• Title/Summary/Keyword: M/D/1

Search Result 14,759, Processing Time 0.067 seconds

Response for Lead Block Thickness of Parallel Plate Detector using Dielectric Film (유전체필름을 이용한 평행판검출기의 납 차폐물 두께변화에 대한 반응)

  • Kim Yong-Eun;Cho Moon-June;Kim Jun-Sang;Oh Young-Kee;Kim Jhin-Kee;Shin Kyo-Chul;Kim Jeung-Kee;Jeong Dong-Hyeok;Kim Ki-Hwan
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • A parallel plate detector containing PTFE films in FEP film for relative dosimetry was designed to measure the response of detectors to S and 10 MV X-rays from a medical linear accelerator through different thicknesses of lead. The dielectric materials were 100 m thick. The set-up conditions for measurements with this detector were as follows: SSD=100 cm the test detector was at a depth of 5 cm and the reference chamber was at a depth of 10 cm from the phantom surface for 6 and 10 MV X-rays. Lead blocks were designed to cover the irradiated field. They were added to the tray to increase thickness sequentially. We found that the detector response decreased exponentially with the thickness of lead added. The linear attenuation coefficients of the test detector and reference chamber were 0.1414 and 0.541, respectively, for 6 MV X-rays and 0.1358 and 0.5279 for 10 MV X-rays. The test detector response was greater than that of the reference chamber. The response function was calculated from the measured values of the test detector and reference chamber using optimization. These optimized constants for the detector response function were independent of theenergy. As a result of optimizing the response function between detectors, the use of a relative dosimeter was validated, because the response of the test detector was 1% for 6 MV X-rays and 4% for 10 MV X-rays.

  • PDF

Development of KD- Propeller Series using a New Blade Section (새로운 날개단면을 이용한 KD-프로펠러 씨리즈 개발)

  • J.T. Lee;M.C. Kim;J.W. Ahn;H.C. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.2
    • /
    • pp.52-68
    • /
    • 1991
  • A new propeller series is developed using the newly developed blade section(KH18 section) which behaves better cavitation characteristics and higher lift-drag ratio at wide range of angle-of-attack. The pitch and camber distributions are disigned in order to have the same radial and chordwise loading distribution with the selected circumferentially averaged wake input. Since the geometries of the series propeller, such as chord length, thickness, skew and rate distribations, are selected by regression of the recent full scale propeller geometric data, the performance prediction of a propeller at preliminary design stage can be mure realistic. Number of blades of the series propellers is 4 and the expanded blade area ratios are 0.3, 0.45, 0.6 and 0.75. Mean pitch ratios are selected as 0.5, 0.65, 0.8, 0.75 and 1.1 for each expanded area ratio. The new propeller series is composed of 20 propellers and is named as KD(KRISO-DAEWOO) propeller series. Propeller open water tests are performed at the experimental towing tank, and the cavitation observation tests and fluctuating pressure measurements are carried out at the cavitation tunnel of KRISO. $B_{P}-\delta$ curves, which can be used to select the optimum propeller diameter at the preliminary design stage, are derived from a regression analysis of the propeller often water test results. The KD-cavitation chart is derived from the cavitation observation test results by choosing the local maximum lift coefficient and the local cavitation number as parameters. The caviy extent of a propeller can be predicted more accurately by using the KD-cavitation chart at a preliminary design stage, since it is derived from the results of the cavitation observation tests in the selected ship's wake, whereas the existing cavitation charts, such as the Burrill's cavitation chart, are derived from the test results in uniform flow.

