• Title/Summary/Keyword: M&S system

Search Result 10,161, Processing Time 0.043 seconds

Time-based Expert System Design for Coherent Integration Between M&S and AI (M&S와 AI간의 유기적 통합을 위한 시간기반 전문가 시스템 설계)

  • Shin, Suk-Hoon;Chi, Sung-Do
    • Journal of the Korea Society for Simulation
    • /
    • v.26 no.2
    • /
    • pp.59-65
    • /
    • 2017
  • Along with the development of M&S, modeling research utilizing AI technology is attracting attention because of the fact that the needs of fields including human decision making such as defense M&S are increased. Obviously AI is a way to solve complex problems. However, AI did not consider logical time such as input time and processing time required by M&S. Therefore, in this paper we proposed a "time-based expert system" which redesigned the representative AI technology rule-based expert system. It consists of a rule structure "IF-THEN-AFTER" and an inference engine, takes logical time into consideration. We also tried logical analysis using a simple example. As a result of the analysis, the proposal Time-based Expert System proved that the result changes according to the input time point and inference time.

Study of Acquiring the Credibility for Weapon System M&S with V&V Process (검증 및 확인(V&V) 절차를 통한 무기체계 M&S 신뢰도 확보에 관한 연구)

  • Kim, Seok-Woo;Park, Sanghyuk
    • Journal of the Korea Society for Simulation
    • /
    • v.24 no.3
    • /
    • pp.1-8
    • /
    • 2015
  • Verification, Validation & Accreditation (VV&A) process is widely applied in various disciplines as a method of acquiring the credibility for M&S tools. The guideline of VV&A states that the detailed process can be established flexibly according to the needs and the availability of resources. For example, DAPA (Defense Acquisition Program Administration) guideline suggests that the accreditation process in the VV&A can be omitted if necessary. On this study, we first introduce and describe V&V process. Accreditation process is omitted due to limited time and resources. However, the proposed V&V is sufficient for our needs. Finally, we apply the proposed process of V&V to the System-Integrated Simulator of "Raybolt", Medium-Range Infantry Missile System, for the acquisition of the M&S credibility.

A Study on the Service Rates of M/M/s Multi-server Demanding Queues (Multi-server Demanding M/M/s 대기행렬의 Service Rate 변화곡선에 관한 연구)

  • Kim, Seong-Sik;Jang, Jin-Ik
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 1980
  • An exact solution technique for M/M/s multi-server demanding queue is introduced, and a general form of the curves representing service rates of the system is presented. As the number of customers in the system increases, the service rate is shown to increase initially, then decrease, and finally converge to a certain value. It is also shown that this phenomenon persists regardless of the numbers of servers and customer types.

  • PDF

A Study of Quality Control Environment of Mammography (유방촬영의 화질관리 환경에 대한 고찰)

  • Hwang, In-Sun;Kim, Young-Keun;Joo, Hyung-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.133-138
    • /
    • 2010
  • The purpose of this study was to survey and test quality control of mammography system. The conclusion of this study is as follows ; First, The rate of pass for phantom image test shows that Film-Screen mammography system(F/S) and computed mammography system(CR) is 80%, Indirect digital mammography system(DR) is 100%. Second, The test of exposure dose shows that F/S is 921 mR. CR is 1,140 mR, DR is 474 mR. The grade of this testament is CR > F/S > DR. Third, The test of average glandular dose shows that F/S is 1,336 mGy, CR is 1,635 mGy, DR is 1,26 mGy. The grade of this testament is CR > F/S > DR. Fourth, The testament of resolution shows as follows F/S is 11~13 Lp/mm, CR is 4~5 Lp/mm, and DR is 5~7 Lp/mm(F/S > DR > CR) Fifth, The survey of projection, cassette, development and reading shows that user are indifference.

