• Title/Summary/Keyword: Lower distortion

Search Result 282, Processing Time 0.024 seconds

Analysis of total harmonic distortion in microspeaker considering coupling effect (연성 효과를 고려한 마이크로스피커 왜율분석)

  • Kwon, Joong-Hak;Kim, Kwang-Suk;Bang, Ki-Chang;Hwang, Sang-Moon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.236-241
    • /
    • 2008
  • With the advent of mobile phone, Digital multimedia broadcasting (DMB) service is to be realized for multimedia data communication. For an acoustic part, a smaller and lighter microspeaker is also soon to be realized as an MP3 song player and a speakerphone. Sound quality in the microspeaker is becoming more important in mobile phones. It is evaluated by total harmonic distortion (THD). THD is the proportion of higher order frequencies output response to sinusoidal input signal. It is affected by uneven magnetic distribution and nonlinear response of diaphragm. In this paper, harmonic distortion is analyzed by considering magnetic and mechanical coupling effects. Simulated results of THD are compared with experimental data. Results show that THD in lower frequency range is higher due to high displace on voice coil and high mechanical response of high order frequency.

  • PDF

Distortion Elimination for Buck PFC Converter with Power Factor Improvement

  • Xu, Jiangtao;Zhu, Meng;Yao, Suying
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.10-17
    • /
    • 2015
  • A quasi-constant on-time controlled buck front end in combined discontinuous conduction mode and boundary conduction mode is proposed to improve power factor (PF).When instantaneous AC input voltage is lower than the output bus voltage per period, the buck converter turns into buck-boost converter with the addition of a level comparator to compare input voltage and output voltage. The gate drive voltage is provided by an additional oscillator during distortion time to eliminate the cross-over distortion of the input current. This high PF comes from the avoidance of the input current distortion, thereby enabling energy to be delivered constantly. This paper presents a series analysis of controlling techniques and efficiency, PF, and total harmonic distortion. A comparison in terms of efficiency and PF between the proposed converter and a previous work is performed. The specifications of the converter include the following: input AC voltage is from 90V to 264V, output DC voltage is 80V, and output power is 94W.This converter can achieve PF of 98.74% and efficiency of 97.21% in 220V AC input voltage process.

Effects of Stainless Steel Plate-Patterns on the Thermal Distortion and Surface Temperature of Aluminum Frypan (알루미늄 프라이팬에 부착된 스텐리스판의 패턴이 열 변형 및 표면온도에 미치는 영향)

  • Moon, Sungmo;Yoon, Myungsik
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.5
    • /
    • pp.227-231
    • /
    • 2020
  • This article investigated the effects of stainless steel plate-patterns bonded to aluminum frypan on the thermal distortion and surface temperature of the frypan during gas or induction heating. Two different stainless steel plate-patterns were employed: type A contains only circular holes and type B has not only circular holes but also vacant spaces of 0.5 mm thick and 40 mm long straight line crossing 60 mm long curved line. The bottom of the frypan was distorted during heating when type A stainless steel plate-bonded frypan while no significant thermal distortion was observed for type B stainless steel plate-bonded frypan during heating. Temperature of the frypan surface showed the same trend during gas heating, irrespective of stainless steel plate-patterns. During induction heating, however, the frypan with type B stainless steel plate-pattern showed lower surface temperature than the frypan with type A stainless steel plate-pattern. It is concluded that Type B stainless steel plate-pattern with circular holes and vacant spaces of lines is very effective for minimizing a thermal distortion and lowering the surface temperature of an aluminum frypan during induction heating.

The Utility of Single Shot Turbo Spin Echo Technique for Temporal Bone Diffusion Weighted Imaging (관자뼈의 확산강조영상검사 시 Single Shot Turbo Spin Echo 기법의 유용성)

  • Choi, Kwan-Woo
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.25-30
    • /
    • 2021
  • The purpose was to reduce the distortion of the image that occurs in the temporal bone area due to the very strong differences in susceptibility. A new SS-TSE technique was applied when examining the diffusion-weighted image of the temporal bone, where the auditory and facial nerves to be imaged were very thin and were adjacent to the cranial base including bone and air. This study was conducted from March 2020 to August of the same year, targeting 32 subjects who underwent the diffusion-weighted imaging of the temporal bone. To compare the distortion, existing SS-EPI technique and the new SS-TSE technique were both applied on the temporal bone area. As a result of the study, applying the new SS-TSE technique appeared to lower the distortion of images by 87.44, 46.13 and 42.35 % on the b-value 0, 800 and the ADC images, respectively. In conclusion, when using the new SS-TSE technique on the temporal bone DWI, distortion can be reduced, and thus images with high diagnostic value can be obtained.

A Clinical Study on the Dimensional Accuracy of the Combined Impression (Alginate & Agar-Agar) (Alginate와 Agar-Agar에 의한 연합인상법의 촌법정도에 관한 임상적 연구)

  • Ha, Ju-Tai;Lee, Jung-Man;Choi, Boo-Byung
    • The Journal of the Korean dental association
    • /
    • v.17 no.9 s.124
    • /
    • pp.701-708
    • /
    • 1979
  • A series of combined impressions, alginate impressions and rubber base impression made of the lower left quadrant of one subject having a cast gold crown with six reference marks on lower let 1st molar. the combined impressions of hydrocolloid were removed from the mouth at 2.5min, after the insertion of the tray. The alginate impressions were removed from the mouth at 2min, after the insertion of the tray. The rubber base impressions were removed from the mouth at 10min. The effect on the accuracy of the combined impressions, alginate impressions and rubber base impressions was obtained following results by comparing the distances between the reference marks in indirect stone cast with the standard measurements of the cast gold crown prior to cementation. The findings through this study could be summarized as follows; 1. The accuracy of combined impression was superior to that of alginate impression, but it was inferior to that of rubber base impressions. 2. Combined impressions produced a little distortion of the mesio-distal length, alginate impressions produced the largest distortion, ut rubber base impressions produced the least distortion.

