• Title/Summary/Keyword: M&M

Search Result 159,966, Processing Time 0.195 seconds

Engineering Characteristics of Wet-mixing Solidified Soil in Pavement Surfacing (습식 경화교반토 포장의 공학적 특성)

  • Yoo, Ji-Hyeung;Shu, Dong-Hyuk;Lee, Seong-Won
    • International Journal of Highway Engineering
    • /
    • v.6 no.3 s.21
    • /
    • pp.1-7
    • /
    • 2004
  • Roads, like bikeways, parkways and walks, are to be just capable of supporting light traffic and traveling public, but they are required to be human friendly and environmental-oriented. Lately soil-solidifier mixture, a kind of soil-cement, has developed and has been applied to the recycling and environment-oriented pavement as the surfacing material. Soil-solidifier pavement structure has been designed by only experience. To design this pavement mechanically, it is necessary to find out basic engineering properties of soil-solidifier mixture. This study focuses on finding out mechanical characteristics of the mixture according to mixture proportions and aging. Test molds with various mixture proportions are made, and then unconfined strength tests are performed for test molds with aging of the mixture. As the result of this study, it is found that the strength of the mixture increases with amount of cement and that maximum strength is achieved at 6%$\sim$8% of the ratio of solidifier and water. The strength increase rapidly until 14 days, after then slowly. After 28 days the strength of the mixture approaches to the constant value. The heat of hydration during curing of the mixture is measured no significantly. It also shows that temperature characteristics of the mixture is similar to that of soil. Since this mixture is mixed with soil and is able to improve engineering problems in pavement due to temperature, this mixture is expected to use effectively in the environment-oriented pavement for light traffic.

  • PDF

Survery on Business of the Departments of Radiology in Health Centers (보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究))

  • Choi, Jong-Hak;Jeon, Man-Jin;Huh, Joon;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF

The Usefulness According to the Incubation Time of PTH as Prediction Index of Hypocalcemia (저칼슘혈증 예측지표로서 부갑상선 호르몬 검사반응시간에 따른 유용성)

  • Au, Doo-Hee;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.138-142
    • /
    • 2010
  • Purpose: PTH (parathyroid hormone) level is a useful index for prediction of hypocalcemia after thyroidectomy. The fast results are required for an early diagnosis of hypocalcemia. In this study, we evaluated the PTH change according to incubation time, and investigated the usefulness of hypocalcemia diagnosis of PTH results in early incubation time. Materials and Methods: The subjects were 131 patients who had taken the PTH test from July to August in 2009. All experiments were used IRMA method. PTH value were evaluated with the correlation between precision (10 times repeat) and recovery rate and at 0.5, 3, 6 and $18{\pm}2$ (below overnight) hours following incubation time. Data analysis was investigated with relationship of the sensitivity, specificity, PPV (positive predictive value) and accuracy. Results: The correlation was time-dependent with levels reaching $R^2$=0.987 at 0.5 hours, $R^2$=0.993 at 3 hours and $R^2$=0.996 at 6 hours compare to overnight levels. The precision (%CV${\pm}$SD) were $15.92{\pm}15.54$ at 0.5 hours, $6.91{\pm}7.38$ at 3 hours, $4.30{\pm}4.69$ at 6 hours and $4.59{\pm}2.59$ at overnight. The recovery rate (%Mean${\pm}$SD) were $96.8{\pm}5.44$ at 0.5 hours, $102.6{\pm}4.35$ at 3 hours, $100.7{\pm}2.56$ at 6 hours and $102.2{\pm}5.98$ at overnight. When 15 pg/ml of overnight density was set up as criteria, we measured the sensitivity, specificity and PPV, accuracy at 0.5, 3, 6 hours. The sensitivity was shown to 97.5% at all times. The specificity was 96.0% at 0.5 hours, 100% at 3 hours and 92.3% at 6 hours for control, respectively. The PPV was 86.6% at 0.5 hours, 100% at 3 hours and 92.8% at 6 hours. The accuracy was shown to 84.7% at 0.5 hours, 97.5% at 3 hours and 90.6% at 6 hours. These data were accompanied by a corresponding PTH value of overnight incubation time, which significantly correlated with early time results. Conclusion: The values of PTH at 3 hours has favorable the rate of concordance of 94.1% and may be useful for prediction of hypocalcemia, and it responses to overnight incubation PTH values. Therefore, This method may be an attractive alternative to proper treatment to stop symptom revelation by giving a calcium agent to the patient.

