• 제목/요약/키워드: Low load operation

검색결과 474건 처리시간 0.027초

불평형 부하 운전시 3상 유도발전기 특성 해석 (Characteristics Analysis of 3-phase Induction Generator at the Unbalanced Load Operation)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제56권3호
    • /
    • pp.123-128
    • /
    • 2007
  • Hydro power supplies no pollution energy, mainly induction generator has been applied at the small capacity power station. The generating power of small hydro-electric power station connects on the 22.9kV distribution system or low voltage system in the case of three-phase four-wire supply system. There are side effects of various kinds in the 3-three phase 4-wire distribution system mixing 1-phase load and 3-phase load. This system generates the voltage unbalance by unbalanced load operating condition. They have various serious effects on generator and connection system. In this paper, we analyzed what kind of operation characteristic are happened in the induction generator by customer load variation at the 3-three phase 4-wire distribution system.

승용차의 부분부하제어를 위한 스크류형 과급기 개발 (Development of a Screw Type Super-Charger for Part Load Control of Passenger Car)

  • 배재일;배신철
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1427-1434
    • /
    • 2003
  • Turbo- or Super-charging has been used to boost engine power for Gasoline- and Diesel Engine since beginning of 20th century. So far turbo-charger has enjoyed a high reputation in the charging field for its technical advantages such as no demand of operation power from engine and an excellent charging effect in a static operation at mid- and high engine speed. A mechanically driven super-charger, however, is now popular due to the high engine power at quick change of the driving mode - high engine torque even at low engine speed. Since super-charger needs operation power from engine, it is difficult to improve its relatively higher fuel consumption than that of turbo-charger. This negative point is still an obstacle to the wide use of supercharger. Super-charger using screw-type compressor will fulfill the purpose to reduce fuel consumption by minimizing operation power owing to no charge at idling or part load driving condition. This study aims to develop power control concept to achieve the minimization of operation power. A screw type super-charger was modified in design partially and installed with an internal bypass valve and a bypass tube to control charging pressure at part load. The various control concepts show a possibility to reduce operation power of super-charger.

LOW FUEL CONSUMPTION AND LOW EMISSIONS - ELECTROMECHANICAL VALVE TRAIN IN VEHICLE OPERATION

  • Pischinger, M.;Salber, W.;Staay, F.V.D.;Baumgarten, H.;Kemper, H.
    • International Journal of Automotive Technology
    • /
    • 제1권1호
    • /
    • pp.17-25
    • /
    • 2000
  • The electromechanical valve train (EMV) technology allows for a reduction in fuel consumption while operating under a stoichiometric air-fuel-ratio and preserves the ability to use conventional exhaust gas aftertreatment technology with a 3-way-catalyst. Compared with an engine with a camshaft-driven valve train, the variable valve timing concept makes possible an additional optimization of cold start, warm-up and transient operation. In contrast with the conventionally throttled engine, optimized control of load and in-cylinder gas movement can be used for each individual cylinder and engine cycle. A load control strategy using a "Late Intake Valve Open" (LIO) provides a reduction in start-up HC emissions of approximately 60%. Due to reduced wall-wetting, the LIO control strategy improves the transition from start to idle. "Late Exhaust Valve Open" (LEO) timing during the exhaust stroke leads to exhaust gas afterburning and, thereby, results in high exhaust gas temperatures and low HC emissions. Vehicle investigations have demonstrated an improved accuracy of the air-fuel-ratio during transient operation. Results in the New European Driving Cycle have confirmed a reduction in fuel consumption of more than 15% while meeting EURO IV emission limits.

  • PDF

대기전력저감을 위한 플라이백컨버터 (A Novel Flyback Converter for Low Standby Power Consumption)

  • 정봉근;장상호;김은수;최문기;계문호
    • 전력전자학회논문지
    • /
    • 제14권4호
    • /
    • pp.299-306
    • /
    • 2009
  • 최근 대기전력저감기능을 갖는 PWM IC를 적용한 플라이백 컨버터는 대기전력 모드 시 Burst 스위칭 동작에 의해 전력소모를 최소화 할 수 있지만 경 부하 및 대기전력모드 시 변압기를 통해 흐르는 큰 자화전류에 의해 여전히 낮은 효율특성을 가지는 문제점이 있었다. 본 논문에서는 경 부하 및 대기전력모드 동작 시 자화전류를 최 소화함으로 효율을 개선한 회로를 제안하였으며 50인치 PDP TV PSU (Power Supply Unit)에 있어서 대기전력 및 보조전원으로 사용된 70W 플라이백 컨버터에 적용 실험하여 보았다.

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Choi Y.K.;Ko T.G.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.987-993
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Furthermore, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristic.

