• 제목/요약/키워드: Low-voltage Distribution System

검색결과 201건 처리시간 0.026초

함정용 다기능 AESA 레이더 시스템을 위한 고전압·고효율 DC-DC 전원모듈 개발 (Development of High Voltage, High Efficiency DC-DC Power Module for Modern Shipboard Multi-Function AESA Radar Systems)

  • 정민길;이원영;김상근;김수태;권영수
    • 한국군사과학기술학회지
    • /
    • 제24권1호
    • /
    • pp.50-60
    • /
    • 2021
  • For conventional AESA radars, DC-DC power modules using 300 Vdc have low efficiency, high volume, heavy weight, and high price, which have problems in modularity with T/R module groups. In this paper, to improve these problems, we propose a distributed DC-DC power module with high-voltage 800 Vdc and high-efficiency Step-down Converter. In particular, power requirements for modern and future marine weapons systems and sensors are rapidly evolving into high-energy and high-voltage power systems. The power distribution of the next generation Navy AESA radar antenna is under development with 1000 Vdc. In this paper, the proposed highvoltage, high-efficiency DC-DC power modules increase space(size), weight, power and cooling(SWaP-C) margins, reduce integration costs/risk, and reduce maintenance costs. Reduced system weight and higher reliability are achieved in navy and ground AESA systems. In addition, the proposed architecture will be easier to scale with larger shipboard radars and applicable to other platforms.

고조파 전류원에 의한 콘덴서 임피던스 특성 해석 (Analysis of Impedance Performance for Condenser by Harmonic Current Source)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

배전계통의 순간전압 상승에 따른 SPD 고압 TOV 시험설비 구축 (Temporary Over Voltage Test System for Surge Protective Device in Low Distribution system)

  • 김용성;김언석;안건현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1391_1392
    • /
    • 2009
  • 본 논문에서는 저압 서지보호기의 안전성평가를 위한 고압 계통 고장에 의한 순간 과전압시험 설비를 IEC 61643-1의 따라 구축 하였고, 구축된 시험설비의 성능을 분석하였다. 고압 계통의 순간 과전압시험 기준은 가장 일반적인 미국전력 계통의 기준인 3상 4선식이 반영이 되었으며 전압의 크기는 AC 1200V이다. 본 논문에서는 순간과전압이 상과 접지사이의 개방전압 AC 1200V을 약 200ms 동안 인가되는지를 측정하였고, 단락전류가 AC 300A이상을 측정하였다.

  • PDF

고장계산 및 보호협조 판정 소프트웨어 개발 (A Development of Software about Short-circuit Calculation and Protective-coordination)

  • 박성찬;최장흠;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.159-162
    • /
    • 2002
  • A software, called touch-one, is developed about the determination of short-circuit values and protective co-ordination in power system. The used solution algorithm reviewed intensively, and the protective co-ordination determination technique presented by using the circuit-breaker's current-limitation characteristic. The protective coordination concerns the behaviour of two devices placed in series in an electrical network, with a short-circuit downstream circuit-breaker. It has two basic principles: First, discrimination which is an increasing requirement of low voltage electrical distribution systems. Second, which is less well known: cascading, which consists of installing a device, whose breaking capacity is less than the three-phase short-circuit current at its terminals and helped by main circuit-breaker. With this software, we can construct a electric-power system which is reliable and economic according to user's purpose.

  • PDF

점화코일용 에폭시의 부분방전 특성 (Partial Discharge Characteristics of Epoxy for Ignition Coil)

  • 신종열;홍진웅
    • 한국안전학회지
    • /
    • 제19권4호
    • /
    • pp.141-149
    • /
    • 2004
  • 가솔린 엔진을 장착한 자동차는 고전압발생장치인 점화코일을 이용하여 고전압을 발생 연소실 내의 혼합기를 점화 및 연소시킴으로써 동력을 얻고 엔진을 구동하게 된다. 점화코일은 1차측 낮은 전압을 스위칭 작용으로 2차측 높은 전압을 발생시키고, 이를 전극으로 보내는데, 점화코일에 작은 결함이 발생하게 되면 제 성능을 발휘하지 못한다. 본 연구에서는 현재 사용하고 있는 에폭시 성형 점화코일과 절연재료인 에폭시수지를 시료로 선택하여 시료에 전압이 인가될 때 발생하는 부분방전 특성을 측정하여 전압변화에 따른 위상각, 방전전하량 및 발생빈도 수 등의 분포를 연구하고 검토한 결과를 실제 자동차점화장치에 접목시켜 점화코일의 성능향상과 전기장치의 신뢰성 확보에 기여하고자 한다.

접지규정 IEC 60364의 국내 적용을 위한 실증시험장 구축 (Test field for the application of IEC 60364 in Korea)

  • 남기영;최상봉;류희석;이재덕;정성환;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.116-118
    • /
    • 2005
  • IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standards deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries defines the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for themselves. The background of circuit of IEC 60364 is based on the ungrounded system as most of European countries adopt. However, since domestic ground system is multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364 and to evaluate the standard is applicable or not to domestic rule for the protection against ground fault through the related test.

