2-(N-rnorpholino) ethanesulfonic acid (MES) and S$\phi$rensen's phosphate buffers showed minimal net water transport as 0.125 and 0.173 %/cm of intestinal length, respectively. Hypotonic perfusate of 200 mOsm/kg of water and hypertonic perfusate of 400 mOsm/kg of water generated significant water transport compared with isotonic perfusate of 300 mOsm/kg of water. There was a linear correlation between the extent of water transport and the volume change of perfusate, suggesting that the volume change can be used as a measure of water transport.

  • PDF

Analysis of Frequency of Seismogenic Ionospheric Disturbance by using GNSS Signal (GNSS 신호를 이용한 지진에 의한 전리층 교란의 주파수 분석)

  • Kim, Bu-gyeom;Kang, Seon-ho;Han, Deok-hwa;Song, June-sol;Kee, Chang-don
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.616-622
    • /
    • 2018
  • Energy which is released by a huge earthquake can reach the ionosphere and induce disturbances. Those disturbances can detected by analyzing the global navigation satellite system (GNSS) satellite's signal. For detecting those disturbances, band-pass filter is generally used. Therefore, it is important to select proper pass band that can contain disturbance's frequency. In this paper, we analyzed a frequency of the ionospheric disturbances which are induced by earthquake by using GNSS signal. For analyzing seismogenic ionospheric disturbances, we calculated a geometry free combination of carrier phase to obtain a ionospheric delay. After that, the fast Fourier transform was applied to the 1 mHz high-passed ionospheric delay. As a result of analyzing disturbances, the frequency band of earlier disturbances was 4.5 mHz~11mHz and the representative frequency was 5.7 mHz. The frequency band of subsequent disturbances was 6 mHz~10 mHz and the representative frequency was 7.3 mHz.

An Experimental Study of Operating Characteristics on Fouling Auto Removal Apparatus of Multi Pass Type Heat Exchanger using Ejector (이젝터를 이용한 다관식 열교환기 파울링 자동제거장치의 구동특성에 관한 실험적 연구)

  • Kim, J.D.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.63-69
    • /
    • 2009
  • The experiment was performed to check operating characteristics of fouling auto removal apparatus for multi pass type heat exchanger using ejector. The results showed as following. The ejector suction flow rate increased with the head of operating pump of ejector. Proper suction flow rate showed $7.2{\sim}10.2m^3/h$ for ball collection in case of pump head 35~50m. The head of ejector outlet pipe is below 4.1m in case of 40m, the head of operating pump of ejector to confirm ejector suction flow rate 8.4m3/h. Lattice space of ball separator is allowed 6~10.3mm in ranges of ball diameter are 15~25mm and when mass flow of cooling water is 3.0m/sec. Average of passing time of balls is 1.2~2.8sec depend on the velocity of flow and the size of balls.

  • PDF

Three-staged amplifier properties of single-short pulsed distributed feedback dye laser using a XeCl laser (XeCl 레이저를 이용한 단일 단펄스 분포궤한 색소레이저의 3단 증폭기 특성)

  • 김성훈;이영우;김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.424-429
    • /
    • 1999
  • The amplifier properties of single distributed feedback dye laser with 106 ps pulse width and 616 nm wavelength were invested using only one XeCl-excimer laser as pump source. For optimized amplification of DFDL, the three-stage amplifiers were arranged with increasing cross-section and accordingly increasing pump energies. The first AmpI, II stages were dye cell of 5 mm, 10 mm and contained a $6{\times}10^{-4}$ [mol/l](solvent : Methanol) of Rhodamine 610. Double-pass amplification in the AmPII was measured to suppress the ASE by using a diffraction grating. The beam intensity of AmpI, II was saturated with a gain of respectively 10 and 48. The last AmpIII was Bethune cell of 30 mm and contained a $3{\times}10^ {-4}$ [mol/l] (solvent : Ethanol) of Rhodamine 610. In the single-pass and double-pass amplification, the output energy was obtained 168.2 $\mu$J and 471$\mu$J respectively.

