• Title/Summary/Keyword: Low-Level Laser

Search Result 247, Processing Time 0.031 seconds

Characterization of Placental Proteins in Bovine Somatic Cell Clone Fetuses

  • Woo, Jei-Hyun;Ko, Yeoung-Gyu;Kim, Bong-Ki;Kim, Jong-Mu;Lee, Youn-Su;Kim, Nam-Yun;Im, Gi-Sun;Yang, Boung-Chul;Seong, Hwan-Hoo;Jung, Jin-Kwan;Kwun, Moo-Sik;Chung, Hak-Jae
    • Reproductive and Developmental Biology
    • /
    • v.29 no.2
    • /
    • pp.83-91
    • /
    • 2005
  • Somatic cell nuclear transfer in cattle has limited efficiency in terms of production of live offspring due to high incidence of fetal failure after embryo transfer to recipients. Such low efficiency of cloning could possibly arise from abnormal and poorly developed placenta. In the present study the placental proteome in late pregnancy established from in vitro fertilization (IVF) and nuclear transfer (NT) was analysed. Proteome alternation was tested using two-dimensional polyacrylamide gel electrophoresis (2-DE) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI- TOF). Comparing placenta from NT embryos to those from IVF counterparts, significant changes in expression level were found in 18 proteins. Of these proteins 12 were not expressed in NT placenta but expressed in IVF counterpart, whereas the expression of the other 6 proteins was limited only in NT placenta. Among these proteins, cytokeratin 8 and vimentin are considered to be involved in regulation of post-implantation development. In particular, cytokeratin 8 and vimentin may be used as makers for placental development during pregnancy because their expression levels changed considerably in NT placental tissue compared with its IVF counterpart. Data from 2-DE suggest that protein expression was disorientated in late pregnancy from NT, but this distortion was eliminated with progression of pregnancy. These findings demonstrate abnormal placental development during late pregnancy from NT and suggest that alterations of specific placental protein expression may be involved in abnormal function of placenta.

Effects of Low-Level Laser Irradiation on the ALP Activity and Calcified Module Formation of Rat Osteoblastic Cell (저수준레이저(GaAs 반도체)조사가 골모세포의 알칼리성 인산분해효소의 활성과 석회화결절의 형성에 미치는 영향)