  • PDF

The Influence of Iteration and Subset on True X Method in F-18-FPCIT Brain Imaging (F-18-FPCIP 뇌 영상에서 True-X 재구성 기법을 기반으로 했을 때의 Iteration과 Subset의 영향)

  • Choi, Jae-Min;Kim, Kyung-Sik;NamGung, Chang-Kyeong;Nam, Ki-Pyo;Im, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.122-126
    • /
    • 2010
  • Purpose: F-18-FPCIT that shows strong familiarity with DAT located at a neural terminal site offers diagnostic information about DAT density state in the region of the striatum especially Parkinson's disease. In this study, we altered the iteration and subset and measured SUV${\pm}$SD and Contrasts from phantom images which set up to specific iteration and subset. So, we are going to suggest the appropriate range of the iteration and subset. Materials and Methods: This study has been performed with 10 normal volunteers who don't have any history of Parkinson's disease or cerebral disease and Flangeless Esser PET Phantom from Data Spectrum Corporation. $5.3{\pm}0.2$ mCi of F-18-FPCIT was injected to the normal group and PET Phantom was assembled by ACR PET Phantom Instructions and it's actual ratio between hot spheres and background was 2.35 to 1. Brain and Phantom images were acquired after 3 hours from the time of the injection and images were acquired for ten minutes. Basically, SIEMENS Bio graph 40 True-point was used and True-X method was applied for image reconstruction method. The iteration and Subset were set to 2 iterations, 8 subsets, 3 iterations, 16 subsets, 6 iterations, 16 subsets, 8 iterations, 16 subsets and 8 iterations, 21 subsets respectively. To measure SUVs on the brain images, ROIs were drawn on the right Putamen. Also, Coefficient of variance (CV) was calculated to indicate the uniformity at each iteration and subset combinations. On the phantom study, we measured the actual ratio between hot spheres and back ground at each combinations. Same size's ROIs were drawn on the same slide and location. Results: Mean SUVs were 10.60, 12.83, 13.87, 13.98 and 13.5 at each combination. The range of fluctuation by sets were 22.36%, 10.34%, 1.1%, and 4.8% respectively. The range of fluctuation of mean SUV was lowest between 6 iterations 16 subsets and 8 iterations 16 subsets. CV showed 9.07%, 11.46%, 13.56%, 14.91% and 19.47% respectively. This means that the numerical value of the iteration and subset gets higher the image's uniformity gets worse. The range of fluctuation of CV by sets were 2.39, 2.1, 1.35, and 4.56. The range of fluctuation of uniformity was lowest between 6 iterations, 16 subsets and 8 iterations, 16 subsets. In the contrast test, it showed 1.92:1, 2.12:1, 2.10:1, 2.13:1 and 2.11:1 at each iteration and subset combinations. A Setting of 8 iterations and 16 subsets reappeared most close ratio between hot spheres and background. Conclusion: Findings on this study, SUVs and uniformity might be calculated differently caused by variable reconstruction parameters like filter or FWHM. Mean SUV and uniformity showed the lowest range of fluctuation at 6 iterations 16 subsets and 8 iterations 16 subsets. Also, 8 iterations 16 subsets showed the nearest hot sphere to background ratio compared with others. But it can not be concluded that only 6 iterations 16 subsets and 8 iterations 16 subsets can make right images for the clinical diagnosis. There might be more factors that can make better images. For more exact clinical diagnosis through the quantitative analysis of DAT density in the region of striatum we need to secure healthy people's quantitative values.

