• Title/Summary/Keyword: Lower heat value

검색결과 379건 처리시간 0.021초

인장구속 균열시험에 의한 ABS EH 32강 용접부 저온 균열 감수성 시험 (The TRC Test for Cold Crack Susceptibility of Welded Zone for ABS EH32 Steel)

  • 정수원;박동환;김대헌
    • Journal of Welding and Joining
    • /
    • 제2권2호
    • /
    • pp.62-69
    • /
    • 1984
  • In this study, cold crack susceptibility of high strength steel (ABS EH32 Steel) welded zone with shielded metal are welding was investigated by tensile restraint cracking test method. Effects of diffusible hydrogen content on root cracking, lower critical stress, crack initiation and fracture mode, hardness value distribution of welded zone and fractograph were mainly investigated. Following conclusions are made: 1. In the view of the lower critical stress level, wet electrode, containing much diffusible hydrogen content shows lower value than dried electrode. 2. Hardness value(Hv 5kg) in Heat Affected Zone of wet electrode is higher than that of dried electrode caused by hydrogen embrittlement. 3. In the case of wet electrode, root crack is initiated and propagated in Heat Affected Zone and then propagated to weld metal, but using of dried electrode, root crack is initiated in Heat Affected Zone and propagated to weld metal without propagating in HAZ. 4. For wet electrode, quasi-cleavage fracture mode is majorly observed on the fracture surface of HAZ and partially of weld metal due to hydrogen embrittlement.

  • PDF

운전 조건에 따른 PEMFC 스택 열 관리 (The Heat Management of PEM Fuel Cell Stack)

  • 손익제;이종현;남기영;고재준;안병기
    • 한국수소및신에너지학회논문집
    • /
    • 제21권3호
    • /
    • pp.184-192
    • /
    • 2010
  • PEM fuel cell produces electric power, water and heat by the electrochemical reaction of hydrogen and oxygen. The heating value is dependent on the molar enthalpy of vaporization of product water and the performance loss. In this paper, the heating value of fuel cell stack has been studied under various stack operating temperatures to achieve more efficient heat management. A technology using the molar enthalpy of vaporization of product water is suggested to reduce heat-up time during start-up of a fuel cell vehicle.

수화열 해석프로그램을 이용한 기초 매스콘크리트의 사전 배합선정 및 수화열 검토 (Study on Hydration Heat and Contact the Mix-Design of Foundation Mass Concrete Using Hydration Temperature Analysis Program)

  • 설준환;조만기;방홍순;김옥규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.105-106
    • /
    • 2019
  • In this research, considering the practical conditions at field, thermal cracking method was suggested based on the comparative analysis between predicted value and actual value obtained from the actual structure member with optimum mix design. The optimum mix design was deduced from the various mix designs with various proportions of cementitious binder for upper and lower placement lifts of mat-foundation mass concrete. Therefore, it can be stated that applying low heat mix design and different heating technique between upper and lower placement lifts for mass concrete are efficient to control the thermal cracking. As future issues, based on the interpretation result value, we will select the optimal combination that is applied specifically to the actual site, and deeply analyze the correlation between the measured value and the analysis value through the combination and the test of the actual structure.

  • PDF

CNG 직접분사식 연소기에서의 열량해석(1) :균질급기 (Analysis of Heat Quantity in CNG Direct Injection Bomb(1) : Homogeneous Charge)

  • 최승환;전충환;장영준
    • 한국자동차공학회논문집
    • /
    • 제12권2호
    • /
    • pp.17-23
    • /
    • 2004
  • A cylindrical constant volume combustion bomb is used to investigate the combustion characteristics and to analyze the heat quantity of homogeneous charge methane-air mixture under various initial pressures, excess air ratios and ignition times. As the overall pressure increase, the values of maximum combustion pressure, maximum heat release rate and cumulative heat release have been increased. But it is not very meaningful to compare with some values such as maximum combustion pressure, maximum heat release rate and cumulative heat release for different overall pressure due to the different heat energy of supplied fuel. So the each value is needed to be compared with normalized value, which is divided by the entered fuel energy. To analyze the heat quantity, some definitions including the CHR ratio, the UHC ratio and the HL ratio are needed and are calculated. As the overall pressure increase, the CHR ratios and the UHC ratios have been decreased, while the HL ratios have been increased. The CHR ratio of 300 ms has the higher value than that of 10000ms, and the HL ratios of 300 ms have a lower value.

