• Title/Summary/Keyword: Lumbar Compression Fracture

Search Result 67, Processing Time 0.026 seconds

Percutaneous Vertebroplasty in Treatment of Osteoporotic Vertebral Body Fractures : Early Result (골다공증성 추체골절에 대한 경피적 척추성형술 : 초기성적)

  • You, Young Sang;Shin, Jae Hack;Kim, Il-Man
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.163-167
    • /
    • 2001
  • Objective : Percutaneous vertebroplasty has recently been introduced as an interesting therapeutic alternative for the treatment of thoracolumbar vertebral body fractures in elderly persons with osteoporosis. The authors present the early results of this method. Method and Material : From July 1999 to April 2000, percutaneous transpedicular technique was used in 20 patients (2 men and 18 women) whose mean age was 67.5 years old(range 59-79) with painful vertebral compression(22) and burst(2) fractures. The interval between fracture and vertebroplasty ranged 1 day to 4 months. The procedure involved percutaneous puncture of the injured vertebra via transpedicular approach under fluoroscopic guidance, followed by injection of polymethylmetacrylate(PMMA) into the vertebral body through a disposable 11-guage Jamshidi needle. Result : The most common cause of fracture was slip down and the most frequent injured level was the twelfth thoracic spine. The procedure was technically successful bilaterally in 18 patients(9 thoracic and 15 lumbar spines) with an average injection amount of 7.7ml PMMA in each level. Seventeen(94.4%) patients reported significant pain relief immediately after treatment. Two leaks of PMMA were detected with postoperative CT in spinal epidural space and extravertebral soft tissue without clinical symptoms. Conclusion : Although this study represents the early results, percutaneous vertebroplasty seems to be valuable tool in the treatment of painful osteoporotic vertebral body fractures in elderly, providing acute pain relief and early mobilization.

  • PDF

A New Method of Approach for Percutaneous Thoracic Vertebroplasty in Vertebral Compression Fracture -Case report- (흉추 압박골절환자를 위한 경피적 척추성형술의 새로운 접근법 -증례 보고-)

  • Shin, Keun-Man
    • The Korean Journal of Pain
    • /
    • v.13 no.2
    • /
    • pp.237-241
    • /
    • 2000
  • Vertebral compression fractures commonly afflict the elderly. Some patients suffer from severe mechanical pain in spite of treatments with strong analgesics and bracing. Vertebroplasty, which was originally used for vertebral hemangioma, is effective for patients who do not respond to these more conservative treatments. However, the procedure has some risk. Leaks of bone cement into perineural tissues can be a serious complication. In contrast to the lumbar vertebrae, the outer margin of the pedicle of the thoracic vertebrae is almost in line with the outer margin of the body. This, combined with the thinner pedicle of the thoracic vertebrae, makes proper needle placement difficult. The posterolateral approach is preferred to the transpedicular approach in order to avoid the danger of destroying the inner cortex of the pedicle. But there can be a problems with the standard posterolateral approach. The rib can be broken, the pleura can be punctured. A new and safer approach is possible. Before penetrating the bone, the needle is positioned at the upper margin of the transverse process, 5 mm away from the pedicle. To achieve this positioning, the needle must puncture the skin 1~1.5 cm laterally and 3~5 mm cranially to the target point on the bone. This approach was used for 10 patients and we achieved good results with no serious complication.

  • PDF

Radicular Pain due to Subsidence of the Nitinol Shape Memory Loop for Stabilization after Lumbar Decompressive Laminectomy

  • Son, Byung-Chul;Kim, Deog-Ryeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.1
    • /
    • pp.61-64
    • /
    • 2015
  • A number of dynamic stabilization systems have been used to overcome the problems associated with spinal fusion with rigid fixation recently and the demand for an ideal dynamic stabilization system is greater for younger patients with multisegment disc degeneration. Nitinol, a shape memory alloy of nickel and titanium, is flexible at low temperatures and regains its original shape when heated, and the Nitinol shape memory loop (SML) implant has been used as a posterior tension band mostly in decompressive laminectomy cases because the Nitinol implant has various characteristics such as high elasticity and a tensile force, flexibility, and biological compatibility. The reported short-term outcomes of the application of SMLs as posterior column supporters in cervical and lumbar decompressive laminectomies seem to be positive, and complications are minimal except for the rare occurrence of pullout and fracture of the SML. However, there was no report of neurological complications related to neural compression in spite of the use of the loop of SML in the epidural space. The authors report a case of delayed development of radiating pain caused by subsidence of the SML resulting epidural compression.

