• Title/Summary/Keyword: Lower leg length

Search Result 139, Processing Time 0.028 seconds

A Study on the Physiological Properties of Skating Players : Skin Temperature and Clothing Temperature in Body Parts

  • Jeon, Hyang-ran
    • Fashion & Textile Research Journal
    • /
    • v.2 no.5
    • /
    • pp.423-429
    • /
    • 2000
  • This study was conducted to find out the relationship between skin temperature and clothing temperature in body parts. Four different kinds of fabrics were used in this experiment. These fabrics were a (Ny/Spun, 81.8/18.2%), b (Wool/Poly/span, 50/45/5%), (Wool/Ny/Span70/25/5) and d (Wool/Poly/Span 45/45/10%). The subjects skated at indoor ice rink where the length was 111.12 m, the temperature was $11{\pm}1^{\circ}C$ and the humidity was $70{\pm}10%$. The four an male professional skaters speed was $17{\pm}1$ seclm/lap. Physiological parameters were skin temperature at 4 body points (chest, upper arm, thigh, leg) and clothing temperature at chest was measured every 15 second. Experiment protocol was as follows: resting before skating (5 min.), skating (5 min.), and resting after skating (10 min.). The results were as follows; The mean skin temperature by fabrics shows b > a > d > c. The mean skin temperature began to decline little by little as soon as the subjects entered the indoor ice rink. After they rested for five minutes, they started skating and the mean skin temperature declined widely. After skating, the mean skin temperature increased step by step. It maintained the similar temperature. The value of skin temperature at body points shows Leg > Chest > Upper arm > Thigh. Because of the characteristics of skating uniforms, the skin temperature of the leg is the highest. The skating uniform was designed to have a protective portion in the leg. The chest produces the highest temperature in the body. The comparison of difference values in skin temperature show Thigh > Upper arm > Chest > Leg. While skating in a cold atmosphere, the largest difference value is clothing temperature. The clothing temperature is lower than the skin temperature during skating. The difference value of clothing temperature is larger than the skin temperature of the chest.

  • PDF

Evaluation of accuracies of genomic predictions for body conformation traits in Korean Holstein

  • Md Azizul Haque;Mohammad Zahangir Alam;Asif Iqbal;Yun Mi Lee;Chang Gwon Dang;Jong Joo Kim
    • Animal Bioscience
    • /
    • v.37 no.4
    • /
    • pp.555-566
    • /
    • 2024
  • Objective: This study aimed to assess the genetic parameters and accuracy of genomic predictions for twenty-four linear body conformation traits and overall conformation scores in Korean Holstein dairy cows. Methods: A dataset of 2,206 Korean Holsteins was collected, and genotyping was performed using the Illumina Bovine 50K single nucleotide polymorphism (SNP) chip. The traits investigated included body traits (stature, height at front end, chest width, body depth, angularity, body condition score, and locomotion), rump traits (rump angle, rump width, and loin strength), feet and leg traits (rear leg set, rear leg rear view, foot angle, heel depth, and bone quality), udder traits (udder depth, udder texture, udder support, fore udder attachment, front teat placement, front teat length, rear udder height, rear udder width, and rear teat placement), and overall conformation score. Accuracy of genomic predictions was assessed using the single-trait animal model genomic best linear unbiased prediction method implemented in the ASReml-SA v4.2 software. Results: Heritability estimates ranged from 0.10 to 0.50 for body traits, 0.21 to 0.35 for rump traits, 0.13 to 0.29 for feet and leg traits, and 0.05 to 0.46 for udder traits. Rump traits exhibited the highest average heritability (0.29), while feet and leg traits had the lowest estimates (0.21). Accuracy of genomic predictions varied among the twenty-four linear body conformation traits, ranging from 0.26 to 0.49. The heritability and prediction accuracy of genomic estimated breeding value (GEBV) for the overall conformation score were 0.45 and 0.46, respectively. The GEBVs for body conformation traits in Korean Holstein cows had low accuracy, falling below the 50% threshold. Conclusion: The limited response to selection for body conformation traits in Korean Holsteins may be attributed to both the low heritability of these traits and the lower accuracy estimates for GEBVs. Further research is needed to enhance the accuracy of GEBVs and improve the selection response for these traits.

