• 제목/요약/키워드: Low-pressure membrane

검색결과 235건 처리시간 0.03초

Production of High Purity Oxygen by Conbination of Membrane and PSA Methods

  • Hwang, Sun-Tak
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1994년도 심포지움시리즈 Jan-94 기체분리막 기술 및 응용
    • /
    • pp.1-21
    • /
    • 1994
  • There are growing needs to produce relatively high purity (99.0% or higher) oxygen at low cost. For small scale production, both pressure swing adsorption (PSA) and membrane process are competitve and less expensive or more convient than well known crygenic fractionation technology. A continuous membrane colume (CMC) combined with a PSA oxygen generator can be employed to produce high purity oxygen continuosly. The oxygen-enriched gas generated by a PSA unit, with a concentration of 93-94%, is fed to the CMC that consists of three modules of poly(imide) hollow fibers. Several experiments were conducted by varying parameters, such feed flow rate, transmenbrane pressure drop, stage cut, and feed location in order to obtain a high oxygen concentration above 99.0%. A two-series unit mode was also employed with CMC operation to optimize the given membrane area.

  • PDF

국산 막형 산화기 (OXYREX)의 체외순환 임상 성적 - 개심수술 40례 적용 - (Clinical Application of OXYREX Hollow Fiber Membrane Oxygenator)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • 제23권6호
    • /
    • pp.1049-1056
    • /
    • 1990
  • The OXYREX hollow fiber membrane oxygenator developed by joint work of KIST and Green Cross Medical company has been evaluated by experimental investigation and clinical application, In this oxygenator gas exchanges occur through small pores of 0.1pm size which are distributed on 70% of surface of polypropylene hollow fiber. The Oxyrex membrane oxygenator consists of 36 thousand hollow fibers and it has 3.3m2 of gas exchange surface. The Oxyrex membrane oxygenator has unique blood flow path: blood enters the oxygenator passes between the hollow fibers and exits through outlet ports, that provides low transmembrane pressure drop. In the animal experiment and in vitro investigations of Oxyrex oxygenator, it showed low transmembrane pressure difference, effective heat exchanger performance, stable gas transfer function and less blood trauma. The Oxyrex oxygenator been used from March, 1990, to October, 1990, in 40 patients undergoing open heart operations. In the clinical applications of Oxyrex, adequate oxygenation[PaO2, 283$\pm$70mmHg] and carbon dioxide removal[PaCO2, 27\ulcorner6mmHg]were maintained under the condition of FiO2: below 0.6, Hct; 25%, perfusion flow; 2.4 L/min, gas flow: 2.1 L/min. During maximum 365 minutes of cardiopulmonary bypass[CPB] time period, the Oxyrex oxygenator maintained stable condition of PaO2, PaCO2 respectively and it also kept low plasma hemoglobin level. The complement proteins C3 and CH50 were not significantly changed pre to post CPB. There were no complications related to the oxygenator during and after the CPB.

  • PDF

외부흐름 중공사 막형 인공폐의 액체흐름과 압력손실 (Liquid Flow and Pressure Drop of an Outside Flow Membrane Oxygenator with Hollow Fibers)

  • 이삼철;김기범
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권1호
    • /
    • pp.27-32
    • /
    • 2002
  • 본 연구에서는 혈관내 혈액 흐름의 압력손실을 최소화하여야 하는 제한 인자를 만족하는 새로운 막형 인공폐에서 액체흐름경향과 중공사 개수에 대한 압력손실 영향을 고찰하고자 하였다 막형 인공폐는 380 $\mu m$의 중공사 외경과 600 mm의 축 방향 길이를 갖는 수 백 개의 중공사로 이루어진 다발이다 중공사 다발은 8가지로 변화시켰으며 흐름은 펌프를 이용하여 조절하였다 혈액대용물질로 글리세롤 용액과 물을 사용하여 압력손실을 측정하였으며 동일한 흐름 경향을 각 중공사들에서 얻었다. 700개의 중공사로 이루어진 막형 인공 폐의 외부 압력손실은 13-16 mmHg이었으며 중공사 개수의 감소에 따른 마찰계수는 중공사와 액체와의 효과적인 접촉이 일어나므로 증가되었다.