Percutaneous Polymethylmethacrylate Vertebroplasty in the Treatment of Osteoporotic Thoracic and Lumbar Vertebral Body Compression Fractures : Outcome of 159 Patients (159명의 골다공증성 흉추 및 요추부 골다공증성 추체 압박골절 환자에 대한 경피적 척추성형술 후 치료결과)

  • Lee, Jae-Un;Ryu, Kyeong-Sik;Park, Chun-Kun;Choi, Yeong-Kun;Park, Chun-Kun;Ji, Chul;Cho, Kyung-Suk;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.173-179
    • /
    • 2001
  • Purpose : To assess therapeutic effects of percutaneous polymethylmethacrylate(PMMA) vertebroplasty on the pain caused by osteoporotic thoracic and lumbar vertebral body compression fractures in a large scale of a prospective clinical design, and to determine clinical factors influencing its therapeutic effects. Methods : A prospective clinical study was carried out in 349 vertebral levels of 159 patients between April 1998 and July 1999. The compression fractures were confirmed with bone scan and spine CT, and bone marrow density was measured. Visual analogue scale(VAS) score was used for pre- and post-operative assessments of the pain. All 159 patients were assessed immediately after surgery, and 140 patients of them were followed-up for about 6 months in average. Results : Partial and complete pain relief was sustained immediately after operation in 73%, through follow-up period in 88% of the patients. Pain relief was not proportional to the amount of PMMA or the rate of increase in the height of the compressed vertebral body. It appears that 3 to 6cc of PMMA was proper enough to sustain pain relief. Better clinical improvement was achieved in the patients treated within 6 months after occurrence of vertebral body fracture. The most frequent surgical complication was epidural leakage of PMMA, and the most serious complication was extravertebral leakage into the paravertebral muscles, which appeared to exert the worst influence on the outcome. However, surgery was not required in these patients. Conclusion : Therapeutic effects of PMMA percutaneous vertebroplasty on osteoporotic vertebral body compression fractures were confirmed in a relatively large scale of prospective clinical study. It appears that good outcome can be achieved in patients treated within 6 months after fracture, treated each level with 3 to 6cc of PMMA in amount. without serious complications.

  • PDF

Therapeutic Efficacy of Pulsed Radiofrequency Treatment in Lumbar Radicular Pain (요추부 신경근통 환자에서의 박동성 고주파술의 치료 효과)

  • Kim, Young Ki;Jung, Il;Han, Sang Hee
    • The Korean Journal of Pain
    • /
    • v.21 no.3
    • /
    • pp.202-205
    • /
    • 2008
  • Background: Lumbar radicular pain is a frequent and often debilitating event. Although many treatment methods have been described in several studies, the available evidences regarding efficacy is not sufficient enough to draw definitive conclusions on an optimal therapy regime. Pulsed radiofrequency (RF) treatment was found to exert a beneficial effect on intractable radicular pain in individuals. The purpose of this study was to assess the efficacy of pulsed RF of the dorsal root ganglion for chronic lumbar radicular pain. Methods: Twenty five patients with chronic lumbar radicular pain that was refractory to selective nerve root blockage met the inclusion criteria of our study and received pulsed RF treatment. The average numeric rating scale (NRS) for leg pain during usual activities and the Oswestry disability index (ODI) were measured at 1 and 3 months after the procedure. Results: Of the 25 patients accepted for pulsed RF treatment, one dropped out due to a vertebral compression fracture during this study. ODI and NRS showed a positive trend in favor of the pulsed RF treatment. No significant complications were observed during the study period. Conclusions: It appears that pulsed RF treatment of the lumbar spinal dorsal root ganglion may be an effective treatment method for patients suffering from lumbar radicular pain, and who were not responsive to selective nerve root blockage.

Study on the Movement of New Qi-gong "WuQinXi" Exercise for Lumbar Spinal Disease : Based on 20 Mode, 30 Mode, 40 Mode (요추 질환에 대한 신기공 오금희의 동작연구 - 20식, 30식, 40식을 중심으로 -)

  • You, Kyung Gon;Kwon, Young Dal;Jeong, Hyun Woo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.2
    • /
    • pp.129-136
    • /
    • 2014
  • The "WuQinXi" exercise, one of the medical Qi-gongs, is an exercise maximizing human's self healing power and has been confirmed to be effective significantly at several modern researches. There are many exercise therapies in western medcine, such as Willams's flexion exercise, Mckenzie's extension exercise, vertebral stabilization exercise and so on. However, there isn't a special exercise therapy which can be applied for medical practice in oriental medicine. So we selected 24 motions which are related with lumbar movements from 3 type "WuQinXi" exercises ; 20 mode, 30 mode, and 40 mode. And then, we classified them according to lumbar movements as flexion, extention, lateral bending and rotation, and also functions as stabilization and rubbing. Next, with these classifications, we assorted them by kinds of lumbar spinal disease as HIVD(herniation of intervertebral disc), spinal stenosis, spondylolysis and spondylolisthesis, facet joint syndrome, compression fracture and spondylosis. We expect that "WuQinXi" exercise be a exercise therapy for lumbar spinal disease at an oriental medical clinic in this way. Oriental medical doctors will be able to teach easily patients "WuQinXi" exercise's motions at clinic, depending on kinds of lumbar spinal disease each patient suffers from. We plan to study the effect of "WuQinXi" exercise by comparing patients who do the "WuQinXi" exercise with the patients who do the western medical exercise therapy.