  • Kyung-Hun Lee;Ki-Suk Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.279-291
    • /
    • 1996
  • 저수준레에저요법에 대해서는 지난 10여년간 의학계 및 치과계에서 임상적으로 사용하여 좋은 결과가 있다고 많은 보고가 발표되고 있다. 특히 치근의 골결손에 관한 연구에서는 전기요법, 초음파요법, 전자장요법 등 뿐만아니라 저수준레이저를 사용하여 골절부내 Callus형성이 촉진되었음을 보고하고 새로운 치료법의 하나가 될 수 있음을 제안한 바도 있다. 본 연구에서는 칼륨비소를 다이오드로 사용한 저수준레이저조사가 골결손의 치유에 어떠한 영향을 미치는지 확인하고자 골모세포의 알칼리성 인산분해효소의 활성화와 석회화결절의 형성을 평가함으로 골모세포의 기능을 조사코저하였다. 실험은 첫째, 9개군으로 나누어 레이저 조사기간에 따른 알칼리성 인산분해효소의 활성화를 조사하였고, 둘째, 이를 근거로 9일간 계속 매일 1회 1.3 J/cm2의 레이저를 조사한 후 펄스의 종류별 차이를 비교하였으며, 세째,레이저펄스별 석회차 결절의 형성 정도를 광학현미경으로 관찰하여 비교분석하였다. 결과, 7일 계속 레이저를 조사한 경우 다른 군에 비해 서서히 ALP의 활성이 증가하였으나 유의한 차이는 없었으며. 따라서 9일동안 레이저를 계속 조사한 경우에는 전체 에너지량이 5.895 J/cm2 인 펄스13과 15가 뚜렷하게 유의한 증가를 보여주었다. 그러나 석회화결절의 형성은 전체 에너지량이 2.546 J/cm2 인 펄스11에서 가장 많았다. 결론적으로 골형성이나 알칼리성 인산분해효소의 활성을 촉진하는 데에는 적절한 레이저 조사조건이 필요하나, 알칼리성 인산분해효소의 활성을 촉진한 펄스와 석회화결절의 형성을 촉진하는 펄스가 서로 다르게 나타난 것은 골형성을 촉진하는 여러요인 들이 저수준레이저에 자극받았을 가능성이 높음을 보여준다 이러한 결과들로 보아 저수준레이저는 골모세포의 기능을 자극하여 골결손의 치유를 개선하는 데 도움될 것이라 사료된다.다. 각 백서의 양측 창상중 하나는 1,3,5,7일 마다 각 실험의 방법에 따라 레이저를 조사하고 실험동물의 다른 창상은 대조군으로서 사용하였다. 모든 창상의 면적은 실험 1,3,5,7 일째에 일정한 거리에서 사진촬영하여 면적계를 이용, 측정한 후 통계적인 의의를 조사하였다. 본 연구의 결과는 저수준레이저는 특정 조건하에서 S. aureus의 증식을 촉진하였다. 그러나 S. aureus에 감염된 창상을 저수준레이저로 조사시 치유가 촉진되었다. 중앙 조사법고 주변조사법에 의한 창상치유효과는 통계적인 의의가 보이지 않았다. 따라서 결론적으로 S. aureus 에 감염된 창상에 직접 또는 간접적이든 pulse의 종류에 관계없이 조사하는 경우 치유효과가 나타나는 것은 정사주위 조직의 LLLI 자극효과가 염증의 확산을 억제한다고 말할수 있다.4/1$0^{\circ}C$에서는 Shoa-Nan-Tsan과 Lenkwang이 가장 높았으며 백앙벼는 3 온도 조건 모두에서 활성이 낮았다. 발아소요일수와 amylase 활성과는 유의적인 정의 상관관계를 보였다., 다다조, 미국의 건답직파재배 품종 등이었으며 우리 나라 육성종들은 모두 지중에서 신장이 멈추어 제1본엽이 지중에서 추출하였으며, Scm파종심에서 불완전엽이 지면을 뚫고 나오는 품종은 Chinsura Boro뿐이었고 Nato, Labelle, Weld Pally, Italliconaverneco 등도 지면 가까이 까지 신장하였다. 6. 50% 출아일수는 제2절간장을 제외 한 모든 유아 형질의 신장도와 유의한 부의 상관을 보였는데 가장 높은 상관을 보인 것은 중배축장+제1절간장+불완전옆장이었으며, 다음이 불완전엽장이 었다. 7. 출아율은 중배축장+제1절간장+불완전엽장, 중배축장+초엽 장과 모든 파종심에서 높은 정의 상관을 보여 제1본엽의 추출 위치가 높을수록

  • PDF

Muscle Stiffness and Elasticity Related to Physical Therapeutic Modalities (물리치료에 따른 근육의 경도와 탄성도 비교)

  • Kim, Sung-Hwan;Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.319-328
    • /
    • 2007
  • The purpose of this study was to quantitatively assess treatment effect of physical therapy on experimentally-induced masseter muscle fatigue by two parameters of muscle stiffness and elasticity. Three physical therapeutic modalities inducing electroacupunture stimulation therapy(EAST), Microwave diathermy and low-level laser therapy(LLLT) were compared. 10 healthy volunteers with normal occlusion (mean age of $26.3{\pm}1.16$ years, M:F=1:1) were participated in this study. All subjects were asked to chew gum on the right side until they felt pain(more and VAS 5 (0 to 10)) and their masseter muscles were examined with a tactile sensor in order to evaluate changes of stiffness and elasticity according to gum chewing and three physical therapeutic modalities. Subjective discomfort or pain was self-estimated by VAS as well. Unilateral gum chewing increased stiffness and decreased elasticity only on the chewing side but VAS increased on the both sides(p<0.05). EAST or Microwave diathermy greatly decreased stiffness and VAS and increased elasticity(p<0.05) but LLLT did not exhibit significant difference. From the results of this study, it is concluded that both EAST and Microwave diathermy have favorable effect on stiffness and elasticity of muscles and pain relief while effect of LLLT is not reliable. In addition, experimental unilateral gum chewing compromises stiffness and elasticity of masseter muscles only the chewing side while subjective discomfort or pain can be felt on the both sides.

