• Title/Summary/Keyword: Lower heat value

Search Result 379, Processing Time 0.023 seconds

Research on the Heat Transfer and Pressure Drop by Installation Conditions of Rectangular Obstacle in a Solar Air Heater Based on CFD (CFD를 활용한 태양열 공기가열기 내 사각저항체 설치 조건에 따른 열전달 및 압력강하에 관한 연구)

  • Choi, Hwi-Ung;Kim, Young-Bok;Son, Chang-Hyo;Yoon, Jung-In;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.1
    • /
    • pp.77-89
    • /
    • 2019
  • The solar air heater has various performances according to an obstacle installed in the air duct. Many studies on thermal performance have been conducted. But many of these studies were using a kind of rib type obstacle attached at the bottom of absorbing plate, but they are so hard to be manufactured. In this study, characteristics of the heat transfer and pressure drop in the solar air heater with various horizontal rectangular obstacles was investigated by CFD (Computational Fluid Dynamics) analysis. As a result, the heat transfer performance was improved from 1.2 to 3.32 times depending on installation conditions of rectangular obstacle. The pressure drop, however, also increased with increment of heat transfer performance from 2.8 to 180 times only by changing installation conditions of rectangular obstacle. Thus, the performance factor presenting the thermal performance enhancement on the same pressure drop was also confirmed. As a result, the highest value of 0.828 as better performance factor was obtained at the lower height of rectangular obstacle and this value has started to decrease with increment of heat transfer performance. In the end, it could be confirmed that the pressure drop was carried higher than the quantity of improvement of the heat transfer performance when the heat transfer performance was increased by change of installation conditions of rectangular obstacle. Both heat transfer enhancement and pressure drop to be required for system need to be considered before the rectangular obstacles are applied to the solar air heater.

Numerical analysis of natural convection heat transfer from a fin in parallel enclosure

  • Bae, Myung-Whan;Mochimaru, Yoshihiro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.5
    • /
    • pp.412-417
    • /
    • 2016
  • A fin of finite width with infinitely small thickness is assumed to be placed horizontally between two horizontal parallel plates of infinite extension in the exactly central position. The lower plate and the half of the upper plate are kept at a constant lower temperature, and the remaining upper plate is kept at a constant higher temperature. The fin is also kept at a constant temperature (variable). Steady-state two-dimensional laminar natural convection is analyzed as a problem of boundary value under a boundary-fitted conformal mapping system, using a spectral finite difference scheme, with a condition of doubly-connectedness. The steady-state solution is obtained as a limit of the transient solution.

Changes in Hardness and Damping Capacity of Aged Mg-5%Sn Alloy (시효한 Mg-5%Sn 합금의 경도와 진동감쇠능 변화)

  • Jun, Joong-Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.5
    • /
    • pp.255-261
    • /
    • 2022
  • In this work, the strain-amplitude independent and strain-amplitude dependent damping capacities of Mg-5%Sn alloy have been investigated as a function of its age-hardening response. The hardness increased with an increase in aging time, reached a peak value after 48 h, and then it gradually decreased. The damping capacities of the Mg-5%Sn alloy exhibited a decreasing tendency in the order of solution-treated, under-aged, peakaged, and over-aged states in the strain-amplitude dependent region, whereas they increased continuously with aging time in the strain-amplitude independent region. The microstructural examination during aging revealed that the lower concentration of Sn solutes in the α-(Mg) matrix and the lower density of the Mg2Sn precipitate particles may well be the crucial factors for better damping values in the strain-amplitude independent and strain-amplitude dependent regions, respectively.

Electrophoretic Deposition of Ni Nano-particles for Self-repairing of Heat Exchanger Tubes

  • Lee, Gyoung-Ja;Pyun, Su-Il;Rhee, Chang-Kyu
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1211-1212
    • /
    • 2006
  • The electrophoretic deposition process of Ni nano-particles was employed for self-repairing of heat exchanger tubes. For electrophoretic deposition of Ni nano-particles on pitted Ni alloy specimen, a constant electric field of 100 V $cm^{-1}$ was applied to the specimen for 180 s in Ni-dispersed solution. It was found that as electrophoretic deposition proceeded, the size of the pit remarkably decreased due to the agglomeration of Ni nano-particles at the pit. This strongly suggests that the electrophoretic mobility of the charged particles is larger for the pit with a higher current value rather than outer surfaces with a lower current value.