Balloon Kyphoplasty through Extrapedicular Approach in the Treatment of Middle Thoracic Osteoporotic Compression Fracture : T5-T8 Level

  • Kim, Hyeun-Sung;Kim, Seok-Won;Ju, Chang-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.5
    • /
    • pp.363-366
    • /
    • 2007
  • Objective : Kyphoplasty performed in the middle thoracic spine presents technical challenges that differ from those in the lower thoracic or lumbar region due to small pedicle size and angular severity for thoracic kyphosis. The purpose of this study was to evaluate the efficacy of balloon kyphoplasty through extrapedicular approach for the treatment of intractable osteoporotic compression fractures in the middle thoracic spine. Methods : The patients who were performed with one level balloon kyphoplasty through extrapedicular approach due to painful osteoporotic compression fractures at T5-T8 from June 2003 to July 2005 were retrospectively analyzed. Imaging and clinical features were analyzed including involved vertebrae level, vertebral height, Injected cement volume, clinical outcome and complications. Results : Eighteen female patients (age ranged from 60 to 77 years old) were included in this study. The average amount of the implanted cement was $4.2{\pm}1.5\;cc$. The mean cobb angle and compression rate were improved from $12.1{\pm}6.5^{\circ}$ to $8.5{\pm}7.2^{\circ}$ and from 30% to 15%, respectively. The mean pain score (visual analogue scale) prior to kyphoplasty was 7.9 and it decreased to 3.0 after the procedure. Cement leakage to the adjacent disc (2 cases) and paravertebral soft tissues (1 case) were seen but there were no major complications such as pneumothorax, segmental arte 이 Injury, pulmonary embolism, or epidural leakage. Conclusion : Balloon kyphoplasty through extrapedicular approach is considered as a safe and effective in treating the middle thoracic regions with low complication rate.

Repeat Vertebroplasty for the Subsequent Refracture of Procedured Vertebra

  • Choi, Sang Sik;Hur, Won Seok;Lee, Jae Jin;Oh, Seok Kyeong;Lee, Mi Kyoung
    • The Korean Journal of Pain
    • /
    • v.26 no.1
    • /
    • pp.94-97
    • /
    • 2013
  • Vertebroplasty (VP) can effectively treat pain and immobility caused by vertebral compression fracture. Because of complications such as extravasation of bone cement (polymethylmethacrylate, PMMA) and adjacent vertebral fractures, some practitioners prefer to inject a small volume of PMMA. In that case, however, insufficient augmentation or a subsequent refracture of the treated vertebrae can occur. A 65-year-old woman visited our clinic complaining of unrelieved severe low back and bilateral flank pain even after she had undergone VP on the $1^{st}$ and $4^{th}$ (L1 and L4) lumbar vertebrae a month earlier. Radiologic findings showed the refracture of L1. We successfully performed the repeat VP by filling the vertebra with a sufficient volume of PMMA, and no complications occurred. The patient's pain and immobility resolved completely three days after the procedure and she remained symptom-free a month later. In conclusion, VP with small volume cement impaction may fail to relieve fracture-induced symptoms, and the refracture of an augmented vertebral body may occur. In this case, repeat VP can effectively resolve both the persistent symptoms and problems of new onset resulting from refracture of the augmented vertebral body due to insufficient volume of bone cement.

Kyphotic Angle Measurement Accuracy for Vertebral Osteoporotic Compression Fracture; Reliable Method for Kyphotic Angle Measurement

  • Hong, Jae-Taek;Lee, Sang-Won;Son, Byung-Chul;Sung, Jae-Hoon;Park, Choon-Keun;Kim, Moon-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.256-259
    • /
    • 2006
  • Objective : Having a reliable and reproducible measurement technique to measure the sagittal contour in vertebral fractures is paramount to clinical decision making. This study is designed to determine the most reliable measurement technique in osteoporotic vertebral compression fracture. Methods : Fifteen lateral radiographs of thoracic and lumbar fractures were selected and measured on two separate occasions by three spine surgeons using six different measurement techniques [Centroid, Harrison Posterior Tangent Methods and 4 different types of modified Cobb method]. The radiograph quality was assessed and the center beam location was determined. Statistical analysis including ANOVA for repeated measures was carried out using the SAS software [v 8.0]. Results : The inter and intraobserver variance of the Cobb method 4 and Harrison posterior tangent method were significantly lower than the other four methods. The intraobserver correlation coefficients were the most consistent using the Cobb method 4 [0.982]. which was followed by the Harrison posterior tangent [0.953] and Cobb methods 1 [0.874]. The intraobserver agreement [% of repeated measures within 5 degrees of the original measurement] ranged from 42% to 98% for each technique for all three observers, with the Cobb method 4 showing the best agreement [97.8%] followed by the Harrison posterior tangent method [937%]. Conclusion : The Cobb method-4 and Harrison posterior tangent methods, when applied to measuring the kyphosis, are reliable and have a similar small error range. The Cobb method 4 shows the best overall reliability. However, the centroid method and Cobb method using a fractured endplate do not produce an accurate result due to inter and intraobserver differences in determining the baseline.