A Visual Effect according to Pants Style and Geometric Pattern - Using a 3D Virtual Garment System - (가상착의 시스템을 이용한 팬츠 스타일과 기하학 무늬의 특성에 따른 시각적 효과)

  • Park, Woo Mee
    • Fashion & Textile Research Journal
    • /
    • v.15 no.4
    • /
    • pp.504-513
    • /
    • 2013
  • This study evaluates the difference of visual effect according to pant style and geometric pattern. The researcher made 28 stimuli-combination of four pant Stiles (classic, baggy, skinny, and bell-bottom) and seven geometric pattern (large vertical stripe, small vertical stripe, large horizontal stripe, small horizontal stripe, large check, small check, and hound's tooth check). The test involved 96 female college students. The stimuli were made with the i-Designer computer program. The panels tested the computer screen images of all manikins wearing pants. A 7-point scale was used to evaluate each image. For the data analysis, ANOVA and Duncan-test were applied along with an SPSS program. The results of this study are as follows. Three factors (lower-body compensation, abdomen highlight, and length compensation) influenced the visual effect pant styles and geometric patterns. The skinny style and large vertical stripe evaluated positively in elongated height and leg length and a slimmer overall body. It was shown that the vertical stripe pattern was evaluated as more positive than the horizontal stripe pattern in the visual effect; particularly, the results showed distinct aspects in the classic pants style. The mutual influence of the visual effect (according to pants style and geometric pattern) were indicated as two factors of lower-body compensation and length compensation. A more positive visual effects resulted in a higher mutual influence on pant style and geometric pattern.

Effects of kinesio taping on the gait parameters of children with cerebral palsy: a pilot study

  • Jung, Sun-Hye;Song, Sun-Hae;Kim, Da-Rye;Kim, Seul-Gi;Park, Ye-Jin;Son, Yeon-Jung;Lee, GyuChang
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.4
    • /
    • pp.205-209
    • /
    • 2016
  • Objective: Children with spastic diplegic cerebral palsy show weakness especially in the lower-extremity rather than upper-extremity muscles and display characteristics such as asymmetric alignment, deficits in postural control or balance ability, and slow walking speed. Various therapeutic interventions are applied to children with cerebral palsy, of which taping is widely used in the field of rehabilitation, however, there are few studies of the effects of kinesio taping on gait patterns of children with cerebral palsy. The present study investigated the effects of kinesio taping on gait parameters of children with cerebral palsy. Design: Cross-sectional study. Methods: Four children with spastic diplegia participated in this study. The participants' gait parameters while walking 10 m with and without kinesio taping (tibialis anterior, quadriceps femoris, and gluteus maximus) were recorded. Gait parameters including gait velocity, cadence, step length, stride length, single support time, and double support time were evaluated using the GAITRite. Mean values were obtained after having the subjects walk three times in each condition with a 5-minute rest period between each condition. The order of each condition was assigned randomly. Results: There were significant improvements in gait velocity, step length, stride length, and single support time of the right leg with kinesio taping condition compared to the without kinesio taping condition taping (p<0.05). However, there were no significant differences in cadence, single support time of the left leg, or double support time. Conclusions: The results show that kinesio taping may have a positive effect for improving gait parameters of children with spastic diplegia. However, its usefulness in the rehabilitation of children with cerebral palsy needs to be further investigated.

The Correlation of the Pressure of Biofeedback Unit and Lumbopelvic Motion During Straight Leg Raising in Healthy Subjects (정상인에서 수동적인 뻗은다리올림 시 생체되먹임 장치의 압력과 허리골반 움직임의 상관관계)

  • Jung, Do-young
    • Physical Therapy Korea
    • /
    • v.25 no.3
    • /
    • pp.12-18
    • /
    • 2018
  • Background: Passive straight leg raising (PSLR) is the common clinical test to measure of hamstring muscle length. Hip flexion angle contributes to change the lumbopelvic rotation during PSLR. Pressure biofeedback unit (PBU) is commonly used to detect lumbopelvic movement during lower limb movements. Thus, there may be the relationship between pressure of PBU and lumbopelvic motion during PSLR. Objects: The objective of this study was to determine the relationship between pressure of PBU and lumbopelvic motion during PSLR. Methods: Thirty two subjects participated in this study. A three-dimensional motion analysis system were used to measure the lumbopelvic angle during PSLR, while recording the pressure of PBU according to angle of PSLR by 10 degree increments. Pearson product moment correlations and linear regression analysis were used to describe the relationship between variables. Results: The results showed that there was a significant relationship between the lumbopelvic and angle of PSLR (Pearson's r=.83, p<.05), between the pressure of PBU and angle of PSLR (Pearson's r=.75, p<.05), and between lumbopelvic motion and pressure of PUB (Pearson's r=.83, p<.05). Linear regression equation using lumbopevic angle as an independent factor was as follows: Pressure of PBU = 47.35 + (2.55 ${\times}$ angle of lumbopelvic motion) ($R^2=.69$, p<.05). Conclusion: Results of the present study indicate that pressure of PBU can be used to indirectly detect the amounts of lumbobevic motion during muscle length test or stretching of hamstring.

