• Title/Summary/Keyword: M/C Accuracy

Search Result 665, Processing Time 0.028 seconds

A Study on the Test Workpiece for Accuracy Evaluation of 5-Axis Machine Tool (5축 공작기계 정밀도 평가를 위한 표준 공작물에 관한 연구)

  • Youn, Jae-Woong;Kim, Ki-Hwan;Park, Jong Tak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.431-439
    • /
    • 2014
  • Recently, a demand for precision 5-axis machine tools is significantly increasing, and the maintenance of machine tool accuracy becomes more important. it is very difficult to evaluate to accuracy of 5-axis M/C in the production site since it needs expensive measuring equipment and skilled engineer. On the other hand, evaluation items of 5-axis M/C are not systematically organized in the existing KS and ISO standards. In this study, the evaluation items for 5-axis M/C were derived systematically and a test workpiece was developed to evaluate the machine tool accuracy more easily. The error sources of machine tool can be estimated by machining and measuring of the test workpiece. The correlation between the machine tool accuracy and the accuracy of machined test workpiece was analyzed. As a result, the accuracy of machined test workpiece represented the accuracy of machine tool and the error sources very effectively.

A Study on Performance and Reliability Test of High Speed Feeding Type Laser Cutting M/C (고속 이송방식 Laser Cutting M/C의 성능 및 신뢰성 평가에 관한 연구)

  • 이춘만;임상헌
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1007-1010
    • /
    • 2002
  • The accuracy of high speed feeding type laser cutting M/C is the major factor directly concerned with the accuracy of the processed work, and the feed errors of feed system make the machining errors of work directly on processing. In this point, this study focused on the generative elements in feed errors of laser cutting M/C when operating its laser head. In order to improve the accuracy of this machining center, feed errors are measured by a laser interferometer.

  • PDF

A Study on the Accuracy of the Loran C China North Sea Chain (GRI 7430) Fix in Kunsan Area (군산지역에서 Loran C China North Sea Chain (GRI 7430 )의 측위 정도의 연구)

  • Won-Woo Lee
    • Journal of the Korean Institute of Navigation
    • /
    • v.22 no.3
    • /
    • pp.9-16
    • /
    • 1998
  • Loran C is a low frequently , pulsed. hyperbolic radio aid to navigation system, which operates in the 90 to 110 kHz frequency band. The position accuracy is not excellent but the repeatable and relative accuracy is very good, and it is very useful for fishing vessel in coastal waters. The operation of China north sea chain9GRI 7430) was begun on January, 1996, and in order to evaluate the accuracy of this chain, it was observed with Loran C receiver (LC-90, Furuno) in July 9 and December 30, 1997 at the fixed position of Kunsan national university. The obtained results were as follows : The time difference error of M-X, M-Y pair were $0.5{\mu}s$, $4.4{ \mu}s$ respectively and the mean time difference of M-X, M-Y pair were $15120.4{,\mu}s$ $32085.4{\mu}s$ respectively. The Loran C signals were received steadily and the daily fluctuation of time difference was very small. The longitudinal position error was very much than latitudinal position error, and the mean position error was about 1091.8m.

  • PDF

Accuracy of the Loran-C Fix in Cheju Areas (제주지역에서의 Loran-C 위치의 정도)

  • Kim, Gwang-Hong;Sim, Hyeong-Il;Jang, Chung-Sik
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.2
    • /
    • pp.123-130
    • /
    • 1985
  • This paper was conducted for the purpose of evaluating the accuracy of the observed time difference in Loran-C when the ground wave propagated on the surface included both land sea. The time difference of X and Y station in North East Pacific Chain GRI 5970 was measured at 25 points in Cheju areas. The results obtained are as follows: (1) The errors of time difference for M-X pair are increased when the Loran-C wave propagates above 500m heights of Hanla mountain on propagation path between the observed point and master or X, Y slave station. (2) The errors of time difference for M-X pair are able to decrease by way of correction for the propagation velocity and the geodetic datum, but errors of the time difference for M-Y pair very irregularly because irregular terrain include in propagation path from X station and propagation path from Y station is twice longer than X station. (3) It is confirmed that accuracy of Loran-C fix can elevate by the way of all correction for a geodetic datum transformation, the propagation velocity with refractive index of radio wave and the propagation velocity over land.

  • PDF

A study on the accuracy of zirconia copings using dental CAD / CAM system (치과용 CAD/CAM 시스템을 이용한 지르코니아 코핑의 정확성에 관한 연구)

  • Yoon, Seong-Geun;Choi, Byung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.33 no.2
    • /
    • pp.137-145
    • /
    • 2011
  • Purpose: To evaluate the accuracy of zirconia copings in terms of clinical verified for the clinical application of CAD/CAM. Methods: Zirconia copings (n=5) were prepared using CAD/CAM system and were sintered using the relevant electrical induction furnace, which uses a 2h sintering program with a maximum temperature of $1500^{\circ}C$. The copings placed at the models and the interval values were measured. Results: The meas interval values between the die and the zirconia copings were $44.14{\mu}m$(A), $44.57{\mu}m$(B), $44.72{\mu}m$(C). 51.05 ${\mu}m$(D). Conclusion: The maximum interval values between the die and the zirconia copings were $51.3{\mu}m$ which is acceptable for clinical use. ${\mu}m$ Proper understanding of the test conditions will help enhancing the accuracy of zirconia coping.