  • PDF

A Novel Reference Model for Cloud Manufacturing CPS Platform Based on oneM2M Standard (제조 클라우드 CPS를 위한 oneM2M 기반의 플랫폼 참조 모델)

  • Yun, Seongjin;Kim, Hanjin;Shin, Hyeonyeop;Chin, Hoe Seung;Kim, Won-Tae
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.8 no.2
    • /
    • pp.41-56
    • /
    • 2019
  • Cloud manufacturing is a new concept of manufacturing process that works like a single factory with connected multiple factories. The cloud manufacturing system is a kind of large-scale CPS that produces products through the collaboration of distributed manufacturing facilities based on technologies such as cloud computing, IoT, and virtualization. It utilizes diverse and distributed facilities based on centralized information systems, which allows flexible composition user-centric and service-oriented large-scale systems. However, the cloud manufacturing system is composed of a large number of highly heterogeneous subsystems. It has difficulties in interconnection, data exchange, information processing, and system verification for system construction. In this paper, we derive the user requirements of various aspects of the cloud manufacturing system, such as functional, human, trustworthiness, timing, data and composition, based on the CPS Framework, which is the analysis methodology for CPS. Next, by analyzing the user requirements we define the system requirements including scalability, composability, interactivity, dependability, timing, interoperability and intelligence. We map the defined CPS system requirements to the requirements of oneM2M, which is the platform standard for IoT, so that the support of the system requirements at the level of the IoT platform is verified through Mobius, which is the implementation of oneM2M standard. Analyzing the verification result, finally, we propose a large-scale cloud manufacturing platform based on oneM2M that can meet the cloud manufacturing requirements to support the overall features of the Cloud Manufacturing CPS with dependability.

A Study on VV&A Application Method for Credibility Improvement of The DM&S for C4I Test and Evaluation (C4I체계 시험평가 국방M&S 신뢰도 향상을 위한 VV&A 적용방안 연구)

  • Kim, Kyung-Hee;Kang, Seok-Joong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.1080-1090
    • /
    • 2010
  • A study for improvement of credibility on test & evaluation result of interoperability in battle management information system which focused in C4I systems is very essential in rapid change of battle field environment. Realization of effective operation process with integration of developed IT also core factor for reducing of operational response time such as information gathering from sensor to shooter, time for commander's decision making. Therefore, by required to meet of high technical T&E, meet of complex software's user requirement, long-term system development period, system integration ability's request by various linkage of systems, it is high a M&S dependency to optimal performance, interpoerability's guarantee. Especially credibility on test & evaluation using M&S is very important. This paper will propse a VV&A applied methods using other VV&A case to improve credibility of M&S on test & evaluation.

Effect of Pressure on Solids Flow Characteristics in Recycle System of a Circulating Fluidized Bed (순환유동층 재순환부 내 고체흐름 특성에 대한 시스템 압력의 영향)

  • Kim, Sung Won;Kim, Sang Done
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.198-204
    • /
    • 2010
  • Solids flow characteristics have been determined in a pressurized solids recycle systems of silica sand particles for the application in a pressurized CFB(PCFB). The solids recycle system is composed of a downcomer(0.10 m i.d. 2.25 m high) and a loop-seal(0.10 m i.d.). The silica sand($d_p=240{\mu}m$, ${\rho}_s=2582kg/m^3$) particles were transported at room temperature and system pressure($P_{sys}$) up to 0.71 MPa using air. Solids mass flux($G_s$) increases with increasing system pressure at constant aeration rate. Pressure gradient, solids velocity and actual gas velocity increase with increasing $P_{sys}$ at constant aeration rate. The Pressure drop number($\Phi$) on pressure gradient in downcomer has been correlated with Transportation number(Tr). Pressure drop across the loop-seal increases with increasing of $G_s$ irrespective of variation of $P_{sys}$. The obtained $G_s$ and Transportation number(Tr) have been correlated with the experimental variables.

Study on the Performances of Air Flow Fate Effect on a Structured Packed Tower at Adiabatic Condition in a Liquid Lithium Chloride Cooling System

  • Bakhtiar, Agung;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.404-408
    • /
    • 2009
  • The liquid desiccant air-conditioning system has been proposed as an alternative to the conventional vapor compression cooling systems to control air humidity. The complete system of liquid desiccant air-conditioning system is consisted two main components those are humidifier (regeneration) and dehumidifier. Humidifier part is connected to the load when summer season which is the air condition is hot and humid have to be turned into comfort condition on human. This paper purpose is performances study of air flow rate effect on a structured packed tower on cooling and dehumidifier system using liquid lithium chloride as the desiccant. Experimental apparatus used in this present study is consisted of three components those are load chamber, packed tower and chiller. Load chamber’s volume is $40m^3$, and packed tower dimension is cubic with length 0.4m occupied with packed column. Totally, 15 experimental has done using 5 times repeat on each variable of air velocity that varying on 2m/s, 3m/s and 4m/s with other conditions are controlled. Air inlet initial temperature and relative humidity are set respectively on $30^{\circ}C$ and 52%, desiccant flow rate is 0.63 kg/s, desiccant temperature is $10^{\circ}C$ and desiccant concentration is 0.4. The result of this study shows that averagely, the moisture removal rate and the heat transfer rate are influenced by the air velocity. Higher air velocity will increase the heat transfer and decreasing the moisture removal rate. At adiabatic condition the air velocity of 2 m/s respectively is having the higher moisture removal rate acceleration then the air velocity of 3m/s and 4 m/s until the steady state condition.

