• 제목/요약/키워드: Lung Function Tests

검색결과 117건 처리시간 0.029초

한국 암 특이형 삶의 질 측정도구(C-QOL) 개발 및 평가 (Development and Psychometric Evaluation of a Quality of Life Scale for Korean Patients with Cancer(C-QOL))

  • 이은현
    • 대한간호학회지
    • /
    • 제37권3호
    • /
    • pp.324-333
    • /
    • 2007
  • Purpose: The purpose of this study was to develop and evaluate a quality of life scale for Korean patients with cancer (C-QOL). Methods: The C-QOL was developed and validated as follows, item generation, pilot study, and psychometric tests. A total of 337 patients diagnosed with stomach, liver, lung, colon, breast, or cervix cancer were recruited. The patients were asked to complete the preliminary questionnaire comprising the content-validated items, the SF-36, and the ECOG performance status. The obtained data was analyzed using descriptive statistics, factor analysis, multidimensional scaling (MDS), multitrait/multi-item matrix, ANOVA, t-test, and Cronbach's alpha. Results: Preliminarily twenty-six items were generated through content validity and a pilot study. Factor analysis and MDS extracted a total of 21 items with a 5-point Likert-type scale (C-QOL). The C-QOL included five subscales: physical status (6 items), emotional status (6 items), social function (3 items), concern status (2 items), and coping function (4 items). The C-QOL established content validity, construct validity, item convergent and discriminant validity, known-groups validity, reliability, and sensitivity. Conclusion: The Newly developed C-QOL is an easily applicable instrument which established psychometric properties and reflected Korean culture. It is recommended for further study to examine the responsiveness of the C-QOL using a longitudinal research design.

기관내 흡인방법에 따른 호흡기능의 차이 (The Impact of Different Endotracheal Suction Methods on Respiratory Function: Normal Saline with Chest Vibration vs Normal Saline with Expectorant Mixture)

  • 조효임;이영휘;함옥경;임지영
    • 성인간호학회지
    • /
    • 제20권2호
    • /
    • pp.209-218
    • /
    • 2008
  • Purpose: Regarding the respiratory function of patients with an artificial airway, this study compared the effects between normal saline with chest vibration and normal saline with expectorant mixture, administered before endotracheal suction. Methods: The study was conducted in the ICUs of one university hospital located in Incheon. The experimental group I received normal saline with chest vibration administered before endotracheal suction while the experimental group II received normal saline with expectorant mixture administered before endotracheal suction. For respiratory function, $PaO_2$, $PaCO_2$, and $O_2$ saturation were measured by ABGA at 3 minutes after endotracheal suction for both pre-test and post-test. Results: The two groups were not different significantly regarding $PaO_2$ level and $O_2$ saturation after the treatments, while, the experimental group II had lower $PaCO_2$ level than the experimental group I after the treatments (t = 2.075, p = .042). For experimental group II, post-test score of $PaCO_2$ level was significantly lower than that of the pre-test score (t = 1.842, p = .075). Conclusion: The administration of normal saline with expectorant mixture before endotracheal suction reduced $PaCO_2$ level and improved the respiratory function.

  • PDF

초음파 센싱 방식을 이용한 이동형 호흡량 측정 진단기의 설계 및 구현 (Design and Implementation of Mobile ]Respiration Detection Diagnostic System using Ultrasound Sensing Method fficient Multicasting Environment)

