• Title/Summary/Keyword: Low-cost device

Search Result 704, Processing Time 0.026 seconds

A Study on the Development of a Low-cost Device for Measuring the Optical Smoke Density (광학적 연기밀도 측정을 위한 저가형 장치의 개발에 관한 연구)

  • Kim, Bong-Jun;Cho, Jae-Ho;Hwang, Cheol-Hong;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.81-88
    • /
    • 2015
  • A low-cost device using the light-extinction method was developed to measure the optical smoke density in various fire experiments in the present study. The relative measurement accuracy of low-cost device was evaluated through the comparison of optical density measured by a high-cost standard device consisting of He-Ne laser, photo detector and various optical components. The low-cost device was composed of laser module, photocell and acrylic board. From the experiments using a smoke generator can be easily adjusted the smoke concentration, it was found that the low-cost device could measure the smoke density within the range of ${\pm}10%$, compared to the standard device. In addition, the reliability of low-cost device was also confirmed in the experiment using a polyethylene flame. Finally, it is expected that the low-cost device developed with real-time measurement and simple installation for measuring the smoke density will be used instead of the high-cost standard device.

A Study on Improvement of Low-power Memory Architecture in IoT/edge Computing (IoT/에지 컴퓨팅에서 저전력 메모리 아키텍처의 개선 연구)

  • Cho, Doosan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.1
    • /
    • pp.69-77
    • /
    • 2021
  • The widely used low-cost design methodology for IoT devices is very popular. In such a networked device, memory is composed of flash memory, SRAM, DRAM, etc., and because it processes a large amount of data, memory design is an important factor for system performance. Therefore, each device selects optimized design factors such as function, performance and cost according to market demand. The design of a memory architecture available for low-cost IoT devices is very limited with the configuration of SRAM, flash memory, and DRAM. In order to process as much data as possible in the same space, an architecture that supports parallel processing units is usually provided. Such parallel architecture is a design method that provides high performance at low cost. However, it needs precise software techniques for instruction and data mapping on the parallel architecture. This paper proposes an instruction/data mapping method to support optimized parallel processing performance. The proposed method optimizes system performance by actively using hardware and software parallelism.

A Portable Micro-display Driver and Device for Vision Improvement (시력 향상을 위한 휴대형 마이크로디스플레이 구동 드라이버 및 장치)

  • Ryu, Young-Kee;Oh, Choonsuk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.129-135
    • /
    • 2016
  • There are many visual enhancement devices for people with low vision. However, almost conventional devices have been simple magnifying and high cost. The symptoms of people with low vision are very variety. It needs to control of image magnifying, brightness, and contrast to improve the visuality. We developed a portable microdisplay driver and device for visual enhancement. This device based on our suggested four methods such as image magnifying, specific color control, BLU brightness control, and visual axis control using a prism. The basic clinical experiments of the proposed Head Mounted Visual Enhancement Device (HMVED) have been performed. The results show beneficiary effects compared with conventional devices, and improve the life quality on people with low vision on account of low weight, low cost, and easy portability.

Development of a Low-cost Metering Device for Automatic Mixing of Nutrient-Solution

  • Ryu, K.H.;Lee, K.C.;Lee, J.H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1117-1125
    • /
    • 1996
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering accuracy of the metering device developed was compared with commercial metering pumps. The mixing performance through the control of EC and pH was also evaluated. The accuracy of the metering device in terms of the full -scale error was $\pm$0.3% , which was much better compared to $\pm$2.45% and $\pm$1.38% for the two types of commercial metering pumps. The mixing system of nutrient-solution with the metering device showed a satisfactory control performance with the accuracies of $\pm$0.05mS/cm and$\pm$0.2pH for EC and pH, respectively.

  • PDF

Experiment of a 3D Motion Input Device (3차원 운동 입력장치 구현)

  • Lee, Woo-Won;Choi, Myoung-Hwan
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.173-178
    • /
    • 1999
  • In many areas of technology there are machines and systems controllable in up to six degrees of freedom. Helicopters and underwater vehicles, industrial robots are among the first representatives of this category. They need six degrees of freedom in order to move and orient within their workspace. An even broader and more explosively growing area is 3D computer graphics and virtual environment. In this work, functions of 3D input device are described and two types of commercial 3D input device are presented. Then, a preliminary experiment of a low cost 6 axis force/moment sensor is presented that can also be sued as a 3D input device. A low cost force/moment sensor and its application in robot teaching experiment is described. It computes the direction of 3 components of the force and 3 components of the moment applied by human holding the sensor by hand. The concept is shown by an experiment where the tool position and orientation of a robot in 3 dimensional space is controlled by the proposed sensor.