  • PDF

A Study on Cooperative Medical Treatment System between Oriental and Western Medical Practitioners (한.양방 협진체계 개발에 관한 연구)

  • Yi, Dong-Heui;Yoo, Kyu-Soo
    • Korea Journal of Hospital Management
    • /
    • v.3 no.1
    • /
    • pp.34-61
    • /
    • 1998
  • A study on cooperative medical treatment system between oriental and western medical practitioners was conducted from March through August 1997 in order to determine a productive model of cooperation of two medical parts for treatment of patients. Questionnaires were distributed to 195 medical doctors(M.D.) and 195 doctors of oriental medicine(O.M.D.) working in clinics and hospitals in six major cities. Statistical analysis tools used for this study were frequency, t-test and multiple regression by using SPSS/P.C package. The results are summarized as follows: 1. The respondents were composed of male docotors(78%) and female doctors(22%) and 68.2% of M.D. and 97% of O.M.D. were interested in the other medical part. The doctors of both disciplines had some limitation on treatment of patients but they were reluctant to refer their patients to other doctors in different discipline. 2. M.D assumed that oriental medicine was more effective for chronic diseases, and O.M.D. thought that western medicine was more effective for acute diseases. 92.3% of O.M.D.s responded that even though they do not utilize western medical technology for diagnosis, they believed the results of diagnoses by western medical technology. 3. 60.5% of O.M. and 93.3% of O.M.D. said that cooperative medical treatment system could be necessary for patients and it would be effective for control of diseases and 69% of western medical doctors and 99% of oriental medical doctors agreed that oriental medical practice would be more effective for cerebellar vascular accidents than other diseases. 77.4% of western medical doctors and 92.3% of oriental medical doctors responded that the students of two different disciplines have to be taught on the other disciplines. 82.6% of western medical doctors and 83.3% oriental medical doctors agreed that it would be necessary to have collaborative research between scientists in two disciplines. 81.5% of M.D.s and 93.3% of O.M.D.s believed that they had prejudice and distrust on other discipline 4.90% of the doctors were not satisfied with the government medical policies on health insurance, legal matters, and health delivery system. 5. 75.4% of M.D.s and 50.2% of O.M.D.s said that two medical disciplines should be integrated, but they were skeptical on that. 75.3% of M.D.s thought that western hospitals should employ O.M.D.s Finally this study recommended that western medical students study oriental medicine and the vice versa, and M.D.s and O.M.D.s should have seminars and workshops to exchange knowledge, and experiences. It is also recommended that medical laws be revised to allow medical doctors refer the patients whom they can not handle to oriental medical doctors and the vice versa.

  • PDF

A Maintenance Design of Connected-(r, s)-out-of-(m, n) F System Using Simulated Annealing (시뮬레이티드 어닐링을 이용한(m, n)중 연속(r,s) : F 시스템의 정비모형)

  • Lee, Sangheon;Kang, Youngtai;Shin, Dongyeul
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.34 no.1
    • /
    • pp.98-107
    • /
    • 2008
  • The purpose of this paper is to present an optimization scheme that aims at minimizing the expected cost per unittime. This study considers a linear connected-(r, s)-ouI-of-(m, n):f lattice system whose components are orderedlike the elements of a linear (m, n)-matrix. We assume that all components are in the state 1 (operating) or 0(failed) and identical and s-independent. The system fails whenever at least one connected (r, s)-submatrix offailed components occurs. To find the optimal threshold of maintenance intervention, we use a simulatedannealing(SA) algorithm for the cost optimization procedure. The expected cost per unit time is obtained byMonte Carlo simulation. We also has made sensitivity analysis to the different cost parameters. In this study,utility maintenance model is constructed so that minimize the expense under full equipment policy throughcomparison for the full equipment policy and preventive maintenance policy. The full equipment cycle and unitcost rate are acquired by simulated annealing algorithm. The SA algorithm is appeared to converge fast inmulti-component system that is suitable to optimization decision problem.