  • 김동학;김영길
    • 한국정보통신학회논문지
    • /
    • 제8권2호
    • /
    • pp.509-515
    • /
    • 2004
  • 폐 기능 검사는 임상에서 환자의 진단 및 치료 판단에 널리 이용되고 있을 뿐 아니라 폐의 연구, 특히 폐의 생리학 및 폐질환의 역학 연구에 일찍부터 사용되어 왔다. 여러 가지 폐 기능 검사 중 가장 쉽고 경제적으로 시행할 수 있는 기본적인 검사법으로 폐활량 검사법(Spirometer)이 있다. 폐활량 검사기는 호흡 기체의 용적 유량의 순간적인 변화량을 측정하는 의학 기기이다. 과거에는 기계식 폐활량기가 주로 사용되었으며, 현재까지도 많이 사용되는 방법은 유체 흐름의 "양" 변화를 유체의 압력 변화로 전환시키는 차압식 방식이다. 그러나 이러한 형태는 압력 손실과 유지 보수가 힘들고, 특성 검사 주기가 짧은 단점을 가지고 있다. 본 논문에서 구현하고자 하는 것은 관성의 오차 및 압력의 오차에 영향을 거의 받지 않는, 그리고 반영구적으로 사용이 가능한 초음파 센싱 방식을 이용한 임베디드 환경의 호흡 량 측정기의 개발을 최종 목표로 하여, 호흡 기체 특성에 적합한 센서, 신호 측정 구현 회로를 포함한 유량 측정 단말부 개발과 측정신호를 이용한 호흡 측정 알고리즘과 진단 알고리즘 구현에 중점을 두었다.

폐기능검사 해석에 정상하한치 변화와 새 해석흐름도가 미치는 영향 (Effect of the Changing the Lower Limits of Normal and the Interpretative Strategies for Lung Function Tests)

  • 나승원;오지선;홍상범;심태선;임채만;고윤석;이상도;김우성;김동순;김원동;오연목
    • Tuberculosis and Respiratory Diseases
    • /
    • 제61권2호
    • /
    • pp.129-136
    • /
    • 2006
  • 연구 배경: 폐기능검사를 해석하는데 정상하한치(lower limits of normal) 선정과 해석흐름도 합의가 필수적이다. COPD 국제지침은 $FEV_1$/FVC 정상하한치로 0.7을 사용하여 폐쇄성장애를 진단한다. 한편, 미국흉부학회(ATS)와 유럽호흡기학회(ERS) 공동으로 새 해석흐름도를 제시하였다. '$FEV_1$/FVC 정상하한치 0.7' 의 정확성과 새 해석흐름도가 실제 폐기능검사 해석에 어떤 영향을 미치는지 알아 보고자 하였다. 방 법: 서울 아산병원의 호흡기검사실에서 2005년 7월 1일부터 11월 30일까지 5개월간 폐활량측정법을 시행한 7362명을 대상으로 하여 '$FEV_1$/FVC 정상하한치 0.7' 의 정확성을 평가하였고 새로운 ATS/ERS 해석흐름도에 따르면 폐용적검사가 추가로 필요한 경우가 얼마나 증가하는지 평가하였다. 상기 기간 내에 같은 날 폐용적검사를 시행한 1611 명을 대상으로 과거 해석흐름도와 비교하여 새로운 ATS/ERS 해석흐름도를 적용하게 되면 폐쇄성장애로 진단되는 경우가 얼마나 증가하는지 알아보았다. 결 과: 1) '$FEV_1$/FVC < 0.7' 에 의한 폐쇄성장애 진단은 연령이 증가할수록 민감도는 증가하였으나 특이도는 감소하였고 양성예측도는 감소하였으나 음성예측도는 증가하였다. 2) 새 ATS/ERS 해석흐름도를 적용할 경우 34.5% (2540명/7362명)의 환자가 추가로 폐용적검사가 필요하였다. 3) 새 ATS/ERS 해석흐름도를 적용할 경우, 과거에 제한성질환으로 진단되었던 환자 중 30%(205명/681명)가 폐쇄성질환으로 진단되었고 이는 전체 환자의 13%(205명/1611명)에 해당하였다. 결 론: 폐쇄성질환 진단기준으로 '$FEV_1$/FVC < 0.7' 을 사용하였을 때 연령에 따라서 민감도와 특이도가 변한다. 또한, 새로운 ATS/ERS 해석흐름도를 실제 환자를 진료하는데 적용하면 폐용적검사를 시행해야 하는 경우가 증가하게 되고 폐쇄성장애로 진단되는 경우가 더 증가하게 된다.