  • PDF

A study of Single-phase Voltage Source PWM Converter for High Power Factor (고역률 제어를 위한 단산 전압원 PWM 컨버터에 관한 연구)

  • 류성식;손진근;정을기;김형원;전희종
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.362-365
    • /
    • 1999
  • In this paper, the method of reducing harmonics and correcting of power factor in single PWM converter associated with diode rectifier and boos converter is studied. The ac-dc converter in which the harmonic distortion in the input current is reduced using a third harmonic injected PWM is proposed. A lower switching power loss and easy configuration o control circuit are obtained by adopting discontinuous current mode. Simulation and experimental results of ac-dc converter with 5[KHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

Pelvic Twist Analysis, PTA (골반 뒤틀림 변위 분석법에 대한 소고)

  • Jo, Jong-Jin;Kim, Sang-Deok
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.5 no.1
    • /
    • pp.135-139
    • /
    • 2004
  • Objectives : The objectives of this report is to introduce PTA. Methods : The examination of the leg length inequality gives us a useful tool for diagnosis of body imbalance. especially pelvic distortion. There are four steps in the process of the leg analysis, according to "The Standard Manual of Chuna Society (2nd ed., Seoul:KCA Press. 2001)". In the last step of the analysis, knee-flexing over $90^{\circ}$, we have often experienced a specific sign that the lower legs are attracted toward one side spontaneously. The authors call it 'Lower Leg Lateral Attraction'. This is a very significant sign that gives us which is the major part between pelvis and the upper parts over sacrum. Thus it is definded as "Pelvic Twist Analysis, PTA" by the authors. With PTA, first, you must check the side of short leg and next, check the side of lateral attraction in lower leg over-flexing. If both sides coincide with each other, then the major part you can correct first is pelvic distortion. If not, you must find another part for primary correction, instead of pelvis. Conclusions : PTA becomes a useful complement to the examination of the leg length inequality.

  • PDF

Scaling methods for wind tunnel modelling of building internal pressures induced through openings

  • Sharma, Rajnish N.;Mason, Simon;Driver, Philip
    • Wind and Structures
    • /
    • v.13 no.4
    • /
    • pp.363-374
    • /
    • 2010
  • Appropriate scaling methods for wind tunnel modelling of building internal pressures induced through a dominant opening were investigated. In particular, model cavity volume distortion and geometric scaling of the opening details were studied. It was found that while model volume distortion may be used to scale down buildings for wind tunnel studies on internal pressure, the implementation of the added volume must be done with care so as not to create two cavity resonance systems. Incorrect scaling of opening details was also found to generate incorrect internal pressure characteristics. Furthermore, the effective air slug or jet was found to be longer when the opening was near a floor or sidewall as evidenced by somewhat lower Helmholtz frequencies. It is also shown that tangential flow excitation of Helmholtz resonance for off-centre openings in normal flow is also possible.

THE STUDY OF APICAL CHANGES ON THE ORTHOPANTOMOGRAPH (Orthopantomograph에 있어서 치근부 상의 변화에 관한 연구)

  • Ahn Hyung Kyu
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.9 no.1
    • /
    • pp.19-23
    • /
    • 1979
  • A study was made primarily to investigate vertical and horizontal distortion of the image at the apical region of the dental roots in orthopantomographs. The subjects consisted of two dry skulls with radiopaque materials attached to root surface. Measuring of the width and length of each predetermined point at 23 teeth was performed in dry skulls and radiographic films. The results obtained were as follows; 1. There was overall magnification of image in the vertical dimension. And anterior portion had greater magnification rate than posterior portion, while lower anterior portion had less magnification rate than upper anterior portion. 2. There was reduction of the image in the horizontal dimension of the teeth, because of the position relation between dry skull and image layer of the orthopantomograph. 3. There was a significant difference in distortion rate between the oposite teeth. 4. Cervical portion of the tooth had more decreased rate of horizontal distortion than apical portion.

  • PDF

Body Image Distortion among Inpatients with Schizophrenia (입원한 조현병 환자의 신체이미지 왜곡)

  • Kim, Sung-Jin;Moon, Seok-Woo;Kim, Daeho
    • Korean Journal of Biological Psychiatry
    • /
    • v.19 no.4
    • /
    • pp.211-218
    • /
    • 2012
  • Objectives Body image distortion is found in eating disorder and obesity and there are some evidence that schizophrenia is associated with body image distortion. This study sought to find whether schizophrenic patients report more body image distortion than healthy individuals and whether it is related with symptomatology. Methods A total of 88 inpatients with schizophrenia and 88 healthy controls were recruited. Weight, height, and body image accuracy were assessed in all participants, and assessment of mood, psychotic symptom severity and self-esteem, and personal and social performance scale were conducted. Results The patients with schizophrenia had higher Body Mass Index (p < 0. 001) and underestimated their body size more than controls (26.14% vs. 5.13%, p < 0.001). Multiple regression analysis showed that lower depressive symptoms and higher scores of general psychopathology predicted underestimation of body size. Conclusion Weight gain and metabolic syndrome are common adverse events of pharmacological treatment of schizophrenia. Thus, underestimation of body size among patients with schizophrenia may interfere with effort to lose weight or seek weight reduction programs. Clinicians need to consider possible unterestimation of underestimation of body size in patients whose general symptomatology is severe.