• Title/Summary/Keyword: M&As

Search Result 74,576, Processing Time 0.106 seconds

Treatment Characteristics of Trichloroethylene(TCE) by Oxidation and Reduction with Nanoscale Zero-valent Iron (나노영가철의 산화·환원에 의한 트리클로로에틸렌 처리특성)

  • Park, Young-Bae;Jung, Yong-Jun;Choi, Jeong-Hak;Moon, Boung-Hyun
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.903-910
    • /
    • 2014
  • This study examined the treatment characteristics of hard-to-degrade pollutants such as TCE which are found in organic solvent and cleaning wastewater by nZVI that have excellent oxidation and reduction characteristics. In addition, this study tried to find out the degradation characteristics of TCE by Fenton-like process, in which $H_2O_2$ is dosed additionally. In this study, different ratios of nZVI and $H_2O_2$, such as 1.0 mM : 0.5 mM, 1.0 mM : 1.0 mM, and 1.0 mM : 2.0 mM were used. When 1.0 mM of nZVI was dosed with 1.0 mM of $H_2O_2$, the removal efficiency of TOC was the highest and the first order rate constant was also the highest. When 1mM of nZVI was dosed with 0.5 mM of $H_2O_2$, the first order rate constant and removal efficiency were the lowest. The size of first order rate constant and removal efficiency was in the order of nZVI 1.0 mM : $H_2O_2$ 1.0 mM > nZVI 1.0 mM : $H_2O_2$ 2.0 mM > nZVI 1.0 mM : $H_2O_2$ 0.5 mM > $H_2O_2$ 1.0 mM > nZVI 1.0 mM. It is estimated that when 1.0 mM of nZVI is dosed with 1.0 mM of $H_2O_2$, $Fe^{2+}$ ion generated by nZVI and $H_2O_2$ react in the stoichiometric molar ratio of 1:1, thus the first order rate constant and removal efficiency are the highest. And when 1.0 mM of nZVI is dosed with 2.0 mM of $H_2O_2$, excessive $H_2O_2$ work as a scavenger of OH radicals and excessive $H_2O_2$ reduce $Fe^{3+}$ into $Fe^{2+}$. As for the removal efficiency of TOC in TCE by simultaneous dose and sequential dose of nZVI and $H_2O_2$, sequential dose showed higher first order reaction rate and removal efficiency than simultaneous dose. It is estimated that when nZVI is dosed 30 minutes in advance, pre-treatment occurs and nanoscale $Fe^0$ is oxidized to $Fe^{2+}$ and TCE is pre-reduced and becomes easier to degrade. When $H_2O_2$ is dosed at this time, OH radicals are generated and degrade TCE actively.

The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen (복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Je-Bong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • 1. Purpose : This study is to present effective exposure conditions to acquire the best image of simple abdomen in Film Screen (F.S) system and Computed Radiography (C.R) system. 2. Method : In the F.S system, while an exposure condition was fixed as 70kVp, images of a patients simple abdomen were taken under the different mAs exposure conditions. Among these images, the best one was chosen by radiologists and radiological technologists. In the C.R system, the best image of the same patient was acquired with the same method from the F.S system. Both characteristic curves from F.S system and C.R system were analyzed. 3. Results : In the F.S system, the best exposure condition of simple abdomen was 70kVp and 20mAs. In the CR system, with the fixed condition at 70kVp, the image densities of human organs, such as liver, kidney, spleen, psoas muscle, lumbar spine body and iliac crest, were almost same despite different environments (3.2mAs, 8mAs, 12mAs, 16mAs and 20mAs). However, when the exposure conditions were over or under (below) 12mAs, the images between the abdominal wall and the directly exposed part became blurred because the gap of density was decreased. In the C.R system, while the volume of mAs was decreased, an artifact of quantum mottle was increased. 4. Conclusion : This study shows that the exposure condition in the C.R system can be reduced 40% than in the F.S system. This paper concluded that when the exposure conditions are set in CR environment, after the analysis of equipment character, such as image processing system(EDR : Exposure Data Recognition processing), PACS and so on, the high quality of image with maximum information can be acquired with a minimum exposure dose.