  • PDF

Economic Feasibility Analysis Study to Build a Plant-based Alternative Meat Industrialization Center (식물성 기반 대체육 산업화센터 구축을 위한 경제적 타당성 분석)

  • Yong Kwang Shin;So Young Lee;Jae Chang Joo
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.25 no.4
    • /
    • pp.118-126
    • /
    • 2024
  • Recently, the alternative meat (food) market is growing rapidly due to the increase in meat consumption due to global population growth and income improvement, as well as issues such as equal welfare, carbon neutrality, and sustainability. The government is also developing a green bio convergence new industry development plan to foster alternative foods, but there are difficulties in commercialization due to the lack of technology and insufficient production facilities among domestic small and medium-sized enterprises, so it is necessary to build joint utilization facilities and equipment to resolve the difficulties faced by companies. am. In addition, small and medium-sized enterprises are having difficulty developing and commercializing plant-based meat substitutes due to a lack of technical skills, and related equipment is expensive, making it difficult to build equipment on their own. Accordingly, Jeollabuk-do is pursuing a strategy to secure the source technology for development, processing, and industrialization of plant-based substitute meat at the level of developed countries by establishing a plant-based alternative meat industrialization center. In this study, an economic feasibility analysis study was conducted when a plant-based alternative meat industrialization center is built in Jeollabuk-do. As a result of the analysis, B/C=1.32, NPV=374 million won, and IRR=4.8%, showing that there is economic feasibility in establishing an alternative meat industrialization center. In addition, as a result of analyzing the regional economic ripple effect resulting from the establishment of an industrialization center, if 38 billion won is invested in Jeollabuk-do, the nationwide production inducement effect is 74 billion won, the added value inducement effect is 29.8 billion won, and the employment inducement effect is 672 people

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Biochemical Effects of ABA and $GA_3$ on the Growth of Rice(Oryza sativa L.) Seedings (ABA와 $GA_3$가 유묘기(幼苗期)의 벼(Oryza sativa L.) 생육(生育)에 미친 생화학적(生化學的) 영향(影響))

  • Shon, Tae Kwon;Lee, Sang Chul;Kim, Kil Ung
    • Current Research on Agriculture and Life Sciences
    • /
    • v.11
    • /
    • pp.31-41
    • /
    • 1993
  • The biochemical effects of ABA and $GA_3$ on rice seedling stages were investigated from two rice cultivars, Dongjinbyeo and Samgangbyeo. Some of the results obtained are as follows ; The shoot growth was significantly increased at all concentrations of $GA_3$ compared to the control but it was completely inhibited by ABA. The root length was not affected by all concentrations of $GA_3$ except for the highest concentration of $10^{-3}M$. ABA had an inhibitary effect on root growth and showed similar trend to the shoot growth. By increasing the concentration of $GA_3$, sugar content of rice seedlings was increased and starch content was decreased. On the contrary, the treatment of ABA revealed that sugar content was decreasing with higher level of starch content. Chlorophyll content was greatly reduced at the all concentrations of $GA_3$ in both cultivars tested. Generally, the responses of root activity decreased with treatment of $GA_3$ but no difference in the activity was observed in Samgangbyeo. Major fatty acids of rice seedlings were investigated as palmitic, oleic, and linoleic acid with little contents of linolenic acid and stearic acid. The contents of these fatty acids were decreased with ABA and increased with $GA_3$ treatment, respectively. A protein band of 24 kD in the electrophoresis was observed with ABA treated rice seedlings but not with $GA_3$.

  • PDF

A Study on the Pollution of Polycyclic Aromatic Hydrocarbons (PAHs) In the Column Sediments around Gwangyang Bay (광양만 주변해역 주상퇴적물에서의 다환방향족탄화수소류(PAHs)의 오염에 관한 연구)

