• 제목/요약/키워드: Low initial intensity

검색결과 119건 처리시간 0.029초

The Effects of Exercise Intensity and Initial Timing on Functional Recovery after Sciatic Nerve Crush Injury in Rats

  • Cai, Junyan;Na, Sang-su;Hwangbo, Gak
    • 대한물리의학회지
    • /
    • 제10권3호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE: The aim of this study was to investigate the effects of exercise intensity and initial timing on functional recovery following sciatic nerve injury in rats. METHODS: Total of 80 Sprague-Dawley rats was used and randomly divided 6 groups. Under deep anesthesia, the sciatic nerve was nipped by adapted hemostatic tweezers for 30 seconds and the injured nerve was transparent under naked eyes. Acute exercise groups was applied treadmill after sciatic nerve crush injury during 5days with three type intensity. Late exercise groups was also applied treadmill during 5 days with three type intensity after 5 days break. Values of sciatic functional index were measured and analyzed in each group after exercise period. RESULTS: The sciatic functional index values between control groups 1, acute low-intensity group, acute middle-intensity group in acute phase showed statistical significant (p<.05). The sciatic functional index values between control groups 2, late low-intensity group, late middle-intensity group and late high-intensity in late phase showed statistical significant (p<.05). The comparison in acute and late phase, sciatic functional index values of each low-intensity group and each high-intensity group showed statistical significant (p<.05). CONCLUSION: Whether at acute or late phase, treadmill exercise as a therapy obtained beneficial effects of functional recovery and exercise training at low speed is more beneficial effects on the recovery of motor function in acute phase.

비대칭 압연한 강판의 GOSS 방위 발달에 미치는 초기 집합조직의 영향 (Effect of Initial Texture on the Development of Goss Orientation of Asymmetrically Rolled Steel Sheets)

  • 이철우;정효태;이동녕;김인수
    • 소성∙가공
    • /
    • 제29권1호
    • /
    • pp.27-36
    • /
    • 2020
  • The Goss texture component of {110}<001> is well known as one of the best texture components to improve the magnetic properties of electrical steel sheets. The small amount of the Goss texture component is obtained at the surface of the steel sheet by shear deformation due to friction between the steel sheet and the roll during conventional symmetric rolling. This study aims to identify a method to obtain high intensity of the Goss texture component not only at the surface but in the whole layer of the steel sheet by shear deformation of asymmetric rolling. Low carbon steel sheets, which have different initial texture, were asymmetrically rolled by about 50%, 70%, and 80%. The pole figures of the top, center, and bottom layers of the initial and asymmetrically rolled low carbon steel sheets were measured by an X-ray diffractometer. Based on the measured pole figures of these samples, the intensities of the main texture components were analyzed for the initial and asymmetrically rolled low carbon steel sheets. As a result, the initial low carbon steel sheet with the γ-fiber component showed a higher intensity of the Goss texture component in the whole layer than the steel sheet with other texture components after asymmetric rolling.

초기 저광도 광중합이 레진 수복물의 결합강도에 미치는 영향에 관한 연구 (A STUDY OF THE EFFECT OF LOW INTENSITY INITIAL LIGHT CURING ON THE BOND STRENGTH OF RESIN RESTORATION)

  • 한미란;권순원;김종수
    • 대한소아치과학회지
    • /
    • 제28권1호
    • /
    • pp.45-53
    • /
    • 2001
  • 레진 수복에서 초기에 저광도로 중합하여 레진의 유동성을 허용함으로써 중합시 내부응력을 상쇄하며, 다시 고광도로 중합하여 레진의 물성도 유지할 수 있는 방법이 시도되고 있어 초기 저광도 중합이 상아질과의 결합 강도와 레진의 미세경도에 미치는 영향을 알아보고자 하였다. 소의 건전한 하악 전치 20개를 3개의 절편으로 절단하여 각 군에 배분하고 상아질면에 레진을 충전한 후, I군은 $450mW/cm^2$의 광도도 40초간, II군은 $300mW/cm^2$$600mW/cm^2$의 광도로 각각 20초씩 III군은 $250mW/cm^2$$450mW/cm^2$에서 각각 20초씩 광중합하여 전단 결합 강도를 측정하였고, 직경 5.0mm깊이 2.0mm레진 시편을 제작하여 상, 하면 중앙에서 Vickers 미세 경도를 측정하였다. 전단결합 강도는 초기 저광도 중합군의 평균이 다소 높았으나 각 군간 통계학적 유의한 차이는 없었으며, 미세 경도는 상하면 모두에서 각 군간 통계학적으로 유의한 차이는 보이지 않았다.

