• 제목/요약/키워드: Lower flash point

검색결과 105건 처리시간 0.027초

Setaflash 장치를 이용한 노말 알코올류의 상부인화점 측정에 의한 폭발상한계의 예측 (Prediction of Upper Explosion Limits(UEL) by Measurement of Upper Flash Point Using Setaflash Apparatus for n-Alcohols)

  • 하동명
    • 한국안전학회지
    • /
    • 제25권2호
    • /
    • pp.35-40
    • /
    • 2010
  • Explosion limit and flash point are the major combustion properties used to determine the fire and explosion hazards of the flammable substances. In this study, in order to predict upper explosion limits(UEL), the upper flash point of n-alcohols were measured under the VLE(vapor-liquid equilibrium) state by using Setaflash closed cup tester(ASTM D3278). The UELs calculated by Antoine equation using the experimental upper flash point are usually lower than the several reported UELs. From the given results, using the proposed experimental and predicted method, it is possible to research the upper explosion limits of the other flammable substances.

노말도데칸의 인화점과 최소발화온도 측정에 의한 연소위험성 고찰 (The Investigation of Combustible Hazard by Measurement of Flash Point and Autoignition Temperature of n-Dodecane)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.120-125
    • /
    • 2011
  • 노말도데칸의 안전한 취급을 위해서 25에서 폭발한계를 고찰하였고, 하부인화점과 발화지연시간에 의한 발화온도를 측정하였다. 공정의 안전을 위해서 노말도데칸의 폭발하한계는 0.60Vol.%, 상한계는 4.7Vol.%를 추천하였고, 하부인화점은 밀폐계에서 $77^{\circ}C$$80^{\circ}C$와 개방식에서 $84{\sim}87^{\circ}C$로 측정되었다. ASTM E659-78 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 최소자연발화온도는 $222^{\circ}C$ 측정되었다.

에틸벤젠의 연소특성치 측정 및 예측 (The Measurement and Prediction of Combustible Properties for Ethylbenzene)

  • 하동명
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.169-175
    • /
    • 2014
  • 에틸벤젠의 안전한 취급을 위해, 폭발한계는 문헌을 통해 고찰하였으며, 인화점과 발화지연시간에 의한 자연발화온도는 시험장치를 이용하여 측정하였다. 인화점의 경우 밀폐식 장치인 Setaflash와 Penski-Martens에 의한 하부인화점은 각 각 $20^{\circ}C$$22^{\circ}C$로 측정되었으며, 개방식인 Tag와 Cleveland에서는 각 각 $25^{\circ}C$$28^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 최소자연발화온도는 $430^{\circ}C$로 측정되었다. 에틸벤젠의 측정된 인화점을 이용하여 폭발하한계와 상한계는 0.93 Vol.%와 7.96 Vol.%로 계산되었다.

The Prediction of Lower Flash Points by Optimization Method

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • International Journal of Safety
    • /
    • 제8권2호
    • /
    • pp.15-19
    • /
    • 2009
  • The flash point is the most widely used flammability property for the evaluation of the flammability hazard of combustible liquid mixtures. In this paper, the reported flash points for the the binary systems, ethylbenzene+n-butanol and ethylbenzene+n-hexanol were correlated by the optimization method. The optimization method based on the van Laar and Wilson equations were compared with the Raoult's law. The calculated values based on the optimization method were found to be better than those based on the Raoult's law.

Methanol, Ethanol, 2-Propanol 그리고 1-Butanol 이성분 혼합계에 대한 101.3 kPa에서의 인화점 측정 및 예측 (The Measurement and Prediction of Flash Point for Binary Mixtures of Methanol, Ethanol, 2-Propanol and 1-Butanol at 101.3 kPa)

  • 오인석;인세진
    • 한국화재소방학회논문지
    • /
    • 제29권5호
    • /
    • pp.1-6
    • /
    • 2015
  • 인화점은 화재 및 액체의 폭발 위험의 가능성을 결정하는 데 사용되는 가장 중요한 물리적 특성이고, 산업공정에서 안정성 평가시 중요한 연소특성 가운데 하나이다. 따라서 본 연구는 4류 위험물 중 알코올계 혼합물인 {methanol + 1-butanol}, {ethanol + 1-butanol} 그리고 {2-propanol + 1-butanol} 이성분계 101.3 kPa에서 최소인화점을 SETA closed cup flash point tester를 이용하여 측정하였다. 각 이성분계에 대하여 Wilson, NRTL 및 UNIQUAC 파라미터를 이용하여 혼합물에 대한 인화점 예측하고 실험 결과와 비교하였다. 비교결과 모든 예측값과 실험값은 유사한 값을 보였고 편차가 1.14 K 이내의 결과를 보였다.