열정산방법을 이용한 사업장폐기물 소각시설의 저위발열량 분석·평가 연구 (A study on the evaluation of lower heating value using heat balance method in industrial waste incineration facilities)

  • 고영재;강준구;권영현;유하녕;권준화;장미정;전태완;신선경
    • 분석과학
    • /
    • 제31권1호
    • /
    • pp.31-38
    • /
    • 2018
  • 기존 폐기물 저위발열량 측정 분석 방법은 소량의 시료에 대한 발열량계 측정 및 원소분석 결과로 저위발열량 환산식을 적용하여 산정하도록 규정하고 있다. 즉, 기존 저위발열량 산정방법은 폐기물의 불균질성, 지역적 특성, 계절적 특성 등을 충분히 반영하지 못하여 대표성과 객관성 측면에서의 한계를 나타내고 있다. 이러한 문제로 환경부 고시(제2015-251호)에서는 저위발열량의 대표성 확보를 위하여 산정방법을 개정하였으며, "KS B 6205 육상용 보일러의 열정산방식"을 바탕으로 열정산방법을 적용한 사업장폐기물 소각시설에서의 저위발열량 산정방법을 제시하고 있다. 본 연구에서는 현재 운영 중인 사업장폐기물 소각시설을 대상으로 열정산법에 따라 시설별 투입 폐기물의 저위발열량을 분석 평가하였다. 사업장폐기물 소각시설 7 개소 (10 개호기)에 대한 저위발열량 평가 결과 평균 약 3,404.7 kcal/kg로 산정되었으며, 세부 산정 인자에는 실제 시설 운영 데이터를 수집 종합 하여 적용하였다. 본 연구에서 적용한 개정된 저위발열량 산정 방법은 불균질한 성상의 폐기물 특성을 반영할 수 있는 방법으로, 기존 폐기물 발열량 산정방법과 비교하여 보다 객관성을 확보한 방법인 것으로 판단된다. 본 연구의 결과는 추후 세부적인 저위발열량 산정방법 개선 및 산정인자 도출 등을 위한 기초자료로 활용 될 수 있을 것으로 판단된다.

판각형 열교환기내의 R-134a 증발열전달 특성에 관한 실험적 연구 (Experimental Study on R-134a Evaporation Heat Transfer Characteristics in Plate and Shell Heat Exchanger)

  • 김수진;박재홍;서무교;김영수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.248-253
    • /
    • 2001
  • An experiment was carried out to investigate the characteristics of the evaporation heat transfer for refrigerant R-134a flowing in a plate and shell heat exchanger. The data are useful in designing more compact and effective evaporators for various refrigeration and air conditioning systems. Two vertical counterflow channels were formed in the exchanger. The R-134a flows up in one channel exchanging heat with the hot water flowing down in the other channel. The effects of the average heat flux, mass flux, saturation temperature and vapor quality were examined in detail. The present data show that the evaporation heat transfer coefficient increases with the vapor quality. A rise in the refrigerant mass flux causes an increase in the $h_r$ value. A rise in the average imposed heat flux causes an increase in the $h_r$, value at the low quality. Finally, at a higer refrigerant saturation temperature the $h_r$, value is found to be lower.

