• Title/Summary/Keyword: Lower heat value

Search Result 379, Processing Time 0.027 seconds

The TRC Test for Cold Crack Susceptibility of Welded Zone for ABS EH32 Steel (인장구속 균열시험에 의한 ABS EH 32강 용접부 저온 균열 감수성 시험)

  • 정수원;박동환;김대헌
    • Journal of Welding and Joining
    • /
    • v.2 no.2
    • /
    • pp.62-69
    • /
    • 1984
  • In this study, cold crack susceptibility of high strength steel (ABS EH32 Steel) welded zone with shielded metal are welding was investigated by tensile restraint cracking test method. Effects of diffusible hydrogen content on root cracking, lower critical stress, crack initiation and fracture mode, hardness value distribution of welded zone and fractograph were mainly investigated. Following conclusions are made: 1. In the view of the lower critical stress level, wet electrode, containing much diffusible hydrogen content shows lower value than dried electrode. 2. Hardness value(Hv 5kg) in Heat Affected Zone of wet electrode is higher than that of dried electrode caused by hydrogen embrittlement. 3. In the case of wet electrode, root crack is initiated and propagated in Heat Affected Zone and then propagated to weld metal, but using of dried electrode, root crack is initiated in Heat Affected Zone and propagated to weld metal without propagating in HAZ. 4. For wet electrode, quasi-cleavage fracture mode is majorly observed on the fracture surface of HAZ and partially of weld metal due to hydrogen embrittlement.

  • PDF

The Heat Management of PEM Fuel Cell Stack (운전 조건에 따른 PEMFC 스택 열 관리)

  • Son, Ik-Jae;Lee, Jong-Hyun;Nam, Gi-Young;Ko, Jae-Jun;Ahn, Byung-Ki
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.3
    • /
    • pp.184-192
    • /
    • 2010
  • PEM fuel cell produces electric power, water and heat by the electrochemical reaction of hydrogen and oxygen. The heating value is dependent on the molar enthalpy of vaporization of product water and the performance loss. In this paper, the heating value of fuel cell stack has been studied under various stack operating temperatures to achieve more efficient heat management. A technology using the molar enthalpy of vaporization of product water is suggested to reduce heat-up time during start-up of a fuel cell vehicle.

Study on Hydration Heat and Contact the Mix-Design of Foundation Mass Concrete Using Hydration Temperature Analysis Program (수화열 해석프로그램을 이용한 기초 매스콘크리트의 사전 배합선정 및 수화열 검토)

  • Seol, Jun-Hwan;Jo, Man-Ki;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.105-106
    • /
    • 2019
  • In this research, considering the practical conditions at field, thermal cracking method was suggested based on the comparative analysis between predicted value and actual value obtained from the actual structure member with optimum mix design. The optimum mix design was deduced from the various mix designs with various proportions of cementitious binder for upper and lower placement lifts of mat-foundation mass concrete. Therefore, it can be stated that applying low heat mix design and different heating technique between upper and lower placement lifts for mass concrete are efficient to control the thermal cracking. As future issues, based on the interpretation result value, we will select the optimal combination that is applied specifically to the actual site, and deeply analyze the correlation between the measured value and the analysis value through the combination and the test of the actual structure.

  • PDF

Analysis of Heat Quantity in CNG Direct Injection Bomb(1) : Homogeneous Charge (CNG 직접분사식 연소기에서의 열량해석(1) :균질급기)

  • 최승환;전충환;장영준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.17-23
    • /
    • 2004
  • A cylindrical constant volume combustion bomb is used to investigate the combustion characteristics and to analyze the heat quantity of homogeneous charge methane-air mixture under various initial pressures, excess air ratios and ignition times. As the overall pressure increase, the values of maximum combustion pressure, maximum heat release rate and cumulative heat release have been increased. But it is not very meaningful to compare with some values such as maximum combustion pressure, maximum heat release rate and cumulative heat release for different overall pressure due to the different heat energy of supplied fuel. So the each value is needed to be compared with normalized value, which is divided by the entered fuel energy. To analyze the heat quantity, some definitions including the CHR ratio, the UHC ratio and the HL ratio are needed and are calculated. As the overall pressure increase, the CHR ratios and the UHC ratios have been decreased, while the HL ratios have been increased. The CHR ratio of 300 ms has the higher value than that of 10000ms, and the HL ratios of 300 ms have a lower value.

A study on the evaluation of lower heating value using heat balance method in industrial waste incineration facilities (열정산방법을 이용한 사업장폐기물 소각시설의 저위발열량 분석·평가 연구)

  • Ko, Youngjae;Kang, Jun-Gu;Kwon, Young-Hyun;Yoo, Ha-Nyoung;Kwon, Jun-Hwa;Jang, Mi-Jeong;Jeon, Tae-Wan;Shin, Sun-Kyoung
    • Analytical Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.31-38
    • /
    • 2018
  • The energy recovery rate estimation method proposed through the Waste Control Act does not take into account the energy used in practice. In addition, the method for measuring a lower heating value, which is the main factor of the energy recovery rate, was carried out through a small sampling amount, and thus the representative value of the waste was not reflected. With the revised estimation method (Notification No. 2015-215 of the Ministry of Environment), the energy recovery rate should be estimated based on the actual amount of energy used, and a heat balance method was proposed as a way to estimate the lower heating value. In this study, the lower heating value was estimated for seven industrial waste incineration facilities according to the revised estimation method. All data used in the estimations were achieved from measurement instruments applied to each of the incinerators and through direct measurements taken by the operators for the purposes of calculation. As a result, the lower heating value was estimated to be about 3,404.7 kcal/kg for the seven industrial waste incineration facilities.

