• 제목/요약/키워드: Lung perfusion scan

검색결과 71건 처리시간 0.024초

Tc-99m 거대응집알부민을 이용한 폐관류 스캔에서 관찰되는 다발성 열소 (Hot Spots on Tc-99m MAA Perfusion Lung Scan)

  • 임석태;손명희
    • 대한핵의학회지
    • /
    • 제35권4호
    • /
    • pp.288-290
    • /
    • 2001
  • A 61 year-old woman underwent perfusion and inhalation lung scan for the evaluation of pulmonary thromboembolism. Tc-99m MAA perfusion lung scan showed multiple round hot spots in both lung fields. Tc-99m DTPA aerosol inhalation lung scan and chest radiography taken at the same time showed normal findings (Fig. 1, 2). A repeated perfusion lung scan taken 24 hours later demonstrated no abnormalities (Fig. 3). Hot spots on perfusion lung scan can be caused by microsphere clumping due to faulty injection technique or by radioactive embolization from upper extremity thrombophlebitis after injection. Focal hot spots can signify zones of atelectasis, where the hot spots probably represent a failure of hypoxic vasoconstriction. Artifactual hot spots due to microsphere clumping usually appear to be round and in peripheral location, and the lesions due to a loss of hypoxic vasoconstriction usually appear to be hot uptakes having linear $borders^{1-3)}$. Although these artifactual hot spots have been well-known, we rarely encounter them. This report presents a case with artifactual hot spots due to microsphere clumping on Tc-99m MAA perfusion lung scan.

  • PDF

폐절제술후의 폐기능 예측에 대한 나선식 정량적 CT의 유용성 (나선식 정량적 CT와 폐관류스캔과의 비교) (Use of Quantitative CT to Predict Postoperative Lung Function (Comparison of Quantitative CT and Perfusion Lung Scan))

  • 이조한
    • Journal of Chest Surgery
    • /
    • 제33권10호
    • /
    • pp.798-805
    • /
    • 2000
  • Background : the prediction on changes in the lung function after lung surgery would be an important indicator in terms of the operability and postoperative complications. In order to predict the postoperative FEV1 - the commonly used method for measuring changes in lung function- a comparison between the quantitative CT and the perfusion lung scan was made and proved its usefulness. Material and Method : The subjects included 22 patients who received perfusion lung scan and quantitative CT preoperatively and with whom the follow-up of PFT were possibles out of the pool of patients who underwent right lobectomy or right pneumonectomy between June of 1997 and December of 1999. The FEV1 and FVC were calibrated by performing the PFT on each patient and then the predicted FEV1 and FVC were calculated after performing perfusion lung scan and quantitative CT postoperatively. The FEV1 and FVC were calibrated by performing the PFT after 1 week and after 3 momths following the surgery. Results : There was a significant mutual scan and the actual postoperative FEV1 and FVC at 1 week and 3 months. The predicted FEV1 and FVC(pneumonectomy group : r=0.962 and r=0.938 lobectomy group ; r=0.921 and r=913) using quantitative CT at 1 week postoperatively showed a higher mutual relationship than that predicted by perfusion lung scan(pneumonectomy group : r=0.927 and r=0.890 lobectomy group : r=0.910 and r=0.905) The result was likewise at 3 months postoperatively(CT -pneumonectomy group : r=0.799 and r=0.882 lobectomy group : r=0.934 and r=0.932) Conclusion ; In comparison to perfusion lung scan quantitative CT is more accurate in predicting lung function postoperatively and is cost-effective as well. Therefore it can be concluded that the quantitative CT is an effective method of replacing the perfusion lung scan in predicting lung function post-operatively. However it is noted that further comparative analysis using more data and follow-up studies of the patients is required.

  • PDF

기관지 이물 환자에서 폐장관류주사(pulmonary perfusion scan)의 적용 의의 (Diagnostic Value of Pulmonary Perfusion Scan in Patients of Airway Foreign Body)

  • 최종욱;정광윤;민헌기;황찬승;김혜정
    • 대한기관식도과학회지
    • /
    • 제1권1호
    • /
    • pp.75-81
    • /
    • 1995
  • To evaluate the diagnostic value of pulmonary perfusion scan, we obtained 99mTc MAA per-fusion lung scan from 25 cases of airway foreign bodies. The results were as follows. 1) Significant changes in blood gases were not observed after the establishment of regional hypoperfusion caused by airway foreign body. 2) Near total or total defect was noted on perfusion scan from most of the airway foreign body. 3) There was correspondance of findings of perfusion lung scan and duration of airway foreign body. 4) After the removal of airway foreign bodies, perfusion scan abnormalities were reversed in parallel with the recovery of pulmonary blood flow. We concluded that pulmonary perfusion scan may be valuable for detection of foreign body and reversible hypoperfusion.

