• Title/Summary/Keyword: Low-dose (mGy) X-rays

Search Result 6, Processing Time 0.024 seconds

Unveiling the direct conversion X-ray sensing potential of Brucinium benzilate and N-acetylglcyine

  • T. Prakash;C. Karnan;N. Kanagathara;R.R. Karthieka;B.S. Ajith Kumar;M. Prabhaharan
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2190-2194
    • /
    • 2024
  • The study investigates the dose-dependent direct X-ray sensing characteristics of Brucinium benzilate (BB) and N-acetylglycine (NAG) organic crystals. BB and NAG were prepared as a slurry and deposited as a thick film on a patterned metal electrode. The X-ray induced photocurrent response was examined for various exposure doses using an intraoral pulsed 70 keV X-ray machine connected to a source meter. Subsequently, the morphological properties and thickness of the thick films were analyzed using scanning electron microscopy (SEM). At a photon energy of 70 keV, the attenuation coefficient values for NAG and BB crystals were determined to be approximately 0.181 and 0.178 cm2/g, respectively. The X-ray stopping power of the crystals was measured using a suniray-2 X-ray imaging system. To evaluate the responsiveness of the sensors, the photocurrent sensitivity and noise equivalent dose rate (NED) were calculated for both thick films. The findings demonstrated a noteworthy capability of sensing low doses (mGy), thereby suggesting the potential application of these organic materials in X-ray sensor development.

X-Rays through the Looking Glass: Mobile Imaging Dosimetry and Image Quality of Suspected COVID-19 Patients

  • Schelleman, Alexandra;Boyd, Chris
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.120-126
    • /
    • 2021
  • Background: This paper aims to evaluate the clinical utility and radiation dosimetry, for the mobile X-ray imaging of patients with known or suspected infectious diseases, through the window of an isolation room. The suitability of this technique for imaging coronavirus disease 2019 (COVID-19) patients is of particular focus here, although it is expected to have equal relevance to many infectious respiratory disease outbreaks. Materials and Methods: Two exposure levels were examined, a "typical" mobile exposure of 100 kVp/1.6 mAs and a "high" exposure of 120 kVp/5 mAs. Exposures of an anthropomorphic phantom were made, with and without a glass window present in the beam. The resultant phantom images were provided to experienced radiographers for image quality evaluation, using a Likert scale to rate the anatomical structure visibility. Results and Discussion: The incident air kerma doubled using the high exposure technique, from 29.47 µGy to 67.82 µGy and scattered radiation inside and outside the room increased. Despite an increase in beam energy, high exposure technique images received higher image quality scores than images acquired using lower exposure settings. Conclusion: Increased scattered radiation was very low and can be further mitigated by ensuring surrounding staff are appropriately distanced from both the patient and X-ray tube. Although an increase in incident air kerma was observed, practical advantages in infection control and personal protective equipment conservation were identified. Sites are encouraged to consider the use of this technique where appropriate, following the completion of standard justification practices.

Breeding of four-leaf white clover (Trifolium repens L.) through 60Co gamma-ray irradiation

  • Song, In-Ja;Kang, Hong-Gyu;Kang, Ji-Yeon;Kim, Hae-Deun;Bae, Tae-Woong;Kang, Si-Young;Lim, Pyung-Ok;Adachi, Taiji;Lee, Hyo-Yeon
    • Plant Biotechnology Reports
    • /
    • v.3 no.3
    • /
    • pp.191-197
    • /
    • 2009
  • Four-leaf white clover is not found easily in nature due to its low appearance rate (1 in 10,000). Because people believe that it brings good luck and like to either keep it or present it to a loved one, it has commercial and ornamental value. To breed four-leaf clover, we exposed its flowers to ${\gamma}-rays$ at the pollination stage. The $M_1$ seeds produced following doses at 25-100 Gy showed an approximately 74% germination rate, with seedling survival at 46%. In the $M_1$ generation of plants irradiated within that dose range, we found an increased frequency of four leaflets. One of them, Jeju Lucky-1 (JL-1), had a frequency of about 60%. To see whether that mutation was somaclonal or genetic, we observed its $M_2$ generation and found that such a phenotype reappeared. Although our results demonstrated that the irradiation of fully mature flowers led to a higher frequency of 4-leaflets, we could not clearly explain the genetic mechanism involved. We suggest that JL-1 is valuable as a new variety, without further genetic fixation, because white clover can be propagated vegetatively by stolons.

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF

Postoperstive Chemoradiotherapy in Locally Advanced Rectal Cancer (국소 진행된 직장암에서 수술 후 화학방사선요법)

  • Chai, Gyu-Young;Kang, Ki-Mun;Choi, Sang-Gyeong
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Purpose : To evaluate the role of postoperative chemoradiotherapy in locally advanced rectal cancer, we retrospectively analyzed the treatment results of patients treated by curative surgical resection and postoperative chemoradiotherapy. Materials and Methods : From April 1989 through December 1998, 119 patients were treated with curative surgery and postoperative chemoradiotherapy for rectal carcinoma in Gyeongsang National University Hospital. Patient age ranged from 32 to 73 years, with a median age of 56 years. Low anterior resection was peformed in 59 patients, and abdominoperineal resection in 60. Forty-three patients were AJCC stage II and 76 were stage III. Radiation was delivered with 6 MV X rays using either AP-PA two fields, AP-PA both lateral four fields, or PA both lateral three fields. Total radiation dose ranged from 40 Gy to 56 Gy. In 73 patients, bolus infusions of 5-FU $(400\;mg/m^2)$ were given during the first and fourth weeks of radiotherapy. After completion of radiotherapy, an additional four to six cycles of 5-FU were given. Oral 5-FU (Furtulone) was given for nine months in 46 patients. Results : Forty $(33.7\%)$ of the 119 patients showed treatment failure. Local failure occurred in 16 $(13.5\%)$ patients, 1 $(2.3\%)$ of 43 stage II patients and 15 $(19.7\%)$ of 76 stage III patients. Distant failure occurred in 31 $(26.1\%)$ patients, among whom 5 $(11.6\%)$ were stage II and 26 $(34.2\%)$ were stage III. Five-year actuarial survival was $56.2\%$ overall, $71.1\%$ in stage II patients and $49.1\%$ in stage III patients (p=0.0008). Five-year disease free survival was $53.3\%$ overall, $68.1\%$ in stage II and $45.8\%$ in stage III (p=0.0006). Multivariate analysis showed that T stage and N stage were significant prognostic factors for five year survival, and that T stage, N stage, and preoperative CEA value were significant prognostic factors for five year disease free survival. Bowel complication occurred in 22 patients, and was treated surgically in 15 $(12.6\%)$, and conservatively in 7 $(5.9\%)$. Conclusion : Postoperative chemoradiotherapy was confirmed to be an effective modality for local control of rectal cancer, but the distant failure rate remained high. More effective modalities should be investigated to lower the distant failure rate.