• Title/Summary/Keyword: Lung development

Search Result 772, Processing Time 0.028 seconds

Development of Respiratory Motion Reduction Device System (RMRDs) for Radiotherapy in Moving Tumor: Construction of RMRDs and Patient Setup Verification Program

  • Lee, Suk;Chu, Sung-Sil;Lee, Sei-Byung;Jino Bak;Cho, Kwang-Hwan;Kwon, Soo-Il;Jinsil Seong;Lee, Chang-Geol;Suh, Chang-Ok
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.86-89
    • /
    • 2002
  • The purpose is to develop a system to reduce the organ movement from the respiration during the 3DCRT or IMRT. This research reports the experience of utilizing personally developed system for mobile tumors. The patients clinical database was structured for 10 mobile tumors and patient setup error measurement and immobilization device effects were investigated. The RMRD system is composed of the respiratory motion reduction device utilized in prone position and abdominal strip device(ASD) utilized in the supine position, and the analysis program, which enables the analysis on patients setup reproducibility. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the normal tissue volume, field margins and dose volume histogram(DVH) using fluoroscopy and CT images. And, reproducibility of patients setup verify by utilization of digital images. When patients breathed freely, average movement of diaphragm was 1.2 cm in prone position in contrast to 1.6 cm in supine position. In prone position, difference in diaphragm movement with and without RMRDs was 0.5 cm and 1.2 cm, respectively, showing that PTV margins could be reduced to as much as 0.7 cm. With RMRDs, volume of the irradiated normal tissue (lung, liver) reduced up to 20 % in DVH analysis. Also by obtaining the digital image, reproducibility of patients setup verify by visualization using the real-time image acquisition, leading to practical utilization of our software. Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

Projection of Cancer Incident Cases for India - Till 2026

  • Dsouza, Neevan D.R.;Murthy, N.S.;Aras, R.Y.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.7
    • /
    • pp.4379-4386
    • /
    • 2013
  • Projection of cancer incidence is essential for planning cancer control actions, health care and allocation of resources. Here we project the cancer burden at the National and State level to understand the magnitude of cancer problem for the various calendar years from 2011 to 2026 at 5-yearly intervals. The age, sex and site-wise cancer incidence data along with populations covered by the registries were obtained from the report of National Cancer Registry Programme published by Indian Council of Medical Research for the period 2001-2004. Pooled age sex specific cancer incidence rates were obtained by taking weighted averages of these seventeen registries with respective registry populations as weights. The pooled incidence rates were assumed to represent the country's incidence rates. Populations of the country according to age and sex exposed to the risk of development of cancer in different calendar years were obtained from the report of Registrar General of India providing population projections for the country for the years from 2001 to 2026. Population forecasts were combined with the pooled incidence rates to estimate the projected number of cancer cases by age, sex and site of cancer at various 5-yearly periods Viz. 2011, 2016, 2021 and 2026. The projections were carried out for the various leading sites as well as for 'all sites' of cancer. In India, in 2011, nearly 1,193,000 new cancer cases were estimated; a higher load among females (603,500) than males (589,800) was noted. It is estimated that the total number of new cases in males will increased from 0.589 million in 2011 to 0.934 million by the year 2026. In females the new cases of cancer increased from 0.603 to 0.935 million. Three top most occurring cancers namely those of tobacco related cancers in both sexes, breast and cervical cancers in women account for over 50 to 60 percent of all cancers. When adjustments for increasing tobacco habits and increasing trends in many cancers are made, the estimates may further increase. The leading sites of cancers in males are lung, oesophagus, larynx, mouth, tongue and in females breast and cervix uteri. The main factors contributing to high burden of cancer over the years are increase in the population size as well as increase in proportion of elderly population, urbanization, and globalization. The cancer incidence results show an urgent need for strengthening and augmenting the existing diagnostic/treatment facilities, which are inadequate even to tackle the present load.