  • You, Young-Seck;Cho, Chon-Rae;Cho, Hyeon-Seo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.4
    • /
    • pp.257-266
    • /
    • 2008
  • PAHs are of mainly anthropogenic origin from urban runoff, oil spill and combustion of fossil fuels. Some PAHs are potentially carcinogenic and mutagenic to aquatic organisms. This study was carried out to survey the contamination of PAHs in the column sediments around Gwangyang bay. Yeosu petrochemical industrial complex, POSCO(Pohang steel compony) and Gwangyang container harbor are located near the bay. The column sediments were collected at 4 stations(A, B, C and D) and fractionated at intervals of two-centimeter depth on July 29, 1999. PAHs in colmn sediment samples were extracted in soxhlet extractor and were identified and quantified by GC-MS. PAHs compounds were analyzed and found to be 13 species. Total PAHs concentrations in the column sediments ranged from 275.04 to 2,838.64${\mu}g/kg$ dry wt. Naphthalene had the highest concentration in the range of 40.60 to 2,294.06${\mu}g/kg$ dry wt. and Anthracene had the lowest concentration in the range of 2.63 to 11.30${\mu}g/kg$ dry wt. The correlation coefficients between individual PAHs and total PAHs in the column sediments were relatively higher in the low molecular compounds such as Naphthalene, Acenaphthylene and Phenanthrene. The relationship between the P/A(Phenanthrene/Anthracene)ratio and F/P(Fluoranthene/Pyrene)ratio showed that P/A ratio was generally above 10 and F/P ratio was above 1 in all sediment samples. These data indicate that PAHs in the column sediments around Gwangyang bay seem to be of both pyrolytic and petrogenic origin The values of PAHs in the column sediments were lower than the biological effect guidelines.

  • PDF

A study of Association of the H-FABP RFLP with Economic Traits of Pigs (돼지 H-FABP 유전자의 다형성 및 경제 형질과의 연관성 구명)

  • Choi, B.H.;Kim, T.H.;Lee, J.W.;Cho, Y.M.;Lee, H.Y.;Cho, B.W.;Cheong, I.C.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.703-710
    • /
    • 2003
  • The purpose of this study was to detect association between genetic variation and economic trait in the porcine heart type fatty acid-binding protein gene as a candidate gene for the traits related with growth and meat quality in pigs. The H-FABP is a 15-kDa protein expressed in several tissues with high demand for fat metabolism such as cardiac and skeletal muscle and lactating mammary gland. H-FABP is small intracellular protein involved in fatty acid transport from the plasma membrane to the site of $\beta$-oxidation and/or triacylglycerol or phospholipid synthesis. In this study, H-FABP PCR-RFLP was performed in F$_2$ population composed of 214 individuals from an intercross between Korean Native Boars and Landrace sows. PCR products from two primer sets within H-FABP gene were amplified in 850bp and 700bp. Digestion of PCR products with the restriction digestion enzymes HaeⅢ and HinfⅠ, revealed fragment length polymorphisms(RFLPs). The genotype frequencies from H-FABP/HaeⅢ was .29 for genotype DD, .53 for genotype Dd, and .15 for genotype dd, respectively. The genotype frequencies of HH, Hh, and hh from H-FABP/HinfⅠ was .38, .41 and .20, respectively, in the population. Relationships between their genotypes and economic traits were estimated. In H-FABP/HaeⅢ locus, there were specific genotypes(Dd and dd) associated with economic traits such as body weights at 3, 5, 12, and 30 week of age (p〈.05 to .001). The ‘d’ allele was associated with gaining of body weight. In H-FABP/HinfⅠ locus, Genotypes of HH and Hh associated with growth traits such as body weights at 5, 12, and 30 week of age (p〈.05 or p〈.001) and back fat thickness, body fat including abdominal and trimmed fat (p〈.001) and intramuscular fat(p〈.05) The ‘H’ allele was positively associated with gaining of body weight and fatness deposition. In conclusion, a significant association of the H-FABP gene from its genetic variation was found on body weight, intramuscular fat and backfat thickness.

