• Title/Summary/Keyword: M&As

Search Result 74,739, Processing Time 0.078 seconds

Case Study on Decision-Making Process for M&A in Small and Medium Companies (중소기업 M&A 의사결정 과정에 관한 연구)

  • Jung, Han-Seok;Moon, Jae-Seung
    • Journal of Distribution Science
    • /
    • v.13 no.10
    • /
    • pp.65-72
    • /
    • 2015
  • Purpose - A rapidly changing business environment places great demands on small and medium-sized enterprises (SMEs). These SMEs need to find strategic alternatives for continued growth and, ultimately, survival. Thus, mergers and acquisitions (M&A) are deemed an acceptable solution. Research to date has dealt with M&A in major organizations and focused on post merger integration (PMI). Our study focuses on SMEs, as they are relatively new and unknown to the public. Therefore, this study highlights successful M&A and decision making for SMEs through a case study analysis. Research design, data, and methodology - For this study, we examined an M&A case between company S, which produces cell phone parts, and company P, which produces SSD cases. We reviewed theories and previous studies in M&A literature. We comprehensively examined the decision-making procedure at each M&A stage, describing the situation of the buying company and the selling company from the period of the M&A announcement through deal completion. In addition, we conducted interviews with both companies. The data regarding this case study were collected through interviews with managers of both companies who actively participated in the M&A process. When necessary, we asked them about additional relevant information during the interviews. Results - The result of the M&A between company S and company P was deemed acceptable with the exception of the long negotiation period. However, company S was not able to prepare for PMI after the acquisition due to a controversy over acquisition values. Moreover, the employees of the newly formed company, especially those who came from company P, complained about the M&A and attempted to leave. Thus, implications for successful M&As of SMEs are as follows: First, the procedural compliance of the M&A is needed. Second, support is needed from the CEO for the working group, rather than excessive intervention during due diligence. Third, the right, talented members of the organization should be part of the process of the M&A. Fourth, the use of various types of outside expert or business consultants is needed. Fifth, the strategic intervention by Human Resource managers is required. Last, sharing M&A information among employees is important as information dissemination will help employees be more receptive to such a change. However, this study has several limitations as a single case study; more varied SME M&A case studies are needed in order to generalize the results of the study. Conclusions - Most of the research dealing with M&As has focused on major companies and PMI and neglected SMEs. Thus, our study focuses on SMEs and the decision-making procedures for M&A. This study has significantly contributed to the literature in this area and has provided practical information around the implications of sound decision-making during M&As. Specifically, the results of the study contribute to the need for research on M&A among SMEs, which to date has often been neglected as a topic of choice.

Evaluation for Optimization of CT Dose Reduction Methods in PET/CT (PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2015
  • Purpose Various methods for reducing radiation exposure have been continuously being developed. The aim of this study is to evaluate effectiveness of dose reduction, image quality and PET SUV changes by applying combination of automatic exposure dose(AEC), automated dose-optimized selection of X-ray tube voltage(CAREkV) and sinogram affirmed iterative reconstruction(SAFIRE) which can be controled by user. Materials and Methods Torso, AAPM CT performance and IEC body phantom images were acquired using biograph mCT64, (Siemens, Germany) PET/CT scanner. Standard CT condition was 120 kV, 40 mAs. Radiation exposure and noise were evaluated by applying AEC, CAREkV(120 kV, 40 mAs) and SAFIRE(120 kV, 25 mAs) with torso phantom compare to standard CT condition. And torso, AAPM and IEC phantom images were acquired with combination of 3 methods in condition of 120 kV, 25 mAs to evaluate radiation exposure, noise, spatial resolution and SUV changes. Results When applying AEC, CTDIvol and DLP were decreased by 50.52% and 50.62% compare to images which is not applying AEC. mAs was increased by 61.5% to compensate image quality according to decreasing 20 kV when applying CAREkV. However, CTDIvol and DLP were decreased by 6.2% and 5.5%. When reference mAs was the lower and strength was the higher, reduction of radiation exposure rate was the bigger. Mean SD and DLP were decreased by 2.2% and 38% when applying SAFIRE even though mAs was decreased by 37.5%(from 40 mAs to 25 mAs). Combination of 3 methods test, SD decreased by 5.17% and there was no significant differences in spatial resolution. And mean SD and DLP were decreased by 6.7% and 36.9% compare to 120 kV, 40 mAs with AEC. For SUV test, there was no statistical differences(P>0.05). Conclusion Combination of 3 methods shows dose reduction effect without degrading image quality and SUV changes. To reduce radiation exposure in PET/CT study, continuous effort is needed by optimizing various dose reduction methods.