Reliable and High Spatial Resolution Method to Identify the Number of MoS2 Layers Using a Scanning Electron Microscopy

  • Sharbidre, Rakesh Sadanand;Park, Se Min;Lee, Chang Jun;Park, Byong Chon;Hong, Seong-Gu;Bramhe, Sachin;Yun, Gyeong Yeol;Ryu, Jae-Kyung;Kim, Taik Nam
    • Korean Journal of Materials Research
    • /
    • v.27 no.12
    • /
    • pp.705-709
    • /
    • 2017
  • The electronic and optical characteristics of molybdenum disulphide ($MoS_2$) film significantly vary with its thickness, and thus a rapid and accurate estimation of the number of $MoS_2$ layers is critical in practical applications as well as in basic researches. Various existing methods are currently available for the thickness measurement, but each has drawbacks. Transmission electron microscopy allows actual counting of the $MoS_2$ layers, but is very complicated and requires destructive processing of the sample to the point where it will no longer be useable after characterization. Atomic force microscopy, particularly when operated in the tapping mode, is likewise time-consuming and suffers from certain anomalies caused by an improperly chosen set point, that is, free amplitude in air for the cantilever. Raman spectroscopy is a quick characterization method for identifying one to a few layers, but the laser irradiation causes structural degradation of the $MoS_2$. Optical microscopy works only when $MoS_2$ is on a silicon substrate covered with $SiO_2$ of 100~300 nm thickness. The last two optical methods are commonly limited in resolution to the micrometer range due to the diffraction limits of light. We report here a method of measuring the distribution of the number of $MoS_2$ layers using a low voltage field emission electron microscope with acceleration voltages no greater than 1 kV. We found a linear relationship between the FESEM contrast and the number of $MoS_2$ layers. This method can be used to characterize $MoS_2$ samples at nanometer-level spatial resolution, which is below the limits of other methods.

Terahertz Generation and Detection Using InGaAs/InAlAs Multi Quantum Well

  • Park, Dong-U;Han, Im-Sik;No, Sam-Gyu;Ji, Yeong-Bin;O, Seung-Jae;Seo, Jin-Seok;Jeon, Tae-In;Kim, Jin-Su;Kim, Jong-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.205-205
    • /
    • 2013
  • 테라헤르쯔(terahertz: THz)파는 0.1~10 THz 의 범위로 적외선과 방송파 사이에 광대역 주파수 스펙트럼을 차지하고 있으며 직진성, 투과성, 그리고 낮은 에너지 (meV)를 가지고 있어 비 파괴적이고 무해한 장점을 지니고 있다. Ti:sapphire laser와 같은 femto-pulse source 등이 많은 발전이 되어 현재 많은 연구와 발전이 이루어지고 있다. femto-pulse source를 이용한 THz 응용에서는 높은 저항, 큰 전자 이동도, 그리고 아주 짧은 전하수명의 기판을 요구하는데 저온에서 성장한 (low-temperature grown : LT) GaAs는 격자 내에 Gallium 자리에 Arsenic이 치환 하면서 AsGa antisite가 발생하여 전하수명을 짧아지는 것을 응용하여 가장 많이 이용되고 있다. 현재 THz 응용분야에서 보다 작고 가격경쟁력이 있는 광통신을 이용한 THz photomixer등이 활발히 연구 하고 있다. 광섬유 내에서 손실과 분산이 최소값을 가지는 부분이 1.55 ${\mu}m$ 부근이고 In0.53Ga0.47As 기판을 이용하였을 때 여기에 완벽하게 만족하게 된다. 하지만 LT-InGaAs 의 경우 AsGa antisite로 인하여 carrier lifetime은 짧아지지만 높은 n-type 전하밀도를 가지게 된다. 이때 Be을 doping하여 전하밀도를 보상하여 높은 저항을 유지해야 하는데 Be의 활성화를 위해서는 열처리를 필요로 한다. 하지만 열처리를 하면 carrier lifetime이 길어지기 때문에 carrier lifetime과 저항을 적절히 조율해야 한다. 이는 물질자체의 특성이기 때문에 InGaAs는 GaAs보다 낮은 amplitude와 짧은 cut-off frequency를 가진다. 본 연구에서는 보다 높은 저항을 얻기 위하여 molecular beam epitaxy를 이용하여 semi-insulating InP:Fe 기판위에 격자 정합된 InGaAs:Be/InAlAs multi quantum well (MQW)를 온도별 ($250{\sim}400^{\circ}C$), 주기별 (50~150)로 성장을 하였고 이때 InGaAs layer의 Be doping level은 $2{\times}1018\;cm^{-3}$, Ex-situ annealing은 $550^{\circ}C$에서 10분으로 고정 하였다. THz 발생 실험에서는 InGaAs/InAlAs MQW은 4000 pA로 1,000 pA를 가지는 InGaAs epilayer보다 4배 높은 전류 신호를 얻을 수 있었고 모든 샘플이 2 THz에서 cut-off frequency를 가지고 있었다. THz 검출 실험에서는 LT-InGaAs:Be epilayer LT-InGaAs:Be/InAlAs, HT-InGaAs/InAlAs 샘플이 각각 180, 9000, 12000 pA의 전류신호를 가지고 있었고 모든 샘플이 2 THz에서 cut-off frequency를 가지고 있었다. HT-InGaAs/InAlAs MQW를 이용한 검출실험에서는 InGaAs layer가 defect free이지만 LT-InGaAs:Be/ InAlAs MQW 보다 높은 전류 신호를 얻을 수 있었다. 이는 InAlAs layer가 저항만 높이는 것뿐만 아니라 carrier trapping layer로써의 역할도 하는 것으로 사료된다.