  • PDF

Chinese SOEs and the Completion of Cross-border M&As: The Moderating Role of M&A Experience

  • Luo Jing;Young-Gon Cho;Jaekyung Ko
    • Journal of Korea Trade
    • /
    • v.26 no.6
    • /
    • pp.118-135
    • /
    • 2022
  • Purpose - The purpose of this study is to investigate the relationships among Chinese state-owned enterprises (SOEs), previous M&A experience, and the probability of deal completion in cross-border mergers and acquisitions (CBMAs). Since Chinese SOEs tend to be recognized by host countries as agents of their home country government, this study argues that SOEs will face difficulties in completing CBMA deals. However, the study expects that these difficulties may vary depending on whether the firm has previous M&A experience because firms can gain the knowledge and capabilities necessary to implement subsequent M&As successfully from past M&A experience. Design/methodology - To investigate our argument, we conduct a logistic regression using a sample of 363 CBMA deals from 304 Chinese publicly listed firms during 2007 to 2017. We used SOEs as an independent variable, experience of domestic and foreign M&As as moderating variables, respectively, and CBMA deal completion as the dependent variable. Findings - The study shows a negative and significant relationship between Chinese SOEs and the completion likelihood of CBMA deals. We find that this negative relationship is strengthened when the firm had prior domestic M&A experience, whereas foreign M&A experience alleviated the negative relationship. Originality/value - The issue of government ownership has remained unclear since government intervention has both advantages and disadvantages in pursuing CBMAs. Our findings support literature that argues Chinese SOEs face legitimacy concerns in the host countries, thereby lowering their CBMA deal completion likelihood. Furthermore, the study enriches the literature by identifying different moderating effects of domestic and foreign M&A experience on the negative relationship between SOEs and CBMA deal completion.

Smart Phone and Vehicle Authentication Scheme with M2M Device (M2M 기기에서 스마트폰 및 차량 인증 기법)

  • Yeo, Seong-Gwon;Lee, Keun-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.4
    • /
    • pp.1-7
    • /
    • 2011
  • As the developing of the information technology, M2M market that is using communication between devices is growing rapidly and many companies are involved in M2M business. In this paper, the concept of telematics and vulnerabilities of vehicle network security are discussed. The convergence of vehicle and information technology, the development of mobile communication technology have improved quality of service that provided to user but as a result security threats has diverse. We proposed new business model that be occurred to the participation of mobile carriers in telematics business and we analyzed mobile radio communication network security vulnerabilities. We proposed smart phone and Vehicle authentication scheme with M2M device as a way to solve vulnerabilities.