A Study on the Parameter Analysis for the Quantitative Evaluation of Spasticity Implementing Pendulum Test (경직의 정량 평가를 위한 진자실험의 변수분석)

  • Lim, Hyun-Kyoon;Lee, Young-Shin;Cho, Kang-Hee;Chae, Jin-Mok;Kim, Bong-Ok
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.268-273
    • /
    • 2000
  • Velocity-dependent increase in tonic stretch reflexes is one of the prominent characteristics of spasticity. It is very important to evaluate spasticity objectively and quantitatively before and after treatment for physicians. An accurate quantitative biomechanical evaluation for the spasticity which is caused by the disorder of central nervous system is made in this study. A sudden leg dropper which is designed to generate objective testing environment at every trial gives very effective environment for the test. Kinematic data are archived by the 3-dimensional motion analysis system($Elite^{(R)}$, B.T.S., Italy). Kinematic data are angle and angular velocity of lower limb joints, and length and lengthening velocity of lower limb muscle. A program is also developed to analyze the kinematic data of lower limb, contraction and relaxation length of muscles, and dynamic EMG data at the same tim. To evaluate spasticity quantitatively, total 31 parameters extracted from goniogram, EMG and muscle model are analyzed. Statistical analysis are made for bilateral correlations for all parameters. The described instrumentation and parameters to make quantitative and objective evaluation of spasticity shows good results.

  • PDF

A Study of the Effects of Casting on Lower Limbs -Comparison of Casted and Noncasted Limb- (하지석고붕대 적용에 의한 활동저하가 석고붕대 적용하지와 비적용하지의 둘레, 피부두겹두께 및 근력에 미치는 효과)

  • 최명애;박미정;채영란
    • Journal of Korean Academy of Nursing
    • /
    • v.24 no.4
    • /
    • pp.517-528
    • /
    • 1994
  • The purpose of this study was to compare the circumference, skinfold thickness and strength of the normal and casted lower limb prior to casting and following removal of the cast. The subjects for the study were nine orthopedic patients who had had long and short leg casts due to a tibial, fibula, or calcaneus fracture, or to a lateral collateral ligament rupture. Circumference, skinfold thickness, and strength of the normal and casted lower limb following removal of the cast were compared with those prior to the application of the cast. Measurements were made before cast application and after removal of the cast. Skinfold thickness was measured by fat caliper, circumference was measured by tape and strength was determined by measuring the length of time the leg was held elevated at 45$^{\circ}$. The results can be summarized as follows 1. There was no change in the normal limb in the circumference of the midthigh and midcalf after casting as compared to before cast application. 2. In the casted limb the circumference of the midthigh decreased by 3.23% and that of the midcalf decreased significantly by 7.49% during the period of casting. 3. In the normal limb skinfold thickness of the quadriceps decreased and that of gastrocnemius increased by 20.63% during the period of cast application. 4. In the casted limb skinfold thickness of the quadriceps decreased significantly by 12.37% and that of gastrocnemius decreased by 10% during the period of cast application. 5. Strength of the normal lower extremity decreased significantly by 48.37% and that of casted lower extremity decreased remarkably by 73.07% during the period of cast application. 6. Circumference of the midthigh and the midcalf decreased significantly by 7.6% and 9.4% respectively on the casted side as compared to the normal side. Skinfold thickness of the quadriceps and the gastrocnemius on the casted side decreased by 6.12% and 18.55% respectively as compared to the normal side and strength in the lower extremity on the casted side decreased significantly by 44.32% as compared to the nor-mal side. From these results, it may be concluded that muscle atrophy occurs in the casted lower limb and muscle strength of the normal lower limb are also reduced during the period of application of a leg cast.