  • PDF

The Usefulness of Q.Clear Technique in PET / CT (PET/CT 검사에서 Q.Clear 기법의 유용성에 대한 고찰)

  • Choi, Yong Hoon;Kim, Jung Yul;Choi, Young Sook;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.31-36
    • /
    • 2017
  • Purpose Recently, the performance of PET/CT scanner has been improved and various techniques have been developed to increase the image quality such as Sensitivity and Resolution. The purpose of this study is to evaluate the usefulness of Q.Clear (a fully convergent iterative reconstruction) technique of GE Discovery IQ equipment to enhance the image quality. Materials and Methods All scans were acquired by Discovery IQ (GE Healthcare, MI, USA). In NEMA IEC Body Phantom test, Background to Hot-sphere (10 mm, 13 mm, 17 mm, 22 mm) ratio was 1:4 and scan time was 3 minutes. The images were reconstructed by VPHDs (VUE Point High-Definition + SharpIR) and Q.Clear to evaluate each Contrast. We injected 18F-FDG 187 M㏃ to PET/SPECT Performance Phantom. And then it was scanned for 4 minutes to evaluate Resolution and Uniformity. T-test statistical analysis was performed on SUVmax of small lesions less than 2 cm in 100 clinical patients regardless of disease type. Results In the NEMA IEC Body Phantom, the Contrast was $63.6{\pm}5.7%$ (VPHDs) and $75{\pm}4.8%$ (Q.Clear). In the PET/SPECT Performance Phantom, the Resolution was 9.2 mm (VPHDs) and 7.3 mm (Q.Clear). Uniformity of Q.Clear was 10.8% better than VPHDs. T-test statistic of the clinical patients showed a significant difference of p value of 0.021. Conclusion Both the phantom test and the clinical results showed that the quality of the image was improved in Q.Clear was applied. The SUVmax was highly measured in Q.Clear and the lesions were clearly distinguished visually. Therefore Q.Clear can be useful in various aspects such as dose-reduction, patients evaluation and image analysis.

  • PDF

Effect of Acupuncture on the Expressions of Neuropeptide Y and Leptin Receptor in the Hypothalamus of Food-deprived Rats (침치료가 굶긴 쥐 시상하부에서 neuropeptide Y(NPY)와 leptin receptor(LR)의 발현에 미치는 영향에 대한 실험적 연구)

  • Kim, Mi-A;Jung, Woo-Sang;Moon, Sang-Kwan;Kim, Young-Suk;Kim, Chang-Ju;Cho, Ki-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.34 no.2
    • /
    • pp.113-121
    • /
    • 2013
  • Objectives : This study aimed to find out whether acupuncture at various acupoints shows any effects on appetite by regulating neurotransmitters in the hypothalamus through the expression of NPY and LR in the PVN via immunohistochemistry. Methods : Male Sprague-Dawley rats were divided into eight groups of five mice each. The rats in the acupuncture groups were treated with acupuncture at respective acupoints, twice per a day for 3 days. The animals were sacrificed 72 h after commencement of the experiment, the brains being dissected into serial coronal sections. Expressions of neuropeptide Y and leptin receptor in the hypothalamus were assessed by immunohistochemistry. Results : NPY expression in the PVN was enhanced and LR expression in the PVN was decreased by food deprivation. NPY immunoreactivity in the PVN of the food-derived rats was decreased by acupuncture at the auricular acupoint, Zusanli-acupoint, a and non-acupoint. However, acupuncture at the auricular acupoint showed most potent suppressing effect on NPY expression in the PVN of food-deprived rats. LR expression in the PVN decreased following food deprivation, and auricular acupuncture increased LR expression in the PVN of food-deprived rats. In normal conditions (fed state), LR expression in the PVN was not changed by acupuncture treatment at several sites. Conclusions : From this study, we have shown that acupuncture at the auricular acupoint exerts the most potent appetite suppressing effect on the food restriction state.

