• Title/Summary/Keyword: Low-floor

Search Result 694, Processing Time 0.029 seconds

The Kinematic Analysis on The Stand Long Jump of Visually Impaired Persons (시각장애인의 제자리멀리뛰기 동작에 대한 운동학적 분석)

  • Oh, Cheong-Hwan;Choi, Jung-Kyu;Jeong, Ik-Su;Lee, Dong-Gin;Choi, Su-Nam;Nam, Taek-Gil
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.39-47
    • /
    • 2006
  • This study long jump action to each situation on a chessboard and section of sight disabled person and normal person through third dimension reflex analysis mechanical special quality because do comparative analysis sight disabled person's exercise ability and technology structure of action that run understand. As can do better without danger of injury map and training of exercise item that action that run is included, do offer of pabulum by purpose. Through this study, conclusion is as following. 1. Sight disabled persons' long jump average recording (121.84cm) showing normal persons' average recording (259.27cm) and much differences, show that motion of body is not big to Touch-down from Ready action. 2. Each phase body center composition(r) average speed displayed result that it is more meaning more than Each phase time required. 3. Began in line carriage without body back stretching in 1 situation on Event one are sight disabled persons. Was expose that do not bend enough knee and ankle than normal person in Event two. Was expose that body is not drooped for surface of land in Event three, and knee and ankle were expose that do not unfold easily than normal person. Was expose that do not bend enough on Touch-down knee by relation that can not grasp position of the floor in Event four. 4. When taking off, the average of horizontal speed of body center are 1.80m/sec for blind people and 3.53m/sec for the normal. In this connection, the study shows that the difference of horizontal speed between the blind and the normal is bigger than difference of vertical speed, which are 1.56m/sec for the blind and 1.98m/sec for the normal. Also, composite speed also shows us big difference between 2.41m/sec of the blind and 4.07m/sec of the normal. The speed body center of take-off was expose that average adjuster are big width of deceleration than average - beginning disabled person's average by 2.23m/sec - 1.71m/sec in the vertical speed. 5. If examine change of high and low for z Sign of right hand, change of high and low showed as is small than normal person is sight obstacle, and all hand movements are small and was expose that do not use enough reaction of body as well as in ready action.

Determinants of Apartment Prices in Busan: A Spatial Quantile Regression (공간적 분위수 회귀분석에 의한 부산 아파트 가격 결정요인 분석)

  • Yoon, Jong-Won;Park, Sae-Woon;Jeong, Tae-Yun
    • Management & Information Systems Review
    • /
    • v.37 no.1
    • /
    • pp.155-175
    • /
    • 2018
  • Lots of previous researches on determinants of apartment prices in Korea consider spatial dependence while few studies regard endogeneity of spatial lag by adding a spatial lag to an OLS regression. Thus, this study intends to include this spatial lag in its analysis of determinants of apartment price in Busan by using a two-stage quantile regression. The empirical results are : the coefficient of spatial lag variable is more than 0.5 and is statistically significant at 1% level. From this result we can confirm that the effect of the price of nearby apartment on that of another apartment is very big. We also find that apartment buyers prefer larger size, height in both the total floors and living floor, south-facing living room with a ocean view, and proximity to metros, high school and coast. Unlike our expectation, however, mountain view is less favored than building view, which we can guess is because apartments with mountain views are mostly located in the low-priced apartment area where some of their living rooms face north. Quantile regression also explains the effect of hedonic characteristics on apartment price better than OLS estimation. For instance, the effect of south facing living room variable on the price is twice larger in high-price apartments than in low-price counterparts. And the effect of vicinity to the coast or the ocean is ten times bigger in high priced apartments.

Dynamic Position Control Method for the Buffer Unit of a Deepsea Mining System (해석심해자원개발용 버퍼의 동적위치제어기법)

  • Kim, Ki-Hun;Choi, Hang-S.;Hong, Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.3
    • /
    • pp.57-63
    • /
    • 2002
  • This paper describes a control algorithm for the buffer of a deep-sea mining system, in which the buffer is connected to a long slender pipe and then to a surface ship on one end, and to a collector on sea floor through a flexible hose on the other end. A mathematical modeling is established for designing the controller for buffer thrusters, in which the dynamic response of the long pipe is taken into account based on the mode superposition method. The fluid loading acting on the pipe is estimated by using Morison's formula. For simplicity, the surface ship is assumed to be kept stationary, the reaction from the flexible hose is ignored and only the lateral motions are considered. In order to guide the buffer to react only to the low-frequency motion of the surface vessel, the FIR digital filter is introduced to a PID-based controller It can be shown numerically that the high frequency component of the ship's motion can be effectively filtered out by using the FIR low pass filter.