  • PDF

Lower Somatotype Analysis of Middle and Older Aged Women - Focused on Women in 40s to 60s - (중·노년 여성의 하반신 체형 분석 - 40대~60대 여성을 중심으로 -)

  • Kim, Hyo-Sook;Lee, So-Young;Kim, Ji-Min;Lee, Jun-Hyuk
    • Journal of the Korean Society of Costume
    • /
    • v.62 no.3
    • /
    • pp.84-95
    • /
    • 2012
  • The purpose of this study is to provide basic data reflecting body characteristics for production of briefs by classifying lower body types of women in their 40s, 50s and 60s. The results are as follows: First, measurements for height-related items decreased while the measurements for width and depth items increased with age. However, 'hip width' and 'hip depth' items showed no significant differences among the age groups. In addition, no visible differences appeared in the length items among the age groups but 'waist to hip' and 'outside leg' lengths showed decreasing values according to age. Second, four factors were established from the factor analysis: 'obesity level around waist and abdomen', 'vertical length of the lower body', 'thickness and obesity level of lower limbs', and, 'size and shape of buttocks'. Lastly, cluster analysis resulted in the classification of the four factors mentioned above. Type 2 appeared the most, representing women in their 40s~60s. Type 1(n=257) was referred as 'slender with a short lower body', Type 2(n=443) as 'plump with short lower body', Type 3(n=224) as 'slender with long lower body', and Type 4(n=199) as 'obese around abdomen and lower limbs'.

Comparison of Muscle Activity of Both Lower Extremities When a Lower Extremity Cycle Ergometer is Applied During Initial Rehabilitation After Unilateral Total Knee Arthroplasty (편측 무릎인공관절수술 후 초기 재활과정에서 다리 에르고미터 적용 시 양다리 근활성도 비교)

  • Choi, Eunji;Lee, Sangyeol;Seok, Him;Yoon, Sungyoung;Heo, Jaeseok;Lee, Seunghoon
    • PNF and Movement
    • /
    • v.20 no.2
    • /
    • pp.179-187
    • /
    • 2022
  • Purpose: The purpose of this study was to determine the asymmetrical difference between the use of leg muscles on the surgical and non-surgical sides during initial lower extremity ergometer exercise after unilateral knee arthroplasty. Methods: Twelve elderly patients diagnosed with degenerative arthritis of the knee and who underwent unilateral arthroplasty were included in this study. The leg length of each subject was taken into account when setting the application distance of the lower extremity ergometer. The same pedal resistance, strength, and speed were used for all the subjects. The total angle of use of the ergometer (360°) was analyzed by dividing it into an extension section and a flexion section. Using a surface electromyography system, the activities of the muscles of the surgical and non-surgical sides were converted into maximal voluntary isometric contraction (MVIC) and analyzed using the paired t-test. Results: When the activities of the muscles on the surgical and non-surgical sides were compared, it was found that the rectus femoris and biceps femoris had significant differences in the flexion and extension sections (p < .05), and that the tibialis anterior significantly differed in the flexion section (p < .05). There was no significant difference in the extension section of the tibialis anterior muscle, or in the flexion and extension sections of the gastrocnemius (p >.05). Conclusion: The results of this study confirm that the rectus femoris, tibialis anterior, biceps femoris, and gastrocnemius on the surgical side act in an opposite manner to those on the non-surgical side during pedaling in the same section.

Study on Physique Characteristics of Skilled Athletes

  • Kim, Bo-Kyoung;Lee, Suk-Hee;Yoon, Jung-Gyu;Jeon, Hye-Mi;Kim, Jung-Hee;Lee, Ju-Hwan;Lee, Joon-Hee;Lee, Mun-Hwan;Chang, Duncan;Choi, Wan-Suk
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.2 no.1
    • /
    • pp.244-250
    • /
    • 2011
  • The purpose of this study is to investigate whether there are differences in physique characteristics between the excellent domestic player groups in each sport player's, to prevent epidemiologic damage of musculoskeletal system and to provide fundamental data to improve performances for players. This study has performed for total 60 student players from Y University in Yongin, Gyeonggi-do, consists of 20 Kendo players, 20 Judo players and 20 Taekwondo players. We measured the length and circumference of arm, leg, body using Martin anthropometer to collect the data for 3 groups. There was significant difference in lower left arm length between player groups(p<.01), and Kendo players' right side femoral were longer than other 2 groups for leg length measurement(p<.01). Judo players' circumference for right/left stretched arm/bent upper arm were thicker than other 2 groups(p<.01). Taekwondo players' chest circumference were smaller than other 2 groups(p<.01), and Taekwondo players' right/left femoral circumference were thinner than other 2 groups(p<.05). From this study, it was found that there are physique characteristics differences between the Kendo, Judo and Taekwondo player groups. This indicates that repeated exercise for each sport player causes physique change, and it may cause epidemiologic damage of musculoskeletal system. It is recommended to perform balancing exercise prior to main exercise.