Evaluation of the Secondary Particle Effect in Inhomogeneous Media for Proton Therapy Using Geant4 Based MC Simulation (Geant4 몬테칼로 시뮬레이션을 활용한 불균질 매질에서의 양성자의 이차입자 영향 분석)

  • Park, So-Hyun;Jung, Won-Gyun;Rah, Jeong-Eun;Park, Sung-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.311-322
    • /
    • 2010
  • In proton therapy, the analysis of secondary particles is important due to delivered dose outside the target volume and thus increased potential risk for the development of secondary cancer. The purpose of this study is to analyze the influence of secondary particles from proton beams on fluence and energy deposition in the presence of inhomogeneous material by using Geant4 simulation toolkit. The inhomogeneity was modeled with the condition that the adipose tissue, bone and lung equivalent slab with thickness of 2 cm were inserted at 30% (Plateau region) and 80% (Bragg peak region) dose points of maximum dose in Bragg curve. The energy of proton was varied with 100, 130, 160 and 190 MeV for energy dependency. The results for secondary particles were presented for the fluence and deposited energy of secondary particles at inhomogeneous condition. Our study demonstrates that the fluence of secondary particles is neither influenced insertion of inhomogeneties nor the energy of initial proton, while there is a little effect by material density. The deposited energy of secondary particles has a difference in the position placed inhomogeneous materials. In the Plateau region, deposited energy of secondary particles mostly depends on the density of inserted materials. Deposited energy in the Bragg region, in otherwise, is influenced by both density of inserted material and initial energy of proton beams. Our results suggest a possibility of prediction about the distribution of secondary particles within complex heterogeneity.

Verification of the Correlation between Progression-free Survival and Overall Survival Considering Magnitudes of Survival Post-progression in the Treatment of Four Types of Cancer

  • Liu, Li-Ya;Yu, Hao;Bai, Jian-Ling;Zeng, Ping;Miao, Dan-Dan;Chen, Feng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1001-1006
    • /
    • 2015
  • Background: With development and application of new and effective anti-cancer drugs, the median survival post-progression (SPP) is often prolonged, and the role of the median SPP on surrogacy performance should be considered. To evaluate the impact of the median SPP on the correlation between progression-free survival (PFS) and overall survival (OS), we performed simulations for treatment of four types of cancer, advanced gastric cancer (AGC), metastatic colorectal cancer (MCC), glioblastoma (GBM), and advanced non-small-cell lung cancer (ANSCLC). Materials and Methods: The effects of the median SPP on the statistical properties of OS and the correlation between PFS and OS were assessed. Further, comparisons were made between the surrogacy performance based on real data from meta-analyses and simulation results with similar scenarios. Results: The probability of a significant gain in OS and HR for OS was decreased by an increase of the SPP/OS ratio or by a decrease of observed treatment benefit for PFS. Similarly, for each of the four types of cancer, the correlation between PFS and OS was reduced as the median SPP increased from 2 to 12 months. Except for ANSCLC, for which the median SPP was equal to the true value, the simulated correlation between PFS and OS was consistent with the values derived from meta-analyses for the other three kinds of cancer. Further, for these three types of cancer, when the median SPP was controlled at a designated level (i.e., < 4 months for AGC, < 12 months for MCC, and <6 months for GBM), the correlation between PFS and OS was strong; and the power of OS reached 34.9% at the minimum. Conclusions: PFS is an acceptable surrogate endpoint for OS under the condition of controlling SPPs for AGC, MCC, and GBM at their limit levels; a similar conclusion cannot be made for ANSCLC.

Mapping, Tissue Distribution and Polymorphism of Porcine Retinol Binding Protein Genes (RBP5 and RBP7)

  • Gong, W.H.;Tang, Z.L.;Han, J.L.;Yang, S.L.;Wang, H.;Li, Y.;Li, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.11
    • /
    • pp.1544-1550
    • /
    • 2008
  • The retinoids (vitamin A and its derivatives) play a critical role in vision, growth, reproduction, cell differentiation and embryonic development. Using the IMpRH panel, porcine cellular retinol binding protein genes 5 and 7 (RBP5 and RBP7) were assigned to porcine chromosomes 5 and 6, respectively. The complete coding sequences (CDS) of the RBP5 and RBP7 genes were amplified using the reverse transcriptase polymerase chain reaction (RT-PCR) method, and the deduced amino acid sequences of both genes were compared to human corresponding proteins. The mRNA distributions of the two genes in adult Wuzhishan pig tissues (lung, skeletal muscle, spleen, heart, stomach, large intestine, lymph node, small intestine, liver, brain, kidney and fat) were examined. A total of nine single nucleotide polymorphisms (SNPs) were identified in two genes. Three of these SNPs were analyzed using the polymerase chain reaction-restriction-fragment length polymorphism (PCR-RFLP) method in Laiwu, Wuzhishan, Guizhou, Bama, Tongcheng, Yorkshire and Landrace pig breeds. Association analysis of genotypes of these SNP loci with economic traits was done in our experimental populations. Significant associations of different genotypes of $RBP5-A/G^{63}$, $RBP5-A/G^{517}$ and $RPB5-T/C^{intron1-90}$ loci with traits including maximum carcass length (LM), minimum carcass length (LN), marbling score (MS), back fat thickness at shoulder (SBF), meat color score (MCS) and hematocrit (HCT) were detected. These SNPs may be useful as genetic markers in genetic improvement for porcine production.

