• Title/Summary/Keyword: Luminaire

Search Result 122, Processing Time 0.03 seconds

The Development of Average illumination Calculation Software (ZCM에 의한 평균조도 계산용 Software개발)

  • Yun, Mee-Rim;Sim, Sang-Man;Hur, Nam-Don;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.1-9
    • /
    • 2001
  • At the beginning of the lighting design, the improvement of lighting design method and standardization of the lighting design needed for saving lighting energy in the building design that can help to choose a high efficiency luminaire and it can calculate LLF(light loss factor). for that reason Average Illumination Calculation Software using ZCM for lighting designer was developed.

  • PDF

Recognition of pedestrians depending on a luminaire's position over a crosswalk (횡단보도 조명의 위치에 따른 운전자의 보행자 인식 해석)

  • Lee, Chang-Mo;Lee, Min-Uk;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.193-196
    • /
    • 2009
  • 횡단보도 국부 조명은 운전자에게 눈부심을 제공하지 않고 보행자를 직접조명하여 연직면 조도를 높여 보행자를 인식하도록 하여야 한다. 이를 위해서는 횡단보도 국부 조명의 설치 위치가 매우 중요하다. 본 논문에서는 보행자의 보임이 조명기구 위치에 따라 어떻게 달라지는가에 대해 시뮬레이션을 통해 조사하였다. 연구 결과 횡단보도 국부조명을 자동차 진행방향으로 설치하여 보행자를 직접 조명하는 것이 횡단보도내의 어느 위치에 보행자가 있더라도 보행자를 쉽게 볼 수 있게 한다는 것을 알 수 있었다.

  • PDF

A Study on the Optical Characteristics of LED Lamp as Alternative Type of FPL Lamp (FPL형광램프 대체형 LED램프의 조도특성에 관한 연구)

  • Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.1-6
    • /
    • 2015
  • As lamps using LEDs are developed actively, also there have been large request for LED lamps that can replace traditional lamps like fluorescent lamps and metal halide lamps. But so far there are no proper standards that manufacturer can use and test their lamps. As a result of this, manufacturers are not only unable to develop LED lamps but also sell it even though they have technology. In this study, It is proposed that proper test method by investigating compatibility between all-type control gear and LED lamps by analyzing control gear for fluorescent lamp such as magnetic or electronic ballast that is currently used in the market.

Melatonin Suppression under LED Lighting Focused on Spectral Power Distribution Differences

  • Hong, Seong-Kwan;Kim, Kyoung-Sil;Kim, In-Tae;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.7-17
    • /
    • 2015
  • Changes in melatonin concentration levels by differences in CCT of white LED light focused on Spectral Power Distribution (SPD) differences compared to the same CCT of conventional fluorescent light were analyzed. For this, melatonin concentration levels in saliva samples were taken over four different experiments at seven-day intervals. In 71.4% of participants, it was confirmed that melatonin concentration is suppressed by exposure to light, and a slight difference was observed by different CCTs. In addition, Experiment II with a high CCT was relatively high in terms of the melatonin suppression rate compared to Experiment III. A key finding was the possibility that different SPDs under a particular CCT of white LED light compared to the same CCT of conventional fluorescent light could have the same effect on the melatonin suppression.

Uniform Side Illumination Generated from LEDs Arranged by an Annealing Algorithm

  • Wang, Xu;Lei, Panling;Qian, Chaoyi;Wang, Zhiping;Xu, Xuefen;Su, Zhouping
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.332-336
    • /
    • 2022
  • Given a cubic space, it is easy to uniformly illuminate the floor with light sources placed on top. However, little has been reported about uniform illumination on walls with the same configuration of light sources. Here we present a luminaire consisting of nine light-emitting diodes (LEDs) with perfect Lambertian distribution, placed on the top as a 3 × 3 rectangular LED array. The distances between LEDs and tilt angles of each individual LED are adjustable and optimized by an annealing algorithm. After optimization, the array produces a rectangular illumination pattern on one wall with a uniformity of about 89%. Analysis shows that the tilt angles of individual LEDs are key parameters for uniform side illumination. In a scenario that is more practical, the tilt angles of all the LEDs are set to be the same, only decreasing the uniformity to 83%.

Design of a Converter with Anti-blinking Circuitry for T5 LED Indirect Lighting

  • Woo-young, Kim;Quoc Cuong Nguyen;Seong-Kweon Kim
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.103-111
    • /
    • 2024
  • We address the problematic issue of blinking in residential LED lighting systems-a phenomenon that has recently become a significant concern due to voltage sags caused by high-power household appliances. To combat this, we developed a two-stage LED converter with integrated anti-blinking circuitry, specifically designed for T5 LED indirect lighting fixtures. The first stage employs a Power Factor Correction (PFC) boost circuit to enhance voltage stability by aligning the voltage and current phases, thereby minimizing power losses. The second stage, a meticulously engineered DC-DC buck converter, ensures stable lighting despite electrical fluctuations. Rigorous testing has confirmed our converter's efficacy in maintaining consistent light output without blinking, thereby substantially improving user comfort and adhering to strict standards for harmonic distortion and electromagnetic compatibility. Our breakthrough provides a robust solution to a pressing issue, marking a significant advancement in LED lighting technology.