Evaluation of Seismic Behavior for RC Moment Resisting Frame with Masonry Infill Walls (비내력벽을 가진 RC모멘트저항골조의 지진거동 평가)

  • Ko, Hyun;Kim, Hyun-Su;Park, Yong-Koo;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.13-22
    • /
    • 2010
  • Masonry infill walls are frequently used as interior partitions and exterior walls in low- or middle- rise RC buildings. In the design and assessment of buildings, the infill walls are usually treated as non-structural elements and they are ignored in analytical models because they are assumed to be beneficial to the structural responses. Therefore, their influences on the structural response are ignored. In the case of buildings constructed in the USA in highly seismic regions, infill walls have a lower strength and stiffness than the boundary frames or they are separated from the boundary frames. Thus, the previously mentioned assumptions may be reasonable. However, these systems are not usually employed in most other countries. Therefore, the differences in the seismic behaviors of RC buildings with/without masonry infill walls, which are ignored in structural design, need to be investigated. In this study, structural analyses were performed for a masonry infilled low-rise RC moment-resisting frame. The infill walls were modeled as equivalent diagonal struts. The seismic behaviors of the RC moment-resisting frame with/without masonry infill walls were evaluated. From the analytical results, masonry infill walls can increase the global strength and stiffness of a structure. Consequently, the interstory drift ratio will decrease but seismic forces applied to the structure will increase more than the design seismic load because the natural period of the structure decreases. Partial damage of the infill walls by the floor causes vertical irregularity of the strength and stiffness.

Evaluation of Interior Factors in Gyunro-dang and Recommendations for Improvement -In 14 Facilities at Apartment Complex in Seoul- (경로당 실내환경 평가와 개선방안 -서울지역 아파트 단지 내 14개 시설을 중심으로-)

  • 천진희
    • Archives of design research
    • /
    • v.17 no.3
    • /
    • pp.353-362
    • /
    • 2004
  • This research has been done to evaluate the interior environmental factors in Gyungro-dang to suggest the advanced recommendations for them. For this research, the essential interior elements influencing on elderly's behavior were examined with the developed checklist, the lighting and color conditions of main hall at 14 facilities in Seoul area were analysed, and 124 subjects staying at Gyungro-dang were participated in questionaire survey for color preferences. Results showed that 1.The average installation rate of 39 items in checklist was 59%, the mandatory items such as accessible dimension were considered, but several items related to mobility and safety were not properly installed. Therefore not only guiding handrail and floor block to destination but also elimination of obstacles should be reconsidered. 2.The average of illuminances was 289 Lux dose to standard 300 Lux, but lighting quality was too low to support the activities of elderly users. The lighting control devices, combined lighting sources, and suitable lighting techniques should be applied for those facilities. 3.Most facilities were predominantly in warm colors in hue, medium or high value, low saturation, and natural atmosphere with similarity harmony. The color applications in those facilities were not functional, but similar as color preferences for the elderly except overall atmosphere. It is recommendable to include contrast harmony with classic or romantic mood.

  • PDF

Evaluation of Intensity of Extremely Low Frequency Magnetic Fields (ELF-MF) Inside of Cabins as Generated During Subway Operation (지하철 운행 중 발생하는 객차 내부 극저주파 자기장(ELF-MF) 세기 평가)

