DOI QR코드

DOI QR Code

Overlapping Stents-Assisted Coiling for Vertebral Artery Dissecting Aneurysm : LVIS Stent within Neuroform EZ Stent

  • Liu, Xing-Long (Department of Interventional Radiology, the First Affiliated Hospital of Nanjing Medical University) ;
  • Wang, Bin (Department of Interventional Radiology, the First Affiliated Hospital of Nanjing Medical University) ;
  • Zhao, Lin-Bo (Department of Interventional Radiology, the First Affiliated Hospital of Nanjing Medical University) ;
  • Jia, Zhen-Yu (Department of Interventional Radiology, the First Affiliated Hospital of Nanjing Medical University) ;
  • Shi, Hai-Bin (Department of Interventional Radiology, the First Affiliated Hospital of Nanjing Medical University) ;
  • Liu, Sheng (Department of Interventional Radiology, the First Affiliated Hospital of Nanjing Medical University)
  • Received : 2021.11.18
  • Accepted : 2022.02.03
  • Published : 2022.07.01

Abstract

Objective : To evaluate the safety and efficacy of an overlapped stenting-assisted coiling technique in treating vertebral artery dissecting aneurysm (VADA) via Low-profile Visualized Intraluminal Support (LVIS) stent-within-Neuroform EZ stent. Methods : From January 2017 to June 2019, 18 consecutive patients with VADAs (ruptured : unruptured=5 : 13) were treated with the overlapping stents assisted-coiling technique in our center. The overlapping manner was a Neuroform EZ stent being deployed first, followed by LVIS stents placement using the 'shelf' technique. The patients' clinical characteristics, technical feasibility and safety, and immediate and follow-up angiographic results were retrospectively reviewed. Results : Seventeen (94.4%) procedures were technically successful with an exact deployment of the stents and patent parent or perforator arteries. The immediate angiographies after procedure confirmed Raymond class I, II, and III occlusion of VADAs were in 12 (66.7%), two (11.1%), and four cases (22.2%), respectively. Post-procedural complications developed in one patient (5.6%) with minor brainstem infarctions, which resulted from an in-stent thrombosis during the procedure. Angiographic follow-up at 5.7 months (range 3 to 9 months) demonstrated Raymond class I and II occlusion were in all cases (100%). The modified Rankin Scale scores at 21.3 months (range 15 to 42 months) 0-2 in 17 cases (94.4%) and three in one case (5.6%). Conclusion : Overlapping stents via LVIS stent-within-Neuroform EZ stent combined with coiling is safe and effective for patients with VADA in the midterm results.