The Correlation of Lower Flash Point data with Activity Coefficient Models

  • Ha, Dong-Myeong;Lee, Sungjin
    • International Journal of Safety
    • /
    • 제10권1호
    • /
    • pp.5-9
    • /
    • 2011
  • Two popular activity coefficient models, Wilson and NRTL equations have been used to correlate the published flash point data on the n-propanol + propionic acid and n-butanol + propionic acid systems through the optimization method. The results of these correlation were compared with the results calculated by Raoult's law. The optimization method were found to be better than those based on the Raoult's law. The optimization method based on the Wilson equation described the published data more effectively than was the case when the optimization method was based upon the NRTL equation.

  • PDF

3-헥사논의 화재 및 폭발 특성치의 측정 및 예측 (Measurement and Prediction of Fire and Explosion Properties of 3-Hexanone)

  • 하동명
    • 한국가스학회지
    • /
    • 제17권6호
    • /
    • pp.33-38
    • /
    • 2013
  • 3-헥사논의 안전한 취급을 위해, 폭발한계는 문헌을 통해 고찰하였고, 인화점과 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 밀페식 장치에 의한 3-헥사논(에틸프로필케톤)의 하부인화점은 $18^{\circ}C$로 측정되었으며, 개방식에서는 $27^{\circ}C{\sim}32^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 3-헥사논의 최소자연발화온도는 $425^{\circ}C$로 측정되었다. 측정된 인화점에 의한 폭발하한계는 1.21 Vol%로 계산되었다.

아니솔의 연소특성치의 측정에 의한 MSDS의 적정성 (Appropriateness of MSDS by Means of the Measurement of Combustible Properties of Anisole)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제29권2호
    • /
    • pp.20-24
    • /
    • 2015
  • 아니솔의 안전한 취급을 위해, 폭발한계는 문헌을 통해 고찰하였고, 인화점과 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 밀폐식 장치에 의한 아니솔의 하부인화점은 $39^{\circ}C$$42^{\circ}C$로 측정되었으며, 개방식에서는 $50^{\circ}C$$54^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 아니솔의 최소자연발화온도는 $390^{\circ}C$로 측정되었다. 측정된 하부인화점에 의한 폭발하한계는 1.07 Vol%로 계산되었다.

Methanol, Ethanol, 1-propanol 그리고 Toluene 이성분 혼합계에 대한 인화점 측정 (Measurement of Flash Point for Binary Mixtures of Methanol, Ethanol, 1-propanol and Toluene)

  • 황인찬;김선우;인세진
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.1-6
    • /
    • 2018
  • 인화점은 산업현장에서 액체의 화재 및 폭발 위험을 결정하는데 사용되는 가장 중요한 변수 중 하나로써 가연성 물질의 화재 위험성을 나타내는 지표이며 안정성 평가에 많이 사용되고 있다. 따라서 본 연구는 다양한 산업에서 용매로 사용되는 이성분계 혼합물 중 {methanol+toluene}, {ethanol+toluene} 그리고 {1-propanol+toluene}에 대한 인화점을 SETA 밀폐식 인화점 측정기를 이용하여 측정하였다. 각 이성분계 혼합물에 대한 인화점을 예측하기 위해 Raoult's의 법칙, Wilson, NRTL 및 UNIQUAC 파라미터를 이용하였고 실험 결과와 비교하였다. Raoult's의 법칙을 제외한 비교 결과, 모든 예측값과 실험값은 유사한 값을 보였고 편차가 1.69 K이내의 결과를 보였다.

삼성분계 혼합물인 n-Nonane+n-Decane+n-Dodecane 계의 하부인화점 측정 (Measurement of Lower Flash Point for Ternary Mixture, n-Nonane+n-Decane+n-Dodecane System)

  • 하동명;이성진
    • 한국가스학회지
    • /
    • 제20권6호
    • /
    • pp.31-36
    • /
    • 2016
  • 인화점은 액체 용액의 가장 중요한 인화성 지표 중 하나이다. 인화점은, 가연성 증기의 공기 속 농도가 점화가 발생하기에 충분할 때의 온도 중 가장 낮은 온도이다. 본 연구에서는 삼성분계 액체 용액인, n-nonane+n-decane+n-dodecane acid 계의 인화점을 Seta flash 밀폐식 장치를 사용하여 측정하였다. 실험값은 라울의 법칙을 활용한 방법과 실험식에 의한 계산값과 비교되었다. 그 결과 실험식에 의한 계산값이 라울의 법칙에 의한 계산값 보다 측정값을 잘 모사하였다.