  • PDF

Effects of Heat Treatment on Soybeans With and Without the Gene Expression for the Kunitz Trypsin Inhibitor: Chick Growth Assays

  • Burnham, L.L.;Kim, I.H.;Hancock, J.D.;Lewis, A.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.12
    • /
    • pp.1750-1757
    • /
    • 2000
  • A total of 864 broiler chicks were used at Kansas State University and the University of Nebraska to determine the effects of heat treatment of two soybean genotypes on the growth performance. The soybeans were Williams 82 variety with (+K) and without (-K) gene expression for the Kunitz trypsin inhibitor. Heat treatment (autoclaving at $121^{\circ}C$ and $1.1kg/cm^2$) was applied for 0, 3, 6, 12, 18, and 24 min, resulting in a $2{\times}6$ factorial arrangement of treatments. Station and station treatment effects occurred, indicating that response in nutritional value of the soybean genotypes to heat treatment varied from year to year and location to location. However, the interactions were in magnitude of response rather than direction of response, with greater reductions in trypsin inhibitor concentrations for the soybeans heat processed at the Nebraska location. Pooled data indicated that -K supported greater (p<0.001) ADG, ADFI and gain/feed than the +K genotype. As the length of heat treatment increased, the ADG, ADFI, and the gain/feed ratio increased for chicks fed both soybean genotypes (p<0.0001). However, heating the -K soybeans resulted in a greater response in ADG, ADFI, and gain/feed than heating the +K soybeans (genotype heat treatment interaction, p<0.001). Pancreatic weights (mg pancreas/g of BW) of chicks fed -K soybeans were reduced compared to those from chicks fed +K (p<0.001). Increasing heat treatment decreased pancreas weights in chicks fed both soybean genotypes (p<0.001). Chicks fed heated soybeans in the Nebraska experiment had lower pancreatic weights than chicks fed heated soybeans in the Kansas experiment (station heat treatment interaction, p<0.0001). Chick growth performance was improved and pancreatic weights decreased by feeding raw -K soybeans versus raw +K soybeans, and by increasing heat treatment of both soybean genotypes. However, the response to heat treatment was not independent of genotype. Both +K and -K soybeans heated for 24 min supported similar ADG, ADFI, gain/feed, and pancreas weights, although chicks fed raw +K soybeans had lower growth performance than chicks fed -K soybeans. In conclusion, raw -K soybeans supported greater growth performance in broiler chicks than raw +K soybeans, although this advantage was lost when both soybean genotypes were heated for 24 min. Heat treatment of +K soybeans supported similar growth performance to heated -K soybeans, even though +K soybeans supported lower rates and efficiencies of gain than -K soybeans when fed raw.

Effects of Tempering Temperature and Time on Microstructure and Mechanical Property of Cu-Sn Alloy (Cu-Sn합금의 미세조직과 기계적 특성에 미치는 템퍼링 온도 및 시간의 영향)

  • Jeong, Museob;Lee, Hohyung;Han, Jun Hyun
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.33 no.2
    • /
    • pp.65-71
    • /
    • 2020
  • To study the effects of tempering on microstructure and mechanical property of Cu-22 wt.%Sn alloy, tempering was carried out for 30 sec, 1 min, 5 min, 30 min, 3 h, 5 h, and 10 h at 325, 370, 500, and 570℃, which are in the (α+ε), lower (α+δ), higher (α+δ), and (α+γ) region of Cu-Sn phase diagram, respectively. Overall, the hardness value increased and decreased over time at all tempering temperatures, and the time to reach the maximum hardness value beccame shorter as the tempering temperature increases. At the beginning of tempering at each temperature, a portion of the β' phase was decomposed into a fine (α+δ) phase or (α+γ) phase, so that the Cu-22Sn alloy had a high hardness value. However, as the tempering time increases, the hardness value of the alloy decreased due to the growth of the decomposed phases.

Influence of Disk Mass with regard to Frictional Characteristics of Brake Disk for Rolling Stock (디스크 질량 변화에 따른 철도차량용 제동디스크의 마찰 특성)

  • Jung, Jong Rok;Ko, Eun Sung;Lee, Hi Sung
    • Tribology and Lubricants
    • /
    • v.30 no.4
    • /
    • pp.240-245
    • /
    • 2014
  • Low alloy heat resistant brake disk and sintered brake pad are applied to mechanical brake system for the speed-up of urban rapid transit. In this research, we analyzed how the frictional characteristics between brake disk and pad are influenced by the disk mass. At a high disk mass, the friction stability was the lower value as a result of the lack of tribofilm formation at the disk surface. Wear rates of friction materials showed the higher value at a low disk mass and wear rates of 10 mm and 15 mm showed the similar level. Average friction coefficient was the lower value at the 10 mm disk thickness and range of variation of average friction coefficient was also the smaller value at the 10 mm disk thickness. However, there were no significant changes in the friction coefficients under any of test conditions. Surface roughness of a disk showed the highest value at the 5 mm disk and surface roughnesses of 10 mm and 15 mm showed the similar level. As a result, friction characteristics of disk mass influenced the friction stability, as well as the wear rate of friction pad and disk, but not the friction coefficient.