Keywords

References

  1. Ansari SA, Kuhn AL, Honarmand AR, Khan M, Hurley MC, Potts MB, et al. : Emergent endovascular management of long-segment and flow-limiting carotid artery dissections in acute ischemic stroke intervention with multiple tandem stents. AJNR Am J Neuroradiol 38 : 97-104, 2017 https://doi.org/10.3174/ajnr.A4965
  2. Chang R, Wu J, Zhang X, Ye Y, Zhou W, Liu Y : Analysis of the reactivity of aspirin and clopidogrel and its influencing factors in patients with coronary heart disease at high altitude. Evid Based Complement Alternat Med 2021 : 2849982, 2021
  3. Cho SH, Jo WI, Jo YE, Yang KH, Park JC, Lee DH : Bench-top comparison of physical properties of 4 commercially-available self-expanding intracranial stents. Neurointervention 12 : 31-39, 2017 https://doi.org/10.5469/neuroint.2017.12.1.31
  4. Chung J, Kim BM, Lim YC : Five overlapping enterprise stents in the internal carotid artery-to-middle cerebral artery to treat a ruptured blood blister-like aneurysm. Neurol Sci 34 : 1485-1487, 2013 https://doi.org/10.1007/s10072-012-1231-6
  5. Chung Y, Lee SH, Choi SK, Kim BJ, Lee KM, Kim EJ : Triple stent therapy for the treatment of vertebral dissecting aneurysms: efficacy and safety. World Neurosurg 99 : 79-88, 2017 https://doi.org/10.1016/j.wneu.2016.11.118
  6. Gaughen JR Jr, Hasan D, Dumont AS, Jensen ME, McKenzie J, Evans AJ : The efficacy of endovascular stenting in the treatment of supraclinoid internal carotid artery blister aneurysms using a stent-in-stent technique. AJNR Am J Neuroradiol 31 : 1132-1138, 2010 https://doi.org/10.3174/ajnr.A2016
  7. Ge H, Lv X, Yang X, He H, Jin H, Li Y : LVIS stent versus enterprise stent for the treatment of unruptured intracranial aneurysms. World Neurosurg 91 : 365-370, 2016 https://doi.org/10.1016/j.wneu.2016.04.057
  8. Griessenauer CJ, Ogilvy CS, Adeeb N, Dmytriw AA, Foreman PM, Shallwani H, et al. : Pipeline embolization of posterior circulation aneurysms: a multicenter study of 131 aneurysms. J Neurosurg 130 : 923-935, 2018 https://doi.org/10.3171/2017.9.jns171376
  9. Jeon P, Kim BM, Kim DI, Park SI, Kim KH, Kim DJ, et al. : Reconstructive endovascular treatment of fusiform or ultrawide-neck circumferential aneurysms with multiple overlapping enterprise stents and coiling. AJNR Am J Neuroradiol 33 : 965-971, 2012 https://doi.org/10.3174/ajnr.A2857
  10. Jin SC, Kwon DH, Choi CG, Ahn JS, Kwun BD : Endovascular strategies for vertebrobasilar dissecting aneurysms. AJNR Am J Neuroradiol 30 : 1518-1523, 2009 https://doi.org/10.3174/ajnr.A1621
  11. Kim BM, Shin YS, Kim SH, Suh SH, Ihn YK, Kim DI, et al. : Incidence and risk factors of recurrence after endovascular treatment of intracranial vertebrobasilar dissecting aneurysms. Stroke 42 : 2425-2430, 2011 https://doi.org/10.1161/strokeaha.111.617381
  12. Kim CH, Lee CH, Kim YH, Sung SK, Son DW, Lee SW, et al. : Flow diverter devices for the treatment of unruptured vertebral artery dissecting aneurysm. J Korean Neurosurg Soc 64 : 891-900, 2021 https://doi.org/10.3340/jkns.2021.0181
  13. Krischek O, Miloslavski E, Fischer S, Shrivastava S, Henkes H : A comparison of functional and physical properties of self-expanding intracranial stents [Neuroform3, Wingspan, Solitaire, Leo+, Enterprise]. Minim Invasive Neurosurg 54 : 21-28, 2011 https://doi.org/10.1055/s-0031-1271681
  14. Kuhn AL, Kan P, Massari F, Lozano JD, Hou SY, Howk M, et al. : Endovascular reconstruction of unruptured intradural vertebral artery dissecting aneurysms with the Pipeline embolization device. J Neurointerv Surg 8 : 1048-1051, 2016 https://doi.org/10.1136/neurintsurg-2015-012028
  15. Lim YC, Shin YS, Chung J : Flow diversion via LVIS blue stent within enterprise stent in patients with vertebral artery dissecting aneurysm. World Neurosurg 117 : 203-207, 2018 https://doi.org/10.1016/j.wneu.2018.06.029
  16. Lv X, Yang H, Liu P, Li Y : Flow-diverter devices in the treatment of intracranial aneurysms: a meta-analysis and systematic review. Neuroradiol J 29 : 66-71, 2016 https://doi.org/10.1177/1971400915621321
  17. Molyneux AJ, Birks J, Clarke A, Sneade M, Kerr RS : The durability of endovascular coiling versus neurosurgical clipping of ruptured cerebral aneurysms: 18 year follow-up of the UK cohort of the international subarachnoid aneurysm trial (ISAT). Lancet 385 : 691-697, 2015 https://doi.org/10.1016/S0140-6736(14)60975-2
  18. Roy D, Milot G, Raymond J : Endovascular treatment of unruptured aneurysms. Stroke 32 : 1998-2004, 2001 https://doi.org/10.1161/hs0901.095600
  19. Santos-Franco JA, Zenteno M, Lee A : Dissecting aneurysms of the vertebrobasilar system. A comprehensive review on natural history and treatment options. Neurosurg Rev 31 : 131-140, 2008 https://doi.org/10.1007/s10143-008-0124-x
  20. Song Y, Wang Y, Li C, Wang Y, Mu S, Yang X : Retreatment and outcomes of recurrent intracranial vertebral artery dissecting aneurysms after stent assisted coiling: a single center experience. PLoS One 9 : e113027, 2014 https://doi.org/10.1371/journal.pone.0113027
  21. Walsh KM, Moskowitz SI, Hui FK, Spiotta AM : Multiple overlapping stents as monotherapy in the treatment of 'blister' pseudoaneurysms arising from the supraclinoid internal carotid artery: a single institution series and review of the literature. J Neurointerv Surg 6 : 184-194, 2014 https://doi.org/10.1136/neurintsurg-2013-010648
  22. Wang CC, Fang YB, Zhang P, Zhu X, Hong B, Xu Y, et al. : Reconstructive endovascular treatment of vertebral artery dissecting aneurysms with the low-profile visualized intraluminal support (LVIS) device. PLoS One 12 : e0180079, 2017 https://doi.org/10.1371/journal.pone.0180079
  23. Won YS, Rho MH, Chung EC, Hong HP, Kim SY, Park HJ, et al. : Multiple overlapping stent-assisted coiling of complex aneurysms: a single-center experience. Neurol Res 37 : 189-196, 2015 https://doi.org/10.1179/1743132814Y.0000000444
  24. Zhao KJ, Zhao R, Huang QH, Xu Y, Hong B, Fang YB, et al. : The interaction between stent(s) implantation, PICA involvement, and immediate occlusion degree affect symptomatic intracranial spontaneous vertebral artery dissection aneurysm (sis-VADA) recurrence after reconstructive treatment with stent(s)-assisted coiling. Eur Radiol 24 : 2088-2096, 2014 https://doi.org/10.1007/s00330-014-3225-7
  25. Zhu D, Fang Y, Yang P, Zhang P, Chen L, Xu Y, et al. : Overlapped stenting combined with coiling for blood blister-like aneurysms: comparison of low-profile visualized intraluminal support (LVIS) stent and non-LVIS stent. World Neurosurg 104 : 729-735, 2017 https://doi.org/10.1016/j.wneu.2017.03.092