Improvement of Patient Safety and Inspection Satisfaction by Developing Pretreatment Process System with the Patients Who Reserved CT Enhance Examination (CT 조영검사 예약환자의 전처치 프로세스 시스템 개발을 통한 환자안전 및 검사 만족도 향상)

  • Beom, Hyinam;Han, Jaebok;Song, Jongnam;Kim, Wook;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • This study aims to improve the satisfaction level of the patient who undergoes CT contrast examination by developing and applying pretreatment process system, which not only can reduce the side effects caused by the test but also can help carry out the test smoothly. The subjects were 214 patients who booked CT contrast examination from January 2014 to February 2014 but could not carry out their test on schedule. We analyzed the reasons for the delay and conducted follow-up survey on them. We analyzed the usefulness of pretreatment process system by contemplating and developing pretreatment process system and applying it to the patients for whom follow-up survey was conducted from January 2015 to February 2015. The number of outpatients who came to the hospital form January to February 2014 was 2,846 and the number of patients who could not undergo the test was 214, accounting for 7.52% of the total. The specific reason for the delay includes 214 cases of unknown creatinine 98 with 120 minutes of average delay time, 40 cases of creatinine over 1.3(19%) with 30minutes of average delay time, 34 cases of past contrast media side effect 6% with 40 minutes of average delay time and 25 cases of lack of pretreatment such as fasting, etc. 11% with 120minutes of average delay time. The number of CT scan has been increasing ever since the development of CT and the frequency of using the contrast media is expected to increase. If we can employ pretreatment process system in order to effectively control the side effect of contrast media and help the CT contrast examination to be smoothly conducted on schedule, I'm sure we could improve the quality of our medical service and increase our patients' satisfaction who come to our CT scan room.

The Clinical Usefulness of Serum Aminotransferase Activities for Predicting Fatty Liver in Obese Children (비만아에서 지방간의 예측 인자로서 혈청 Aminotransferase의 임상적 유용성)

  • Lim, Seon-Woong;Jeon, Myeong-Won;Park, Sin-Ae;Choi, Kyeong-Dan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.6 no.2
    • /
    • pp.174-182
    • /
    • 2003
  • Purpose: Non-alcoholic fatty liver disease (NAFLD) has been recognized as an important childhood liver disease, especially where the prevalence of childhood obesity is increasing. The purpose of this study is to clarify the usefulness of elevated serum aminotransferase activities and their ratio for predicting the presence of fatty liver and its severity in obese children. Methods: Forty-four children (M/F 29/15, age 4 to 16 years) with obesity (weight excess>20%) were analyzed retrospectively with medical records based on degree of obesity, bioelectrical impedence, serum aminotransferase activities, lipid profiles and ultrasonography. Results: 1) Ultrasonography was carried out in 34 cases. Elevated serum ALT was found in 89.7% (26/29) of the patients diagnosed as fatty liver by ultrasonography and decreased AST/ALT ratio (<1) was found in 96.6% (28/29). There was a strong correlation between elevated serum ALT (>45 IU/L) or decreased AST/ALT ratio (<1) and the fatty liver in obese children (p<0.05). 2) There was no significant correlation between the serum ALT or AST/ALT ratio and the degree of fatty liver (p>0.05). 3) There was a significant correlation between total cholesterol, triglyceride and fatty liver (p<0.05). Conclusion: Serum ALT activity and AST/ALT ratio were useful to predict the presence of fatty liver diagnosed by ultrasonography in obese children, whereas they were not useful to predict the degree of fatty liver. Therefore, to prevent fatty liver progressing to advanced liver disease, it is necessary to manage and monitor the obese children continuously, especially those who have predicting factors of fatty liver.

