• 제목/요약/키워드: Low profile plate

검색결과 31건 처리시간 0.017초

제 1열 전족부 절골술을 통한 평발 교정에 있어 골이식 없이 사용한 소형 쐐기형 금속판의 치료 결과 (The Results of the First Ray Forefoot Osteotomy Using Low Profile Wedge Plate without a Bone Grafting for Pes Planus Correction)

  • 최준영;신명진;서진수
    • 대한족부족관절학회지
    • /
    • 제21권1호
    • /
    • pp.7-11
    • /
    • 2017
  • Purpose: We retrospectively analyzed the radiographic and clinical results after the first ray of forefoot osteotomy using low profile wedge plate without additional cancellous bone grafting for pes planus correction. Materials and Methods: Twenty-four patients were enrolled in this study. Medial cuneiform opening wedge osteotomy was performed in 12 patients (Cotton osteotomy, group C) and first metatarsal base osteotomy was performed in 12 patients (group MT). Results: On average, the wedge size was 5.61 mm (5~6 mm). The mean time to radiographic union was 3.18 and 3.27 months in groups C and MT, respectively. Postoperative talonavicular coverage angle, talo-first metatarsal angle (anteroposterior), talo-first metatarsal angle (lateral), talo-calcaneal angle (lateral), medial cuneiform height, and American orthopaedic foot, as well as ankle society midfoot scale were significantly improved in both groups. Nonunion, delayed union or fixation failure was not presented in our series. Conclusion: We have shown that low profile wedge plate was effective in the case of first ray forefoot osteotomy for pes planus correction without any additional cancellous bone grafting.

무지외반증에서 저상형 금속판 고정을 이용한 근위 개방형 절골술의 임상적 결과: 근위 갈매기형 절골술 후 K-강선 고정술과의 비교 (The Clinical Results of the Proximal Opening Wedge Osteotomy Using a Low Profile Plate in Hallux Valgus: Comparison with Proximal Chevron Osteotomy Fixed with K-wires)

  • 서은석;방태정;전숙하
    • 대한족부족관절학회지
    • /
    • 제17권4호
    • /
    • pp.302-308
    • /
    • 2013
  • Purpose: To present clinical results of proximal first metatarsal opening wedge osteotomy and low profile plate fixation in hallux valgus deformity. Materials and Methods: Thirty-two patients (39 feet) underwent surgery for hallux valgus deformity. Fourteen patients (18 feet; Group A) underwent proximal first metatarsal opening wedge osteotomy fixed with low profile titanium plate ($Arthrex^{(R)}$), and 18 patients (21 feet; Group B) underwent proximal chevron osteotomy with two K-wires. Improvement in hallux valgus angle (HVA), 1, 2 intermetatarsal angle (IMA), range of motion of 1st metatarsophalangeal joint, VAS score, and the length of first metatarsal on weight-bearing radiograph were evaluated preoperatively and at final follow-up. Results: HVA improved from $36.2{\pm}6.6$ degrees to $11.7{\pm}5.1$ degrees, and 1, 2 IMA improved from $15.7{\pm}2.6$ degrees to $7.2{\pm}1.9$ degrees. VAS score improved from $7.2{\pm}1.2$ to $1.4{\pm}0.9$. There were no significant differences clinically and radiologically. Conclusion: Proximal first metatarsal opening wedge osteotomy with stable fixation using low profile plate may be an effective surgical option for correction of hallux valgus deformity.

압출성형을 이용한 플라스틱 방음벽 구조물 제작 연구 (Manufacturing of Plastic Noise Barrier Structure Using Extrusion Molding)

  • 김형국
    • 한국기계가공학회지
    • /
    • 제20권6호
    • /
    • pp.76-81
    • /
    • 2021
  • A plastic noise barrier is a structure installed to minimize noise, and it is composed of the main plate, sound-absorbing plate, and sound-absorbing material. Plastic noise barrier structures have several advantages compared to other products, such as light weight, anticorrosion, durability, easy assembly, rapid construction, and low costs. In this study, the main and sound-absorbing plates were manufactured through extrusion molding, and the sound-absorbing plate was finished with a press to improve the conventional injection molding. Extrusion molding dies and punch dies were designed, and a profile extrusion-molding system was developed. Thus, inexpensive and efficient sound-absorbing and main plates can be produced, and the noise barrier structure can be assembled rapidly. Additionally, a noise barrier structure with extended service life and excellent quality can be constructed by creating uniform free space to accommodate increased temperatures after assembly and installation.