  • PDF

쌍끌이 중층트롤어법의 연구 ( 1 ) - 모형어구의 망구형상에 관하여 - ( A Study on the Pair Midwater Trawling ( 1 ) - Mouth Performance of the Model Net - )

  • 이병기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.1
    • /
    • pp.29-44
    • /
    • 1995
  • A model experiment on the pair midwater trawl net applicable to 800 PS class Korean pair bottom trawlers was carried out in the special-prepared experimental thank. the tank was prepared as a reverse trapezoid shape in its vertical section by digging out flat soil. The dimension of the tank showed the 9.6 W$\times$43.0 L(m) of the upper fringe and the 4.8 W$\times$38.0 L(m) of the bottom with 3.0m in depth. The depth of water was maintained 2.7m during experiment. The model net was prepared based on the Tauti's similarity law of fishing gear in 1/30 scale considering the dimension of the experimental tank. Mouth performance of the model net during towing were determined by the photographs taken in front of the net mouth with the combinations of towing velocity, warp length and distance between paired boats. The results obtained can be summarized as follows: 1. Vertical opening of the model nets A and B was varied in the range of 0.18~0.88 m and 0.21~0.78 m (which can be converted into 5.4~26.4m and 6.3~23.4 m in the full-scale net) respectively, and was varied predominantly by towing speed. Vertical opening (H which is appendixed m for the model net. f for the full-scale net. A and B for the types of the model net) can be expressed as the function of towing velocity$V_t$as in the model net $V_t$ : m/ sec)$H_{mA}$=1.67$e^{-1.65V_t}$ $H_{mB}$=1.15$e^{-1.13V_t}$, in the full-scale net ($V_t$ : k't) $H_{fA}$=50.27$e^-0.37V_t$ $H_{fB}$=34.46$e^{-0.26Vt}$. 2. Horizontal opening of the model nets An and b was varied in the range of 1.03~1.54m and 1.04~1.55 m (which can be converted into 30.9~46.2 m and 31.2~46.5m in the full-scale net) respectively, and was varied predominantly by distance between paired boats. Horizontal opening (W, appendixes are as same as the former) an be expressed as the function of distance between paired boats $D_b$as in the model net $W_{mA}$=0.69+0.09$D_b$ $W{mB}$=0.73+0.09$D_b$, in the full-scale net $W_{fA}$=20.81+0.09$D_b$ $W_{fB}$=22.11+0.09$D_b$ 3. Net opening area of the model net A and B was varied in the range of 0.28~1.04 $m^2$ and 0.33~0.94$m^2$(which can be converted into 252~936$m^2$ and 297~846$m^2$ in the full-scale net) respectively, and was varied predominantly by towing velocity. Net opening area ($S$, appendixes are as same as the former) van be expressed as the function of towing velocity$V_t$ as in the model net $v_t$ : m/sec) $S_{Ma}$=2.01$e^{-1.54V_T}$ $S_{mA}$=1.40$e^{-1.65V_t}$, in the full-scale net ($V_t$ : k't) $S_{fA}$=1.807$e^-0.35V_t$ $S_{fA}$=1.265$e^{-0.24V_t}$. 4. Filtering volume of the model nets A and B was varied in the range of 0.32~0.55 $m^3$ and 0.37~0.55$m^3$(which can be converted into 8.640~14.850 $m^3$ and 9.990~14.850$m3$in the full~scale net) respectively, and was predominantly varied by towing speed. filtering volume of the model net-A showed the maximum at the towing speed 0.69 m/sec(3 k't in the full-scale net), compared with that of the model net B showed at 0.92 m/sec(4 k't in the full-scale net).

  • PDF

Differential Response in Ethylene Evolution and Membrane Permeability Between Rice Cultivars as Affected by Oxyfluorfen (Oxyfluorfen 내성 수도품종의 Ethylene 발생 및 세포막삼투성 차이)

  • 구자옥;이영만
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.33 no.4
    • /
    • pp.375-379
    • /
    • 1988
  • To identify the evidence in tolerance to oxyfluorfen between selected rice cultivars (cv. Chokoto as the tolerant and cv. Weld Pally as the susceptible), the differences in ehtylene evolution, chlorophyll contents and electro-conductivity as affected by various concentrations of oxyfluorfen were assessed. -Under 10$^{-5}$ M oxyfluorfen, the susceptible cultivar showed rapid and higher rate of ethylene evolution, and under 10$^{-4}$ M oxyfluorfen, less difference in ethylene evolution between both cultivars. -Upto 10$^{-6}$ M oxyfluorfen, no difference in chlorophyll contents of both cultivars, however, at 10$^{-5}$ ~10$^{-4}$ M, the susceptible showed as less chlorophyll contents as half of the tolerant. At 10$^{-3}$ M, both cultivars showed complete decomposition of chlorophyll. -At 10$^{-4}$ ~10$^{-3}$ M oxyfluorfen. both cultivars indicate the increased rate in electro-conductivity, and the susceptible cultivar released as much electrolytes as 10% of the tolerant.