  • PDF

The Relationship between Lifestyle and Metabolic Syndrome in Obese Children and Adolescents (소아청소년 비만에서 생활습관과 대사증후군의 연관성)

  • Cho, Ky-Young;Park, Hye-Sook;Seo, Jeong-Wan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.2
    • /
    • pp.150-159
    • /
    • 2008
  • Purpose: To assess the relationship between lifestyle and metabolic syndrome in obese children and adolescents. Methods: We retrospectively reviewed the medical records and laboratory results of 109 subjects (7~15 years of age) who visited our pediatric obesity clinic between January 2004 and December 2007. They completed the parent- and self-report questionnaire developed by the Committee on Nutrition of the Korean Pediatric Society to assess lifestyle. The metabolic syndrome was defined as having 3 or more of the following metabolic risk factors: obesity, hypertension, serum triglycerides ${\geq}$110 mg/dL, HDL-cholesterol ${\leq}$40 mg/dL, fasting glucose ${\geq}$110 mg/dL, and insulin ${\geq}20{\mu}IU/mL$. Results: All subjects had at least 1 risk factor (obesity). Sixty-three percent of subjects had 2 or more risk factors, 32% of subjects had 3 or more risk factors, and 10% had 4 or more metabolic risk factors. Hypertriglyceridemia (36%), hypertension (32%), hyperinsulinemia (24%), and HDL-hypocholesterolemia (20%) were observed. Fasting blood glucose levels were normal in all subjects. Hypertension was significantly associated with an unbalanced diet and hyperinsulinemia was significantly associated with parental obesity (p<0.05). Those who ate after 8 PM were at a risk of hypertension (odds ratio, 2.5; 95% CI, 1.0~6.1). Those who did not have a preference for exercise were at a risk of hyperinsulinemia (odds ratio, 10.4; 95% CI, 2~54.1). Those who watched TV for ${\geq}$3 hours/day were at a risk of metabolic syndrome (odds ratio, 4.8; 95% CI, 1.2∼18.8). Conclusion: Lifestyle, such as eating late, no preference for exercise, and TV watching ${\geq}$3 hours/day, were related to metabolic syndrome in obese children and adolescents.

  • PDF

Development of Neural Network Based Cycle Length Design Model Minimizing Delay for Traffic Responsive Control (실시간 신호제어를 위한 신경망 적용 지체최소화 주기길이 설계모형 개발)

  • Lee, Jung-Youn;Kim, Jin-Tae;Chang, Myung-Soon
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.3 s.74
    • /
    • pp.145-157
    • /
    • 2004
  • The cycle length design model of the Korean traffic responsive signal control systems is devised to vary a cycle length as a response to changes in traffic demand in real time by utilizing parameters specified by a system operator and such field information as degrees of saturation of through phases. Since no explicit guideline is provided to a system operator, the system tends to include ambiguity in terms of the system optimization. In addition, the cycle lengths produced by the existing model have yet been verified if they are comparable to the ones minimizing delay. This paper presents the studies conducted (1) to find shortcomings embedded in the existing model by comparing the cycle lengths produced by the model against the ones minimizing delay and (2) to propose a new direction to design a cycle length minimizing delay and excluding such operator oriented parameters. It was found from the study that the cycle lengths from the existing model fail to minimize delay and promote intersection operational conditions to be unsatisfied when traffic volume is low, due to the feature of the changed target operational volume-to-capacity ratio embedded in the model. The 64 different neural network based cycle length design models were developed based on simulation data surrogating field data. The CORSIM optimal cycle lengths minimizing delay were found through the COST software developed for the study. COST searches for the CORSIM optimal cycle length minimizing delay with a heuristic searching method, a hybrid genetic algorithm. Among 64 models, the best one producing cycle lengths close enough to the optimal was selected through statistical tests. It was found from the verification test that the best model designs a cycle length as similar pattern to the ones minimizing delay. The cycle lengths from the proposed model are comparable to the ones from TRANSYT-7F.