• 제목/요약/키워드: Low level irradiation

Search Result 182, Processing Time 0.029 seconds

PHOTOTOXIC EFFECTS OF LOW LEVEL LASER IRRADIATION ON HUMAN OSTEOSARCOMA CELLS (골육종세포에 미치는 레이저 조사의 광독성 효과)

  • Son, Jang-Ho;Cho, Young-Chul;Ryu, Sung-Ho;Kim, Gyoo-Cheon;Sung, Iel-Yong;Park, Bong-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.6
    • /
    • pp.509-515
    • /
    • 2004
  • Photodynamic therapy(PDT) has advanced to clinical trials for the treatment of a variety of solid tumors and presents an alternative treatment option for tumors resistant to chemo-and/or radio-therapy. PDT is based on the combination of laser light of appropriate wavelength and energy to activate a systemically or locally applied photosensitizer that concentrates preferentially in malignant tissues. In this study, phototoxicity of laser EIT 21 was analysed in human osteosarcoma cell(HOS) and the second objective of this study was to determine the ability of laser EIT 21 to induce apoptosis. This study demonstrated that laser EIT 21 had a phototoxicity to HOS cells. In order to examinate whether cell death was induced by necrosis or apoptosis, variety of techniques which assess apoptosis were used. TUNEL assay showed only a few the positive reaction on condensed nuclei. It is hard to find condensed or fragmented nuclei on HOS cells irradiated with laser EIT 21 in Hemastat and AO/EB stain. By DNA electrophoresis, cells also did not show DNA degradation characteristic of apoptosis with a ladder pattern of DNA fragments. Apoptosis-related factors were analyzed by western blotting. The expression of p53 was constant and cells irradiated with laser did not show the caspase-3 and PARP degradation, therefore we suggest that p53 and caspase-3 are not involved in laserinduced cell death.

Effects of Low-Level Laser Irradiation on the ALP Activity and Calcified Module Formation of Rat Osteoblastic Cell (저수준레이저(GaAs 반도체)조사가 골모세포의 알칼리성 인산분해효소의 활성과 석회화결절의 형성에 미치는 영향)