소형화 및 슬림형에 적합한 평면 플라이백 변압기의 최적 설계에 관한 연구 (A Study on the Optimal Design of Planar Flyback Transformers suitable for Small-size and Low-profile)

  • 나혜중;김종해
    • 전기전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.828-837
    • /
    • 2020
  • 본 논문에서는 10W급 Tablet용 AC to DC Adapter의 소형화 및 슬림형에 적합한 평면 Flyback 변압기 최적화 설계에 대해서 나타낸다. 또한 본 논문에서는 수동권선의 기존 양산 Flyback 변압기에 비해 자동권선, Trans 크기 저감 및 누설 인덕턴스(Lk) 저감이 가능한 Hybrid형 사출 권선 변압기와 Drum형 사출 권선 변압기를 제안한다. 특히 본 논문에서 제안한 Drum형 사출 권선 변압기는 Hybrid형 사출 권선 변압기 2차측의 동판 사출 권선 접속 문제를 해결하기 위하여 변압기를 수평으로 눕힌 형태로 구성하였다. 본 논문에서 제안한 Hybrid형 사출 권선 변압기와 Drum형 사출 권선 변압기의 1차측과 2차측 권선은 각각 기존 권선과 동판 사출 권선을 사용하였다. 본 논문에서 제안한 Hybrid형 사출 권선 변압기와 Drum형 사출권선 변압기에 대해 Maxwell 2D 및 3D Tool을 이용하여 소형화 및 슬림형에 적합한 평면 Flyback 변압기 최적화 설계를 수행하였다.

소형 금속판의 골수강 내 고정을 통한 최소 침습적 무지 외반증 교정 수술: 증례 보고 (Minimally Invasive Surgery for Hallux Valgus Deformity Using Intramedullary Low Profile Plate Fixation: A Case Report)

  • 조성탄;서진수;최준영
    • 대한족부족관절학회지
    • /
    • 제23권3호
    • /
    • pp.135-138
    • /
    • 2019
  • According to a recent systemic review, hallux valgus deformity has a prevalence rate of about 23% among adults aged 18 to 65 years. To date, more than 100 operative methods have been reported for the correction of hallux valgus deformity. For young female with mild to moderate hallux valgus deformity, minimally invasive surgery can be considered for aesthetic demands. Here, we report a case of a young female patient with mild hallux valgus deformity treated by minimally invasive surgery using intramedullary low profile plate fixation. This can be the favorable method for secure fixation of the osteotomy site and prevention of medial skin irritation symptoms derived from a sharp osteotomy margin.

Feasibility study of wide-band low-profile ultrasonic sensor with flexible piezoelectric paint

  • Li, Xin;Zhang, Yunfeng
    • Smart Structures and Systems
    • /
    • 제4권5호
    • /
    • pp.565-582
    • /
    • 2008
  • This paper presents a feasibility study of flexible piezoelectric paint for use in wide-band low-profile surface-mount or embeddable ultrasonic sensor for in situ structural health monitoring. Piezoelectric paint is a piezoelectric composite with 0-3 connectivity. Because of its ease of application, piezoelectric paint can be readily fabricated into sensing element with complex pattern. This study examines the characteristics of piezoelectric paint in acoustic emission signal and ultrasonic guided wave sensing. A series of ultrasonic tests including pitch catch and pencil break tests were performed to validate the ultrasonic wave sensing capability of piezoelectric paint. The results of finite element simulation of ultrasonic wave propagation, and acoustic emission generated by a pencil lead break on an aluminum plate are also presented in this paper along with corresponding experimental data. Based on the preliminary experimental results, the piezoelectric paint appears to offer a promising sensing material for use in real-time monitoring of crack initiation and propagation in both metallic and composite structures.