Strengthening of C/C Composites through Ceramer Matrix

  • Dhakate, S.R.;Mathur, R.B.;Dhami, T.L.
    • Carbon letters
    • /
    • v.5 no.4
    • /
    • pp.159-163
    • /
    • 2004
  • The polymer-ceramic hybrid, known as 'ceramer', was synthesized by a sol-gel process by incorporating different amount of alkoxide as source of silicon in resorcinol-formaldehyde in presence of basic catalyst to get different percentage of silicon in ultimate carbonized composites. FTIR of the ceramer confirms that it is a network of Si-O-Si, Si-O-$CH_2$ and Si-OH type groups linked with benzene ring. Different amount of silicon in the ceramer exhibits varying temperature of thermal stability and lower coefficient of thermal expansion as compared to pure resorcinol-formaldehyde resin. The lower value of CTE in ceramer is due to existence of silica and resorcinol -formaldehyde in co-continuous phase. Unidirectional composites prepared with ceramer matrix and high-strength carbon fibers show lower value of flexural strength at polymer stage as compared to those prepared with resorcinol-formaldehyde resin. However, after heat treatment to $1450^{\circ}C$, the ceramer matrix composites show large improvement in the mechanical properties, i.e. with 7% silicon in the ceramer, the flexural strength is enhanced by 100% and flexural modulus value by 40% as compared to that of pure resorcinol-formaldehyde resin matrix composites.

  • PDF

The Effect of refrigerant pass & distribution in aluminum parallel flow heat exchanger (알루미늄 평행류 열교환기에서 냉매패스와 분배량 변화의 영향)

  • Kim, Jeong-Sik;Kim, Nae-Hyun;Kim, Kwang-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3546-3552
    • /
    • 2009
  • In this study, an analysis code was created for a 190*650*25-mm (W*H*D) parallel-flow evaporator, and research was done on how to increase the heat transfer rate of aluminum PF heat exchanger for application in IDU. After varying the R410A refrigerant up-down flow to two and three passes and the distribution ratio to 1:1:1 and 1:2:2, it was determined that the two-pass flow has a 30% higher partial heat transfer rate and a 25% lower heat transfer coefficient compared to the three-pass flow. As for the distribution ratios of the three-pass flow, 1:1:1 was found to have a lower refrigerant pressure loss than 1:2:2 distribution. It was assumed, though, that the refrigerant distribution had a uniform flow and that its value was thus overestimated in the actual case of maldistribution in each pass.

BODY HEAT CONTENT, HEAT PRODUCTION AND RESPIRATION IN SHEEP EXPOSED TO INTERMITTENT COLD

  • Lee, S.R.;Sasaki, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.7 no.3
    • /
    • pp.357-362
    • /
    • 1994
  • Five adult sheep were exposed to intermittent cold for 12 h (18:00-06:00) at an air temperature of $5{\pm}1^{\circ}C$ followed by 12 h (06:00-18:00) at $25{\pm}2^{\circ}C$ over a period of 8 days continuously. Carotid artery blood (Tc), mean skin (Ts) and mean body (Tb = 0.86 Tc + 0.14 Ts) temperatures, heat production rate (HP), respiratory evaporative heat loss, respiration rate (RR) and volume were measured before and after exposure. Tc during the 12 h cold period of intermittent cold exposure was similar to that during the corresponding period in the warm environment, while Tc in the $25^{\circ}C$ of intermittent cold was higher (p < 0.05) than that in the corresponding period in the warm environment. Ts during the cold period markedly decreased (p < 0.001) by about $9^{\circ}C$ when compared with that in the corresponding time period in the warm environment, while Ts during the $25^{\circ}C$ period of intermittent cold recovered to a similar level to that in the warm environment. Tb was lower (p < 0.001) during the cold period of intermittent cold, whereas a slight increase in Tb during the $25^{\circ}C$ period of intermittent cold was significant (p < 0.05) when compared with the value during the similar period in the warm environment. HP was greatly increased (p < 0.001) by cold exposure, followed by an immediate decrease during the first one hour of the 12 h warm period, reaching a similar level to that in the warm environment. A lower (p < 0.05) RR was observed during both the cold and $25^{\circ}C$ period of intermittent cold than during the corresponding periods in the warm environment. The results of the present investigation clearly show that the body temperature of sheep increased during a 12 h warm period following 12 h of exposure to cold. These results suggest that during a warm period of an intermittent cold exposure cycle, heat could be shored in the animal body.