  • Kyung-Hun Lee;Ki-Suk Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.279-291
    • /
    • 1996
  • 저수준레에저요법에 대해서는 지난 10여년간 의학계 및 치과계에서 임상적으로 사용하여 좋은 결과가 있다고 많은 보고가 발표되고 있다. 특히 치근의 골결손에 관한 연구에서는 전기요법, 초음파요법, 전자장요법 등 뿐만아니라 저수준레이저를 사용하여 골절부내 Callus형성이 촉진되었음을 보고하고 새로운 치료법의 하나가 될 수 있음을 제안한 바도 있다. 본 연구에서는 칼륨비소를 다이오드로 사용한 저수준레이저조사가 골결손의 치유에 어떠한 영향을 미치는지 확인하고자 골모세포의 알칼리성 인산분해효소의 활성화와 석회화결절의 형성을 평가함으로 골모세포의 기능을 조사코저하였다. 실험은 첫째, 9개군으로 나누어 레이저 조사기간에 따른 알칼리성 인산분해효소의 활성화를 조사하였고, 둘째, 이를 근거로 9일간 계속 매일 1회 1.3 J/cm2의 레이저를 조사한 후 펄스의 종류별 차이를 비교하였으며, 세째,레이저펄스별 석회차 결절의 형성 정도를 광학현미경으로 관찰하여 비교분석하였다. 결과, 7일 계속 레이저를 조사한 경우 다른 군에 비해 서서히 ALP의 활성이 증가하였으나 유의한 차이는 없었으며. 따라서 9일동안 레이저를 계속 조사한 경우에는 전체 에너지량이 5.895 J/cm2 인 펄스13과 15가 뚜렷하게 유의한 증가를 보여주었다. 그러나 석회화결절의 형성은 전체 에너지량이 2.546 J/cm2 인 펄스11에서 가장 많았다. 결론적으로 골형성이나 알칼리성 인산분해효소의 활성을 촉진하는 데에는 적절한 레이저 조사조건이 필요하나, 알칼리성 인산분해효소의 활성을 촉진한 펄스와 석회화결절의 형성을 촉진하는 펄스가 서로 다르게 나타난 것은 골형성을 촉진하는 여러요인 들이 저수준레이저에 자극받았을 가능성이 높음을 보여준다 이러한 결과들로 보아 저수준레이저는 골모세포의 기능을 자극하여 골결손의 치유를 개선하는 데 도움될 것이라 사료된다.다. 각 백서의 양측 창상중 하나는 1,3,5,7일 마다 각 실험의 방법에 따라 레이저를 조사하고 실험동물의 다른 창상은 대조군으로서 사용하였다. 모든 창상의 면적은 실험 1,3,5,7 일째에 일정한 거리에서 사진촬영하여 면적계를 이용, 측정한 후 통계적인 의의를 조사하였다. 본 연구의 결과는 저수준레이저는 특정 조건하에서 S. aureus의 증식을 촉진하였다. 그러나 S. aureus에 감염된 창상을 저수준레이저로 조사시 치유가 촉진되었다. 중앙 조사법고 주변조사법에 의한 창상치유효과는 통계적인 의의가 보이지 않았다. 따라서 결론적으로 S. aureus 에 감염된 창상에 직접 또는 간접적이든 pulse의 종류에 관계없이 조사하는 경우 치유효과가 나타나는 것은 정사주위 조직의 LLLI 자극효과가 염증의 확산을 억제한다고 말할수 있다.4/1$0^{\circ}C$에서는 Shoa-Nan-Tsan과 Lenkwang이 가장 높았으며 백앙벼는 3 온도 조건 모두에서 활성이 낮았다. 발아소요일수와 amylase 활성과는 유의적인 정의 상관관계를 보였다., 다다조, 미국의 건답직파재배 품종 등이었으며 우리 나라 육성종들은 모두 지중에서 신장이 멈추어 제1본엽이 지중에서 추출하였으며, Scm파종심에서 불완전엽이 지면을 뚫고 나오는 품종은 Chinsura Boro뿐이었고 Nato, Labelle, Weld Pally, Italliconaverneco 등도 지면 가까이 까지 신장하였다. 6. 50% 출아일수는 제2절간장을 제외 한 모든 유아 형질의 신장도와 유의한 부의 상관을 보였는데 가장 높은 상관을 보인 것은 중배축장+제1절간장+불완전옆장이었으며, 다음이 불완전엽장이 었다. 7. 출아율은 중배축장+제1절간장+불완전엽장, 중배축장+초엽 장과 모든 파종심에서 높은 정의 상관을 보여 제1본엽의 추출 위치가 높을수록

  • PDF

Patterns of Failure after Combined Surgery and Radiation Therapy for Malignant Tumors of the Parotid Gland - Analysis of Treatment Results According to Pathologic Type - (근치적수술과 술후방사선치료를 받은 이하선 악성종양 환자의 치료실패 양상 - 병리학적 유형에 따른 결과를 중심으로 -)

  • Lee Sang-Wook;Chang Sei-Kyung;Kim Gwi-Eon;Suh Chang-Ok;Seong Jin-Sil;Lee Chang-Geol;Keum Ki-Chang;Park Cheong-Soo;Choi Eun-Chang
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.2
    • /
    • pp.182-188
    • /
    • 1999
  • Purpose: To investigate the treatment results' and patterns of failure according to the pathologic type of the parotid malignancy who were treated with radical sugery and postoperative radiation therapy. Materials and Methods: Fifty-two patients with various type of the parotid malignancy, who were treated with combined radical surgery and post-operative irradiation at Yonsei Cancer Center, between 1981 and 1995, were retrospectively reviewed after completion treatment, all but one patients were follow up with the median follow up period of 49 months. Results: We found that pathologically confirmed neck node metastasis rate was 28.8% all case and level II was most common site. Overall failure rate was 26.9%, local recurrence rate was 13.5%, node failure rate was 7.7%, and distant failure rate was 5.8%. Five-year disease free survival rate was 70.9%, and overall survival rate was 73.8%. Recurrence rate was low in adenoid cystic carcinoma and acinic cell carcinoma. However distant metastasis was very high in undifferentiated carcinoma. Local recurrence was main pattern of failure in mucoepidermoid carcinoma and nodal failure was frequently observed in adenocarcinoma. Conclusion: Individualized treatment plan may be required to improve a treatment outcome by pathologic subtype of the parotid malignancy.

