• Title/Summary/Keyword: M-B curve

Search Result 374, Processing Time 0.023 seconds

A Study on the Soil Water Characteristic Curve with Change of Coefficient of Uniform in Compacted Granitic Soils (다짐 화강풍화토의 균등계수 변화에 따른 함수특성곡선에 관한 연구)

  • Yoo, Kun-Sun;Kim, Doc-Kyoung;Yoo, Nam-Jae
    • Journal of Industrial Technology
    • /
    • v.29 no.A
    • /
    • pp.145-153
    • /
    • 2009
  • In this study, to determine characteristics of compaction and the soil water characteristic curve(SWCC) in decomposed granitic soils, compaction tests and SWCC tests were carried out for samples having various contents of coefficient of uniform($c_u$), By compacting their samples with standard Proctor density test, the effects of binder contents on maximum dry density and optimum moisture content were investigated and compared. Samples compacted with the maximum dry density and the optimum moisture content were tested by means of the SWCC, to determine their SWCC parameters, such as Brooks & Corey(${\lambda}$, ${\Psi}_b$), Van Genuchten (${\alpha}$, n, m), Fredlund & Xing(a, n, m).

  • PDF

Thermodynamic Analysis of the Low- to Physiological-Temperature Nondenaturational Conformational Change of Bovine Carbonic Anhydrase

  • Hollowell, Heather N.;Younvanich, Saronya S.;McNevin, Stacey L.;Britt, B. Mark
    • BMB Reports
    • /
    • v.40 no.2
    • /
    • pp.205-211
    • /
    • 2007
  • The stability curve - a plot of the Gibbs free energy of unfolding versus temperature - is calculated for bovine erythrocyte carbonic anhydrase in 150 mM sodium phosphate (pH = 7.0) from a combination of reversible differential scanning calorimetry measurements and isothermal guanidine hydrochloride titrations. The enzyme possesses two stable folded conformers with the conformational transition occurring at ~30$^{\circ}C$. The methodology yields a stability curve for the complete unfolding of the enzyme below this temperature but only the partial unfolding, to the molten globule state, above it. The transition state thermodynamics for the low- to physiological-temperature conformational change are calculated from slow-scan-rate differential scanning calorimetry measurements where it is found that the free energy barrier for the conversion is 90 kJ/mole and the transition state possesses a substantial unfolding quality. The data therefore suggest that the x-ray structure may differ considerably from the physiological structure and that the two conformers are not readily interconverted.

LIGHT CURVE VARIATIONS OF AR LACERTAE

  • Nha, Il-Seong
    • Journal of Astronomy and Space Sciences
    • /
    • v.8 no.2
    • /
    • pp.149-158
    • /
    • 1991
  • Sixteen unitary Light curves of AR Lac in B and V are made at Yonsei University Observatory in the period of 1980-1988. Some overview findings of light variations are made. (1) The light variation outside eclipse follow none of the wave migration patterns reported by previous investigators. (2) Complicated shapes outside eclipse are apparently much reduced in the light curves of 1983-1984. This suggests than, in the future, AR Lac has a chance to attain a normal state with no complicated interactions. (3) The depths of the primary and the secondary mid-eclipses are changing year-to-year. (4) The K0 star, the larger component, has brightened by $0.^m$ 14 in V, while the G2 star has shown a fluctuation of about $0.^m$05 in V. (5) The B-V values at primary mid-eclipse have no correlation with the depth variations. (6) Independently of the increase of maximum brightness, the B-V colors in the non-eclipsed phases changed slightly over the years.