A study on the clinical usefulness, validity, and test-retest reliability of the Spirokit, a device that combines the pulmonary function test and respiratory muscle strength test

  • Kim, Byeong-Soo;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권2호
    • /
    • pp.120-130
    • /
    • 2020
  • Objective: This study was conducted to identify the clinical usefulness, validity, and reliability of the Spirokit, a device that combines the pulmonary function test (PFT) and respiratory muscle strength (RMS) test. Design: Cross-sectional study. Methods: Forty young adults (male: 23, female: 17) participated in a PFT and a RMS test. The concurrent validity for pulmonary function was assessed by comparing data obtained from MicroQuark and the Spirokit and the agreements between the MicroRPM and the Spirokit for RMS were compared. The test-retest reliability of the Spirokit was determined by comparing data obtained from the first and second sessions. The test and retest were performed at the same time after one day for the PFT and RMS test. Validity was estimated using intraclass correlation coefficients (ICCs), and by calculating 95% limits of agreement (LoA). To estimate interrater reliability, ICCs were calculated. Results: The Spirokit showed a high agreement intra class coefficient (ICC [2, 1]): 0.978-0.999, 95% limits of agreements (95% LOA): -0.798 to 0.847 with MicroQuark. It also showed a high level of concordance ICC (2, 1): 0.992 to 0.993, 95% LOA: -9.313 to 11.169 with MicroRPM. The test-retest reliability of the Spirokit was analyzed using ICC (2, 1), and showed a high level of reliability (ICC [2,1]=0.960 to 0.998). Standard error of measurement % (SEM%) was 0.12% to 3.39%, and minimum detectable change% (MDC%) was 0.02% to 3.79%, indicating high level of reliability. Conclusions: The Spirokit is a device with high validity and reliability that can be used to simultaneously measure PFT and RMS tests.

Effect of air stacking training on pulmonary function, respiratory strength and peak cough flow in persons with cervical spinal cord injury

  • An, Sang-Kyun;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • 제7권4호
    • /
    • pp.147-153
    • /
    • 2018
  • Objective: This study investigated the effects of air stacking training (AST) on pulmonary function, respiratory strength, and peak cough flow (PCF) in persons with cervical spinal cord injury (CSCI). Design: Randomized controlled trial. Methods: A total of 24 persons with CSCI were randomly allocated to the AST group (n=12) or the incentive spirometry training (IST) group (n=12). Patients with CSCI received AST or IST for 15 minutes, with 3 sessions per week for 4 weeks, and all groups performed basic exercises for 15 minutes. In the AST group, after the subject inhaled the maximal amount of air as best as possible, the therapist insufflated additional air into the patient's lung using an oral nasal mask about 2-3 times. In the IST group, patients were allowed to hold for three seconds at the maximum inspiration and then to breathe. The pre and post-tests measured forced vital capacity (FVC), forced expiratory volume one at second (FEV1), maximal expiratory pressure (MEP), maximal inspiratory pressure (MIP) and PCF. Results: Both groups showed significant improvements in FVC, FEV1, MEP, MIP and PCF values after training (p<0.05). The FVC in the post-test and the mean change of FVC, FEV1, MIP were significantly higher in the AST group than the IST group (p<0.05). Conclusions: The findings of this study suggested that AST significantly improved pulmonary function, respiratory strength, and PCF in persons with CSCI. Therefore, AST should be included in respiratory rehabilitation programs to improve coughing ability, pulmonary function and respiratory muscle strength.

Impulse Oscillometry (IOS)를 이용한 무기분진 노출자에서의 기도폐쇄 연구 (The Application of Impulse Oscillometry (IOS) in the Workers Who had been Exposed to Inorganic Dust Induced Early Airway Obstruction)

