• 제목/요약/키워드: Low-energy Building

검색결과 542건 처리시간 0.022초

환경부하 저감을 위한 기후순응주거 사례연구 (A Case Study on the Acclimatization's Housing for Environmental Load Reduction)

  • 조성우;오세규
    • 한국주거학회논문집
    • /
    • 제24권6호
    • /
    • pp.69-79
    • /
    • 2013
  • The concept of sustainable development to preserve natural environment through economy in resources and energy is gradually distinguished since environmental problems as a series of air pollution and global warming take place now. Building occupies more than 1/3 of energy consumption in the whole world. Energy consumption of buildings caused a quick increase in the amount of energy use by air conditioning, which has a lot of effects on exhaustion of fossil energy as well as an increase in environmental load. Therefore, this research intends to suggest characteristics and direction for the designing of acclimatization's housing through the case study on acclimatization's housing. Acclimatization's housing is designed to reduce building load from the designing stage unlike green home or low-energy apartment. Also, factors which are commonly applied to acclimatization's housing are applied complexly by design strategic factors of Heating, Cooling and Lighting. The applied design factors make effects mutually and complexly. In addition, design strategy showed different priority by designing direction.

건설현장 내 에너지 사용량에 따른 환경영향 평가에 관한 연구 (A Study on the Evaluation of the Environmental Impact of Energy Usage in Construction Sites)

  • 이충원;태성호;장형제;임효진;김현숙
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.119-120
    • /
    • 2022
  • As the seriousness of the climate crisis is emphasized, movements to solve it are becoming active. In Korea, efforts to reduce environmental impacts across all industries are being strengthened through the Framework Act on Low Carbon Green Growth. The construction industry predicts the environmental impact of buildings during the entire life cycle, but in the construction process, there is a difference in energy usage depending on the amount of input, and it is difficult to predict the environmental impact if data cannot be collected. Therefore, this study evaluated the environmental impact of energy usage in the apartment construction process as part of the study on predicting and reducing the environmental impact of the construction process of the construction site. To this end, the environmental effects of buildings were set as global warming, resource consumption, and ozone layer effects, and the environmental effects of the actual energy use in the case were evaluated. In addition, based on the evaluation results, the characteristics of the input energy usage were compared and analyzed.

  • PDF

자가발전 스마트 액정 윈도우를 위한 염료감응 태양전지 서브 모듈 설계 및 평가 (Design and Evaluation of Dye-Sensitized Solar Cell Submodule for Self-Powered Smart Liquid Crystal Window)

  • 오병윤
    • 한국전기전자재료학회논문지
    • /
    • 제37권5호
    • /
    • pp.494-499
    • /
    • 2024
  • The possibility of a dye-sensitized solar cell (DSSC) submodule was evaluated as an independent power source that can drive a smart liquid crystal window (SLW) that selectively blocks sunlight when electricity is applied. In order to save energy and increase the functionality of buildings, SLW operation was supplied directly from DSSC submodule, rather than connecting to the existing power system and external power sources. It was confirmed that the SLW can control light transmittance through self-generation using the DSSC submodule composed of 6 cells at low light of 2,500 lux. These results imply that there is a high possibility of combining smart windows and DSSCs suitable for window-type building-integrated photovoltaic (BIPV) systems. DSSCs, which can self-generate power in low light, are expected to increase their usability in urban BIPV systems through combination with smart window technology.

The ASHRAE Design Guide for Tall, Supertall and Megatall Building Systems

  • Simmonds, Peter
    • 국제초고층학회논문집
    • /
    • 제4권4호
    • /
    • pp.311-318
    • /
    • 2015
  • The ASHRAE Design Guide for Tall, Supertall and Megatall Building Systems was produced in collaboration with the CTBUH. The design guide outlines various tall building mechanical systems that are presently being designed or are planned for the future. Tall commercial buildings in particular present a series of design problems that set them apart from other functions. The Design Guide will be of interest to owners, architects, structural engineers, mechanical engineers, electrical engineers and other specialized engineers and consultants. This design guide addresses design issues for tall commercial buildings, which are very often mixed-use, and commonly consist of low level retail, office floors, residential units, and hotel uses.

공동주택의 단열 및 차양에 따른 구체축열시스템 냉방성능 평가 (Evaluation on Cooling Performance of Thermally Activated Building System by Insulation and Shading Conditions in Apartments)

  • 유미혜;여명석;이유지;정웅준;박상훈;김광우
    • 한국주거학회논문집
    • /
    • 제23권2호
    • /
    • pp.107-114
    • /
    • 2012
  • Thermally Activated Building System(TABS) is a radiant heating and cooling system which uses structures as thermal storage by embedding pipes in a concrete slab. Using TABS as the cooling system in residential buildings can reduce energy consumption and peak loads. But the ratio of cooling loads handled by TABS is low in the residential buildings which are significantly influenced by outside condition because condensation and over-cooling may occur. However, recent interest on energy-saving buildings is increasing and new residential buildings are expected to be less influenced by outside with high-insulation and shading. In such residential buildings, the heating and cooling loads and the range of load changes reduce. So the ratio of loads handled by TABS can increase. Therefore, this research investigates the cooling performance and energy performance of TABS in the residential buildings with less influence from outside using the simulation.