  • Lee, Jihyun;Kang, Myeongji;Park, Yunkyung;Park, Donguk;Choi, Sangjun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.185-194
    • /
    • 2019
  • Objective: This study was conducted to investigate the intensity of the extremely low frequency magnetic fields(ELF-MF) generated inside of the cabins during subway operation. Methods: The ELF-MF intensity were investigated on 30 subway lines in Korea, including in the Greater Seoul Metropolitan Area(Seoul and Gyeonggi-do Province), Incheon, Busan, Daegu, Daejeon, and Gwangju. ELF-MF intensity was measured at 0.9 m from the floor using EMDEX II meters with a resolution of $0.01{\mu}T$. All data were collected every three seconds and analyzed with EMCALC 2013 version 3.0B software. Basic characteristics of subway operation, including alternative current(AC) or direct current(DC), voltage level, and opening year of the line were investigated. Real-time information during measurement, such as the time of departure, moving and arrival of trains, were also recorded. Results: The arithmetic mean(AM) and maximum(Max) intensity of ELF-MF were $0.62{\mu}T$ and $11.51{\mu}T$, respectively. Compared by region, the ELF-MF intensity measured inside cabin were the highest in the Seoul Metropolitan Area($AM=0.80{\mu}T$), followed by Busan($AM=0.30{\mu}T$), Daegu($AM=0.29{\mu}T$), Incheon($AM=0.14{\mu}T$), Gwangju($AM=0.04{\mu}T$) and Daejeon($AM=0.03{\mu}T$). The average ELF-MF level measured in AC trains($AM=1.36{\mu}T$) was also significantly higher than in DC trains($AM=0.28{\mu}T$). In terms of the opening year of the subway, trains opened before 1990($AM=0.85{\mu}T$) was the highest and the lowest was 2000-2009($AM=0.24{\mu}T$). Conclusions: The AC supply has the greatest influence on the generation of the ELF-MF intensity in subway cabins.

Effects of stocking density and dietary vitamin C on performance, meat quality, intestinal permeability, and stress indicators in broiler chickens

  • Yu, Dong Gwon;Namgung, Nyun;Kim, Jong Hyuk;Won, Seung Yeon;Choi, Won Jun;Kil, Dong Yong
    • Journal of Animal Science and Technology
    • /
    • v.63 no.4
    • /
    • pp.815-826
    • /
    • 2021
  • The objective of the current study was to investigate the effects of stocking density (SD) and dietary supplementation of vitamin C on growth performance, meat quality, intestinal permeability, and stress indicators in broiler chickens. The study was conducted using a completely randomized design with a 2 × 2 factorial arrangement consisting of 2 different SD and 2 supplemental levels of dietary vitamin C. A total of 1,368 Ross 308 broiler chickens of 21 days of age with similar body weights (BW) were randomly allotted to 1 of 4 treatments with 6 replicates each. Different numbers of birds per identical floor pen (2.0 m × 2.4 m) were used to create 2 different SD levels of low SD (9 birds/m2) and high SD (18 birds/m2). The basal diet was formulated with no supplemental vitamin C to meet or exceed nutrient recommendations of the Ross 308 manual. The other diet was prepared by supplementing 200 mg/kg vitamin C in the basal diet. The study lasted for 14 days. At the end of the study, 3 male birds per replicate were selected to analyze meat quality, intestinal permeability, and stress indicators such as blood heterophil:lymphocyte (H:L) and feather corticosterone (CORT) concentrations. Results indicated that there were no interactions between different SD and dietary supplementation of vitamin C for all measurements. For the main effects of SD, birds raised at high SD had less (p < 0.01) BW, BW gain, and feed intake with increasing stress responses including greater blood H:L and feather CORT concentrations (p < 0.01) than those raised at low SD. Transepithelial electrical resistance in the jejunal mucosa was decreased (p < 0.05) at high SD, indicating an increase in intestinal permeability. However, the main effects of dietary supplementation of 200 mg/kg vitamin C were insignificant for all measurements. In conclusion, high SD of broiler chickens impairs growth performance and intestinal barrier function with increasing stress responses. However, dietary supplementation of vitamin C may have little beneficial effects on broiler chickens raised at the high SD condition used in the present study.

