• Title/Summary/Keyword: Low-LF

Search Result 266, Processing Time 0.028 seconds

INTRODUCTION OF NUC ALGORITHM IN ON-BOARD RELATIVE RADIOMERIC CALIBRATION OF KOMPSAT-2

  • Song, J.H.;Choi, M.J.;Seo, D.C.;Lee, D.H.;Lim, H.S.
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.504-507
    • /
    • 2007
  • The KOMPSAT-2 satellite is a push-broom system with MSC (Multi Spectral Camera) which contains a panchromatic band and four multi-spectral bands covering the spectral range from 450nm to 900nm. The PAN band is composed of six CCD array with 2528 pixels. And the MS band has one CCD array with 3792 pixels. Raw imagery generated from a push-broom sensor contains vertical streaks caused by variability in detector response, variability in lens falloff, pixel area, output amplifiers and especially electrical gain and offset. Relative radiometric calibration is necessary to account for the detector-to-detector non-uniformity in this raw imagery. Non-uniformity correction (NUC) is that the process of performing on-board relative correction of gain and offset for each pixel to improve data compressibility and to reduce banding and streaking from aggregation or re-sampling in the imagery. A relative gain and offset are calculated for each detector using scenes from uniform target area such as a large desert, forest, sea. In the NUC of KOMPSAT-2, The NUC table for each pixel are divided as HF NUC (high frequency NUC) and LF NUC (low frequency NUC) to apply to few restricted facts in the operating system ofKOMPSAT-2. This work presents the algorithm and process of NUC table generation and shows the imagery to compare with and without calibration.

  • PDF

Physiological Signal Analyses of Frictional Sound by Structural Parameters of Warp Knitted Fabrics

  • Cho Gilsoo;Kim Chunjeong;Cho Jayoung;Ha Jiyoung
    • Fibers and Polymers
    • /
    • v.6 no.1
    • /
    • pp.89-94
    • /
    • 2005
  • The purpose of this study is to offer acoustical database of warp knitted fabrics by investigating frictional sound properties and physiological responses according to structural parameters such as construction, lap form, and direction of mutual guide bar movement. Fabric sounds of seven warp knitted fabrics are recorded, and Zwicker's psychoacoustic param­eters - loudness(Z), sharpness(Z), roughness(Z), and fluctuation strength(Z) - are calculated. Also, physiological responses evoked by frictional sounds of warp knitted fabrics are measured such as electroencephalogram (EEG), the ratio of high fre­quency to low frequency (HF/LF), respiration rate (RESP), skin conductance level (SCL), and photoplethysmograph (PPG). In case of constructions, frictional sound of sharkskin having higher loudness(Z) and fluctuation strength(Z) increases RESP. By lap form, open lap has louder and larger fluctuating sound than closed lap, but there aren't significant difference of physi­ological responses between open lap and closed lap. In direction of mutual guide bar movement, parallel direction evokes bigger changes of beta wave than counter direction because of its loud, rough, and fluctuating sound. Fluctuation strength(Z) and roughness(Z) are defined as important factors for predicting physiological responses in construction and mutual guide bar movement, respectively.

A Novel Three Phase Series-Parallel Resonant Converter Fed DC-Drive System

  • Daigavane, Manoj;Suryawanshi, Hiralal;Khan, Jawed
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.222-232
    • /
    • 2007
  • This paper presents the application of a single phase AC-to-DC converter using a three-phase series parallel (SPRC) resonant converter to variable speed dc-drive. The improved power quality converter gives the input power factor unity over a wide speed range, reduces the total harmonic distortion (THD) of ac input supply current, and makes very low ripples in the armature current and voltage waveform. This soft-switching converter not only possesses the advantages of achieving high switching frequencies with practically zero switching losses but also provides full ranges of voltage conversion and load variation. The proposed drive system is the most appropriate solution to preserve the present separately excited de motors in industry compared with the use of variable frequency ac drive technology. The simulation and experimental results are presented for variable load torque conditions. The variable frequency control scheme is implemented using a DSP- TMS320LF2402. This control reduces the switching losses and current ripples, eliminates the EMI and improves the efficiency of the drive system. Experimental results confirm the consistency of the proposed approach.

Nonlinear Correlation Dimension Analysis of EEG and HRV (뇌파의 상관차원과 HRV의 상관분석)

  • Kim, Jung-Gyun;Park, Young-Bae;Park, Young-Jae;Kim, Min-Yong
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.2
    • /
    • pp.84-95
    • /
    • 2007
  • Background and Purpose: We have studied the trends of EEG signals in the voluntary breathing condition by applying the fractal analysis. According to chaos theory, irregularity of EEG signals can result from low dimensional deterministic chaos. A principal parameter to quantify the degree of Chaotic nonlinear dynamics is correlation dimension. The aim of this study was to analyze correlation between the correlation dimension of EEG and HRV(heart rate variability). We have studied the trends of EEG signals in the voluntary breathing condition by applying the fractal analysis. Methods: EEG raw data were measured by moving windows during 15 minutes. Then, the correlation dimension(D2) was calculated by each 40-seconds-segment in 15 minutes data, totally 36 segments. 8 channels EEG study on the Fp, F, T, P was carried out in 30 subjects. Results and Conclusion: Correlation analysis of HRV was calculated with deterministic non-linear data and stochastic non-linear data. 1. Ch1(Fp1), Ch4(F3), Ch4(F4) is positive correlated with In LF. 2. Ch1(Fp1), Ch3(F3) is positive correlated with In TF.