  • PDF

Crack location in beams by data fusion of fractal dimension features of laser-measured operating deflection shapes

  • Bai, R.B.;Song, X.G.;Radzienski, M.;Cao, M.S.;Ostachowicz, W.;Wang, S.S.
    • Smart Structures and Systems
    • /
    • v.13 no.6
    • /
    • pp.975-991
    • /
    • 2014
  • The objective of this study is to develop a reliable method for locating cracks in a beam using data fusion of fractal dimension features of operating deflection shapes. The Katz's fractal dimension curve of an operating deflection shape is used as a basic feature of damage. Like most available damage features, the Katz's fractal dimension curve has a notable limitation in characterizing damage: it is unresponsive to damage near the nodes of structural deformation responses, e.g., operating deflection shapes. To address this limitation, data fusion of Katz's fractal dimension curves of various operating deflection shapes is used to create a sophisticated fractal damage feature, the 'overall Katz's fractal dimension curve'. This overall Katz's fractal dimension curve has the distinctive capability of overcoming the nodal effect of operating deflection shapes so that it maximizes responsiveness to damage and reliability of damage localization. The method is applied to the detection of damage in numerical and experimental cases of cantilever beams with single/multiple cracks, with high-resolution operating deflection shapes acquired by a scanning laser vibrometer. Results show that the overall Katz's fractal dimension curve can locate single/multiple cracks in beams with significantly improved accuracy and reliability in comparison to the existing method. Data fusion of fractal dimension features of operating deflection shapes provides a viable strategy for identifying damage in beam-type structures, with robustness against node effects.

The Fabrication of $MgB_{2}$ superconducting tape and its transport critical current property under magnetic field (Mg $B_{2}$초전도 선재 제조 및 자장하에서의 임계전류특성)

  • J-W Ko;J.M. Yoo;Y.K. Kim;K-H Oh;S.J. Choi;H.S. Chung;H. Kumakura;K. Togano
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.3-4
    • /
    • 2002
  • The stainless steel sheathed MgB$_2$ tapes with Cu addition were fabricated by PIT method without heat treatment. The $J_{c}$ value of 5,600 A/ $cm^{2}$and 16,000 A/$cm^{2}$ at 4.2 K and 5 T were obtained for the $MgB_{2}$ tape and 10 vol % of Cu added $MgB_{2}$ tape respectively. The $J_{c}$-B curve shows enhancement in J$_{c}$ under magnetic field, which suggests enhancement in flux pinning property with Cu addition.n.

  • PDF

THE SLOPE OF ΔM LIGHT CURVE DEPENDING UPON THE ITS LOCATION IN CCD FRAME (CCD 이미지 상의 그 위치와 ΔM 광도곡선의 기울기)

  • 정장해;임인성
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.1
    • /
    • pp.39-46
    • /
    • 2002
  • BV observations for V523 Cas were performed with 1.8m telescope and 2K CCD camera at Bohyunsan Optical Astronomy Observatory, Korea, on October 27, 1999. ${\Delta}m$ light curves for 11 comparison objects were made. It was found that their light curve slopes are different each other. Factor analysis for items of slope, (b-v) , magnitude, X pixel, and Y pixel results that there is strong correlation between the slope and the location (X,Y). It might be due to problems of CCD cooling system.

Antifungal Activity of Bee Venom and Sweet Bee Venom against Clinically Isolated Candida albicans

  • Lee, Seung-Bae
    • Journal of Pharmacopuncture
    • /
    • v.19 no.1
    • /
    • pp.45-50
    • /
    • 2016
  • Objectives: The purpose of this study was to investigate the antifungal effect of bee venom (BV) and sweet bee venom (SBV) against Candida albicans (C. albicans) clinical isolates. Methods: In this study, BV and SBV were examined for antifungal activities against the Korean Collection for Type Cultures (KCTC) strain and 10 clinical isolates of C. albicans. The disk diffusion method was used to measure the antifungal activity and minimum inhibitory concentration (MIC) assays were performed by using a broth microdilution method. Also, a killing curve assay was conducted to investigate the kinetics of the anti-fungal action. Results: BV and SBV showed antifungal activity against 10 clinical isolates of C. albicans that were cultured from blood and the vagina by using disk diffusion method. The MIC values obtained for clinical isolates by using the broth microdilution method varied from $62.5{\mu}g/mL$ to $125{\mu}g/mL$ for BV and from $15.63{\mu}g/mL$ to $62.5{\mu}g/mL$ for SBV. In the killing-curve assay, SBV behaved as amphotericin B, which was used as positive control, did. The antifungal efficacy of SBV was much higher than that of BV. Conclusion: BV and SBV showed antifungal activity against C. albicans clinical strains that were isolated from blood and the vagina. Especially, SBV might be a candidate for a new antifungal agent against C. albicans clinical isolates.