친수화 고분자 소재를 이용한 저압용 PVDF 나노복합중공사막의 제조 및 성능 연구 (Preparation and Performance of Low Pressure PVDF Nano-composite Hollow Fiber Membrane Using Hydrophilic Polymer)

  • 박철오;임지원
    • 멤브레인
    • /
    • 제28권5호
    • /
    • pp.361-367
    • /
    • 2018
  • 본 연구에서는 polyvinylidene fluoride (PVDF) 중공사막을 지지체로 한 저압용 나노복합막을 제조하였다. Poly styrene sulfonic acid (PSSA)와 polyethyleneimine (PEI)을 layer-by-layer 및 염석 효과 방식으로 지지체막에 코팅하였다. 막의 투과도와 염 배제율 성능을 알아보고자 NaCl, $MgCl_2$, $CaSO_4$ 100 mg/L수용액을 1 L/min의 유량으로, 2 bar의 압력을 상온에서 가해주었다. 20,000 ppm의 PSSA (이온세기 1.0)용액에 3분, 30,000 ppm (이온세기 0.1)용액에 1분 코팅한 막이 가장 우수하였다. 투과도와 염 배제율은 NaCl 공급액에서는 38.5 LMH, 57.1%, $MgCl_2$는 37.9 LMH, 90.2%, $CaSO_4$는 32.4 LMH, 54.6%로 각각 측정되었다.

가압형 정삼투 시 압력에 따른 정삼투막의 Structure Parameter 변화양상 예측 (Structure Parameter Change Estimation of a Forward Osmosis Membrane Under Pressurized Conditions in Pressure-assisted Forward Osmosis (PAFO))

  • 국승호;김성조;이진우;황문현;김인수
    • 멤브레인
    • /
    • 제26권3호
    • /
    • pp.187-196
    • /
    • 2016
  • 최근 정삼투(FO) 공정의 성능향상을 위해 유입수에 낮은 수압을 가하는 가압형 정삼투(PAFO) 공정이 관심을 받고 있다. Structure parameter는 FO 및 PAFO 공정 운전시 유도용질의 확산 저항성(Solute resistivity)을 결정하며, 이는 Solution-diffusion model (S-D model)을 통한 수투과 및 염투과 성능 예측을 지배하는 인자 중에 하나이다. 본 연구는 S-D model을 이용하여 가압형 정삼투시 유입수 측에 가해지는 압력에 따른 Structure parameter 변화 양상을 예측하고자 하였다.

고분자 전해질 연료전지의 전해질 막내의 함수율과 성능 예측 (Prediction of Fuel Cell Performance and Water Content in the Membrane of a Proton Exchange Membrane Fuel Cell)

  • 양장식;최경민;김덕줄
    • 한국자동차공학회논문집
    • /
    • 제14권6호
    • /
    • pp.151-159
    • /
    • 2006
  • A one-dimensional numerical analysis is carried out to investigate the effects of inlet gas humidities, inlet gas pressures, and thicknesses of membrane on the performance of a proton exchange membrane fuel cell. It is found that the relative humidity of inlet gases at anode and cathode sides has a significant effect on the fuel cell performance. Especially, the desirable fuel cell performance occurs at low relative humidity of the cathode side and at high humidity of the anode side. In addition, an increase in the pressure ranging from 1 atm to 4 atm at the cathode side results in a significant improvement in the fuel cell performance due to the convection effect by a pressure gradient toward the anode side, and with decreasing the thickness of membrane, the fuel cell performance is enhanced reasonably.

고온 롤 라미네이터용 멤브레인 구조 필름형 압력 센서 개발 (Development of Membrane Film Pressure Sensor for Hot Roll Laminator)

  • 김도연;이태경;강필식
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.1059-1065
    • /
    • 2020
  • Demand for pressure sensors is increasing in various fields such as machinery, healthcare and medical care. A recent study is being conducted to create sensors that are more sensitive and have longer linear sections based on measurement principles. In this paper, a film-type sensor with a membrane structure was developed to measure the pressure distributed in the axial direction of a hot roll laminator. Performance of sensors was evaluated by resistance and durability according to membrane diameter. The resistance of the membrane sensor varies according to the contact state and contact area of the electrode. Therefore, the membrane diameter selection is important. Experiments showed the most pronounced variation in resistance under pressure at 8 mm in diameter of membrane. Reliability evaluation of sensors was carried out at room temperature and high temperature. The pressure on the sensor was pressurized 1000 times to measure the initial resistance and the resistance after the evaluation to analyze the change. Sensors showed stable results with low resistance changes of 5.15% and 6.27%, respectively. A large area sensor manufactured using the developed sensor also showed reliable results.