  • PDF

Comparisons of Increased Repetitions and Exercise Intensity of the Symmetric Upper Limbs between Men and Women

  • Jee, Haemi
    • 국제물리치료학회지
    • /
    • 제11권3호
    • /
    • pp.2147-2154
    • /
    • 2020
  • Background: Improperly conducted exercise may lead to worsening of musculoskeletal complications. Such may worsen due to increased repetition and intensity during exercise. In addition, different responses may show different needs for training program. Objectives: To compare kinematics of symmetric concentric and eccentric motions during increased repetitions and intensities for men and women. Design: Quasi-randomized trial. Methods: A total of ten men and eleven women participated in this study. Concentric and eccentric motions of the lateral raises were observed for initial positions of abduction and adduction. Low and high exercise intensities were applied, and 15 repetitions were conducted for both intensities. Initial, 3 inbetween repetitions, and last repetition were recorded for comparisons. Results: The concentric or abduction motions showed no significant differences for all comparisons. However, eccentric or adduction motions showed greater significant differences as the exercise intensity increased for both men and women. Such significant differences were most prevalent during the first and last repetitions with greatest differences during the initial repetitions. Conclusion: Kinematic difference between men and women during increased repetitions and intensity indicate the need for more individualized exercise intervention and consideration between men and women. Individualized interventions may prevent exercise-induced postural abnormality and corresponding musculoskeletal dysfunction.

영어 문장 내 상이한 위치에 나타난 저성조 피치 액센트 연구 (A Study on Low Pitch Accent Produced in Different Locations in English Sentences)

  • 이서배;김수정
    • 말소리와 음성과학
    • /
    • 제3권4호
    • /
    • pp.63-70
    • /
    • 2011
  • Recent studies on English $L^*$ (low pitch accent) have revealed the difference of changes in acoustic manifestation between utterances produced by Koreans and those produced by native speakers of English. However, not much effort has been made to compare $L^*$ focused constituents and non-focused constituents. At the same time, most previous works on focus realization are lacking in terms of normalization of acoustic measurement. Therefore, this research is dedicated to comparing the $L^*$ focused items and non-focused items realized by Koreans and Americans and to examining the realization of English $L^*$ produced by the two language groups with improved normalization of the acoustic features (F0, intensity and duration). Within-group analysis comparing focused words and non-focused words showed both Americans and Koreans prolonged the $L^*$ focused syllables but the effect size of syllable lengthening made by Koreans was far less than that made by Americans. Furthermore, significant F0 lowering was found in Americans but not in Koreans. However, the effect of intensity change caused by $L^*$ focus was not significant within each group. The effect of focused words was tested between the two groups revealing that Koreans implemented English $L^*$ focus with higher F0, lower intensity and shorter duration than Americans. In the instances in which a significant Group x Focus Location (initial, middle and final of a sentence) interaction was found, further analysis testing the effect of Group on each Focus Location was conducted. The testing showed that the Koreans produced shorter syllables at initial and middle of a sentence and higher F0 at initial of a sentence than Americans. Implications for the intonation training were also discussed.