Sex Detection and In Vitro Development of Biopsied Bovine Embryo for LAMP Based Embryo Sexing (LAMP 방법에 의한 소 수정란의 성 판별과 Biopsy에 따른 수정란의 체외발달)

  • Cho S. R.;Choi S. H.;Kim H. J.;Han M. H.;Choe C. Y.;Chung Y. G.;Son D. S.
    • Journal of Embryo Transfer
    • /
    • v.20 no.2
    • /
    • pp.169-176
    • /
    • 2005
  • Loop-mediated isothermal amplification (LAMP) is novel DNA amplification methods that amplifies a target sequence specifically under isothemal condition. The present study was to assess the in vitro viability afier biopsy and sexing rate of different types of embryo biopsied. In vivo compact morulae and blastocyst embryos were obtained from Korean Native Cow (KNC) superovulated with FSH (Antorin, R-10) on 7 Day after artificial insemination. in vitro compact morulae and blastocyst embryos were obtained with KNC or Holsteins that were gained on 6, 7 or 8 day after in vitro fertilization(IVF) with frozen semen. Biopsy of bovine embryo was carried out in a $80{\mu}l$ drop with $Ca^{2+}-Mg^{2+}$ free D-PBS and the viability of biopsied embryos were evaluated in IVMD (IFP, Japan) medium at 12 hrs culture time. The sex ratio of biopsied Hanwoo embryos were male vs. female of $43.5\%\;vs.\;56.5\%$ in vivo and $33.9\%\;vs.\;49.2\%$ in vitro respectively, and male rate of biopsied Holstein embryos were significantly higher than female $(70.8\;vs.\;29.2\%)$. and indefinite rate of in vitro embryos was $16.9\%$ and in vivo was not. The degeneration rate of biopsied embryo, in vitro embryos were significantly higher than in vivo $(13.2\%\;vs,\;0.0\%,\;p<0.05)$. The survivability of in vivo embryo were between biopsied following punching method was significantly (P<0.05) higher than bisection method produced embryos $(100\%\;vs.\;83.3\%)$ and in vitro had no difference. However, the degeneration rate of biopsied embryo by bisection method was significantly higher than punching methods between in vivo and in vitro $(16.7\;vs.\;22.6\%,\;respectively,\;p<0.05)$. In conclusion, these results indicate that punching method was optimal and survivability after embryo biopsy was useful for reducing the damage caused by the embryo biopsy procedure for LAMP-based embryo sexing.

Radioiodine Therapy of Liver Cancer Cell Following Tissue Specific Sodium Iodide Symporter Gene Transfer and Assessment of Therapeutic Efficacy with Optical Imaging (조직 특이 발현 Sodium Iodide Symporter 유전자 이입에 의한 방사성옥소 간암세포 치료와 광학영상을 이용한 치료효과 평가)