A 110dB, 3-mW Fourth-order ${\Sigma}-{\Delta}$ Modulator for high accuracy measure systems (110dB, 3-mW 4차 단일비트 시그마 델타 모듈레이터)

  • Kim, Tae-Yoon;Park, Won-Ki;Min, Kyong-Won;Choi, Jong-Chan;Lee, Sung-Chul
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.609-610
    • /
    • 2008
  • In this paper, a 110 dB, 1.024 MHz fourth-order single-loop Delta-Sigma sigma modulator has been presented with an over-sampling ratio of 128 and an overload factor of -6 dB for a bandwidth of 4 kHz. In particular, this ${\Sigma}-{\Delta}$ modulator is well suited for high accuracy measure systems. The whole modulator consumes only 3-mW from a single 3.3V supply in a $0.35-{\mu}m$ CMOS technology.

  • PDF

Chemical Mechanical Micro Machining(C3M) Process (화학 기계적 미세가공 기술)

  • 박준민;정해도;김성헌;정상철;이응숙
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.739-742
    • /
    • 2000
  • Micro machining technology has been studied to fabricate small size and high accuracy milli-structure products. To perfectly overcome the conventional mechanical machining methods, the chemical mechanical micro machining(C3M) process was developed. The mechanism of C3M process is that chemical solution etches the material and results in the generation of the chemical reacted layer, and the mechanical micro tool subsequently removes the layer. From the fundamental experiments, the C3M process has been founded to have the advantages of lower machining resistance, tool wear, and higher surface quality and form accuracy than conventional methods. This study focuses on the micro grooving of both the metallic material(SKDII, A1) and hard brittle silicon oxide.

  • PDF

A Study on the Accuracy of the Loran-C Fix of Korean Chain in Pusan Area (부산지역에서의 Loran-C 한국체인의 측위정도에 관한 연구)

  • 박주삼
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.4
    • /
    • pp.372-380
    • /
    • 1996
  • The operation of Far East Chain(GRI 5970) of Loran - C system had been stopped on June, 1995, but that of Korean Chain(GRI 9930) of Loran - C system which was jointed with North West Pacific Chain(GRI 8930) and Russia Chain(GRI 7950) by international cooperation, was started on January 1996. In this paper, in order to study the accuracy of Loran - C fix of Korean Chain, the authors examined and analyzed the data of the reciever of Loran - C(LC -90, Furuno) and GPS(AccNav Sport super (TM), Eagle) measured automatically and continually for 2 seconds at interval of 5 minutes from November 22, 1992, to January 20, 1996 at the fixed position of National Fisheries University of Pusan, The results obtained were as follows ; 1)The mean time differences of M-W, M-X, and M-Y pair measured in the base observed position were 12333.09${\mu}$s, 28338.44${\mu}$s, and 42806.01${\mu}$s respectively and the mean standard deviations of that were 0.0121${\mu}$s, 0.0290${\mu}$s, and 0.0327${\mu}$s respectively. The daily and monthly variance forms of time difference at each pair appeared in a similar reappearance. 2)The mean standard deviations of the latitude and longitude by Loran - C were 9.1m and 17.4m in W.X pair, 11.5m and 13.7m in W.Y pair, and 8.1m and 29.3m in X.Y pair respectively, and then the probable radiuses within 95% of each pair were 39.2m, 35.7m, and 60.8m, respectively. Therefore, It is to be desired that W.Y par is selected to improve the accuracy in Pusan area. 3)The mean standard deviations of the latitude and longitude by GPS were 15.4m and 15.0m and the probable radius within 95% was 43.4m. 4)The position errors for GPS and each pair of Loran - C were 16.0m to the South in GPS and 265.2m to the East in W.X pair of Loran - C, 279.5m to the North in W.Y pair of that, and 224.3m to the North-West in X.Y pair of that, so GPS is about 250m higher than Loran - C in accuracy.

  • PDF

A Study on the accuracy of Rangefinder between vessels by use of GPS (GPS를 이용한 선간거리계의 정확도에 관한 연구)

  • 김광홍
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.215-226
    • /
    • 1999
  • The experimented rangefinder consist of sets of V/A-Code GPS and sets of L1 C/A-code & carrier phase receivers connected by two spread spectrum radio modems in order to measure relative range and bearing between two ship antennas by real time, comparing and analyzing accuracy of both GPS receivers at the fix point on the land by means of executing zero baseline test by C/A code and by carrier phase as well as measuring distance range 5m, 10m, 15m between each other receivers. The results from the measurement of relative range and bearing are as follows as ;1. According to the results from zero baseline test, the average error by C/A-code receiver is less than 0.1m, which proves theories from published books but when each GPS receivers track different satellites, the range accuracy error becomes up to 100m by means of S/A. Because of this sudden wide range error, rangefinder is not appropriate at relative range measurement without additional modification of the algorism of the GPS receiver itself.2. According to relative range measurement by Carrier Phase and zero baseline test at static condition, the range error is less than 3.5cm in case that it passes more than 5 minutes after GPS sets can track simultaneously more than 6 satellites. Its main reason is understood that the phase center of antenna is bigger than geodetic antenna.3. When range measurement of two receivers from 5m, to 10m to 15m, the each range error is 0.340m, 0.190m, 0.011m and each standard variation is 0.0973m, 0.0884m, 0.0790m. The range error and standard variation are in inverse proportion to distance between two receivers. 4. L1 Carrier Phase GPS generally needs 5 minutes to fix and during this ambiguity search, the relative range and bearing angle is shown to be various.

  • PDF