• Title/Summary/Keyword: Luminance Measurement

Search Result 121, Processing Time 0.026 seconds

Electromagnetic Simulation of Ring-shaped Electrodeless fluorescent Lamps and its Electrical and Optical Characteristics (환형 무전극 형광램프의 전자계 시뮬레이션, 전기적 및 광학적 특성)

  • 최용성;조주웅;이영환;김광수;박대희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.552-559
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficiency replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program(Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250 KHz and some specific conditions. The optical characteristics were measured luminance and a temperature and an optical spectrum distribution for 10 min in a one minute interval at the same time. With a goal of finding alternative materials, we show measurement results of electrical characteristics of a ring-shaped electrodeless fluorescent lamp as a function of frequency and the number of coil turns using a highly permeable($\mu$$_{r}$(equation omitted) 2,000) Mn-Zn ferrite. These results are compared with those of conventional ring-shaped electrodeless fluorescent lamp. It is found that the resistance, inductance and impedance are increased while the quality factor decreases as frequency increases.s.

A Study on Improvement of Lighting Environment of Night-Scape in Anyang-si (안양시 야간경관 조명환경 개선방향에 관한 연구)

  • Park, Joo-Young;Oh, Min-Seok;Kim, Hway-Suh
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.27-35
    • /
    • 2009
  • This study aimed to find problems of nightscape of Anyang-si through examination of behavioral pattern at night and measurement of illumination and luminance in accordance with regional classification following 6 regional classifications on the basis of ur1xm characteristic of Anyang-si. Basic concept of nightscape creation was application of improvement plan with analysis of regional problems and creation of artistic value to enhance image of Anyang-si as a city of art. To obtain balance and unity of night illumination, concept of light zoning was applied to smooth-transform method by regions. Especially, right to view harmonized with surrounding scenery was secured through creating gradual skyline compatible with neighbor buildings using division of each buildings according to their heights. In addition, way to improvement of night lighting environment was proposed as to illumination, height, type of lamp and arrangement of street lights and furniture in accordance with regional characteristics.

Mdlti-View Video Generation from 2 Dimensional Video (2차원 동영상으로부터 다시점 동영상 생성 기법)

  • Baek, Yun-Ki;Choi, Mi-Nam;Park, Se-Whan;Yoo, Ji-Sang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.1C
    • /
    • pp.53-61
    • /
    • 2008
  • In this paper, we propose an algorithm for generation of multi-view video from conventional 2 dimensional video. Color and motion information of an object are used for segmentation and from the segmented objects, multi-view video is generated. Especially, color information is used to extract the boundary of an object that is barely extracted by using motion information. To classify the homogeneous regions with color, luminance and chrominance components are used. A pixel-based motion estimation with a measurement window is also performed to obtain motion information. Then, we combine the results from motion estimation and color segmentation and consequently we obtain a depth information by assigning motion intensity value to each segmented region. Finally, we generate multi-view video by applying rotation transformation method to 2 dimensional input images and the obtained depth information in each object. The experimental results show that the proposed algorithm outperforms comparing with conventional conversion methods.

Development of Wireless Healthcare System for Emergency Treatment (응급상황을 대비한 무선의료관리시스템 개발)

  • Park, Sung-Chul;Moon, Byung-Hyun;Lim, Byung-Hyun;Hwang, Bum-Suk;Choi, Sang-Min
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.125-130
    • /
    • 2009
  • Today, the handicapped or old people require continuous care, but there are a lot of practical difficulties. In this paper, the system measuring health conditions of the handicapped or old people (pulse and temperature) is developed. If urgent health conditions occur, measurement values are delivered to doctors or close family members using SMS (Short Message Service) of cellular phone. In the developed system, Pulse rate is measured by sensing bloodstream using high luminance LED and CdS illumination sensors. Body temperature is also measured by contactless temperature sensor. Also, the measured values are transmitted to a server computer using Zigbee communications. Also, the measured values the average of measurements and the time are saved. The wireless healthcare system is designed to help the emergency for the handicapped and old people by using SMS.