  • Jang, Byoung-Kuk;Lee, You-La;Lee, Yong-Jin;Ahn, Sohn-Joo;Ryu, Min-Jung;Yoon, Sun-Mi;Lee, Sang-Woo;Yoo, Jeong-Soo;Cho, Je-Yeol;Lee, Jae-Tae;Ahn, Byeong-Cheol
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.383-393
    • /
    • 2008
  • Purpose: Cancer specific killing can be achieved by therapeutic gene activated by cancer specific promotor. Expression of sodium iodide symporter (NIS) gene causes transportation and concentration of iodide into the cell, therefore radioiodine treatment after NIS gene transfer to cancer cell could be a form of radionuclide gene therapy. luciferase (Luc) gene transfected cancer cell can be monitored by in vivo optical imaging after D-luciferin injection. Aims of the study are to make vector with both therapeutic NIS gene driven by AFP promoter and reporter Luc gene driven by CMV promoter, to perform hepatocellular carcinoma specific radiodiodine gene therapy by the vector, and assessment of the therapy effect by optical imaging using luciferase expression. Materials and Methods: A Vector with AFP promoter driven NIS gene and CMV promoter driven Luc gene (AFP-NIS-CMV-Luc) was constructed. Liver cancer cell (HepG2, Huh-7) and non liver cancer cell (HCT-15) were transfected with the vector using liposome. Expression of the NIS gene at mRNA level was elucidated by RT-PCR. Radioiodide uptake, perchlorate blockade, and washout tests were performed and bioluminescence also measured by luminometer in these cells. In vitro clonogenic assay with 1-131 was performed. In vivo nuclear imaging was obtained with gamma camera after 1-131 intraperitoneal injection. Results: A Vector with AFP-NIS-CMV-Luc was constructed and successfully transfected into HepG2, Huh-7 and HCT-15 cells. HepG2 and Huh-7 cells with AFP-NIS-CMV-Luc gene showed higher iodide uptake than non transfected cells and the higher iodide uptake was totally blocked by addition of perchlorate. HCT-15 cell did not showed any change of iodide uptake by the gene transfection. Transfected cells had higher light output than control cells. In vitro clonogenic assay, transfected HepG2 and Huh-7 cells showed lower colony count than non transfected HepG2 and Huh-7 cells, but transfected HCT-15 cell did not showed any difference than non transfected HCT-15 cell. Number of Huh-7 cells with AFP-NIS-CMV-Luc gene transfection was positively correlated with radioidine accumulation and luciferase activity. In vivo nuclear imaging with 1-131 was successful in AFP-NIS-CMV-Luc gene transfected Huh-7 cell xenograft on nude mouse. Conclusion: A Vector with AFP promoter driven NIS and CMV promoter driven Luc gene was constructed. Transfection of the vector showed liver cancer cell specific enhancement of 1-131 cytotoxicity by AFP promoter, and the effect of the radioiodine therapy can be successfully assessed by non-invasive luminescence measurement.

Inhibitory Effect of Rhus Verniciflua Extract on Lipid Peroxidation and Inflammatory Cytokines during Endurance Exercise Training (지구성 운동시 옻나무 추출액의 지질과산화 및 염증성사이토카인 억제효과)

  • Lee, Youn-Kyung;Kwon, Oh-Seon;Song, Young-Ju;Kim, Sea-Hyun;Kim, Pan-Gi;Ryu, Sung-Pil
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.1
    • /
    • pp.102-110
    • /
    • 2010
  • This study was performed to find out the inhibitory effect of Rhus Verniciflua extract on lipid peroxidation and inflammatory cytokines during endurance exercise training for 8 weeks in rats. For this study, Sprague-Dawley rats were divided into 4 groups; sedentary (SED), exercise training (TRA), RVS extract ingestion (RVE), and RVS extract ingestion and exercise training (RVE-TRA). TRA and RVE-TRA were trained on treadmill with increasing speed gradually and administered 10 mL/kg/d of Rhus Verniciflua extract orally to RVE and RVE-TRA. In order to analyze antioxidant function, blood SOD (superoxide dismutase), GSH-Px (glutathione peroxidase), and MDA (malondialdehyde) were examined. And, analysis of inflammatory cytokines were examined using IL-6 (interleukin-6), TNF-${\alpha}$ (tumor necrosis factor-alpha), CRP (C-reactive protein), and NO (nitric oxide). SOD in TRA was significantly higher than SED and RVE (p<0.05), and RVE-TRA was highest among the groups (p<0.05). The MDA content of TRA, RVE and RVE-TRA were significantly lower than SED. GSH-Px activity of SED was significantly lower than other groups (p<0.05). IL-6 and TNF-${\alpha}$ content of RVE and RVE-TRA were significantly lower than SED and TRA (p<0.05). CRP concentration of SED was the lowest among groups (p<0.05). Finally, NO concentration of SED and TRA were higher than RVE and RVE-TRA (p<0.05). These results suggested that it is efficient for rats to reduce lipid peroxidation and induce anti-inflammatory by taking RVS extract during exercise training. Afterwards, if studies on the properties of RVS extract can be made with various ways, use of Rhus Verniciflua trees might be made widely which are growing naturally in mountains in Korea.