  • PDF

새로운 액티브 전압 클램프 ZVS-PWM 공진 고주파 인버터 (The New Active Voltage Clamp ZVS-PWM Resonant High-frequency Inverter)

  • 안용위;김홍신;문상필;우경일;박한석
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.188-193
    • /
    • 2017
  • In this paper, a ZVS-PWM high-frequency inverter with a PWM control function is applied to commercial system 220[Vrms], and a resonator type ZVS-PWM high-frequency inverter circuit with a fixed-two methods were proposed. The parameters of the transformer model equivalent circuit of a copier fixing device, which is an essential element in the parameter optimization of the proposed circuit, are obtained by using a high-frequency amplifier and its frequency characteristics are described. The proposed method compared to the existing single-ended ZVS-PFM high frequency inverter can suppress the voltage and current peak value of the power semiconductor switching device and reduce the switching loss. The efficiency of the proposed method itself is 98[%] at rated power output. Also, the efficiency of 96[%] can be obtained even at low output, so that the proposed high frequency inverter is very efficient inverter. The total efficiency from the commercial AC input to the inverter output is 93[%] at rated, which is considered efficient for use in copying machines. In addition, the diode bridge loss accounts for the largest portion of the overall system efficiency distribution. On the other hand, the nonparallel filter has a very low loss.

ECR-PECVD 장치의 제작과 특성 (Manufacturing and characterization of ECR-PECVD system)

  • 손영호;정우철;정재인;박노길;황도원;김인수;배인호
    • 한국진공학회지
    • /
    • 제9권1호
    • /
    • pp.7-15
    • /
    • 2000
  • An ECR-PECVD system with the characteristics of high ionization rat다 ability of plasma processing in a wide pressure range and deposition at low temperature was manufactured and characterized for the deposition of thin films. The system consists of a vacuum chamber, sample stage, vacuum gauge, vacuum pump, gas injection part, vacuum sealing valve, ECR source and a control part. The control of system is carried out by the microprocessor and the ROM program. We have investigated the vacuum characteristics of ECR-PECVD system, and also have diagnosed the characteristics of ECR microwave plasma by using the Langmuir probe. From the data of system and plasma characterization, we could confirmed the stability of pressure in the vacuum chamber according to the variation of gas flow rate and the effect of ion bombardment by the negative DC self bias voltage. The plasma density was increased with the increase of gas flow rate and ECR power. On the other hand, it was decreased with the increase of horizontal radius and distance between ECR source and probe. The calculated plasma densities were in the range of 49.7\times10^{11}\sim3.7\times10^{12}\textrm{cm}^{-3}$. It is also expected that we can estimate the thickness uniformity of film fabricated by the ECR-PECVD system from the distribution of the plasma density.

  • PDF

On the Design of Power Supply System for Freight Train Reefer Container Based on Simulation

  • Kim, Joouk;Hwang, Sunwoo;Lee, Jae-Bum;Hwang, Jaemin;Chae, Uri
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권3호
    • /
    • pp.249-257
    • /
    • 2022
  • In recent years, if we order food by easily accessing the online market with our smartphone, we can receive the product in a fresh state at dawn the next day. Cold chain is an industry that can create high added value because it has both the characteristics of general logistics and sensitivity to temperature. Based on the electrical specifications derived from the reefer container capacity requirement investigation, we proved that power supply to up to 33 reefer containers can be made by using three additional auxiliary power supplies which are applied for freight trains in Korea. In this paper, we conducted a research on a design of power supply system for freight train reefer container based on simulation as a basic research necessary for low-temperature distribution and cold chain construction based on the reefer container railroad. Consequently, the simulation was conducted using the three-phase inverter diagram in PSIM and the SVPWM (3-harmonic injection method) control technique, and it was verified that the required power voltage was satisfied with 622Vdc, which is lower than the input voltage of general SPWM of 718Vdc. The details of this paper could be used as a foundational study for constructing cold chains based on a reefer container dedicated to freight trains in the future.

유도발전기 역률 보상 콘덴서와 직렬 리액터의 동작 분석 (Operating Analysis of Power Factor Compensation Condenser and Series Reactor in the Induction Generator)

  • 김종겸;박영진
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.593-598
    • /
    • 2017
  • Induction generator is always required reactive power in order to generate a rotating magnetic field as an inductive load. The reactive power must be continuously supplied to the induction generator as well as load of distribution system from the power supply side. So the power factor of the power supply side during the induction generation operation is low. Condenser is installed in order to raise the low power factor of the induction generator. Switching transients occurs when the power supply of the capacitor is turned on in order to ensure the low power factor. When using the reactor in series with the capacitor in order to reduce the influence of switching transient, it can affect the reactive power by the condenser voltage rises. In this study, we analyzed the operating characteristics for power and power factor of induction generator in accordance with the presence or absence of the application of the serial reactors for switching transients reduction of the condenser and the condenser for power factor correction.