  • PDF

The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution (다목적 방사선 조사장치 개발 및 선량분포특성)

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.42-48
    • /
    • 2002
  • The design, construction and performance test of a convenient multi-purpose irradiator is described. A multi-purpose irradiator using Cesium-137 has been developed for studies of low dose radiation effects in biology and for calibration of Thermo Luminescent dosimeter(TLD). During the operation, three rods of radioactive material which are 10cm in length revolve 180 degrees and irradiate biological samples, or TLD, and return to their shielded position, after the programmed time. A programmable Logic Controller(PLC) controls the sequence of operation, interlock, motor rotation and safety system. The rotation speed of biological samples can vary up to 20 RPM. A real time monitoring system was also incorporated to check and control the operation status of the irradiator. The capacity of the irradiation chamber was 4.5 liters. The isodose distribution at arbitrary vertical planes was measured by using film dosimetry. The dose-rate was 0.13 cGy/min in air and 0.11 cGy/min in water equivalent material in the case of Cesium-137. Range of activity was 2 Ci. The homogeneity of dose distribution in the chamber was ${\pm}$7%. The actual radiation level on the surface was within permissible levels. The irradiator had a maximum 0.35 mR/min radiation leakage on its surface.

Photocatalysis of Sub-ppm-level Isopropyl Alcohol by Plug-flow Reactor Coated with Nonmetal Elements Irradiated with Visible Light

  • Jo, Wan-Kuen
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.419-425
    • /
    • 2012
  • This work explored the characteristics and the photocatalytic activities of S element-doped $TiO_2$ (S-$TiO_2$) and N element-doped $TiO_2$ (N-$TiO_2$) for the decomposition of gas-phase isopropyl alcohol (IPA) at sub-ppm concentrations, using a plug-flow reactor irradiated by 8-W daylight lamp or visible light-emitting-diodes (LEDs). In addition, the generation yield of acetone during photocatalytic processes for IPA at sub-ppm levels was examined. The surface characteristics of prepared S- and N-$TiO_2$ photocatalysts were analyzed to indicate that they could be effectively activated by visible-light irradiation. Regarding both types of photocatalysts, the cleaning efficiency of IPA increased as the air flow rate (AFR) was decreased. The average cleaning efficiency determined via the S-$TiO_2$ system for the AFR of 2.0 L $min^{-1}$ was 39%, whereas it was close to 100% for the AFR of 0.1 L $min^{-1}$. Regarding the N-$TiO_2$ system, the average cleaning efficiency for the AFR of 2.0 L $min^{-1}$ was above 90%, whereas it was still close to 100% for the AFR of 0.1 L $min^{-1}$. In contrast to the cleaning efficiencies of IPA, both types of photocatalysts revealed a decreasing trend in the generation yields of acetone with decreasing the AFR. Consequently, the N-$TiO_2$ system was preferred for cleaning of sub-ppm IPA to S-$TiO_2$ system and should be operated under low AFR conditions to minimize the acetone generation. In addition, 8-W daylight lamp exhibited higher cleaning efficiency of IPA than for visible LEDs.

Evaluation of Biological Effects of Low Concentrations of Mercury Chloride (II) and Ionizing Radiation in the Prepubertal Male Rats (미성숙 웅성 흰쥐를 이용한 이온화 방사선 조사 및 저농도 염화수은(II)의 음용에 따른 위해성 비교 평가)