Experimental Study on R-134a Evaporation Heat Transfer Characteristics in Plate and Shell Heat Exchanger (판각형 열교환기내의 R-134a 증발열전달 특성에 관한 실험적 연구)

  • Kim, Su-Jin;Park, Jae-Hong;Seo, Moo-Gyo;Kim, Young-Soo
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.248-253
    • /
    • 2001
  • An experiment was carried out to investigate the characteristics of the evaporation heat transfer for refrigerant R-134a flowing in a plate and shell heat exchanger. The data are useful in designing more compact and effective evaporators for various refrigeration and air conditioning systems. Two vertical counterflow channels were formed in the exchanger. The R-134a flows up in one channel exchanging heat with the hot water flowing down in the other channel. The effects of the average heat flux, mass flux, saturation temperature and vapor quality were examined in detail. The present data show that the evaporation heat transfer coefficient increases with the vapor quality. A rise in the refrigerant mass flux causes an increase in the $h_r$ value. A rise in the average imposed heat flux causes an increase in the $h_r$, value at the low quality. Finally, at a higer refrigerant saturation temperature the $h_r$, value is found to be lower.

  • PDF

A Study on the Morpholgies and Mechanical Properties of Sn-Zn Eutectic Alloys (Sn-Zn 공정합금(共晶合金)의 응고속도(凝固速度)에 따른 조직(組織)과 기계적(機械的) 성질(性質)에 관한 연구(硏究))

  • Lee, J.H.;Lee, K.W.
    • Journal of Korea Foundry Society
    • /
    • v.5 no.4
    • /
    • pp.258-270
    • /
    • 1985
  • The structures and mechanical properties of undirectionally solidified Sn-Zn eutectic alloys have been examined over the growth range 7mm/h to 6,000mm/h. The structures of unidirectionally solidified Sn-Zn eutectic alloys were primarily broken-lamellar at growth rates below 760mm/h and became fibrous at higher growth rates above that. At a growth rate 3,084mm/h the structures were fibrouse only. There is no dendrites at any growth rates, but occasionally ribbon-like morphologies were seen. The under cooling increased parabolically with growth rate increase. The hardness of specimes increased with growth rates increase but heat-treated specimen decreased after growth rates 760mm/h and became constant value. The effect of heat-treatment was good at lower growth rate. At room temperature tensile strength increased with growth rates up to R=990mm/h and then tensile strength became near-constant value. The effect of heat-treatment was well at lower growth rate.

  • PDF

Effects of Heat Treatment Temperature and Cooling Method on Microstructure and Hardness of Cu-22Sn alloy (열처리 온도 및 냉각방법이 Cu-22Sn합금의 미세조직 및 경도변화에 미치는 영향)

  • Jeong, Museob;Shin, Ari;Han, Jun Hyun
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.31 no.3
    • /
    • pp.104-110
    • /
    • 2018
  • The effects of heat treatment time and cooling method on microstructure and mechanical property of Cu-22wt%Sn alloy were discussed. ${\alpha}+{\delta}$ mixed phase structure was obtained in air-cooled specimens after heat treatment at 775, 750, and $700^{\circ}C$ for 1 hour. On the other hand, in water-cooled specimens, ${\alpha}+{\beta}^{\prime}$ martensite mixed phase was obtained. In the case of water-cooled specimens, the hardness value decreased with decreasing heat treatment temperature because the volume fraction of ${\alpha}$ phase with low hardness value increased as the heat treatment temperature decreased. In water-cooled specimen after heat treatment at $600^{\circ}C$, ${\gamma}^{\prime}$ martensite was formed instead of ${\beta}^{\prime}$ martensite. The hardness value of ${\gamma}^{\prime}$ martensite was lower than those of ${\beta}^{\prime}$ and ${\delta}$ phases.

Pore Structure and Heat of Microhydration Analysis of Blast Furnace Slag Containing Alkaline Activator (알칼리 자극제 혼입 고로슬래그 미분말의 공극구조 및 미소수화열 분석)

  • Park, Ji-Woong;Park, Hee-Gon;Kim, Woo-Jae;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.20-21
    • /
    • 2017
  • In this study, fundamental properties by pore structure and heat of microhydration test were determined. As a result of pore structure analysis, BS(AA) specimen showed showed the maximum peak value of significantly lower incremental intrusion than the maximum peak value of incremental intrusion at smaller pore size than that of BS. As a result of heat of microhydration test, the maximum heating value was in the order of OPC > BS > BS(AA), and initial drying shrinkage and compressive strength of BS(AA) were expected to be improved.

  • PDF

Studies on the Find out of Optimum Condition with Treated Antioxidants for the Stability of PALM Oil after Frying (팜(PALM) 기름 안정성 향상을 위한 항산화제 적정첨가조건 조사)

  • 이형재;이성갑
    • Journal of the Korean Professional Engineers Association
    • /
    • v.31 no.5
    • /
    • pp.110-120
    • /
    • 1998
  • The effect of heat treatment and the order of antioxidants treatment toward the thermally oxidized palm oil which has been stored at 60 $^{\circ}C$ was studied. The summerized results of this study are as follows; 1. In the accelerated autoxidation condition, tocopherol showed no distinct effect on the changes of peroxide of value between added tocopherol samples pre-and post treatment by heating. But, rosemary extract showed opposite result. It was supposed that rosemary extract had lower thermostability then tocopherol, because rosemary extract lost it's antioxidative activity during heating process. 2. The changes of acid value and anisidine value were more affected by heat treatment than the order of antioxidant treatment. 3. The oxidative stability measured by OSI showed same tendency as peroxide value. That is, the antioxidative activity of tocopherol in palm oil was more dependent on addition of antioxidants than heat treatment, but the rosemary extract had opposite character for antioxidative action in palm oil.

  • PDF