  • PDF

전폐절제술시 폐관류스캔을 이용한 폐기능의 예측에 대한 평가 (Evaluation of the Predictive Pulmonary Function after Pneumonectomy Using Perfusion Lung Scan)

  • 김길동;정경영
    • Journal of Chest Surgery
    • /
    • 제28권4호
    • /
    • pp.371-375
    • /
    • 1995
  • Surgical resection of lung cancer or other disease is recently required in patients with severely impaired lung function resulting from chronic obstructive pulmonary disease or disease extension. So prediction of pulmonary function after lung resection is very important in thoracic surgeon. We studied the accuracy of the prediction of postoperative pulmonary function using perfusion lung scan with 99m technetium macroaggregated albumin in 22 patients who received the pneumonectomy. The linear regression line derived from correlation between predicting[X and postoperative measured[Y values of FEV1 and FVC in patients are as follows: 1 Y[ml =0.713X + 381 in FEV1 [r=0.719 ,[P<0.01 2 Y[ml =0.645X + 556 in FVC [r=0.675 ,[P<0.01 In conclusion,the perfusion lung scan is noninvasive and very accurate for predicting postpneumonectomy pulmonary function.

  • PDF

정량적 폐관류스캔에 의한 악성폐종양 환자에서의 수술전 평가에 관한 고찰 (Preoperative evaluation of quantitative perfusion lung scintigraphy in the patient with lung cancer)

  • 김원곤;서경필
    • Journal of Chest Surgery
    • /
    • 제17권1호
    • /
    • pp.94-100
    • /
    • 1984
  • The purpose of present study is to investigate the significance of preoperative evaluation with perfusion lung scintigraphy in patients with lung cancer. Lung scans with the use of macroaggregated human serum albumin labeled with technetlum-99m were carried out in 35 patients with lung cancer before thoracotomy at Seoul National University Hospital during the period from November 1981 to September 1983. The relationship between size of the perfusion defect as seen by perfusion lung scan and size of the mass lesion as seen radiologically was correlated with the presence of regional adenopathy and resectability. Among patients with a larger perfusion defect than mass lesion on chest X-ray film.86% were found to have regional lymph node involvement with 29% resectability, whereas among patients in whom a larger defect was not present only 14% had such extension of the disease with 93% resectability. The relative pulmonary arterial perfusion of affected lung was calculated from the counts of radioactivity recorded from affected lung on both anterior and posterior scans expressed as a percentage of the total counts in the scan. The mean relative pulmonary arterial perfusion of the inoperable group [34\ulcorner%] is significantly different from both that of the pneumonectomy group [39\ulcorner%] and that of the lobectomy group [48\ulcorner%].(p<0.01)

  • PDF

개에서 시행한 한쪽 이식 폐의 $^{99m}TC-MAA$ 관류스캔 ($^{99m}TC-MAA$ Pulmonary Perfusion Scan in the Canine Single Luhg Transplant)

  • 전석길;류종걸;박창권;유영선;정덕수;이종길
    • 대한핵의학회지
    • /
    • 제31권3호
    • /
    • pp.365-371
    • /
    • 1997
  • The aim of this study is to evaluate the efficiency of the pulmonary perfusion scan(Pp scan) in the experimental animal single lung transplantation. Eight left lung transplanted mongrel dogs were included in this study. The serial Pp scan with 111MBq $^{99m}TC-MAA$ were done at the periods of immediate postoperative period, POD 3 days, and POD 10-14 days and finally autopsy was done in each cases. The transplanted lung perfusion was analysed as a percentage radioactivity of trans planted/native lung(T/N) ratio. The Pp scan of a donor mongrel dog was used as a reference(left/right lung (T/N) ratio 85.2%). The average T/N ratio of all cases on immediate postoperative state(reperfusion injury) : 19.2%, three acute rejections. 12.6%, three bronchial dehiscences 6.1% and two pulmonary thromboses : 2.0%. Two cases showed moderate improvement of reperfusion injury as increasing the T/N ratio in POD 3 days Pp scan. The T/N ratio showed sequentially decreased in six cases. As a conclusion, the Pp scan could be a non-invasive method in the evaluation of the experimental one-lung transplanted mongrel dog.