Molecular Analysis of Alternative Transcripts of the Equine Cordon-Bleu WH2 Repeat Protein-Like 1 (COBLL1) Gene

  • Park, Jeong-Woong;Jang, Hyun-Jun;Shin, Sangsu;Cho, Hyun-Woo;Choi, Jae-Young;Kim, Nam-Young;Lee, Hak-Kyo;Do, Kyong-Tak;Song, Ki-Duk;Cho, Byung-Wook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.6
    • /
    • pp.870-875
    • /
    • 2015
  • The purpose of this study was to investigate the alternative splicing in equine cordon-bleu WH2 repeat protein-like 1 (COBLL1) gene that was identified in horse muscle and blood leukocytes, and to predict functional consequences of alternative splicing by bioinformatics analysis. In a previous study, RNA-seq analysis predicted the presence of alternative spliced isoforms of equine COBLL1, namely COBLL1a as a long form and COBLL1b as a short form. In this study, we validated two isoforms of COBLL1 transcripts in horse tissues by the real-time polymerase chain reaction, and cloned them for Sanger sequencing. The sequencing results showed that the alternative splicing occurs at exon 9. Prediction of protein structure of these isoforms revealed three putative phosphorylation sites at the amino acid sequences encoded in exon 9, which is deleted in COBLL1b. In expression analysis, it was found that COBLL1b was expressed ubiquitously and equivalently in all the analyzed tissues, whereas COBLL1a showed strong expression in kidney, spinal cord and lung, moderate expression in heart and skeletal muscle, and low expression in thyroid and colon. In muscle, both COBLL1a and COBLL1b expression decreased after exercise. It is assumed that the regulation of COBLL1 expression may be important for regulating glucose level or switching of energy source, possibly through an insulin signaling pathway, in muscle after exercise. Further study is warranted to reveal the functional importance of COBLL1 on athletic performance in race horses.

Development of an Advanced Deformable Phantom to Analyze Dose Differences due to Respiratory Motion

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Koo, Hyun-Jae;Cho, Min-Seok;Ha, Jin-Suk;Yoon, Do-Kun;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • The difference between three-dimensional (3D) and four-dimensional (4D) dose could be affected by factors such as tumor size and motion. To quantitatively analyze the effects of these factors, a phantom that can independently control each factor is required. The purpose of this study is to develop a deformable lung phantom with the above attributes and evaluate the characteristics. A phantom was designed to simulate diaphragm motion with amplitude in the range 1~7 cm and period up to ${\geq}2s$ of regular breathing. To simulate different tumors sizes, custom molds were created using a 3D printer and filled with liquid silicone. The accuracy of the phantom diaphragm motion was assessed by comparing measured motion with predicted motion. Because the phantom diaphragm motion is not identical to the tumor motion, the correlation between the diaphragm and tumor motions was calculated by a curve fitting method to emulate user-intended tumor motion. Tumors of different sizes were located at same position, and tumor set-up positions were evaluated. The accuracy of phantom diaphragm motion was better than 1 mm. The diaphragm-tumor correlation showed that the tumor motion in the superior-inferior direction increased with increasing diaphragm motion. The tumor motion was larger in the $10cm^3$ tumor than in the $90cm^3$ tumor. The range of difference between the tumor set-up positions was 0 to 0.45 cm. This phantom showed independently adjusting factors such as tumor size and motion to facilitate quantitative analysis of the dosimetric impact of respiratory motion according to these factors.

Development of Image Quality Measurement Method of Coronary Angiography Using Image Analysis Program (영상 분석 프로그램을 이용한 관상동맥 혈관 조영상의 화질 측정 방법 고안)