  • PDF

The Ka-band Low Noise and Stable Receiver Design of Digital Correlation Radiometer for High Spatial Resolution

  • Choi, Jun-Ho;Kim, Sung-Hyun;Kang, Gum-Sil;Park, Hyuk;Choi, Seh-Wan;Jiang, Jing-Shan;Kim, Yong-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.297-302
    • /
    • 2002
  • The subsystems of two channel correlation radiometer such as RF front-end, IF and LF unit, LO unit, software based I/Q demodulator and complex correlator are characterized and their performance is analyzed in this paper. The limited hardware calibration method and receiver design consideration are discussed. The receiver architecture of 37GHz correlation radiometer is integrated. The designed radiometer employs a single-sideband superheterodyne receiver. The center frequency of the radiometer is 37 GHz and IF center frequency is 1.95 GHz with the equivalent noise bandwidth of 79.6 MHz. The receiver has less than 4.2 dB noise figure which is calculated by the Y-factor method and its gain can be adjusted from 60 dB to 80 dB.

  • PDF

A Study on Characters of Heart Rate Variability in Postpartum Disease Patients (산후풍 환자의 심박변이도 특성 관찰 연구)

  • Hwang, Deok-Sang;Lee, Chang-Hoon;Lee, Kyung-Sub;Lee, Yoon-Jae
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.20 no.3
    • /
    • pp.178-184
    • /
    • 2007
  • Purpose: During postpartum period, many women complain multiple pain, sweating, cold hypersensitivity, abdominal pain, hot flush and so on. We called the postpartum disease as San Hu Pung. The San Hu Pung could related with dysautonomia. So we studied the character of the postpartum disease patients as heart rate variability(H.R.V) Methods: The subjects were 63 women who visited Kangnam Kyunghee hospital for postpartum management from February 2006 to June 2007. From history taking, 42 symptomatic women was divided at the postpartum disease group, 21 asymptomatic women was divided at the control group. All women was measured HRV, we studied the difference of HRV between two group. Results: Compared with the control group, SDNN of the disease group was significant low. TP, LF and HF of the disease group were significantly lower than the control group. Conclusion: The difference of HRV between the disease group and the control group was significant. The results of HRV on the disease group could mean that San hu pung is related dysautonomia. The more studies to diagnose San hu pung would be needed.

  • PDF

Verification of Effectiveness of Wearing Compression Pants in Wearable Robot Based on Bio-signals (생체신호에 기반한 웨어러블 로봇 내 부분 압박 바지 착용 시 효과 검증)

  • Park, Soyoung;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.2
    • /
    • pp.305-316
    • /
    • 2021
  • In this study, the effect of wearing functional compression pants is verified using a lower-limb wearable robot through a bio-signal analysis and subjective fit evaluation. First, the compression area to be applied to the functional compression pants is derived using the quad method for nine men in their 20s. Subsequently, functional compression pants are prepared, and changes in Electroencephalogram (EEG) and Electrocardiogram (ECG) signals when wearing the functional compression and normal regular pants inside a wearable robot are measured. The EEG and ECG signals are measured with eyes closed and open. Results indicate that the Relative alpha (RA) and Relative gamma wave (RG) of the EEG signal differ significantly, resulting in increased stability and reduced anxiety and stress when wearing the functional compression pants. Furthermore, the ECG analysis results indicate statistically significant differences in the Low frequency (LF)/High frequency (HF) index, which reflect the overall balance of the autonomic nervous system and can be interpreted as feeling comfortable and balanced when wearing the functional compression pants. Moreover, subjective sense is discovered to be effective in assessing wear fit, ease of movement, skin friction, and wear comfort when wearing the functional compression pants.

State of the Art on Terrestrial Radionavigation System and Its Applications for Maritime PNT Service

  • Seo, Kiyeol;Fang, Tae Hyun;Park, Sang Hyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.11 no.4
    • /
    • pp.229-238
    • /
    • 2022
  • This paper addresses on the International technical trends, standards, and development status of terrestrial radionavigation system to provide more accurate and fail-safe Positioning, Navigation, and Timing (PNT) Information available in maritime navigation environment. We analyze the performance result of pilot service in enhanced Long range navigation (eLoran) testbed environment using Low Frequency (LF) signal, and describe the development status of Ranging-Mode (R-Mode) system using Medium Frequency (MF) and Very High Frequency (VHF) to meet the Harbor Entrances and Approaches (HEA) requirement of International Maritime Organization (IMO) within 10m position accuracy. Furthermore, we present an architecture for integrated service of satellite-terrestrial navigation system and future maritime applicable fields. As the core information infrastructure of future navigation for 4th industrial revolution, this paper will be contributed to determining the direction of present and future to provide fail-safe PNT service with Global Navigation Satellite System (GNSS) based on the technical enhancement of terrestrial integrated navigation system.