  • Kim Ji Hyang;Kim Jin Kyu;Yoon Yong Dal
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.411-418
    • /
    • 2004
  • Mercury, one of the most diffused and hazardous organ-specific environmental contaminants, exists in a wide variety of physical and chemical states. The murcury with the nature which evaporates easily can cause an acute or chronic mercury poisoning to workers at mercury-handling workplaces. Although many studies indicate that mercury induces a deleterious damage, little has been reported from the investigations of mercury effects at surrounding levels in living things. The purpose of this study was to evaluate the biological effects of mercury chloride and ionizing radiation. Prepubertal male F344 rats were administered mercury chloride in drinking water throughout the experimental period or were given wholebody irradiation with a dose of 6.5 Gy. The amount changed of body weight during the experimental period showed a 4.9% rise in the mercury-treated group and 14.4% decline in the irradiated group compared with the level of the control group. The results of hematological analysis (red blood cells, white blood cells, hemoglobin, and hematocrit) indicated the differential effects of mercury chloride and ionizing radiation. However the concentration of cortisol as assessed by radioimmunoassay increased in both of the groups. Relative expressions of mRNA related to mitochondrion-mediated apoptosis were investigated using semiquantitative reverse transcription polymerase chain reaction on gonad and urinary organs of the experimental groups. While the expression of Bcl-2 mRNA exhibited different patterns depending on the organs or the experimental groups, both of the experimental groups showed a conspicuous expressions of Bax mRNA. In conclusion, the target organ of mercury chloride seems to be a urinary organ and the pattern of damage induced by mercury chloride differs from that by ionizing radiation.

Reliable and High Spatial Resolution Method to Identify the Number of MoS2 Layers Using a Scanning Electron Microscopy

  • Sharbidre, Rakesh Sadanand;Park, Se Min;Lee, Chang Jun;Park, Byong Chon;Hong, Seong-Gu;Bramhe, Sachin;Yun, Gyeong Yeol;Ryu, Jae-Kyung;Kim, Taik Nam
    • Korean Journal of Materials Research
    • /
    • v.27 no.12
    • /
    • pp.705-709
    • /
    • 2017
  • The electronic and optical characteristics of molybdenum disulphide ($MoS_2$) film significantly vary with its thickness, and thus a rapid and accurate estimation of the number of $MoS_2$ layers is critical in practical applications as well as in basic researches. Various existing methods are currently available for the thickness measurement, but each has drawbacks. Transmission electron microscopy allows actual counting of the $MoS_2$ layers, but is very complicated and requires destructive processing of the sample to the point where it will no longer be useable after characterization. Atomic force microscopy, particularly when operated in the tapping mode, is likewise time-consuming and suffers from certain anomalies caused by an improperly chosen set point, that is, free amplitude in air for the cantilever. Raman spectroscopy is a quick characterization method for identifying one to a few layers, but the laser irradiation causes structural degradation of the $MoS_2$. Optical microscopy works only when $MoS_2$ is on a silicon substrate covered with $SiO_2$ of 100~300 nm thickness. The last two optical methods are commonly limited in resolution to the micrometer range due to the diffraction limits of light. We report here a method of measuring the distribution of the number of $MoS_2$ layers using a low voltage field emission electron microscope with acceleration voltages no greater than 1 kV. We found a linear relationship between the FESEM contrast and the number of $MoS_2$ layers. This method can be used to characterize $MoS_2$ samples at nanometer-level spatial resolution, which is below the limits of other methods.

Adsorption and Regeneration Characteristics of Ammonia on NiCl2 Impregnated Adsorbents (NiCl2 첨착된 흡착제 상에서 암모니아의 흡착 및 재생 특성)

  • Lim, Jeong-Hyeon;Song, Kang;Park, Chu-Sik;Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.33 no.2
    • /
    • pp.202-209
    • /
    • 2022
  • Effects of the support and amount of NiCl2 on ammonia adsorption capacity were investigated to improve the ammonia adsorption performance. NiCl2 was impregnated onto the surface of various supports under ultrasonic irradiation. The physicochemical properties and ammonia adsorption performance of NiCl2-impregnated adsorbents were investigated. Among the various supports, it was found that the adsorption capacity of ammonia was the best when NiCl2 was impregnated on activated carbon (AC) with the highest specific surface area. As a result of changing the amount of NiCl2 impregnated on AC, the NiCl2(2.0)/AC adsorbent impregnated with 2 mmol·g-1 of NiCl2 showed the highest ammonia adsorption capacity of 5.977 mmol·g-1. In addition, the adsorption capacity was found to be maintained at an almost constant level in five repeated cycle tests under the condition that low-temperature heat could be utilized. This indicates that the adsorbent has excellent regeneration ability.