A Study on the optimized Performance Designing of the Window of the Apartment based on the Annual Energy Demand Analysis according to the Azimuth Angle applying the Solar Heat Gain Coefficient of the Window (창호에 SHGC를 반영한 공동주택의 방위각별 에너지 효율성 평가를 통한 합리적인 창호 계획 방안 연구)

  • Lee, Jang-bum
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.11
    • /
    • pp.25-34
    • /
    • 2019
  • It is important to design windows in a reasonable way considering the performance characteristics of the elements of the window rather than just to increase the thermal energy performance of the window. In this study, the Heat-transfer Coefficient as insulation performance of the windows and together with the grade of the glass's SHGC (Solar Heat Gain Coefficient) were analyzed to relate to the energy efficiency performance of the building by azimuth angle. Based on this basic study, the Heat-transfer Coefficient of windows and the SHGC rating of glass were applied to the unit plan of apartment building, and the Heating and Cooling Demand were analyzed by azimuth angle. Apartment plan types were divided into 2 types of Non-extension and extension of balcony. The designPH analysis data derived from the variant of the Heat-transfer Coefficient and SHGC, were put into PHPP(Passive House Planning Package) to analyze precisely the energy efficiency(Heating and Cooling Demands) of the building by azimuth angle. In addition, assuming the 'ㅁ' shape layout, energy efficiency performance and potential of PV Panel installation also were analyzed by floors and azimuth angle, reflecting the shading effects by surrounding buildings. As the results of the study, the effect of Heat Gain by SHGC was greater than Heat Loss due to the Heat-transfer Coefficient. So it is more effective to increase SHGC to satisfy the same Heating Demand, and increasing SHGC made possible to design windows with low Heat-transfer Coefficient. It was also revealed that the difference in annual Heating and Cooling Demands between the low, mid and high floor households is significantly high. In addition to it, the installation of PV Panel in the form of a shading canopy over the window reduces the Cooling Load while at the same time producing electricity, and also confirmed that absolute thermal energy efficiency could not be maximized without controlling the thermal bridge and ventilation problems as important heat loss factors.

Safety Evaluation of Evacuation in a Dormitory Girls' High School based on PAPS (PAPS에 기반한 여자고등학교 기숙사생의 피난 안전성 평가)

  • Jeon, Seung-duk;Kong, Ha-sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.469-481
    • /
    • 2022
  • This study is for increasing evacuation safety by analyzing RSET(the required safe escape time) through the arrangement of personnel by floor and by room while evacuating in a Girls' High School Dormitory. For this study, PAPS(Physical Activity Promotion System) results that have not been studied so far were analyzed and reflected in evacuation simulations on the premise that individual student's physical strength can affect evacuation. Based on the PAPS results, four scenarios were applied. In addition, evacuation simulation using the pathfinder program was conducted in two situations: the evacuation route was assigned or not. Scenario 4 was the fastest at 168.5 seconds of RSET in assigning evacuation routes among scenarios. As a result of this study, the arrangement of students focusing on improving their academic ability and student life guidance excluding student physical strength has problem. In order to solve this problem, it is effective to place C group students(low grade on PAPS) on low floors and A group students(high grade on PAPS) on high floors and to assign evacuation routes in each room. In the future, the following ways need to be more studied. A study on how to increase evacuation safety through practical evacuation training, the way of assessing evacuation safety reflecting the lifestyle and physical strength of girls, the evacuation route assignment according to the fire occurrence point, and the method to secure evacuation routes in the event of a fire near stairs or entrances should be conducted.

A study on the location of microphones in measurement considering the frequency characteristics of elevator noise in households (세대 내 승강기 소음 주파수특성을 고려한 측정 시 마이크로폰 위치에 관한 연구)

  • Min-Woo Kang;Yang-Ki Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.124-132
    • /
    • 2023
  • When the building becomes high, the number of households increases and they are adjacent to the elevator. So, frequency of use of elevators will increase. Elevator noise is bound to increase in the future. However, there are currently no legal standards for elevator noise or measurement and evaluation methods that can clearly measure elevator noise in Korea. Although some methods for measuring elevator noise are presented in KS F ISO 16032, this standard is not a standard established for elevator noise. It is a standard that integrates the overall measurement method of building equipment and equipment, and the position of the microphone is selected by the experimenter during measurement. Elevator noise is characterized by a low sound pressure level as the noise in the mid-low frequency band is important. However, even today, complaints from residents about elevator noise are increasing. In this study, the position of the microphone that can most sensitively pick up the elevator noise when measuring the elevator noise was studied. According to the distance from the wall and the height from the floor, a total of 9 microphone positions were measured and analyzed. As a result of the experiment, it was confirmed that the elevator noise has a very high influence in the 63 Hz band. The measured value at the center point was identified as a factor that lowered the overall elevator noise level value.