  • PDF

Sn-Zn 공정합금(共晶合金)의 응고속도(凝固速度)에 따른 조직(組織)과 기계적(機械的) 성질(性質)에 관한 연구(硏究) (A Study on the Morpholgies and Mechanical Properties of Sn-Zn Eutectic Alloys)

  • 이주형;이계완
    • 한국주조공학회지
    • /
    • 제5권4호
    • /
    • pp.258-270
    • /
    • 1985
  • The structures and mechanical properties of undirectionally solidified Sn-Zn eutectic alloys have been examined over the growth range 7mm/h to 6,000mm/h. The structures of unidirectionally solidified Sn-Zn eutectic alloys were primarily broken-lamellar at growth rates below 760mm/h and became fibrous at higher growth rates above that. At a growth rate 3,084mm/h the structures were fibrouse only. There is no dendrites at any growth rates, but occasionally ribbon-like morphologies were seen. The under cooling increased parabolically with growth rate increase. The hardness of specimes increased with growth rates increase but heat-treated specimen decreased after growth rates 760mm/h and became constant value. The effect of heat-treatment was good at lower growth rate. At room temperature tensile strength increased with growth rates up to R=990mm/h and then tensile strength became near-constant value. The effect of heat-treatment was well at lower growth rate.

  • PDF

열처리 온도 및 냉각방법이 Cu-22Sn합금의 미세조직 및 경도변화에 미치는 영향 (Effects of Heat Treatment Temperature and Cooling Method on Microstructure and Hardness of Cu-22Sn alloy)

  • 정무섭;신아리;한준현
    • 열처리공학회지
    • /
    • 제31권3호
    • /
    • pp.104-110
    • /
    • 2018
  • The effects of heat treatment time and cooling method on microstructure and mechanical property of Cu-22wt%Sn alloy were discussed. ${\alpha}+{\delta}$ mixed phase structure was obtained in air-cooled specimens after heat treatment at 775, 750, and $700^{\circ}C$ for 1 hour. On the other hand, in water-cooled specimens, ${\alpha}+{\beta}^{\prime}$ martensite mixed phase was obtained. In the case of water-cooled specimens, the hardness value decreased with decreasing heat treatment temperature because the volume fraction of ${\alpha}$ phase with low hardness value increased as the heat treatment temperature decreased. In water-cooled specimen after heat treatment at $600^{\circ}C$, ${\gamma}^{\prime}$ martensite was formed instead of ${\beta}^{\prime}$ martensite. The hardness value of ${\gamma}^{\prime}$ martensite was lower than those of ${\beta}^{\prime}$ and ${\delta}$ phases.

알칼리 자극제 혼입 고로슬래그 미분말의 공극구조 및 미소수화열 분석 (Pore Structure and Heat of Microhydration Analysis of Blast Furnace Slag Containing Alkaline Activator)

  • 박지웅;박희곤;김우재;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.20-21
    • /
    • 2017
  • In this study, fundamental properties by pore structure and heat of microhydration test were determined. As a result of pore structure analysis, BS(AA) specimen showed showed the maximum peak value of significantly lower incremental intrusion than the maximum peak value of incremental intrusion at smaller pore size than that of BS. As a result of heat of microhydration test, the maximum heating value was in the order of OPC > BS > BS(AA), and initial drying shrinkage and compressive strength of BS(AA) were expected to be improved.

  • PDF

팜(PALM) 기름 안정성 향상을 위한 항산화제 적정첨가조건 조사 (Studies on the Find out of Optimum Condition with Treated Antioxidants for the Stability of PALM Oil after Frying)

  • 이형재;이성갑
    • 기술사
    • /
    • 제31권5호
    • /
    • pp.110-120
    • /
    • 1998
  • The effect of heat treatment and the order of antioxidants treatment toward the thermally oxidized palm oil which has been stored at 60 $^{\circ}C$ was studied. The summerized results of this study are as follows; 1. In the accelerated autoxidation condition, tocopherol showed no distinct effect on the changes of peroxide of value between added tocopherol samples pre-and post treatment by heating. But, rosemary extract showed opposite result. It was supposed that rosemary extract had lower thermostability then tocopherol, because rosemary extract lost it's antioxidative activity during heating process. 2. The changes of acid value and anisidine value were more affected by heat treatment than the order of antioxidant treatment. 3. The oxidative stability measured by OSI showed same tendency as peroxide value. That is, the antioxidative activity of tocopherol in palm oil was more dependent on addition of antioxidants than heat treatment, but the rosemary extract had opposite character for antioxidative action in palm oil.

  • PDF