  • PDF

저압 시스템에서 비선형 부하의 사용에 따른 전류 고조파 해석 및 측정 (Analysis and Measurement of Current Harmonics Due to Non-linear Load in Low Voltage System)

  • 김종겸;이은웅
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권12호
    • /
    • pp.601-608
    • /
    • 2001
  • The ever increasing density of adjustable speed drives(ASD) device with non-linear operating characteristics has been to put tremendous harmonic stress on end user's electrical application. All ASD controllers which employ solid state power devices cause harmonic currents in the source side line. This paper describes harmonic problems for use of ASD. In order to investigate the effect of harmonics caused by using of nonlinear load at the low voltage system, we fixed up simple load model and measured the voltage and current waveforms. Measurement results show that additional operation of linear load at the parallel bus with nonlinear load such as ASD is helpful to the reduction of harmonic influence.

  • PDF

저압 시스템에서 비선형 부하의 사용에 따른 고조파 전류 해석 (Analysis of harmonics current using non-linear load at low voltage system)

  • 김종겸;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.13-16
    • /
    • 2001
  • This paper describes the problems associated with the use of PWM ASDs to drive induction motors. A major effect of harmonic voltages and currents in induction motors is increased heating due to iron and copper losses at harmonic frequencies. The harmonic components thus affect the motor efficiency, and can also affect the torque developed. In order to investigate the effect of harmonics which is caused by using of nonlinear load at the low voltage system, we fixed up simple load model and measured the voltage and current. Measurement. results show that additional operation of linear load at the parallel bus in using nonlinear load such as ASD is helpful to the reduction of harmonic current.

  • PDF

다수의 히트펌프로 구성된 냉난방시스템에서 하절기 히트펌프의 최적운전에 관한 연구 (A Study on Optimal Operation of Summer Season Cooling System with Numbers of Heat Pumps)

  • 신관우
    • 전기학회논문지P
    • /
    • 제55권1호
    • /
    • pp.35-40
    • /
    • 2006
  • Heat-pump system has a special feature that provides heating operation in winter season and cooling operation in summer season with a single system. It also has a merit that absorbs and makes use of wastewater heat, terrestrial heat, and heat energy from the air. Because heat-pump system uses midnight electric power, it decreases power peak load and is very economical as a result. By using the property that energy source is converted to low temperature when losing the heat, high temperature energy source is used to provide heating water and low temperature energy source is used to provide cooling water simultaneously in summer season. This study made up a heat-pump system with 4 air heat sources and a water heat source and implemented the optimal operation algorithm that works with numbers of heat pumps to operate them efficiently. With the heat-pump system, we applied it to cooling and heating operation in summer season operation mode in a real building.

선박발전기용 디젤엔진의 부분부하에서 에너지 효율 개선에 관한연구 (Energy efficiency improvements in part load for a marine auxiliary diesel engine)

  • 정균식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권7호
    • /
    • pp.877-882
    • /
    • 2014
  • 국제해사기구 해양환경보호위원회에서 그린하우스가스(GHG)의 주범인 CO2 배출량 감축을 위해 선박에서 대기로 방출하는 CO2의 양을 지수화 하고자 활발한 논의가 진행되고 있다. 이에 따라 에너지 효율 개선을 위해서 선체의 설계변경, 마찰저항을 줄이기 위한 도료개발, 엔진의 열효율을 개선하기 위한 첨가제 개발, 연료를 절감하기 위하여 저속운전 등 다양한 방법들이 적용되고 있다. 선박의 주 기관에서는 전 부하영역에서 효율을 높이기 위하여 전자엔진이 사용되고 있으나, 선박용 발전기 엔진은 여전히 캠으로 연료분사와 흡 배기 밸브를 구동하는 기계식 작동엔진이 대부분이다. 또한 선박용 발전기 엔진은 선박의 과부하 방지 시스템 내에서 운전되므로 대부분의 운전은 80% 이하의 부분부하 영역에서 사용되고 있다. 따라서 100%부하에 세팅된 발전기 엔진은 부분부하에서 효율적인 운전을 위해서는 연료분사시기 재조정이 필요하다. 본 연구는 현재 운항중인 선박발전용 디젤엔진의 운용특성을 파악하여 부분부하에서 연료분사시기 재조정을 통하여 연료소비량 개선에 관한 결과를 보고 하고자 한다.

I/F 초기 기동 방법을 적용한 드럼세탁기용 IPMSM의 벡터제어 (IPMSM Vector Control using an I/F Initial Operating Method for Drum Washing Machine)

  • 박진호;이정효;김경민;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.271-273
    • /
    • 2009
  • Because few signals are generated using low resolution position sensor at low speed, rotor position estimation is difficult in drum washing machine application. Besides, inertia of water and drum affect the initial operation load up to two times of rated load. Therefore overcurrent can be occurred at initial operation. In this paper, IPMSM vector control for drum washing machine is proposed by applying I/F initial operating method and sensorless control. And we verify the performance through experiment.

  • PDF