  • PDF

Effects of High-Intensity Interval Training on Motor Skills Recovery in Sciatic Nerve Crush-Induced Rats

  • Kim, Ki-Hyun;Shin, Hyung-Soo;Jung, Nam-Jin;Hwangbo, Gak
    • 대한물리의학회지
    • /
    • 제15권1호
    • /
    • pp.43-54
    • /
    • 2020
  • PURPOSE: This study examined the effects of mild-intensity exercise (MIE) and high-intensity interval exercise (HIIE) on the recovery of the motor function over time in sciatic nerve crush injury rats. METHODS: The MIE group ran on a treadmill at a speed of 8.3 m/min to perform low-intensity training with maximum oxygen uptakes ranging from 40 to 50%. The HIIE group ran on the treadmill at a speed of 25 m/min to perform high-intensity training with a maximum oxygen uptake of 80%. The interval training was performed based on a 1:1 work-to-rest ratio. The effects of each form of exercise on the rats' walking abilities following their recovery from the peripheral nerve injuries were evaluated based on the results of behavior tests performed at one and 14 days. RESULTS: According to the test results, the MIE group showed significant improvements in the rats' ankle angle in the initial stance phase, and in the ankle and knee angles in the toe-off phase (p<.05). The HIIE group exhibited significant improvements in the ankle and knee angles in the initial stance phase, SFI(p<.05). CONCLUSION: The state of such patients can be improved by applying the results of this study in that MIE and HIIE on a treadmill can contribute to the recovery of the peripheral nerve and motor skill. In particular, MIE is used as a walking functional training in the toe-off stance phase, while HIIE is suitable in the initial stance stage.

UV/TiO2 광촉매반응에 의한 페놀의 분해 특성 (Characteristics of Phenol Degradation by using UV/TiO2 Photocatalysis)

  • 신인수;최봉종;이승목
    • 한국물환경학회지
    • /
    • 제20권5호
    • /
    • pp.488-493
    • /
    • 2004
  • The effects were examined from several conditions of $TiO_2$ photocatalysis reaction to phenols degradation by changing it's reacting conditions such as phenol concentration, pH, $TiO_2$ concentration, $H_2O_2$ concentration, flow rate, and intensity of ultraviolet rays. Phenol degradation was more efficient in low concentration of phenol, neutral pH. Phenol degradation appeared to increase as concentration of $TiO_2$ photocatalyst, that of $H_2O_2$ and intensity of ultraviolet rays increased. As $TiO_2$ dosage increased, initial rate constant k linearly increased. When $H_2O_2$ was injected more than optimum, phenol removal rate didn't increase in proportional to the change of $H_2O_2$ concentration as OH radicals was being consumed. When flow rate is less than $4.75m^3/m^2$ day, phenol removal efficiency appeared to decrease as ultraviolet rays transmission rate becomes low by $TiO_2$ suspension coated in photo reaction column. Meanwhile, initial rate constant according to light intensity change in less than $25mW/cm^2$ appeared to be in proportion to light intensity ($mW/cm^2$) Removal efficiency decreased about 12% after 180 minutes of reaction time while showed stable removal efficiency of 100% after 300 minutes when using regenerated $TiO_2$.

가변 광도에 따른 복합레진의 기계적 물성 및 변연누출도 변화 (MECHANICAL PROPERTIES AND MICROLEAKAGE OF COMPOSITE RESIN MATERIALS CURED BY VARIABLE LIGHT INTENSITIES)