An Efficient Smart Indoor Emotional Lighting Control System based on Android Platform using Biological Signal (생체신호를 이용한 안드로이드 플랫폼 기반의 효율적인 스마트 실내 감성조명 제어 시스템)

  • Yun, Su-Jeong;Hong, Sung-IL;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.199-207
    • /
    • 2016
  • In this paper, we propose efficient smart indoor emotional lighting control system based on android platform using the biological signal. The proposed smart indoor smart emotional lighting control system were configured as the biological signal measurement device and removable smart wall pad, lighting driver, luminaire. The control system was extracts the emotional language by measured the biological signal, and it was transmitted a control signal to each lighting driver using a bluetooth in the wall pad. The lighting driver were designed to control the lighting device through an expansion board by collected control signal and the illuminance information the surrounding. In this case, the wall pad can be selecting of manual control and the bio signal mode by that indoor emotional lighting control algorithms, and it was implemented the control program that possible to partial control by selecting the wanted light. Experiment results of the proposed smart indoor emotional lighting control system, it were possible to the optional control about the luminaire of required area, and the manual control by to adjustable of color temperature with that the efficiently adjustable of lighting by to biological signal and emotional language. Therefore, were possible to effective control for improvement of concentration and business capability of indoor space business conduct by controlling the color and brightness that is appropriate for your situation. And, was reduced power consumption and dimmer voltage, lighting-current than the existing-emotional lighting control system.

Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires (LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo;Han, Won-Tak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.1-7
    • /
    • 2008
  • This study is intended to compare physical properties of fluorescent luminaires with ones of LED luminaires so as to analyze fundamental characteristics of LED luminaires. For this, a comparative analysis of uniformity ratio of illuminance and luminance distribution of these two luminaires was made, and materials for applying LED luminaires to interior construction space were prepared. This study was carried out in four stages. First, a theoretical review on LED illumination light source was made compared with the existing luminaires. Second, a mock-up to control experimental variables to meet the objective of this study was manufactured. Third uniformity ratio of illuminance and luminance distribution of each luminaire were measured by using the mock-up. Fourth, a comparative analysis of uniformity ratio of illuminance and characteristics of luminance distribution of the existing fluorescent luminaires and LED ones was made. As a result of the study, the uniformity ratio of illuminance of LED luminaires, 0.559, was higher than one of the existing fluorescent luminaires, 0.522. Namely, it was shown that illuminance distribution of LED luminaires was uniform and global diffuse was good. As a result of measuring luminance distribution, it was found that luminance distribution of LED luminaires was more uniform than one of the existing fluorescent luminaires. The maximum luminance of fluorescent luminaires and LED luminaires over the wall was $180.6[cd/m^2]$ and $155.26[cd/m^2]$ respectively. Namely, the maximum luminance of fluorescent luminaires was higher than one of LED luminaires. The average luminance of fluorescent luminaires and LED luminaires was $44.32[cd/m^2]$ and $58.65[cd/m^2]$. Like this, the average luminance of LED luminaires was higher than one of fluorescent luminaires. Considering these results, it's thought that LED luminaires can give a person in the room a more comfortable working environment than fluorescent luminaires.

Development of The LED FDL for Replacing Fluorescent Lamp (형광램프대체용 LED FDL 개발)

  • Yang, Byong-Moon;Jang, Woojin;Cha, Jae-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.9-14
    • /
    • 2015
  • Due to the declining LED price and environment-friendly energy policies, CO2 emission reduction and energy-saving, the LED lighting industry is accelerating rapidly. In particular, the needs for LED lamp, replacing the existing fluorescent lamp without exchange luminaire or driver circuits, are also rapidly increasing. Therefore, replacement for T8 fluorescent lamp, LED T8 lamp was developed and standardized. However, except LED T8 lamps, other lamps' regulations or standards were not enacted. Also, the stability of fluorescent lamp substitutable LED lamp is low due to the difference in electrical characteristics and mismatch between the existing fluorescent lamp ballast and LED lamp. Therefore, many are struggling while developing fluorescent lamp substitutable LED lamp. In this paper describes the properties of existing fluorescent lamp ballasts and the considerations while developing fluorescent lamp substitutable LED lamp : demonstrating its validity by experiments the developed fluorescent lamp substitutable LED lamp prototype.

The Economics Evaluation of Lighting System Considering Maintenance Factor (보수율을 고려한 조명시스템의 경제성 평가)

  • Sim, Sang-Man;Kim, Gi-Hoon;Hwang, Nam-keuk;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.1-7
    • /
    • 2001
  • Factors which affect largely the economics of lighting system, are initial installation costs, maintenance costs, energy costs as so on. In these costs, maintenance cost, lamp replacement labor cost, luminaire cleaning cost et al. so the economics of lighting system are evaluated different by maintenance planning. It is important to evaluate which lighting system would be economically advantageous in a initial design. In this study, the importance of maintenance factor is verified by the evaluations of the economics of lighting systems while maintenance factor is varied composition factors in ZCM which is used to calculate the average illuminance.

  • PDF