Ultrafiltration membranes for drinking-water production from low-quality surface water: A case study in Spain

  • Rojas-Serrano, Fatima;Alvarez-Arroyo, Rocio;Perez, Jorge I.;Plaza, Fidel;Garralon, Gloria;Gomez, Miguel A.
    • Membrane and Water Treatment
    • /
    • 제6권1호
    • /
    • pp.77-94
    • /
    • 2015
  • Ultrafiltration membranes have several advantages over conventional drinking-water treatment. However, this technology presents major limitations, such as irreversible fouling and low removal of natural organic matter. Fouling depends heavily on the raw-water quality as well as on the operating conditions of the process, including flux, permeate recovery, pre-treatment, chemical cleaning, and backwashing. Starting with the premise that the optimisation of operating variables can improve membrane performance, different experiments were conducted in a pilot plant located in Granada (Spain). Several combinations of permeate and backwashing flow rates, backwashing frequencies, and aeration flow rates were tested for low-quality water coming from Genil River with the following results: the effluent quality did not depend on the combination of operating conditions chosen; and the membrane was effective for the removal of microorganisms, turbidity and suspended solids but the yields for the removal of dissolved organic carbon were extremely low. In addition, the threshold transmembrane pressure (-0.7 bar) was reached within a few hours and it was difficult to recover due to the low efficiency of the chemical cleanings. Moreover, greater transmembrane pressure due to fouling also increased the energy consumption, and it was not possible to lower it without compromising the permeate recovery. Finally, the intensification of aeration contributed positively to lengthening the operation times but again raised energy consumption. In light of these findings, the feasibility of ultrafiltration as a single treatment is questioned for low-quality influents.

A Novel Technoque for Characterization of Membranes

  • Webber, Ronald;Jena, Akshaya;Gupta, Krishna
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2001년도 제14회 심포지엄 : 제2회 분리막 표준화(The 2nd Standardization of Membranes)
    • /
    • pp.39-50
    • /
    • 2001
  • The performance of membranes is governed their pore struture. Pore structures of porous materials can be determined by a number of techniques. However, The novel technique, capillary folw porometry has a number of advantages. In this technique, the sample is brought in contact with a liquid that fills the pores in the membrane spontaneously. Gas under pressure is used to force the liquid from the pores and increase gas flow. Gas flow rate measured as a function of gas pressure in wet and dry samples yield data on the largest pore size, the mean flow pore size, flow distribution and permeability. Pore characteristics of a number of membranes were measured using this technique. This technique did not require the use of any toxic material and the pressure employed was low. Capillary flow porometry is a suitable technique for measurement of the pore structure of many membranes.

  • PDF

PRO 분리막 및 모듈성능에 지지체가 미치는 영향 (The effect of backing layer for pro membranes and modules)

  • 한만재;전은주;심연주;이종화
    • 상하수도학회지
    • /
    • 제30권5호
    • /
    • pp.553-559
    • /
    • 2016
  • There has been increasing global interest in the environmental pollution problems produced by fossil fuel consumption and greenhouse gas emissions. In order to tackle these issues, new renewable energy such as solar, wind, bio gas, fuel cell and pressure retarded osmosis(PRO) have been developed extensively. Among these energy sources, PRO is one of the salinity gradient power generation methods. In PRO, energy is obtained by the osmotic pressure generated from the concentration difference between high and low concentration solutions separated by a semipermeable membrane. The development for high power density PRO membranes is imperative with the purpose of commercialization. This study investigates development of thin film composite PRO membrane and spiral wound module for high power density. Also, the influence of membrane backing layer on power density was identified, and the characteristic factors of PRO membranes was determined. Different backing layers were used to improve power density. As expected, the PRO membrane with more porous backing layer showed higher power density.