• 제목/요약/키워드: Low-profile visualized intraluminal support

검색결과 2건 처리시간 0.016초

Evaluation of Stent Apposition in the LVIS Blue Stent-Assisted Coiling of Distal Internal Carotid Artery Aneurysms : Correlation with Clinical and Angiographic Outcomes

  • Kwon, Min-Yong;Ko, Young San;Kwon, Sae Min;Kim, Chang-Hyun;Lee, Chang-Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권6호
    • /
    • pp.801-815
    • /
    • 2022
  • Objective : To evaluate the stent apposition of a low-profile visualized intraluminal support (LVIS) device in distal internal carotid artery (ICA) aneurysms, examine its correlation with clinical and angiographic outcomes, and determine the predictive factors of ischemic adverse events (IAEs) related to stent-assisted coiling. Methods : We retrospectively analyzed a prospectively maintained database of 183 patients between January 2017 and February 2020. The carotid siphon from the cavernous ICA to the ICA terminus was divided into posterior, anterior, and superior bends. The anterior bends were categorized into angled (V) and non-angled (C, U, and S) types depending on the morphology and measured angles. Complete stent apposition (CSA) and incomplete stent apposition (ISA) were evaluated using unsubtracted angiography and flat-panel detector computed tomography. Dual antiplatelet therapy with aspirin 200 mg and clopidogrel 75 mg was administered. Clopidogrel resistance was defined as fewer responders (≥10%, <40%) and non-responders (<10%) based on the percent inhibition (%INH) of the VerifyNow system. These were counteracted by a dose escalation to 150 mg for fewer responders or substitution with cilostazol 200 mg for non-responders. IAEs included intraoperative in-stent thrombosis, transient ischemic attack, cerebral infarction, and delayed in-stent stenosis. A multivariate logistic regression analysis was used to determine the predictive factors for ISA and IAEs. Results : There were 33 ISAs (18.0%) and 27 IAEs (14.8%). The anterior bend angle was narrower in ISA (-4.16°±25.18°) than in CSA (23.52°±23.13°) (p<0.001). The V- and S-types were independently correlated with the ISA (p<0.001). However, treatment outcomes, including IAEs (15.3% vs. 12.1%), aneurysmal complete occlusion (91.3% vs. 88.6%), and recanalization (none of them), did not differ between CSA and ISA (p>0.05). The %INH of 27 IAEs (13.78%±14.78%) was significantly lower than that of 156 non-IAEs (26.82%±20.23%) (p<0.001). Non-responders to clopidogrel were the only significant predictive factor for IAEs (p=0.001). Conclusion : The angled and tortuous anatomical peculiarity of the carotid siphon caused ISA of the LVIS device; however, it did not affect clinical and angiographic outcomes, while the non-responders to clopidogrel affected the IAEs related to stent-assisted coiling.

Overlapping Stents-Assisted Coiling for Vertebral Artery Dissecting Aneurysm : LVIS Stent within Neuroform EZ Stent

  • Liu, Xing-Long;Wang, Bin;Zhao, Lin-Bo;Jia, Zhen-Yu;Shi, Hai-Bin;Liu, Sheng
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권4호
    • /
    • pp.523-530
    • /
    • 2022
  • Objective : To evaluate the safety and efficacy of an overlapped stenting-assisted coiling technique in treating vertebral artery dissecting aneurysm (VADA) via Low-profile Visualized Intraluminal Support (LVIS) stent-within-Neuroform EZ stent. Methods : From January 2017 to June 2019, 18 consecutive patients with VADAs (ruptured : unruptured=5 : 13) were treated with the overlapping stents assisted-coiling technique in our center. The overlapping manner was a Neuroform EZ stent being deployed first, followed by LVIS stents placement using the 'shelf' technique. The patients' clinical characteristics, technical feasibility and safety, and immediate and follow-up angiographic results were retrospectively reviewed. Results : Seventeen (94.4%) procedures were technically successful with an exact deployment of the stents and patent parent or perforator arteries. The immediate angiographies after procedure confirmed Raymond class I, II, and III occlusion of VADAs were in 12 (66.7%), two (11.1%), and four cases (22.2%), respectively. Post-procedural complications developed in one patient (5.6%) with minor brainstem infarctions, which resulted from an in-stent thrombosis during the procedure. Angiographic follow-up at 5.7 months (range 3 to 9 months) demonstrated Raymond class I and II occlusion were in all cases (100%). The modified Rankin Scale scores at 21.3 months (range 15 to 42 months) 0-2 in 17 cases (94.4%) and three in one case (5.6%). Conclusion : Overlapping stents via LVIS stent-within-Neuroform EZ stent combined with coiling is safe and effective for patients with VADA in the midterm results.