• Title/Summary/Keyword: Low temperature environment

Search Result 1,818, Processing Time 0.029 seconds

Establishment of Low Temperature Environment System Using Polar Environment Performance Test Construction (극지환경성능시험설비를 활용한 저온환경 시스템 구축)

  • Sung, Ki-Young;Han, Seong-Jong;Lee, Jung-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.843-851
    • /
    • 2022
  • This paper was conducted to study the conditions for the manufacture and operation of artificial snow removal and ice-making test facilities so that the test equipment can be tested in a low-temperature environment using the polar environment performance test facility. The polar environment performance test Facility is designed to artificially simulate extreme environments up to -65 ℃, and is a mid-to-large low-temperature environment test facility that can perform performance tests on offshore plant equipment, ships, leisure, and offshore structures. To verify the safety of deck work of ships operating in polar environments, artificial snow removal and artificial ice making devices were manufactured, and we conducted research on various operating environments using these facilities. For the efficient operation of artificial snow and ice making facilities, it is important to continuously supply dry air, and it has been found that installing an additional heater at the tip of the nozzle is effective in preventing freezing.

Growth Responses and Regrowth to Low Temperature of Nine Native Moss Species

  • Gong, Gyeong Yeop;Jeong, Kyeong Jin;Lee, Sang Woo;Yun, Jae Gill
    • Journal of People, Plants, and Environment
    • /
    • v.22 no.6
    • /
    • pp.575-582
    • /
    • 2019
  • Moss is used as an important material in indoor landscaping as well as outdoor landscaping. Moss is vivid green during growth and excellent in ornamental value. But when temperature drops, moss stops growth, turns brown or loses its ornamental value. In the present experiment, for the purpose of classifying native mosses according to the growth response to low temperature, the temperature of the plant growth chamber was set to 15℃/5℃ (16h/8h, day/night) and 5℃ (24h) for 8 weeks using nine native moss species. Thereafter, the temperature of the plant growth chamber was set to 20℃, and then the changes of moss block area and moss color were measured. The changes of moss block area and moss color were measured using a Photoshop program, after each moss block was photographed. As a result, Atrichum undulatum (Hedw.). Beauv., Etodon luridus (Griff.) A. Jaeger, Bachythecium plumosum (Hedw.) Schimp, Plagiomnium cuspidatum (Hedw.) T.J. Kop, and Hypnum plumaeforme Wilson showed a small decrease in moss block area at low temperature, and their recovery were the fastest at 20℃. These three species had higher green values at low temperature compared to other species, and the greenness increased rapidly at 20℃. On the other hand, Atrichum undulatum (Hedw.). Beauv., Marchantia polymorpha L., and Thuidium cymbifolium (Mitt.) A. Jaeger showed the smallest block area at low temperature and the lowest recovery even at 20℃. Their green values also decreased significantly at low temperature, and maintained low green value even at 20℃. These results showed that these three moss species are sensitive to low temperature. The remaining Myuroclada maximowiczii, Plagiomnium cuspidatum, and H. erectiusculum showed moderate responses to low temperature compared to other six species of mosses.

Changes in the body temperature of Proprioceptive activity by external stimulation

  • Kim, Eun-Sung;Park, Chang-Ho
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.827-831
    • /
    • 2005
  • Acupuncture and Low-frequency-wave stimulation at the Points (LI4, LI6, LI8 and LI11) on the large intestine meridian of hand resulted in same pattern about body temperature profiles with time. Upon 4Hz and 50Hz stimulation the temperature profiles on LI6 and LI11 were declined probably because of their relationship with Proprioceptive activity. Temperature different at the points was higher when the intensity of low-frequency-wave stimulation was stronger.

  • PDF

A Study on Thermal Comfort of Korea Men감s Wear in Summer - Based on Indoor Environment conditions - (하계 남성복의 온열쾌적감에 관한 연구 - 실내 환경조건을 중심으로 -)

  • 정상열;고경태
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1997.10a
    • /
    • pp.364-368
    • /
    • 1997
  • The purpose of this Study was to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate Variability(HRV), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at 50% R.H., 24C, and the difference of skin temperature was found at the calf area as air temperature changes. At low air temperature and low humidity, heart rate was decreased, but there was no change at brain wave, keeping a-wave.

  • PDF

An Experiment on Lighting Environment for some Behavior in Housing (주택에서의 각 생활행위에 대응하는 조명환경에 관한 실험연구)

  • Lee Sun-Young
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.65-71
    • /
    • 2005
  • The present study performed subjective evaluation experiments using slides and scale down models in order to propose guidelines for lighting environment desirable for each behavior in the house. The evaluation measure was composed of 20 mood items and 15 behavior items. As for experiment methods, the slide experiment used SD method, and the scale down model experiment used Scheffe's paired comparison. The results of this study are as follows. 1) Desirable lighting environment for working and talking is active atmosphere. 2) Lighting environment desirable far relaxation is to heighten lighting contrast using candescent lamps and local lights. In other words, active atmosphere, which is desirable for working and talking, is not desirable for relaxation. 3) Lighting for working requires bright illuminance and high color temperature(6000k). 4) Lighting for relaxation requires somewhat low brightness regardless of color temperature. If the light is bright it is better to use lamps of low color temperature. 5) for conversation, bright illuminance is more desirable than dark one, and the most adequate color temperature is 4000K.