  • PDF

Microstructure evolution and effect on deuterium retention in oxide dispersion strengthened tungsten during He+ irradiation

  • Ding, Xiao-Yu;Xu, Qiu;Zhu, Xiao-yong;Luo, Lai-Ma;Huang, Jian-Jun;Yu, Bin;Gao, Xiang;Li, Jian-Gang;Wu, Yu-Cheng
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2860-2866
    • /
    • 2020
  • Oxide dispersion-strengthened materials W-1wt%Pr2O3 and W-1wt%La2O3 were synthesized by wet chemical method and spark plasma sintering. The field emission scanning electron microscopy (FE-SEM) analysis, XRD and Vickers microhardness measurements were conducted to characterize the samples. The irradiations were carried out with a 5 keV helium ion beam to fluences up to 5.0 × 1021 ions/m2 under 600 ℃ using the low-energy ion irradiation system. Transmission electron microscopy (TEM) study was performed to investigate the microstructural evolution in W-1wt%Pr2O3 and W-1wt%La2O3. At 1.0 × 1020 He+/m2, the average loops size of the W-1wt%Pr2O3 was 4.3 nm, much lower than W-1wt% La2O3 of 8.5 nm. However, helium bubbles were not observed throughout in both doped W materials. The effects of pre-irradiation with 1.0 × 1021 He+/m2 on trapping of injected deuterium in doped W was studied by thermal desorption spectrometry (TDS) technique using quadrupole mass spectrometer. Compared with the samples without He+ pre-irradiation, deuterium (D) retention of doped W materials increased after He+ irradiation, whose retention was unsaturated at the damage level of 1.0 × 1022D2+/m2. The present results implied that irradiation effect of He+ ions must be taken into account to evaluate the deuterium retention in fusion material applications.

A Polarization-based Frequency Scanning Interferometer and the Measurement Processing Acceleration based on Parallel Programing (편광 기반 주파수 스캐닝 간섭 시스템 및 병렬 프로그래밍 기반 측정 고속화)

  • Lee, Seung Hyun;Kim, Min Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.253-263
    • /
    • 2013
  • Frequency Scanning Interferometry(FSI) system, one of the most promising optical surface measurement techniques, generally results in superior optical performance comparing with other 3-dimensional measuring methods as its hardware structure is fixed in operation and only the light frequency is scanned in a specific spectral band without vertical scanning of the target surface or the objective lens. FSI system collects a set of images of interference fringe by changing the frequency of light source. After that, it transforms intensity data of acquired image into frequency information, and calculates the height profile of target objects with the help of frequency analysis based on Fast Fourier Transform(FFT). However, it still suffers from optical noise on target surfaces and relatively long processing time due to the number of images acquired in frequency scanning phase. 1) a Polarization-based Frequency Scanning Interferometry(PFSI) is proposed for optical noise robustness. It consists of tunable laser for light source, ${\lambda}/4$ plate in front of reference mirror, ${\lambda}/4$ plate in front of target object, polarizing beam splitter, polarizer in front of image sensor, polarizer in front of the fiber coupled light source, ${\lambda}/2$ plate between PBS and polarizer of the light source. Using the proposed system, we can solve the problem of fringe image with low contrast by using polarization technique. Also, we can control light distribution of object beam and reference beam. 2) the signal processing acceleration method is proposed for PFSI, based on parallel processing architecture, which consists of parallel processing hardware and software such as Graphic Processing Unit(GPU) and Compute Unified Device Architecture(CUDA). As a result, the processing time reaches into tact time level of real-time processing. Finally, the proposed system is evaluated in terms of accuracy and processing speed through a series of experiment and the obtained results show the effectiveness of the proposed system and method.