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

플라즈마를 이용한 GaAs 반응성 이온 식각

  • Lee, Seong-Hyeon;No, Ho-Seop;Choe, Gyeong-Hun;Park, Ju-Hong;Jo, Gwan-Sik;Lee, Je-Won
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.26.2-26.2
    • /
    • 2009
  • 이 논문은 반응성 $BCl_3$ 플라즈마로 GaAs의 건식 식각을 진행한 후 그 결과에 대하여 연구 분석 한 것이다. 이 때 사용한 식각 공정 변수는 $BCl_3$ 플라즈마에서의 가스유량, 공정 압력과 RIE 척 파워의 변화이다. 먼저 공정 압력을 75 mTorr 고정시킨 후 $BCl_3$ 유량을 변화 (2.5~10 sccm)해서 실험하였다. 또한 BCl3의 유량을 5 sccm으로 고정시킨 후 공정압력을 변화(47~180 mTorr)해서 식각 실험을 실시하였다. 마지막으로 47 mTorr와 100 mTorr 의 각각의 공정압력에서 RF 척 파워를 변화시켜 (50~200 W) 실험하였다. GaAs 플라즈마 식각이 끝난 후 표면단차 측정기 (Surface profiler)를 사용하여 표면의 단차와 거칠기를 분석하였다. 그 후 그 결과를 이용하여 식각율 (Etch rate), 식각 표면 거칠기 (RMS roughness), 식각 선택비 (Selectivity) 등의 식각 특성평가를 하였다. 또한 식각 공정 중에 샘플 척에 발생하는 자기 바이어스와 $BCl_3$ 플라즈마 가스를 광학 발광 분석기 (Optical Emission Spectroscopy)를 이용하여 플라즈마의 상태를 실시간으로 분석하였다. 이 실험 결과에 따르면 공정 압력의 증가는 샘플 척의 자기 바이어스의 값을 감소시켰다. $BCl_3$ 압력 변화에 의한 GaAs의 식각 결과를 정리하면 5 sccm의 $BCl_3$ 가스유량과 RF 척 파워를 100 W로 고정시켰을 때 식각율은 47 mTorr에서 가장 높았으며, 그 값은 $0.42{\mu}m/min$ 이었다. GaAs의 식각 속도는 공정압력이 증가할수록 감소하였으며 180 mTorr에서는 식각율이 $0.03{\mu}m/min$로 거의 식각되지 않았다. 또한 공정압력을 75 mTorr, RF 척 파워를 100 W로 고정시키고, $BCl_3$ 가스유량을 2.5 sccm에서 10 sccm까지 변화시켰을 때, 10 sccm 의 $BCl_3$ 가스유량에서 가장 높은 식각율인 $0.87{\mu}m/min$이 측정되었다. 압력에 따른 GaAs의 식각 후 표면 거칠기는 최대 2 nm 정도로 비교적 매끈하였으며, 거의 식각되지 않은 180mTorr의 조건에서는 약 1 nm로 낮아졌다. 본 실험 조건에서 GaAs의 감광제에 대한 식각 선택비는 최대 약 3:1 이내였다.

  • PDF

A Study on the sound characteristic and B.M.I by Sasang Constitution (사상체질별 음향특성(音響特性)과 신체질량지수(BMI)에 관(關)한 연구(硏究))

  • Kim, Dal-Rae
    • Journal of Sasang Constitutional Medicine
    • /
    • v.16 no.1
    • /
    • pp.53-60
    • /
    • 2004
  • Purpose This study is to find the characteristics of voice quality based on the classifying the sound characteristics and B.M.I. by Sasang Constitution. Methods To make the notion of the consensus of Sasang Constitution's Voice, classification into 4 categories was made: clear/hoarse, high/low, powerful/powerless, fast/slow. Result The voice quality of Soyangin group was classified as powerful and fast, and that of Taeumin group was classified as powerful and hoarse and low, and that of Soeumin group was classified as powerless and clear. The mean B.M.I. of Soeumin group was classified as 21.4, and that of Taeumin group was classified as 26.3. Conclusion 1. Taeumin was significantly high compared with Soeumin in B.M.I. 2. It can be classified as Taeumin when B.M.I. is high(26.3). 3. It can be classified as Soeumin when B.M.I. is low(21.4). 4. The voice quality of Soyangin group was classified as clear and fast, or strong and clear, and that of Taeumin group as powerful and hoarse, and that of Soeumin group as powerless and low.

  • PDF

Kinetic Analysis of Purine Nucleoside Phosphorylase in Saccharomyces cerevisiae (Saccharomyces cerevisiae에서 얻은 Purine Nucleoside Phosphorylase의 반응 속도론적 분석)