  • PDF

관상동맥질환에서 디피리다몰 부하 $^{99m}Tc-MIBI$ 심근스캔의 폐/심장 섭취율 (Lung/Heart Uptake Ratio in Dipyridamole $^{99m}Tc-MIBI$ Myocardial Perfusion Scan in Coronary Artery Disease)

  • 강건욱;이동수;최창운;이경한;정준기;이명철;서정돈;고창순
    • 대한핵의학회지
    • /
    • 제27권2호
    • /
    • pp.218-222
    • /
    • 1993
  • Lung/heart uptake ratio (L/H R) in $^{201}Tl$ myocardial perfusion scan is a reliable marker for long-term prognosis in patients with coronary artery disease. However, the value of L/H R in $^{99m}Tc-MIBI$ myocardial perfusion scan is controversial in determining the prognosis and severity of the coronary artery disease. The purpose of this study was to determine the clinical implications of L/H R in $^{99m}Tc-MIBI$ myocardial perfusion scan. Forty five patients who received $^{99m}Tc-MIBI$ myocardial perfusion scan were divided into control group and coronary artery disease (CAD) group by their clinical findings, EKGs, and $^{99m}Tc-MIBI$ myocardial perfusion scans. Twenty five patients in CAD group were divided into ischemic group and infarct group according to their results from $^{99m}Tc-MIBI$ myocardial perfusion scan. L/H R was calculated on the anterior planar view, 60 minutes after infusion of dipyridamole. Two regions of interest (ROI) were placed on the left lung area 8 pixel above the left ventricle and on the myocardial area which had the highest radioactivity. In the control group, there were no significant differences of L/H R according to sex and age. No significant difference of L/H R was found between the control and CAD group ($0.26{\pm}0.06,\;0.29{\pm}0.05$, p>0.05). In the CAD group, there was also no significant difference of L/H R between the ischemic group and infarct group ($0.29{\pm}0.07,\;0.30{\pm}0.04$, p>0.05). L/H R in CAD group did not show correlations with the defect area of stress polar map (r=0.18, p >0.05) and with the sum of severity weighted extent score or reversibility score which represent severity and extent of myocardial perfusion defect area in stress (r=0.18, p>0.05). We conclude that it is difficult to use L/H R as a marker for severity of CAD in dipyridamole $^{99m}Tc-MIBI$ myocardial perfusion scan.

  • PDF

황견에서 좌측 폐이식수술 -1례 보고- (A Single Left Lung Transplantation in Dog -One Case Report-)

  • 이두연
    • Journal of Chest Surgery
    • /
    • 제27권3호
    • /
    • pp.238-240
    • /
    • 1994
  • We performed post-operative hemodynamic evaluation and lung perfusion scan after left lung transplantation in dog. The heart & lungs were extracted from donor dog while the both lungs were flushed with 4oC Euro-Collin`s solution after heparinization & infusion of prostaglandin E1.In the recipient dog, anastomosis of the left atrial cuff was performed by continuous 4-0 Prolene everted suture, and bronchial anastomosis by telescope method with 4-0 Prolene continuous suture. The end-to-end anastomosis of left main pulmonary arteries was performed with continuous 6-0 Prolene suture. After closure of left thoracotomy incision, the lung perfusion scan was performed post operative 2 days for evaluation of the function of the transplanted lung which showed good perfusion. The dog was sacrificed in the post-operative 5 days for autopsy.

  • PDF

수술후 폐기능 변화의 예측에 대한 연무 흡입스캔과 관류스캔의 비교 (Comparison of Inhalation Scan and Perfusion Scan for the Prediction of Postoperative Pulmonary Function)