사각형 유도 결합 플라즈마 시스템의 수치 모델링 (Numerical Modeling of a Rectangular Type Inductively Coupled Plasma System)

  • 주정훈
    • 한국표면공학회지
    • /
    • 제45권4호
    • /
    • pp.174-180
    • /
    • 2012
  • Low pressure inductively coupled plasma characteristics of argon and oxygen are numerically simulated for a 400 mm rectangular type system with a plasma fluid model. The results showed lower power absorption profile at the corner than a circular one in a 13.56 MHz driven 1.5 turn antenna system with a drift-diffusion and quasi-neutrality assumption. Ions controlled by electric field are more non-uniform than metastables and the power absorption profile of oxygen plasma is affected by horizontal gas flow pattern to show 25% lower power absorption at the pumping flange side. Oxygen negative ions which are generated in electron collisional dissociation of oxygen molecules was calculated as 0.1% of oxygen atoms with similar spatial profile.

PTC와 평판형 태양열집열기의 성능평가 비교 연구 (The Comparative Study on Performance of PTC and Flat-plate Solar Collector)

  • 김인환;허남수;김만석;이정언
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.28-33
    • /
    • 2010
  • Solar collectors to be applied are mainly flat-plate or vacuum tube collector which is used for hot water supply of house because of low heat value and low temperature. There are a necessity to expand applicable scope of solar collector into the industrial process heat source and air conditioner for coping with renewable energy policy of government and industrial trend. This study is to analysis the performance of PTC solar collector of concentrating type and flat-plate of non-concentrating. For this, temperature difference and heating value as insolation of air outside is measured from these two collectors mounted on 2-axial solar tracking system. It is investigated that temperature profile obtained from PTC solar collector is uniform and collecting heat per unit area is 6.8kcal/$m^2$ min which is about 3 times with compare to flat-plate collector of 2kcal/$m^2$min. Also the amount of heat to be produced from PTC solar collector is 3 Mcal/$m^2$ which is about 2 times with compare to flat-plate collector of 1.5Mcal/$m^2$ as a result of operating these two collectors during one month. Therefore, it is obtained that heat collecting performance of PTC solar collector is superior to flat-plate.

2차유동이 평판후류의 난류열전달에 미치는 영향 (Effects of the secondary flow on the turbulent heat transfer of a flat plate wake)

  • 김형수;이준식;강신형
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.417-427
    • /
    • 1998
  • The effect of secondary flow on the heat transfer of a turbulent wake generated by a flat plate was experimentally investigated. The secondary flow was induced in a curved duct in which the flat plate wake generator was installed. All three components of turbulent heat flux were measured in the plane containing the mean radius of curvature of the curved duct. The results showed that mean temperature profiles deviate from the similarity of the straight wake because of the cold fluid transported from the free-stream. The half-width of the mean temperature profile increased rapidly by upwash motion of the secondary flow. The changes to turbulence structure caused by the secondary flow show more pronounced effect on heat transport than on momentum transport. This is because the response to the variation of flow conditions is delayed in temperature field. Negative production of the turbulent heat flux is observed in the inner wake region. From the conditional averaging, it has been found that the negative production of the turbulent heat flux is generated due to a mixing process between the hot and low momentum eddies occupied in the inner wake region and the cold and high momentum eddies in the potential region.

수소가스 감지용 가연성 가스센서 제작을 위한 요소기술 개발 (Development of Core Technologies for Integrating Combustible Hydrogen Gas Sensor)

  • 윤의중;박형식;이석태;박노경
    • 한국전기전자재료학회논문지
    • /
    • 제20권3호
    • /
    • pp.228-233
    • /
    • 2007
  • Core technologies for integrating hydrogen gas sensor were investigated. In this study, the thermally isolated micro-hot-plate with areas of $100{\times}100-260{\times}260{\mu}m^2$ was fabricated by utilizing surface micromachining technique that provides better manufacturing yield than bulk micromachining counterpart. The optimum design of the sensor was peformed by analyzing the thermal profile of the structure obtained from a ANSYS simulator. The 400-nm-thick polysilicon films doped with phosphorus, the 300-nm-thick aluminum films, and the 200-nm-thick $SnO_2$(or ZnO)films were used as the micro-heater material, the temperature sensor material, and the gas sensitive material, respectively. The experimental results show that the developed gas sensors can detect $H_2$ concentration as low as 1 ppm.