Blue-Light Hazards of 405 nm Sterilization LED Lamps (405 nm 살균용 UV LED 등기구의 청색광 위해에 관한 연구)

  • Hyeon-seok Heo;Chung-hyeok Kim;Ki-ho Nam;Jin-sa Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.3
    • /
    • pp.266-274
    • /
    • 2023
  • Recently, sterilization technology has received increasing interest due to the COVID-19 pandemic and required safety precautions. Particularly, sterilization devices using near ultraviolet (UV) with a 405 nm wavelength are also drawing attention. It has a UV-C wavelength and other sterilization effects. Its blue-colored light on the boundary between UV and visible light is used as a light-emitting diode (LED) lamp for 405 nm sterilization, owing to its longer wavelengths than UV rays. However, the 405 nm wavelength contains blue light that can damage the eyes and skin during prolonged exposures and affect the emotional and biological parts of the body. Currently, 405 nm sterilization LED light registers are circulating in the market. However, they have not undergone safety tests for blue-light hazards. Thus, with the active distribution of sterilization LED lights, solid safety standards and management systems are essential to protect users from blue-light hazards. Accordingly, in this study, we conducted spectral radiance and spectral radiative luminance tests on 405 nm sterilization LED registers available in the market by the measurement criteria of IEC 62471. Safety standards must be established to secure users' safety against blue light hazards at a time when 405nm sterilization LED lights are actively distributed due to COVID-19.

An Experiment and Analysis for Standardize Measurement on CCFL (냉음극 형광램프의 표준화 계측을 위한 실험과 분석)

  • Jin, Dong-Jun;Jeong, Jong-Mun;Jeong, Hee-Suk;Kim, Jin-Shon;Lee, Min-Kyu;Kim, Jung-Hyun;Koo, Je-Huan;Gwon, Gi-Cheong;Kang, June-Gill;Choi, Eun-Ha;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.331-340
    • /
    • 2008
  • A method of measuring the current and voltage is suggested in the circuit of cold cathode fluorescent lamps (CCFLs) which are driven at a high frequency of $50{\sim}100\;kHz$ and a high voltage of several kV. It is difficult to measure the current and voltage in the lamp circuit, because the impedance of the probe at high voltage side causes the leakage current and the variation of luminance. According to the analysis of equivalence circuit with the probe impedance and leakage current, the proper measuring method is to adjust the input DC voltage and to keep the specific luminance when the probe is installed at a high voltage circuit. The lamp current is detected with a current probe or a high frequency current meter at the ground side and the voltage is measured with a high voltage probe at the high voltage side of lamp. The lamp voltage($V_C$) is measured between the ballast capacitor and the lamp electrode, and the output voltage($V_I$) of inverter is measured between inverter output and ballast capacitor. As the phases of lamp voltage($V_C$) and current ($I_G$) are nearly the same values, the real power of lamp is the product of the lamp voltage($V_C$) by the lamp current($I_G$). The measured value of the phase difference between inverter output voltage($V_I$) and lamp current($I_G$) is appreciably deviated from the calculated value at $cos{\theta}=V_C/V_I$.

Real-Time Video Quality Assessment of Video Communication Systems (비디오 통신 시스템의 실시간 비디오 품질 측정 방법)

  • Kim, Byoung-Yong;Lee, Seon-Oh;Jung, Kwang-Su;Sim, Dong-Gyu;Lee, Soo-Youn
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.3
    • /
    • pp.75-88
    • /
    • 2009
  • This paper presents a video quality assessment method based on quality degradation factors of real-time multimedia streaming services. The video quality degradation is caused by video source compression and network states. In this paper, we propose a blocky metric on an image domain to measure quality degradation by video compression. In this paper, the proposed boundary strength index for the blocky metric is defined by ratio of the variation of two pixel values adjacent to $8{\times}8$ block boundary and the average variation at several pixels adjacent to the two boundary pixels. On the other hand, unnatural image movement caused by network performance deterioration such as jitter and delay factors can be observed. In this paper, a temporal-Jerkiness measurement method is proposed by computing statistics of luminance differences between consecutive frames and play-time intervals between frames. The proposed final Perceptual Video Quality Metric (PVQM) is proposed by consolidating both blocking strength and temporal-jerkiness. To evaluate performance of the proposed algorithm, the accuracy of the proposed algorithm is compared with Difference of Mean Opinion Score (DMOS) based on human visual system.