  • Choi, Hye-Seon
    • Korean Journal of Microbiology
    • /
    • v.31 no.2
    • /
    • pp.148-156
    • /
    • 1993
  • Kinetic parameters of purine nucleoside phosphorylase (PNP) from Saccharomyces cerevisiae were measured. The Michaelis constants determined for substrates of the enzyme were $ 2.0 * 10^{-4}$ M for inosine, $2.0 *10^{-3}$ M for deoxyinosine, $ 2.0 * 10^{-5}$ M for guanosine and $2.0 10 ^{-5}$ M for deoxyguanosine. According to the ratio of relative $K_{cat}$Km, substrate specificity of each nucleoside was in the order of guanosine or deoxyguanosine, inosine and deoxyinosine. Cosubstrate, phosphate, revealed downward curvature in Lineweaver-Burk plot at high concentrations, indicating a negative cooperativity between subunits. The inhibition constants for purine analogs were measured to be $ 6 * 10^{-4}$ M for formycin B as the competitive inhibitor of inosine, $ 9 * 10^{-6}$ M for guanine as the competitive inhibitor of guanosine, $2 * 10^{-4}$ M for hypoxanthine as the non competitive inhibitor of guanosine and $4.5 * 10 ^{-4}$ M for 6-mercaptopurine as the non competitive inhibitor of guanosine. Alternative substrates, guanosine, deoxyguanosine and adenosine were found to act as competitive inhibitors with Ki values o $f^ 2.0 * 10 {-5}$ M, $2.6 * 10^{-5}$ M and $8.5 * 10 ^{-4}$ M, respectively, when inosine was the variable substrate. Guanosine and deoxyguanosine were also observed as competitive inhibitors with the Ki values of $1.8 * 10^{-5}$ M and $ 3.0 * 10^{-5}$ M, respectively, when deoxyinesine was the variable substrate. The results of alternative substrate sstudies suggested that a single enzyme acted on different nucleosides, inosine, deoxyinosine, adenosine, guanosine and deoxyguanosine.e.

  • PDF

Study on the Change of Absorbed Dose and Image Quality according to X-ray Condition of Detector in Digital Radiography(DR) (Digital Radiography(DR)에서 검출기의 X선 조건에 따른 흡수선량 및 영상화질 변화에 관한 연구)

  • Hwang, Jun-Ho;Jeong, Jae-Ho;Kim, Hyun-Soo;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.9
    • /
    • pp.99-106
    • /
    • 2017
  • This study focused on the issue that when a diagnostic detector is found to have a defect, a patient would be exposed to radiation and image quality would be degraded. Though dose analysis, an experiment was conducted to evaluate detector performance as Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR). Absorbed dose, SNR and CNR were measured using a dosimeter and a tissue equivalent phantom. The experiment was conducted to compare whether the dose value shown after being attached to the back side of the phantom matches the dose value attached behind the detector, where in the conditions of skull, chest and abdomen were set at 75 kVp, 25 mAs, 110 kVp, 8 mAs, and 80 kVp, 20 mAs, respectively. As a result, there was a difference in that the dose values attached to the back side of the detector were 0.004 mGy, 0.006 mGy, 0.003 mGy, whereas those of the back side of the phantom were 0.006 mGy, 0.016 mGy, 0.017 mGy. In order to match both values, the condition was increased and SNR and CNR also increased from 88.32, 88.10, 4.09, 1.63, 87.94, 79.97 to 93.87, 93.75, 4.91, 4.03, 92.02, 84.92. Though this study, we found that when a detector is found to have a aging, it shortens the life of equipment and increases the dose of a patient, also the improvement effect of image quality is inadequate.

Matrix Modification for Graphite Furnace Atomic Absorption Spectrophotometric Determination of Volatile Elements(III) Trace Bismuth

  • Kim, Young-Sang;Choi, Jong-Moon;Kim, Young-Man
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.435-442
    • /
    • 1995
  • A matrix modification was studied for the determination of trace bismuth in water samples by graphite furnace atomic absorption spectrophotometry. The type and quantity of modifiers as well as the use of auxiliary modifiers were investigated to realize the efficient modification. Palladium was chosen as a single modifier. By the addition of palladium($5{\mu}g/mL$) to 100 ng/mL bismuth solution, the temperatures could be raised from $500^{\circ}C$ to $1,300^{\circ}C$ for the charring and from $2,000^{\circ}C$ to $2,200^{\circ}C$ for the atomization as well as the sensitivity and reproducibility were improved. The absorbance of bismuth was maximum and not changed in the range of Pd $3-25{\mu}g/mL$. And several materials were examined as an auxiliary modifier. The mixed solution of $1{\mu}g/mL$ palladium and $200{\mu}g/mL$ nickel have raised the temperatures as with $5{\mu}g/mL$ palladium only. The maximum absorbance of bismuth was shown in the nickel concentration range of $100-300{\mu}g/mL$ in $1{\mu}g/mL$ palladium modified system. With such optimum conditions, the trace amount of bismuth in several water samples could be determined by a calibration curve method, and good recoveries were also obtained.

  • PDF