• Title/Summary/Keyword: Luminance Analysis

Search Result 195, Processing Time 0.025 seconds

A Study on Analysis of Space Evaluation Using the Luminance Distribution Images (휘도분포영상을 이용한 공간평가분석에 관한 연구)

  • Han, Sang-Pil;Kim, Jong-Youn;Cho, Nam-Cheol;Yi, Yong-Kyu;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.76-81
    • /
    • 2013
  • In our former study, we proposed that the AC-Model might be applied to various conditions. And we also introduced the method for daylighting that it was possible to reduce discomfort glare and to improve visual impressions as the supplementary type and blind-control type on the compound lighting. The purpose of this study was to examine the relationship between physical elements and psychological evaluation of lighting space. The study was made using an full-size space, which were equipped with various luminaries. We investigated the relationship between subjective evaluation and characteristics of light distribution and showed the high correlation between the evaluation rating and luminance distribution over whole room.

Color Constancy Algorithm using the Maximum Luminance Surface (최대휘도표면을 이용한 색 항상성 알고리즘)

  • 안강식;조석제
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.3A
    • /
    • pp.276-283
    • /
    • 2002
  • This paper proposes a new color constancy algorithm using the maximum luminance surface. This method uses a linear model which represents the characteristics of human visual system. The most important process of linear model is the estimation of the spectral distributions of illumination from an input image. To estimate of the spectral distributions of illumination from an input image, we first estimate spectral distribution functions of reflected light on the brightest surface. Then, we estimate surface reflectance functions corresponding to the maximum luminance surface using a principal component analysis of the given munsell chips. We finally estimate the spectral distributions of illumination in an image. Using an estimated illumination, we recover an image by scaling it regularly for the lightness calibration. From the experimental results, the proposed method was effective in recovering the color images compared with others.

Visual Signal Luminance Analysis and Light Source Color Application Study for Escape Guidance in Underground Common Duct (지하공동구 내 탈출 유도를 위한 비주얼 시그널 휘도 분석 및 광색 적용 연구)

  • Jongmin Lim;Hyojoo Kong;Jinsoo Shin;Sangwuk Shin;Seongsik Yoo
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.806-816
    • /
    • 2022
  • Purpose: In this study, the luminance measurement analysis results of the smoke generation state are considered for visual signal display light color for real-time escape guidance in the underground common area. Method: We will analyze the scattering characteristics of light in the atmosphere and optical technology based on the visibility theory, and try to classify the elemental technology as a guidance function through a prototype of a visual signal display device for evacuation guidance. Result: In the experiment conducted under the smoke-generating condition, the results were derived with low luminance ratio and good visibility in the order of red, green, and yellow. However, this result is different from general lighting in which color rendering is considered, and is limited to signals for signals and detection. Conclusion: A conclusions were drawn by reflecting both the luminance measurement results in the smoke generation situation and the preference survey results conducted in previous studies for the light color of the visual signal for signal and detection. When events such as smoke occur, it is better to use the escape guidance visual signal in red or green.

Efficiency and Lifetime Improvement of Organic Light- Emitting Diodes with a Use of Lithium-Carbonate- Incorportated Cathode Structure

  • Mok, Rang-Kyun;Kim, Tae-Wan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.2
    • /
    • pp.60-63
    • /
    • 2012
  • Enhancement of efficiency and luminance of organic light-emitting diodes was investigated by the introduction of a lithium carbonate ($Li_2CO_3$) electron-injection layer. Electron-injection layer is used in organic light-emitting diodes to inject electrons efficiently between a cathode and an organic layer. A device structure of ITO/TPD (40 nm)/$Alq_3$ (60 nm)/$Li_2CO_3$ (x nm)/Al (100 nm) was manufactured by thermal evaporation, where the thickness of $Li_2CO_3$ layer was varied from 0 to 3.3 nm. Current density-luminance-voltage characteristics of the device were measured and analyzed. When the thickness of $Li_2CO_3$ layer is 0.7 nm, the current efficiency and luminance of the device at 8.0 V are improved by a factor of about 18 and 3,000 compared to the ones without the $Li_2CO_3$ layer, respectively. The enhancement of efficiency and luminance of the device with an insertion of $Li_2CO_3$ electron-injection layer is thought to be due to the lowering of an electron barrier height at the interface region between the cathode and the emissive layer. This is judged from an analysis of current density-voltage characteristics with a Fowler-Nordheim tunneling conduction mechanism model. In a study of lifetime of the device that depends on the thickness of $Li_2CO_3$ layer, the optimum thickness of $Li_2CO_3$ layer was obtained to be 1.1 nm. It is thought that an improvement in the lifetime is due to the prevention of moisture and oxygen by $Li_2CO_3$ layer. Thus, from the efficiency and lifetime of the device, we have obtained the optimum thickness of $Li_2CO_3$ layer to be about 1.0 nm.