A Basic Study on Burr Formation of Micro Cutting Process with the Ferrous Metal at tow Temperature (철계 금속 마이크로 절삭 가공시 저온 환경에서의 버 발생에 관한 기초연구)

  • Kim, G.H.;Kim, D.J.;Sohn, J.I.;Yoon, G.S.;Heo, Y.M.;Cho, M.W.
    • Transactions of Materials Processing
    • /
    • v.18 no.2
    • /
    • pp.166-171
    • /
    • 2009
  • In this paper, a basic study on micro cutting process with SM20C at low temperature environment was performed. In macro cutting fields, the cryogenic cutting process has been applied to cut the refractory metal but, the serious problem may be generated in micro cutting fields by the cryogenic environment. However, if the proper low temperature is applied to micro cutting area, the cooling effect of cutting heat is expected. Such effect can make the reduction of tool wear and burr formation. For verifying this possibility, the micro cutting experiment at low temperature was performed and SEM images were analyzed.

Experimental Study on a Low-Temperature Hot Water Capillary Radiant Floor Heating System (저온온수 모세유관 바닥복사 난방시스템의 성능에 관한 실험적 연구)

  • Cho, Jinkyun;Park, Beungyong;Lee, Yongjun;Chong, Wonho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.2
    • /
    • pp.68-82
    • /
    • 2018
  • Radiant floor heating systems with capillary tubes are energy saving systems in which hot water is circulated into capillary tube with a small diameter. In this study, the heating performance of capillary tube system is investigated in an experimental study and a simulation model. The results of the study showed that, the capillary tube radiant floor heating system maintains a more stable floor surface temperature in comparison a PB pipe system. In terms of energy consumption, the capillary tube radiant floor heating system proved to be more efficient than the PB pipe heating system at $40^{\circ}C$ of low temperature hot water supply. The difference between water temperature and room temperature can be held low for heating which saves energy. Low temperature radiant floor heating system with capillary tubes have significant advantages such as health improvement, low energy cost, optimum use of heat source(boiler) and higher operational efficiency.

A Study on the Fatigue Crack Propagation Characteristics for SUP9 Steel at Low Temperature (SUP9강의 저온피로크랙 전파특성에 관한 연구)

  • 박경동;박상오
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.5
    • /
    • pp.80-87
    • /
    • 2002
  • In this study, CT specimens were prepared from spring steel(SUP9) which was used in suspension of automobile for room temperature and low temperature service. We got the following characteristics from fatigue crack growth test carried out in the environment of room temperature and low temperature at $25^{\circ}C$, ­3$0^{\circ}C$, ­5$0^{\circ}C$, ­7$0^{\circ}C$ and ­10$0^{\circ}C$ in the range of stress ratio of 0.05 by means of opening mode displacement. The threshold stress intensity factor range ΔKth in the early stage of fatigue crack growth (Region I) and stress intensity factor range ΔK in the stable of fatigue crack growth (Region II) was decreased in proportion to descend temperature. It is assumed that the fatigue resistance characteristics and fracture strength at low temperature and high temperature is considerable higher than that of room temperature in the early stage and stable of fatigue crack growth region.

Effects of Resistivity Variation in a Very Low Temperature on the Characteristics of Induction Motors

  • Kim, Beom Jin;Kim, Jin Sung;Park, Gwan Soo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • This paper presents design of induction motor in very low temperature for LNG main cargo pump and comparison of two motors. One is the motor for using in room temperature and another is the motor for using very low temperature. This paper designs with Equivalent circuit Method and uses Finite Element Method to analysis. The motor for very low temperature considers variation of coil resistivity due to temperature change and compare torque characteristic with the motor for room temperature. Design element of motor for very low temperature considers resistivity variation following temperature change on going through this paper. The result shows that two types of motors are almost same torque curve characteristic even though they are not the same environment.

Properties of Recycled Board Made of Disused Wooden Furniture Carbonized at Low Temperature (저온탄화처리 폐가구재로 제조한 재생보드의 물성)

  • Seo, In-Su;Lee, Min-Gyoung;Lee, Hwa-Hyoung;Kang, Ho-Yang
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • This study was carried for recycling laminated PB and MDF of disused furniture. PB and MDF particles taken from disused furniture were heat-treated at $250^{\circ}C$ and four levels of treatment time, 2, 4, 6 and 8 hours. The recycled boards were made with heat-treated particles after milling and screening with 100 mesh. The bending strength of the recycled boards were lower than that of virgin boards while their anti-swelling efficiency were much improved. Their formaldehyde emissivity were very low. Thus it was concluded that the recylcled boards are prospective environment-friendly material for interial consturction.

  • PDF