Development of OSL Dosimetry Reader (선량 판독용 OSL 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jung-Il;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.10-15
    • /
    • 2012
  • Design and performance test results of a newly developed optically stimulated luminescence (OSL) measurement system are presented in this paper. Generally, different types of optical filters are used in OSL reader system to minimize the interference of the stimulation light in the OSL signal. For optically stimulation of $Al_2O_3:C$, we have arrived at an optimal combination of the filters, i.e., GG420 filter for filtering the stimulating light source, and a combined UG11 and BG39 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optically stimulation. By using various control boards, the OSL reader device was successfully interfaced with a personal computer. A software was developed to deliver required commands to operate the OSL reader by using the LabView program (National Instruments, Inc.). In order to evaluate the reliability and the reproducibility of newly designed-OSL reader. Performance testing of the OSL reader was carried out for OSL efficiency, OSL decay curve and signal to noise ratio of the standard $Al_2O_3:C$ OSL material. It was found to be comparable with that of commercial Riso reader system.

Threshold Voltage Variation of ZnS:Mn/ZnS:Tb Thin- film Electroluminescent(TFEL) Devices (ZnS:Mn/ZnS:Tb 박막 전계발광소자의 문턱전압 변화)

  • 이순석;윤선진;임성규
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.21-27
    • /
    • 1998
  • Electrical and optical characteristics of ZnS:Mn/ZnS:Tb multilayer TFEL devices were investigated for multi-color electroluminescent display applications. Emission spectra of M $n^{2+}$ and T $b^{3+}$ ions were observed from ZnS:Mn/ZnS:Tb multi-layer TFEL devices, and were very broad from 540 nm to 640 nm. Saturation luminance measured at 155 V was 1025 Cd/$m^2$. C-V, $Q_{t}$ - $V_{p}$ curves showed that the phosphor capacitance ( $C_{p}$ ) and the insulator capacitance ( $C_{i}$ ) were 13.5nF/$\textrm{cm}^2$ and 60 nF/$\textrm{cm}^2$, respectively. Threshold voltage( $V_{thl}$) was shown to decrease from 126 V to 93 V due to the increase of the applied voltage from 155 V to 185 V, which was attributed to the increase of the polarization charge. The equation for the calculation of the threshold voltage as a function of the applied voltage was proposed for the first time. The calculated threshold voltage agreed well with the data obtained from the measurement.t.t.t.

  • PDF

Vision and Aging

  • Kim, In Suk;Hilz, Rudolf
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.9-13
    • /
    • 2002
  • It is well known that the maximum amplitude of accommodation decreases with increasing age.(Presbyopia). With single vision lenses presbyopia can be corrected only for one viewing distance. With progressive power lenses presbyopia can be corrected for all viewing distances. But there are some other changes in the visual system with age which can not be corrected by spectacle lenses. Pupillary diameter decreases and the light transmission of the ocular media decreases. Therefore old people need more light, they need better illumination. Cone density in the retina decreases, this is only one example for changes in the sensory system. These changes in the visual system cause changes in visual functions. At the age of 80 visual acuity has decreased to half. Contrast sensitivity for gratings decreases mainly for high spatial frequencies very important is the increase of stray light in the ocular media and therefore the increase of glare. Veiling luminance increases by a multiple of approximately 4, Dark adaptation gets slower and light sensitivity is approximately 2 log units (factor 100) less when the eye is completely dark adapted. Also colour vision gets worse, especially at low luminances. Elderly people have problems with visual tasks which require divided attention between foveal and peripheral vision. An example is the measurement of the useful field of view. This useful field of view be expanded (improved) by visual training.

  • PDF