Research of the Performance Improvement of a Light Shelf Depending on the Diffusion Film Installation Position (확산필름 부착 위치에 따른 광선반 성능개선 연구)

  • Park, Eunsu;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.91-97
    • /
    • 2017
  • Purpose: Various studies on a light shelf are in progress, but it has the problem of glare occurrence. The present study suggested a diffusion film as the method for resolving the glare problem, and aimed to establish light shelf-related basic data by conducting the performance evaluation of a light shelf depending on the installation position of the diffusion film. Method: To carry out the light shelf performance evaluation depending on the diffusion film installation position, three cases were established: no diffusion film installation (Case 1), diffusion film installation on the reflector (Case 2), and diffusion film installation on the upper glass surface of the window for light shelf installation (Case 3); and the energy reduction performance, luminance, and luminance contrast were analyzed based on a testbed. Result: The conclusions of this study are as follows. 1) When the diffusion film was applied, the amount of light introduced through the light shelf decreased, and the average indoor illumination decreased accordingly. 2) For Case 3, the lighting energy reduction performance was identical to the lighting energy reduction efficiency of the existing light shelf; and for Case 2, it was found to be inappropriate as the lighting energy consumption increased compared to that of the existing light shelf. 3) The analysis of the glare for the cases established in this study showed that the luminance contrast was low for Case 3, and thus the glare problem could be minimized. 4) The specific angle of the light shelf could induce the glare problem by increasing the luminance depending on the external condition. 5) Based on the aforementioned contents, the installation position of the diffusion film for improving the lighting performance and glare problem of the light shelf was found to be the upper glass surface of the window for light shelf installation.

Effect of Agricultural Machine Lighting systems on Drivers Night Visibility (농기계의 등화장치가 운전자의 야간시인성에 미치는 영향)

  • Choi, Seung hyun;Lee, Sung yeol;Jang, Taek young;Do, Myung sik
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.4
    • /
    • pp.25-35
    • /
    • 2017
  • This study aimed to analyze a driver's night visibility, according to the installation of a lighting system for driving an agricultural machine during the night time. For the night visibility analysis, a luminance measurement test on the lighting system and a gaze duration measurement test through eye movement measurement devices were carried out. In the luminance measurement test, the increase of luminance was confirmed as relative distance from an agricultural machine was closer and the conditions of the lighting equivalence are improved. Also the gaze duration measurement test, total gaze duration from an agricultural machine increased, as the conditions of the lighting equivalence are improved. In addition, it was identified that the difference in average gaze duration from an agricultural machine was statistically significant as the agricultural machine was driven in high speed. In conclusion, when the lighting system is installed on an agricultural machine, a driver's night visibility from the agricultural machine improves, which is expected to be enormously helpful to the prevention of agricultural machine accidents.

Analysis on the Surface Luminance of Outdoor Lighting by Viewing Distance (경관조명의 시점거리별 표면휘도 특성분식)

  • Choi, Yoon-Seok;Jeong, In-Young;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.18-25
    • /
    • 2006
  • Existing outdoor lighting evaluation methods for the city beautification at night, the measurements are limited by one point to analyze the photometric data. However, this methods could not represent the diversity of photometric result from the distance. This study aims to propose the new outdoor lighting evaluation method of structure surface luminance in accordance with the measuring distance. For the purpose, the field measurement and simulation of an illuminated structure were conducted by CS-100, Digital Photometry Instrument ProMetric 1400, and the Lightscape v 3.2 from the distance of 100[m], 300[m], 500[m]. The result shows that evaluation of the surface luminance by the distance should be measured from about 100[m] of an illuminated object for getting the familiar result from computer simulation.

Study of the Optical System Design of a Reflective LED Stand to Reduce Glare (눈부심 감소를 위한 반사형 LED 스탠드 광학계 설계에 관한 연구)

  • Kong, Mi-Seon;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.334-343
    • /
    • 2020
  • In this paper, a study of the design of a lighting optical system to form indirect light was conducted, to reduce the glare caused by the hot spot of the LED. In the case of using an LED for indoor lighting, glare is caused because of the high luminance and non-uniform luminance distribution. In particular, LED stands are located close to the user's eyes and are used for a long time, so research to reduce glare is essential. Therefore, in this paper an optical system structural study and the design of an LED stand for glare reduction were conducted. Afterward, the luminance analysis and comparison to an existing LED stand product confirmed that the reflective LED stand proposed in this paper had better performance in terms of glare.

A Study of Stability Analysis for Exit Light (유도등의 안정성 해석에 관한 연구)

  • Jung, Jong-Jin;SaKong, Seong-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.81-85
    • /
    • 2008
  • In this study, Standards of Lighting Appliance and Standard of Model Approval and Inspection Technology for EXIT LIGHT are compared so as to analyze stability of a exit light which is fire product. Test items, which are not included in Standard of Model approval and Inspection Technology for EXIT LIGHT, are deduced from aforementioned comparison and analysis. Also the derived test items are experimented with a exit light. For a power factor correction, a power factor correction circuit is designed and power factor, crest factor, asymmetry ratio, luminance variation are analyzed. In order to show the validity of designed circuit, current waveform and voltage waveform are measured.

A adaptively robust method of DCT-based watermarking (DCT 기반 워터마킹의 적응적 강인화 방법)

  • Jun, Young-Min;Kim, Gye-Young;Choi, Hyung-Il
    • The KIPS Transactions:PartB
    • /
    • v.10B no.6
    • /
    • pp.629-638
    • /
    • 2003
  • In this paper, we propose an improved method of watermarking to increase the invisibility of a watermark and robustness against attacks for the purpose of removing the embedded watermark. The proposed method adaptively selects DCT blocks and determines position and intensity for watermarking based on the characteristics of human visual system. The used features are texture, luminance and contrast. We show the experimental results against image processing attacks such as cropping, image enhancement, low pass filtering, and JPEG compression, and then discuss the performance of the proposed method.