  • PDF

Mechanical Property Variations of the Strip in the Skin Pass Process after Hot Rolling (열연 강판의 정정공정에 따른 재질변화 예측기술)

  • Lee, J.H.;Kim, H.J.;Kim, J.M.;Lee, J.K.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.211-214
    • /
    • 2008
  • The Mechanical properties of steel in hot strip mill were associated with the various rolling conditions such as alloy composition, plastic deformation, cooling history and so on. After coiling process of strip which is the end of hot rolling process, the coil can be the final product or can be applied by another process, that is, cold rolling or skin pass rolling with the additional changes of mechanical properties. Skin pass rolling process with the small reduction affects the mechanical properties of the strip. Because many kinds of hot strips are delivered to the customers after the skin pass process, it is important for us to know the skin pass effects for the mechanical properties of the hot rolling strip. In this study, the variations of mechanical properties of the strip after the skin pass rolling will be discussed. Then, the mathematical model will be proposed for the prediction of mechanical properties of the final products with the comparison between measured and calculated values.

  • PDF

Design and implementation of Tx and Rx band pass filter for personal communication services using (Zr,Sn)$TiO_4$ system ceramics ((Zr,Sn)$TiO_4$계 세라믹스를 이용한 PCS용 송,수신 대역통과 필터의 설계 및 구현)

  • 윤중락;이헌용
    • Electrical & Electronic Materials
    • /
    • v.9 no.9
    • /
    • pp.933-941
    • /
    • 1996
  • In this study, the Tx(Transmitting) and Rx(Receiving) band pass filter for personal communication services was constructed and designed using .lambda./4 TEM mode dielectric resonators. Band pass filter was composed of ceramics resonators which has been developed using ($Zr_{0.65}$,$Sn_{0.35}$) $Ti_{1.04}$ $O_{4.04}$ ceramic and Unloaded-Q ( $Q_{o}$) of .lambda./4 TEM mode dielectric resonator with inner hole size 0.9mm and external size 3mm using silver electrode is 354.5 at 1.95GHz. For the band pass filter design and construction, the design theory and simulation results of band pass filter using J-inverter theory have been studied. The parameters which are evaluated by design theory are practically applied to the filter construction and the simulation results are in agreement with the measured results after fine tunnings.s.s.s.s.s.

  • PDF

Double-pass Second Harmonics Generation of Tunable CW Infrared Laser Beam of DOFA System in Periodically Poled LiNbO3 (PPLN 비선형 결정과 이중통과법을 이용한 DOFA 시스템에서 증폭된 연속발진형 파장가변 적외선 레이저광의 제 2고조파 발생)

  • Yoo, Kil-Sang;Jo, Jae-Heung;Ko, Kwang-Hoon;Lim, Gwon;Jeong, Do-Young
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.229-236
    • /
    • 2008
  • The optimum conditions of second harmonic generation (SHG) can be successfully achieved experimentally using single pass and double pass methods of a pumping beam. The beam has a power of several Watts radiated by a DOFA (Diode Laser Oscillator & Fiber Amplifier) system, which is a high power CW wavelength tunable infrared laser system, in a PPLN (Periodically Poled MgO doped Lithium Niobate) nonlinear crystal. In the case of a single pass method, the parameters are the wavelength of 535 nm for SHG and the output power of 245 mW generated from the pumping input beam with wavelength of 1070 nm and the power of 2.45 W at phase matching temperature of $108.9^{\circ}C$. The conversion efficiency of SHG was 10%. In order to enhance the output of SHG, the double pass method of the SHG system of a PPLN using a concave mirror for the retroreflection and a pair of wedged flat windows for phase compensation was also presented. In this double pass system, we obtained the SHG output beam with the wavelength of 535 nm and the maximum power of 383 mW at optimum phase matching temperature of $108.5^{\circ}C$ by using an incident pumping beam with wavelength of 1070 nm and the power of 2.45 W. The maximum conversion efficiency is 15.6%, which is more than that of the single pass method.

An Analysis of the Pass-by Noise Reduction for KTX by Noise Reduction Device (소음저감 장치에 의한 KTX 차량의 운행소음 저감량 분석)

  • Jung, Sung-Soo;Kim, Yong-Tae;Jun, Byung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.767-770
    • /
    • 2002
  • Reduction of the propagation noise generated during pass-by of KTX by noise barrier was measured and analysed for the two kinds of top-shaped noise reduction devices; one as a plywood board and the other as a PVC pipe were placed periodically. The height and length of reference noise barrier are 2.4 m and 50 m, respectively. The noise reduction with and without noise reduction devices was investigated.

  • PDF