Strain Improvement of Penicillium verruculosum for High Cellulase Production by Induced Mutation (섬유소분해효소 생산증진을 위한 Penicillium verruculosum의 균주개량)

  • 정기철
    • Microbiology and Biotechnology Letters
    • /
    • v.15 no.6
    • /
    • pp.388-395
    • /
    • 1987
  • In order to obtain a regulatory mutant strain with high cellulase activity, a newly isolated Penicillium verrculosum, strain F-3 was used as parental strain since it was proved to be an efficient cellulase producer. A number of experiments were conducted to determine the optimum conditions to in-duce mutagenesis and isolate the desirable mutant strains. Out of several restriction compounds tested, 1.5% oxgall was found to be most effective to restrict the colony size by suppressing overgrowth. Derepression of catabolites was employed as a criterion in selecting mutant strains with high cellulase productivity. Production of cellulase by Penicillium venculosum F-3 was suppressed when cultured on the media with more than 1% of glucose or glycerol. It was found that either irradiation with UV light for 19 mins or treatment with nitrosoguanidine at 200$\mu\textrm{g}$/m1 for 60 mins, induced mutagenesis at desired level, when the survival rate of the spore was 0.2% and 48%, respectively. Three mutant strains of F-3, UV-9, UV-10, and NTG-3 that had the highest cellulase productivity were finally selected, based on filter paper degradation rate, size of clearing zone on the screening plate and cellulase activity in the medium containing cellulose powder. When the mutant strains were compared with parental strain F-3, on the KC-M-W medium containing cellulose powder, the filter paper activities of UV-9, UV-10, and NTG-3 were increased by 34%, 55%, and 41%, respectively. However, the assimilation of cellobiose octaacetate by UV-9 or NTG-3 was markedly reduced. When the mutant UV-10 was grown on cellobiose octaacetate medium (CCA-4) in shaking flasks, the cellulase activities of the mutant increased by 20 to 50% compared to the parental strain. Excreation of soluble protein from the mutant also elevated up to 30%. The mutant also constitutively produced both CMCase and $\beta$-glucosidase, though at relatively low level, in the presence of glucose or cellobiose as carbon sources.

  • PDF

Evaluation of Ovary Dose for woman of Childbearing age Woman with Breast cancer in tomotherapy (가임기 여성의 유방암 토모치료 시 난소선량 평가비교)

  • Lee, Soo Hyeung;Park, Soo Yeun;Choi, Ji Min;Park, Ju Young;Kim, Jong Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.337-343
    • /
    • 2014
  • Purpose : The aim of this study is to evaluate unwanted scattered dose to ovary by scattering and leakage generated from treatment fields of Tomotherapy for childbearing woman with breast cancer. Materials and Methods : The radiation treatments plans for left breast cancer were established using Tomotherapy planning system (Tomotherapy, Inc, USA). They were generated by using helical and direct Tomotherapy methods for comparison. The CT images for the planning were scanned with 2.5 mm slice thickness using anthropomorphic phantom (Alderson-Rando phantom, The Phantom Laboratory, USA). The measurement points for the ovary dose were determined at the points laterally 30 cm apart from mid-point of treatment field of the pelvis. The measurements were repeated five times and averaged using glass dosimeters (1.5 mm diameter and 12 mm of length) equipped with low-energy correction filter. The measures dose values were also converted to Organ Equivalent Dose (OED) by the linear exponential dose-response model. Results : Scattered doses of ovary which were measured based on two methods of Tomo helical and Tomo direct showed average of $64.94{\pm}0.84mGy$ and $37.64{\pm}1.20mGy$ in left ovary part and average of $64.38{\pm}1.85mGy$ and $32.96{\pm}1.11mGy$ in right ovary part. This showed when executing Tomotherapy, measured scattered dose of Tomo Helical method which has relatively greater monitor units (MUs) and longer irradiation time are approximately 1.8 times higher than Tomo direct method. Conclusion : Scattered dose of left and right ovary of childbearing women is lower than ICRP recommended does which is not seriously worried level against the infertility and secondary cancer occurrence. However, as breast cancer occurrence ages become younger in the future and radiation therapy using high-precision image guidance equipment like Tomotherapy is developed, clinical follow-up studies about the ovary dose of childbearing women patients would be more required.