  • Seo, Young-Hyun;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.111-120
    • /
    • 2020
  • Research should be actively conducted for the ability of X-ray equipment and Retrospective image analysis of X-ray equipment used in hospitals. Retrospective image analysis of X-ray machines, CT and MRI of radiology and medical equipment has been actively conducted. However, image quality measurement using angiography equipment of angiography room is mostly measured with phantom, and image quality measurement on image after being taken by actual patient is insufficient and researches on accurate image quality measurement method are remarkable. It is in short supply. Therefore, through this study, the researcher devised a method to measure the image quality of the acquired image after coronary angiography, and to provide a high quality image to the operator. The equipment and programs used were angiographic examination equipment (Axiom Artis Zee Ceiling) and Image J program. Subjects were images automatically saved in PACS program after coronary angiography.For image quality measurement, selected the AP Caudal 30° image that show the LCA vessel well and the LAO 30° image that show the RCA vessel well during the coronary angiography. In order to measure the background and ROI of the selected image by selecting an image, a criterion on how to find and measure a section where the overlap of the shadow, such as blood vessel, liver and lung is minimized, is presented. In conclusion, there is no exact standard for analyzing an image quality measurement method of angiography image. Therefore, in order to provide quality images to the practistioners, not only the technicians of the equipment but also the users who actually use them should become researchers and conduct research on image quality measurement in various ways. Thus, it is expected to provide excellent images to patients.

Pathogenesis and pathogenicity for the porcine circovirus 2 Korean isolates in weaned pigs (국내 분리 porcine circovirus 2의 이유자돈에 대한 병원성 시험연구)

  • Roh, In-Soon;Lee, Kyung-Woo;Kim, Jae-Hoon;Han, Jeong-Hee;Jean, Young-Hwa
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.2
    • /
    • pp.175-185
    • /
    • 2007
  • This study was carried out to investigate the pathogenesis and pathogenicity of the porcine circovirus type 2 (PCV2) Korean isolate from weaned pigs. Twenty four weaned pigs, PCV2, porcine reproductive and respiratory syndrome virus (PRRSV) and porcine parvovirus (PPV) antibodies free, were allocated to 4 groups (n = 6). Six pigs were inoculated intranasally with PCV2 alone, 6 with PCV2 and PRRSV, 6 with the combined PCV2/PRRSV/PPV inoculum, and 6 were remained as a uninoculated negative control. Pigs were killed 3 and 6 weeks after inoculation and tissue samples examined for gross and microscopic lesions and for the presence of PCV2 antigens and nucleic acids. Experimentally inoculated pigs were evaluated for 3 considerations: 1. development of postweaning multisystemic wasting syndrome (PMWS), 2. distribution of viral antigens by immunohistochemistry and polymerase chain reaction (PCR), and 3. cytokine mRNA levels in lymph nodes. Pigs inoculated with PCV2/PRRSV/PPV showed typical clinical signs, gross findings, and histopathologic characteristics of PMWS. In the PCV2/PRRSV/PPV inoculated group, the PCV2 antigen was widely distributed in various parenchymal organs such as brain, spinal cord, tonsil, lymph nodes, lung, heart, liver, kidney, spleen, and peyer's patch. Lymph node mRNA expression of IL-$1{\alpha}$, IL-2R and IL-8 was determined by real-time PCR. The pigs of PCV2/PRRSV and PCV2/PRRSV/PPV inoculation group, the mRNA expression was characterized by a decrease of IL-$1{\alpha}$, IL-2R and IL-8. The decrease of cytokine mRNA represent the state of T cell immuno-suppression in pig, and nicely support the evidence for the impairment of immune system in pigs with PMWS. In conclusion, PCV2 infection and some additional infectious causes such as PRRSV and/or PPV are warranted for the presence of PMWS in weaned pigs in Korea.

A Measurement System for Color Environment-based Human Body Reaction (색채 환경 기반의 인체 반응 정보 측정 시스템)

  • Kim, Ji-Eon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.2
    • /
    • pp.59-65
    • /
    • 2016
  • The result of analyzing the cognitive reaction due to the color environment has been applied to various filed especially in medical field. Moreover, the study about the identification of patient's condition and examination the brain activity by collecting the bio-signal based on the color environment is being actively conducted. Even though, there were a variety of experiments by convention the color environment using a light or LED color, it still has a problem that affects the psychological information. Therefore, our proposed system using a HMD (Head Mounting display) to provide a completed color environment condition. This system uses the BMS(Biomedical System) to collect the biometric information which responds to the specific color condition and the human body response information can be measured by the development the Memory and Attention test on Mobile phone. The collection of Biometric information includes electro cardiogram(ECG), respiration, oxygen saturation (Sp02), Bio-impedance, blood pressure will store in the database. In addition, we can verify the result of the human body reaction in the color environment by Memory and Attention application. By utilizing the reaction of the human body information that is collected thought the proposed system, we can analyze the correlation between the physiological information and the color environment. And we also expect that this system can apply to the medical diagnosis and treatment. For future work, we will expand the system for prediction and treatment of Alzheimer disease by analyzing the visualization data through the proposed system. We will also do evaluation on the effectiveness of the system for using in the rehabilitation program.