  • PDF

Design and Implementation of Firmware for Low-cost Small PCR Devices (저가의 소형 PCR 장치를 위한 펌웨어 설계 및 구현)

  • Lee, Wan Yeon;Kim, Jong Dae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.6
    • /
    • pp.1-8
    • /
    • 2013
  • In this paper, we design and implement a firmware for low-cost small PCR devices. To minimize machine code size, the proposed firmware controls real-time tasks simultaneously only with support of the hardware interrupt, but without support of the operating system program. The proposed firmware has the host-local structure in which the firmware receives operation commands from PC and sends operation results to PC through usb communication. We implement a low-cost small PCR device with the proposed firmware loaded on microchip PIC18F4550 chip, and verify that the implemented PCR device significantly reduces cost and volume size of existing commercial PCR devices with a similar performance.

Development of a Low -Cost and Precise Liquid Metering Device for Automatic Nutrient-Solution Control (양액 자동조제용 액제 정밀계량 장치 개발)

  • 이정훈;류관희;이규철
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1997.12a
    • /
    • pp.255-262
    • /
    • 1997
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. Those parts were controlled by personal computer with time-based odoff control method. To verify the performance of the developed metering device, the relationship between operating time and discharge was examined and the accuracy of the developed metering device was compared with commercial metering pumps. The results of this study are as follows. 1. The correlation coefficient between the flow rate and operating time was 0.9999, and the linear regression equation computed was y=21.759x, where y is the discharge(g) and x is the operating time(s). 2. The developed device has greater accuracy than commercial metering pumps in terms of the full-scale error. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3 %, $\pm$2.45 % and $\pm$1.38 % respectively. 3. Above results show developed metering device is a useful tool for nutrient-solution control system.

  • PDF

Surface Acoustic Wave Sensor using Electroactive Paper (EAPap) (Electroactive Paper (EAPap)를 이용한 표면탄성파 센서)

  • Lee, Min-Hee;Kim, Joo-Hyung;Kim, Jae-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.368-371
    • /
    • 2008
  • Cellulose based Electroactive Paper (EAPap) has been developed as a new smart material due to its advantages of piezoelectricity, large displacement, low power consumption, low cost and flexibility. EAPap can be used fur a surface acoustic wave (SAW) device using the piezoelectric property of EAPap, resulting in the cost effective and flexible SAW device. In this paper, inter digit transducer (IDT) structure using lift-off technique with a finger gap of $10{\mu}m$ was used for micro fabrication of the cellulose EAPap SAW devices. The performance of IDT patterned SAW device was characterized by a Network Analyzer. The feasibility of cellulose EAPap as a potential acoustic device was presented and explained.

  • PDF

Surface Acoustic Wave Sensor Using Electroactive Paper(EAPap) (Electroactive Paper(EAPap)를 이용한 표면탄성파 센서)

  • Lee, Min-Hee;Kim, Joo-Hyung;Kim, Jae-Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.11
    • /
    • pp.1128-1133
    • /
    • 2008
  • Cellulose based electroactive paper(EAPap) has been developed as a new smart material due to its advantages of piezoelectricity, large displacement, low power consumption, low cost and flexibility. EAPap can be used for a surface acoustic wave (SAW) device using the piezoelectric property of EAPap, resulting in the cost effective and flexible SAW device. In this paper, inter digit transducer(IDT) structure using lift-off technique with a finger gap of 10mm was used for micro fabrication of the cellulose EAPap SAW devices. The performance of IDT patterned SAW device was characterized by a Network Analyzer. The feasibility of cellulose EAPap as a potential acoustic device was presented and explained.

RC Oscillator Based on Organic Thin Film Transistor

  • Kim, Seung-Kyum;Kim, Sang-Woo;Moon, Byeong-Cheon;Choi, Woon-Seop;Bae, Byung-Seong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1336-1339
    • /
    • 2007
  • Since organic thin film transistor (OTFT) provides simple and low cost processes, its application to the OTFT display has been studied. We developed an RC oscillator using organic thin film transistor and inverters with bootstrapping transistors. Device parameters were optimized by the simulation and OTFT RC oscillators were fabricated. The oscillator frequency and its dependence on resistance and bias voltage were studied. The organic TFT is adequate for low cost and simple process integrated circuits. The frequency of oscillation was simulated and measured. It is acceptable for low-cost microelectronic device and flat panel displays.