Change in the Characteristics of Particle Separation and Particle Size Distribution of Weathered Granite Soil from the Yecheon Area (Eastern South Korea) after Water Washing (물 세척한 예천지역 화강풍화토의 입자분리와 입도분포 변화 특성)

  • Kim, Suk-Joo
    • The Journal of Engineering Geology
    • /
    • v.32 no.2
    • /
    • pp.241-255
    • /
    • 2022
  • In this study, sieve analysis testing was performed on weathered granite soil from Yecheon (eastern South Korea) before and after water washing in accordance with the sieve analysis regulations of KS F 2302. The changes in particle separation and particle size distribution after washing with water were analyzed. Image analysis using an optical microscope revealed that soil particles were separated into smaller particles by water washing. The change in the particle size distribution curve was assessed using five index values. The increase in the fine particle fraction (<0.075 mm) was 13.67%, the increase in the 0.075-0.25 mm fraction was 19.44%, and the mean particle diameter (D50) decreased by 0.663 mm. In addition, the maximum passage width (BM) of the particle size distribution curve increased by 21.08% for the #30 sieve, and the moving area (A) of the particle size distribution curve was 69.28%·mm. These results suggest that washing with water is an effective way to prevent underestimation of the fine particle content in soil.

Determination Errors of Saturation Magnetization and Magnetocrystalline Anisotropy Constant from Magnetization Curves of Magnetically (일측이방성 다결정의 자화곡선을 이용한 포화자화 및 결정자기이방성상수 결정에서의 오차분석)

  • Kim, M.J.;Hur, J.;Kim, Y.B.;Kim, T.K.
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.4
    • /
    • pp.173-176
    • /
    • 1999
  • Errors of saturation magnetization and magnetocrystalline anisotropy constant determined by magnetization curve of magnetically aligned unixial power were analyzed. In case of alignment factor ${\Theta}_0=10{\circ}$, magnetic constant errors of $Nd_2Fe_{14}B$ were calculated to be error of $M_S{\risingdotseq}1{\%}\;and\;error\;of\;K_1{\risingdotseq}13\;{\%}$, respectively, and magnetic constant errors of Ba-ferrite were calculated to be error of $M_S{\risingdotseq}1{\%}\;and\;error\;of\;K_1{\risingdotseq}17\;{\%}$. In this method, $M_s$ was found to be determined with high accuracy. High alignment is desirable for high accuracy.

  • PDF

Liquid Chromatography-Tandem Mass Spectrometry for the Determination of Lithospermic Acid B in Rat Serum

  • Kim, Hui-Hyun;Ji, Hye-Young;Lee, Hye-Won;Kim, Youn-Chul;Sohn, Dong-Hwan;Lee , Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.27 no.12
    • /
    • pp.1202-1206
    • /
    • 2004
  • A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/ MS) method for the determination of lithospermic acid B (LSB) in rat serum was developed. LSB and internal standard, 7-hydroxy-3-phenyl-chromen-4-one (HPC) were extracted from rat serum with methyl-tert-butyl ether at acidic pH and analyzed on a Luna $C_8$ column with the mobile phase of acetonitrile-ammonium formate (10 mM, pH 6.5) (50:50, v/v). The analytes were detected using a negative electrospray ionization tandem mass spectrometry in the multiple- reaction-monitoring mode. The standard curve was linear $(r^2 = 0.997)$ over the concentration range of 10.0-500 ng/mL. The coefficient of variation and relative error for intra- and interassay at three QC levels were 1.1~6.2% and -10.3~-2.7%, respectively. The recovery of LSB from serum sample ranged from 73.2 to 79.5%, with that of HPC (internal standard) being 75.1 %. The lower limit of quantification for LSB was 10 ng/mL using 50 ${\mu}L$ of serum sample.