  • 이정오;이유림;최병순;이홍기
    • Tuberculosis and Respiratory Diseases
    • /
    • 제71권6호
    • /
    • pp.431-437
    • /
    • 2011
  • Background: We tried to examine the small airway diseases which can be found early, in workers exposed to inorganic dusts. This is measured in normal breath by using the impulse oscillometry (IOS). Methods: The Pulmonary function test (forced vital capacit [FVC], forced expiratory volume in one second [$FEV_1$], forced expiratory flow between 25% and 75% of vital capacity [$FEF_{25-75}$]), IOS resistance (Rrs at 5, 10, 15, 20, 25, 35 Hz) and reactance (Xrs at 5, 10, 15, 20, 25, 35 Hz) were measured for 454 workers. The subjects were classified into 173 workers of normal (38.1%) and 281 patients with pneumoconiosis (61.9%). Results: There were significant differences between normal and patients with FVC ($3.82{\pm}0.61$ vs. $3.53{\pm}0.56L$), $FEV_1$ ($2.67{\pm}0.63$ vs. $2.35{\pm}0.48L$), and $FEF_{25-75}$ ($1.88{\pm}0.95$ vs. $1.47{\pm}0.80L/sec$) between groups (p<0.05). And as for IOS, there was no significant difference in resistance (Rrs) (p>0.05), and there were significant differences between normal and patients with reactance (Xrs) 15 Hz ($0.003{\pm}0.05$ vs. $-0.006{\pm}0.04kPa/L/s$), 20 Hz ($0.043{\pm}0.05$ vs. $0.031{\pm}0.04kPa/L/s$), and 35 Hz ($0.141{\pm}0.05$ vs. $0.131{\pm}0.05kPa/L/s$) between groups (p<0.05). Conclusion: We could find out that 15 Hz, 20 Hz, and 35 Hz values of reactance were significantly influenced by pneumoconiosis. When usefulness and reproducibility to carry out the IOS are considered, it is thought that in future work will be required to draw the reference values for normal Korean persons.

Clinical Characteristics of Smoking Asthmatics

  • Ha, Eun Sil;Kim, Hye Ok;Lee, Kyoung Ju;Lee, Eun Joo;Hur, Gyu Young;Jung, Ki Hwan;Lee, Sung Yong;Kim, Je Hyeong;Lee, Sang Yeub;Shin, Chol;Shim, Jae Jeong;Kang, Kyung Ho;Yoo, Se Hwa;In, Kwang Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • 제67권6호
    • /
    • pp.506-511
    • /
    • 2009
  • Background: The smoking prevalence in asthma patients are similar to those in the general population. Asthma and active cigarette smoking can interact to create more severe symptoms, an accelerated decline in lung function and impaired therapeutic responses. Accordingly, asthmatics with a history of smoking were examined to define the clinical characteristics and lung function of smoking asthmatics. Methods: The medical records of 142 asthmatics with a known smoking history were reviewed. The patients were divided into three groups according to their smoking history - current smokers, former smokers and non-smokers. The clinical characteristics, lung function, and annual declines of the forced expiratory volume in one second ($FEV_1$) were compared. Results: Fifty-three of the 142 patients (37%) were current smokers, 24 were former smokers (17%) and 65 were non-smokers (45%). The patients with a hospital admission history during the previous year included 16 current smokers (30%), 4 former smokers (17%) and 7 non-smokers (11%) (p=0.02). The mean $FEV_1$ (% predicted) was 76.8${\pm}$19.8%, 71.6${\pm}$21.1% and 87.9${\pm}$18.7% for current smokers, former smokers and non-smokers, respectively (p< 0.001). The $FEV_1$/forced vital capacity (FVC) (ratio, %) values were 63.6${\pm}$12.6%, 59.3${\pm}$14.9% and 72.1${\pm}$11.8% in current smokers, former smokers and non-smokers, respectively (p<0.001). The corresponding mean values for the individual $FEV_1$ slopes were not significant (p=0.33). Conclusion: Asthmatic smokers demonstrated higher hospital admission rates and lower lung function. These findings suggest that the smoking history is an important predictor of a poor clinical outcome in asthma patients.

폐기종환자에서 고해상도 CT와 폐기능검사와의 상관관계 (Correlation between High-Resolution CT and Pulmonary Function Tests in Patients with Emphysema)