  • PDF

A study on the InGaAsP/InP MQW-LD fabrication by the liquid phase epitaxy (액상결정성장에 의한 InGaAsP/InP MQW-ND 제작에 관한 연구)

  • 조호성;홍창희;오종환;예병덕;이중기
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.252-257
    • /
    • 1992
  • In this study, InGaAsP/InP MQW-DH wafer was grown by a vertical type LPE system and 10$\mu$m stripe MQW-LD was fabricated with the wafer. The threshold current was about 200 mA and when the cavity length of the LD was 470$\mu$m the central wavelenth of gain spectra was 1.32$\mu$m the lasing wavelength was 1.302$\mu$m which corresponded to the gain center of the quantum well thickness of 300 $\AA$.

  • PDF

Production of Methanol by Resting Cells of Methylosinus trichosporium OB3b (Methylosinus trichosporium OB3b를 이용한 메탄올의 생산)

  • 박성훈;추석열
    • KSBB Journal
    • /
    • v.8 no.4
    • /
    • pp.341-350
    • /
    • 1993
  • As an effort to develop an alternative transportation fuel, the production of methanol from methane gas was studied using the resting cells of an obligatory methanotroph, Methylosinus trichosporium OB3b. The reaction was carried out in high concentration phosphate buffer solutions with the flask-grown cells containing the exclusively cytoplasmic methane monooxygenase (sMMO) activity. The methanol accumulation rate was observed to be 79nmo1/mg·min during the initial 4.5hr. Phosphate-dependent inhibition was found for both sMMO and methanol dehydrogenase (MDH) activities, and the inhibition constants were 185mM and 42mM, respectively. The inhibition mode was noncompetitive. Methanol was found to be very inhibitory to the sMMO activity and the inhibition constant (noncompetitive) was 21mM when propylene was used as substrate. The sMO activity in the resting cells was declined very fast and the rate became very high during the methanol production. These results indicate that the use of M. trichosporium OB3b as a biocatalyst for the methanol production is heavily dependent on the stable maintenance of the whole-cell SMO activity as well as the effective alleviation of product inhibition.

  • PDF

Simulation of Optical Characteristics of 1.3 μm GaAs-Based GaAsSb/InGaAs and GaAsSb/InGaNAs Quantum Well Lasers for Optical Communication (광통신용 GaAs 기반 1.3 μm GaAsSb/InGaAs와 GaAsSb/InGaNAs 양자우물 레이저의 광학적특성 시뮬레이션)

  • Park, Seoung-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Optical gain characteristics of $1.3{\mu}m$ type-II GaAsSb/InGaNAs/GaAs trilayer quantum well structures were studied using multi-band effective mass theory. The results were compared with those of $1.3{\mu}m$ GaAsSb/InGaNAs/GaAs trilayer quantum well structures. In the case of $1.3{\mu}m$ GaAsSb/InGaNAs/GaAs trilayer quantum well structure, the energy difference between the first two subbands in the valence band is smaller than that of $1.3{\mu}m$ GaAsSb/InGaNAs/GaAs trilayer quantum well structure. Also, $1.3{\mu}m$ GaAsSb/InGaNAs/GaAs trilayer quantum well structure shows larger optical gain than $1.3{\mu}m$ GaAsSb/InGaNAs/GaAs trilayer quantum well structure. This means that GaAsSb/InGaNAs/GaAs system is promising as long-wavelength optoelectronic devices for optical communication.

Speciation Analysis of Arsenic Species in Surface Water (수중의 비소 종 분리 분석)

  • Jeong, Gwan-Jo;Kim, Dok-Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.621-627
    • /
    • 2008
  • In this study, a technique of speciation and determination of the trace inorganic arsenic(As(III) and As(V)) in water sample using HPLC-DRC-ICP-MS has been developed. Isocratic mobile phase of 10 mM ammonium nitrate and 10 mM ammonium phosphate monobasic was used and methanol(5 v/v%) was used as flushing solvent. Selection of the best flow rate of reaction gas, O$_2$, and optimization of the parameters such as pH and flow rate of mobile phase, and injection volume of sample for the separation and detection of arsenic species were carried out. The oxygen flow rate of 0.5 mL/min, pH of 9.4 and flow rate of 1.5 mL/min of mobile phase, and injection volume of sample of 100 $\mu$L were found to be the best parameters for the speciation and determination of arsenic species. The analytical features of the method were detection limit 0.10 and 0.08 $\mu$g/L, precision(RSD) 4.3% and 3.6%, and recovery 95.2% and 96.4% for As(III) and As(V), respectively. Analysis time was 4 minutes per sample. Linear calibration graphs with r$^2$ = 0.998 were obtained for both As(III) and As(V). Speciation analysis of arsenic species in the raw water samples collected from the tributary streams to Han River and main stream of Paldnag were performed by the proposed method. The concentrations of As(III) ranged from 0.10 to 0.22 $\mu$g/L and As(V) concentrations ranged from 0.44 to 1.19 $\mu$g/L, and 93.5% of total arsenic was found to be As(V).

Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography (디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건)

  • Lee, Won-Jeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.