Study on the Radial Pulse Wave Variables and Heart Rate Variability after Acupuncture Stimulation (침자극이 좌관맥상과 심박수 미세변화에 미치는 영향)

  • Won, Jae-Kyun;Jung, Soon-Kwan;Kim, Dong-Eun;Lim, Jin-Young;Kwon, Young-Dal;Yeom, Seung-Ryong;Lee, Su-Kyung;Song, Yung-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.237-244
    • /
    • 2009
  • We investigated the effects of acupuncture stimulation on pulse wave variables and heart rate variability (HRV) in healthy adults. To evaluate twenty healthy volunteers (10 men, 10 women) had acupuncture into both Hapkok (Ll4) and Taechung (Liv3) for 15 minutes. Radial pulse, Heart Rate Variability, body temperature and blood pressure were checked before and after acupuncture to evaluate Pulse Wave Variability and Autonomous Function. The results were as follows; Heart rate was significantly increased while systolic blood pressure (mmHg) and diastolic blood pressure (mmHg) were significantly increased after acupuncture treatment. Sixteen subjects didn't change representative pulse wave variables after acupuncture treatment. Energy, height of main peak (H1), height of pre-dicrotic valley (H2) and height of descending valley (H4) were decreased while height of dicrotic peak (H5) was significantly decreased after acupuncture treatment. Time to main peak (T1), time to pre-dicrotic valley (T2), time to dicrotic peak (T5), total time (T) and T-T4 were decreased while time to descending valley (T4) was increased after acupuncture treatment. Total area (At), area of main peak (Aw) and ratio of diastolic period area (Ad) were decreased while ratio of systolic period area (As) and angle of main peak (MPA) were increased after acupuncture treatment. The standard deviation of all normal RR intervals (SDNN) was increased while the root mean square of successive differences between the normal heart beats (RMSSD) was significantly increased after acupuncture treatment by time domain analysis. Low frequency power (LF) and LF/HF ratio were decreased while high frequency power (HF) was significantly increased after acupuncture treatment by frequency domain analysis. This study suggests that acupuncture treatment changes pulse wave variability and heart rate variability. Further study on various acupuncture treatment for pulse wave variability and heart rate variability is required.

Impedance Parameters of Electrical Double Layer I. A Determination Method of Electrolytic Cell Impedance Parameter on the Platinum Electrode (전기이중층의 임피던스 파라미터 I. 백금전극을 사용한 전해쎌 임피던스 파라미터의 결정방법)

  • Kum-Sho Hwang;Un-Sik Kim
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.3
    • /
    • pp.273-281
    • /
    • 1986
  • This study is focused on the correct measurement of the equations for the determination of the impedance parameters-the differential capacity of the double layer $C_d$, solution resistance $R_Q$, transfer resitance $R_i$, and adsorption pseudcapacity $C_{\phi}$/ The application of only an imaginary part of complex function of ${\omega}$ at the sinusoidal steady state indicates the following equations of total impedance: at low frequency $|Z_{LF}|=1/{\omega}_1\;C_{\phi}\;{\sqrt{1+{{\omega}_1}^2/{\omega}^2}$, at high frequency $|Z_{HF}|={\omega}_2/({\omega}_1{\omega}_3C{\phi})({\omega}^2+{{\omega}_2}^2)\;{\sqrt{{({\omega}^2+{\omega}_2{\omega}_3)}^2+{({\omega}_2{\omega}-{\omega_3{\omega})^2}}$. The values of the total impedance of cell, phase angle, and cell current that are necessary for the calculations of impedance parameters were experimentally measured from 200 to 6000Hz for the following supporting electrolytes, 0.5M $Na_2SO_4$, 1M NaCl, 19.373% sea water, 1M HCl, 1M $KNO_3$ and for $10^{-2}M$ KI and 60mM DBNA (Di-iso-Butylnitrosoamine) in these supporting electrolytes. The derived equations in this study shows that the values of impedance parameters of $C_d,\;C_{\phi},\;R_i\;and\;R_Q\;are\;15{\sim}40\;{\mu}F/cm^2,\;162{\sim}758\;{\mu}F/cm^2\;11.5{\sim}57.6\;ohm{\cdot}cm^2\;and\;0.5{\times}10^{-2}{\sim}4.1{\times}10^{-2}\;ohm{\cdot}cm^2$ respectively.

  • PDF