Surface temperatures of public buildings, built in 1880, 1970 and 2002, in Northern Greece

  • Kosmopoulos, P.;Kantzioura, A.
    • Advances in Energy Research
    • /
    • 제1권1호
    • /
    • pp.79-95
    • /
    • 2013
  • The purpose of this paper is to investigate the surface temperatures of the shelter of three public buildings in the city of Xanthi, in northern Greece. The buildings were built in different time periods and consequently they have different technical characteristics. Respectively, we survey the three following buildings that have been built in 1880 (Municipality Hall of Xanthi), in 1970 (Municipality Amphitheatre) and in 2002 (Bank offices building). Data have been gathered by the use of thermal camera and the survey has been conducted from January up to July. The data gathered regard measurements of the surface temperature of the exterior walls of the shelters, both inside and outside. The study aims at the evaluation of the thermal behavior of the shelter of buildings, which built in different time and under different regulations. The gathered data of the surface temperatures compare the different thermal behavior of the shelter. The analysis of the results and diagrams show that the thick masonry of the traditional Municipality Hall offers an insulation that is adequate. The building of 1970, which was constructed with the previous buildings regulation, has thermal losses due to inadequate insulation. The new building of 2002 has low thermal losses.

Cold facade형 BIPV시스템의 발전성능 분석 (Analysis of Performance of Building Integrated PV System of Cold Facade type)

  • 김현일;강기환;박경은;유권종;서승직
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.275-280
    • /
    • 2008
  • Photovoltaic(PV) permit the on-site production of electricity without concern for fuel supply or environmental adverse effects. The electrical power is produced without noise and little depletion of resources. So BIPV(Building-Integrated Photovoltaic) system have been increased around the world. Hereby the relative installation costs of the system will be relatively low compared to traditional installations of PV in high-rise buildings. This paper examined possibility of BIPV system of cold facade type and analyzed of performance of BIPV system of cold facade type. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. If this BIPV system of 1.1kW is possible the natural ventilation in the summer case, the temperature of PV module decrease and then the efficiency of PV system increase generally. By the results, the annual averaged PR of BIPV system of cold facade type is about 73.1%.

  • PDF

Experiment research on seismic performance of prestressed steel reinforced high performance concrete beams

  • Xue, Weichen;Yang, Feng;Li, Liang
    • Steel and Composite Structures
    • /
    • 제9권2호
    • /
    • pp.159-172
    • /
    • 2009
  • Two prestressed steel reinforced high performance concrete (SRC) beams, a nonprestressed SRC beam and a counterpart prestressed concrete beam were tested under low reversed cyclic loading to evaluate seismic performance of prestressed SRC beams. The failure modes, deformation restoring capacity, ductility and energy dissipation capacity of the prestressed SRC beams were discussed. Results showed that due to the effect of plastic deformations of steel beams encased in concrete, the three SRC beams exhibited residual deformation ratios ranging between 0.64 and 0.79, which were apparently higher than that of the prestressed concrete beam (0.33). The ductility coefficients of the prestressed SRC beams and the prestressed concrete beam ranged between 4.65 and 4.87, obviously lower than that of nonprestressed SRC beam (9.09), which indicated the steel beams influenced the ductility little while prestressing resulted in an apparent reduction in ductility. The amount of energy dissipated by the prestressed SRC beams was less than that dissipated by the nonprestressed SRC beam but much more than that dissipated by the prestressed concrete beam.

국내 여름철 기후조건에서 DOAS와 TABS 통합시스템 냉방운전시 실내온열환경 및 운전특성 평가 (Evaluation on the Indoor Thermal Environment and Cooling Operation Characteristics of Thermally Activated Building System integrated with Dedicated Outdoor Air System during Cooling Operation in Hot and Humid Climate of Seoul)

  • 이윤선;이겨레;정웅준;임재한
    • 대한건축학회논문집:계획계
    • /
    • 제34권11호
    • /
    • pp.45-55
    • /
    • 2018
  • To reduce the energy consumption of HVAC system in buildings, thermally activated building system(TABS) has been applied to low energy building because of energy efficient performance and reduction of peak load. DOAS coupled with a parallel sensible cooling could be promising because TABS handles sensible heat load only. The purpose of this study was to evaluate the indoor thermal environment and cooling operation characteristic of TABS with dedicated outdoor air system(DOAS) in Korea climate. Indoor thermal environment and operation characteristic of TABS integrated with DOAS are investigated at different TABS operation schedules and climate conditions by simulation tests. The result shows that the DOAS is more suitable for hot and humid climates. And also it show that the potential of intermittent operation of TABS.

Appilication of a Green City Index as a Green Space Planning Index for the Low-Carbon Green City of Gangneung-si

  • Cho, Su-Hyun;Jo, Hyun-Ju
    • 한국환경과학회지
    • /
    • 제25권10호
    • /
    • pp.1381-1387
    • /
    • 2016
  • This study aims to establish baseline data for sustainable monitoring by applying the green city index (GCI), which is set up to evaluate the city level, to the city of Gangneung-si, which was designated as a pilot city for the Low-carbon Green Growth City project by the Ministry of Land, Infrastructure, and Transportation. The GCI was applied in the framework of European systems, while considering the social and economic status of Korea. Indicators from 7 areas-$CO_2$, energy, building, transportation, water, waste, and quality of atmosphere were analyzed, except for qualitative indicators. Results indicate that total $CO_2$ emissions were 30.8 tons per capita, or 2.2 tons per one million units of real GDP. The total final energy consumption was 0.231 TOE/capita, or 0.317 TOE per one million units of real GDP. The percentage of total energy derived from renewable resources was 0.41% and energy consumption by the building was $433.5Mwh/1,000m^2$. The total percentage of the working population travelling to work daily by public transportation (limited to bus) was 19%. Further, the total annual water consumption was $99m^3/capita$, and the water lost in the water distribution system was $0.057m^3/capita/day$. The total annual waste collected was 0.0077 ton per capita, The annual mean emission were 0.014 ppm/day for $NO_2$, 0.005 ppm/day for $SO_2$, and 0.019 ppm/day for $O_3$. The annual mean for PM10 emissions was $39{\mu}g/m^3/day$.