  • 안중현;박정미;고승현;윤종구;권순석;김영균;김관형;문화식;박성학;송정섭
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권3호
    • /
    • pp.367-376
    • /
    • 1996
  • 연구배경 : 폐기종의 실제적 진단은 환자들의 임상적 소견과 함께 주로 폐기능검사와 방사선학적검사등으로 이루어지며, 최근에는 고해상도 CT가 널려 이용되는 추세이다. 따라서 폐기종환자들의 고해상도 CT상 나타나는 질환의 심한 정도가 환자의 폐기능검사나 동맥혈가스검사 및 그외의 환자의 임상적 특성들과 어느 정도나 서로 상관관계를 갖는지 CT의 진단적 가치를 알아보고자 하였다. 방법 : 1994년 10월부터 1995년 10월까지 가톨릭의대부속 성모병원에서 폐기종의 임상적 증상과 증후를 보인 환자들중에 폐기능검사와 고해상도 CT등을 이용하여 폐기종으로 진단한 20예(남자 16명, 여자4명, 평균연령 62.5세)를 대상으로 하였다. 고해상도 CT(Siemens Somatom plus Vd-30)상 폐기종의 심한정도는 본 대학 방사선과 전문의에 의해 Sakai방법으로 점수를 판정하였고, 폐기능검사(Medical Graphics Cooperation 1082 Series Plethysmography)상의 여러 지표들과 환자의 연령, 성별, 선정, 체중, 흡연력, 동맥혈가스분석결과 및 CBC상 지표등과 고해상도 CT상 폐기종점수와의 유의한 상관관계를 측정하였다. 결과 : 1) 고해상도 CT상 폐기종점수는 폐기능검사상의 지표인 1초간 노력성 호기량(FEV1), 노력성 폐활량(FVC), 폐확산능(DLco), 폐포량에 대한 폐확산능(DLco/VA)등과 각각 의미있는 역상관관계(inverse correlation)를 보였다(각각의 상관계수 r=-0.53 p<0.05, r=-0.47 p<0.05, r=-0.68 p<0.05, r=-0.49 p<0.05). 2) 고해상도 CT상 폐기종점수는 총폐활량(TLC) 및 잔기량(RV)등과도 의미있는 상관관계가 있었다(각각의 상관계수 r=0.50 p<0.05, r=0.64 p<0.05). 3) 고해상도 CT상 폐기종점수는 동맥혈가스분석검사상 동맥혈산소분압(PaO2)과 의미있는 역상관관계 (r=-0.48 p<0.05)를 보였고 폐포-동맥간 산소분압차{D(A-a)O2}와 의미있는 상관관계(r=0.48 p<0.05)를 보였으나, 동맥혈 이산화탄소분압(PaCO2)과는 서로 상관관계가 없었다(r=-0.32 p>0.05). 4) 고해상도 CT상 폐기종점수는 환자의 연령, 성별, 신장, 체중, 흡연량 및 CBC상 헤모글로빈, 헤마토크리트, 백혈구수등과는 의미있는 상관관계가 없었다. 결론 : 이상의 결과로 폐기종환자에서 고해상도 CT상 폐기종점수는 폐기능검사상의 폐기능장애정도 및 동맥혈가스분석결과와 유의한 상관관계가 있었다.

  • PDF

Bronchiolitis Interstitial Pneumonitis 1예 (A Case of Bronchiolitis Interstitial Pneumonitis)

  • 지수영;유경호;임대훈;신홍준;반희정;오인재;권용수;김규식;임성철;김영철;최유덕;송상윤;선현주
    • Tuberculosis and Respiratory Diseases
    • /
    • 제67권4호
    • /
    • pp.364-368
    • /
    • 2009
  • Bronchiolitis interstitial pneumonitis (BIP), an unclassified and newly described interstitial pneumonia, has a combined feature of prominent bronchiolitis, interstitial inflammation, and fibrosis. It is distinct from bronchiolitis obliterans or bronchiolitis obliterans organizing pneumonia (BOOP). BIP has a better prognosis than common cases of interstitial pneumonia. However, BIP has a poorer prognosis than BOOP. BIP's response to corticosteroids is not as successful as BOOP's response to this treatment. We encountered the case of a 31-year-old woman with BIP with an initial presentation of dyspnea and a cough that had lasted for 3 months. The patient's chest CT scan demonstrated patchy ground glass opacities and multiple ill-defined centrilobular nodules in both lungs, suggesting military tuberculosis or nontuberculous mycobacterial infection. A video-assisted thoracoscopic lung biopsy resulted in the diagnosis of BIP. Clinical symptoms, pulmonary lesions, and pulmonary function tests were improved after oral glucocorticoid therapy.