  • 천영국;곽영임;윤종길;조재일;심영목;임상무;홍성운;이춘택
    • Tuberculosis and Respiratory Diseases
    • /
    • 제41권2호
    • /
    • pp.111-119
    • /
    • 1994
  • 배경 및 목적: 폐암 환자의 다수가 흡연력이 있고 만성 폐쇄성 폐질환이 병발되어 있으므로 수술후 폐기능의 변화를 정확히 예측하는 것은 수술후 합병증을 예방하는데 중요하다. 폐 절제술 후 잔여 폐기능을 예측함에 있어 현재까지 99mTc-MAA를 이용한 폐관류 스캔이 많이 이용되어 왔지만 이론적으로 폐환기와 폐관류의 불일치가 있는 경우 오차가 있을 수 있어 $^{99m}Tc$-DTPA 연무흡입 환기 스캔을 이용해 잔류 폐기능을 예측하여 관류 스캔을 비교하여 보았다. 방법: 수술전 연무 흡입스캔과 관류 스캔을 시행하고 수술전에 폐기능을 실시하여 잔여 폐기능을 예측하고 수술후 2개월 뒤에 폐기능을 실시하여 상관관계를 비교하여 보았다. 전 폐절제술인 경우: 수술전 폐기능$\times$전체 폐에 대한 잔류폐의 비 폐엽 절제술인 경우: 수술전 폐기능$\times$(1-침범된 폐의 전체폐에 대한 비$\times$절제될 폐의 분절 수/침범된 폐의 총 분절 수) 결과: 1) $FEV_1$에서 연무 흡입스캔을 이용하여 예측한 값과 실측치 간의 상관 계수는 0.94(p<0.0001), 폐관류 스캔을 이용한 경우는 0.86(p<0.0001)이었으며 두 군간에 통계학적으로 유의한 차이는 없었다. 2) FVC에 흡입스캔을 이용한 경우 상관 계수가 0.91(p<0.0001)이었고 폐관류 스캔에서는 0.72(p=0.0005)로 연무 흡입스캔으로 예측한 군에서 상관 관계가 좋았다. 3) $FEF_{25-75%}$에서의 결과는 연무 흡입스캔을 이용한 경우 상관 계수가 0.87(p=0.0001), 폐관류 스캔에서는 상관 계수가 0.87(p<0.0001)로 두 군간에 유의한 차이는 없었다. 4) 두 스캔을 동시에 시행한 군에서 비교한 결과를 보면 연무 흡입 스캔에서 상관 계수는 $FEV_1$ 0.97(p<0.0001), FVC 0.95(p<0.0001), $FEF_{25-75%}$ 0.85(p<0.001)이었고 폐관류 스캔에서는 $FEV_1$ 0.97(p<0.0001), FVC 0.96(p<0.0001), $FEF_{25-75%}$ 0.83(p<0.002)로 두 군간에 유의한 차이는 없었다. 결론: 수술후 잔여 폐기능을 예측함에 있어 연무 흡입스캔 및 관류 스캔사이에 큰 차이가 없었으며 비교적 정확했고 폐기능중에서는 $FEV_1$이 가장 상관 관계가 좋았다.

  • PDF

일측 폐이식 실험견에서 이식폐의 기능 평가연구 (An Assessment of Allograft Function in Canine Single Lung Transplantation)

  • 박창권
    • Journal of Chest Surgery
    • /
    • 제28권12호
    • /
    • pp.1096-1106
    • /
    • 1995
  • We experienced 7 cases of left single lung transplantation in 14 mongrel dogs and analyzed graft lung function by hemodynamics, blood gas analysis, chest X-ray, biopsy and perfusion lung scan. We performed right pulmonary artery cuff[PA cuff for analysis of graft lung function in 3 cases. The donor lungs were flushed with modified Euro-Collins solution[n=3 or low potassium dextran glucose solution[n=4 and preserved for 4 to 5 hours[n=4 or 24 hours[n=3 at 10o C and implanted to the dogs with similar weight . Assessment of left graft lung was done by occluding the right pulmonary artery for 10 minutes using PA cuff. Assessment for graft lung function was done immediately after an operation and after 3 days, 7days and 3 weeks postoperatively. Four dogs survived for 3days, 7days[2 cases and 3 weeks respectively. Other three dogs expired within 3 hours of reperfusion. Immediate perfusion scans of left lung in four survived dogs after reperfusion were 42.1%, 36% , 11% and 5.9% respectively, and another dog with 4.8% perfusion to left lung was dead due to left atrial thrombi after 3 hours reperfusion. In one case among three acute rejections follow-up perfusion scan was done on 3rd and 11th postoperative day and the result decreased from 36% perfusion immediate postoperatively to 21% and 15% respectively. Three expired dogs postoperatively couldn`t tolerate occlusion of right pulmonary artery with above 40 mmHg of mean pulmonary artery pressure. On the other hand, three survival dogs postoperatively tolerated occlusion of right pulmonay artery with less than 30 mmHg of mean pulmonary artery pressure. and one dog couldn`t tolerate same procedure immediate postopertively but in 2 hours reperfusion later tolerated with 29 mmHg of mean pulmonary artery pressure.In conclusion we couldn`t compare the effect of two flushing solutions but low potassium dextran glucose solution showed relatively safe preservation effect in cases with preservation of more than 20 hours. Also canine left single lung transplantation model with PA cuff indicated useful method for the assessment of graft lung function with effect of lung preservation.

  • PDF