  • 한승렬;민경산;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제28권2호
    • /
    • pp.134-145
    • /
    • 2003
  • Mechanical properties and microleakage of two composites [conventional hybrid type DenFil (VERICOM Co., Anyang, Korea) / micro matrix hybrid type Esthet X (Dentsply Caulk, Milford, DE, U.S.A.)] were evaluated to assess whether variable light intensity curing is better than conventional curing technique. Curing was done for 40 seconds in two ways of 2 step soft-start technique and 5 step ramping technique. Three kinds of light intensities of 50, 100, $200{\;}mW/\textrm{cm}^2$ were initially used for 10, 20, 30 seconds each and the maximum intensity of $600 {\;}mW/\textrm{cm}^2$ was used for the rest of curing time in a soft-start curing tech nique. In a ramping technique, curing was done with the same initial intensities and the light intensity was increased 5 times with the same rate to the maximum intensity of $600{\;}mW/\textrm{cm}^2$. After determining conditions that showed no different mechanical properties with conventional technique, Esthet X composite was filled in a class V cavity, which dimension was $4{\times}3{\times}1.5{\;}mm$ and cured under those conditions. Microleakage was evaluated in two ways of dye penetration and maximum gap estimation through SEM observation. ANOVA and Spearman's rho test were used to confirm any statistical significance among groups. The results were as follows : 1 Several curing conditions of variable light intensities resulted in the similar mechanical properties with a conventional continuous curing technique, except conditions that start curing with an initial light intensity of $50{\;}mW/\textrm{cm}^2$. 2. Conventional and ramping techniques were better than soft-start technique in mechanical properties of microhardness and compressive strength. 3. Soft-start group that started curing with an initial light intensity of $100{\;}mW/\textrm{cm}^2$ for 10 seconds showed the least dye penetration. Soft-start group that started curing with an initial light intensity of $200{\;}mW/\textrm{cm}^2$ for 10 seconds showed the smallest marginal gap, if there was no difference among groups. 4. Soft-start technique resulted in better dye-proof margin than conventional technique(p=0.014) and ramping technique(p = 0.002). 5. There was a very low relationship(p=0.157) between the methods of dye penetration and marginal gap determination through SEM evaluation. From the results of this study, it was revealed that ramping technique would be better than conventional technique in mechanical properties, however, soft-start technique might be better than conventional one in microleakage. It was concluded that much endeavor should be made to find out the curing conditions, which have advantages of both aspects or to solve these kinds of problems through a novel idea of polymerization.

Effect of Low Intensity Pulsed Electric Field on Ethanol Fermentation and Chemical Component Variation in a Winemaking Culture

  • Min, He-Ryeon;Jeon, Bo-Young;Seo, Ha-Na;Kim, Min-Ju;Kim, Jun-Cheol;Kim, Joon-Kuk;Park, Doo-Hyun
    • Food Science and Biotechnology
    • /
    • 제18권6호
    • /
    • pp.1358-1364
    • /
    • 2009
  • Electric polarity of working electrode and counter electrode was periodically switched at the intervals of 30 sec. Electric current generated by anodic and cathodic reaction of working electrode was reached to +30 and -12 mA in low intensity pulsed electric field (LIPEF). The yeast growth, ethanol production, and malate consumption in the initial cultivation time were more activated in the LIPEF than the conventional condition (CC). Polyphenol, total phenolic contents (TPC), and total flavonols (TF) were gradually decreased in all cultivation conditions during incubation for 2 weeks but antioxidation activity was not. TF was significantly lower in 3 and 4 V of LIPEF than CC and 2 V of LIPEF; however, the polyphenol, TPC, and antioxidation activity were a little influenced by the LIPEF. After ripening of the winemaking culture for 15 days, polyphenol, TPC, and TF were a little increased but the antioxidation activity was not.

열간 비대칭 압연한 AA1050 Al 판재의 집합조직과 소성변형비 변화 (Texture and Plastic Strain Ratio Changes of Hot Asymmetrically Rolled AA1050 Al Sheet)

  • 보보무로드 함라쿠로프;이철우;김인수
    • 소성∙가공
    • /
    • 제28권5호
    • /
    • pp.287-293
    • /
    • 2019
  • The plastic strain ratio is one of the factors of the deep drawability of metal sheets. The plastic strain ratio of Al sheet is low value. Therefore, it is necessary to increase the plastic strain ratio in order to improve the deep drawability of the Al sheet. This study investigated the increase in the plastic strain ratio and the texture change of AA1050 Al sheet after the hot asymmetric rolling. The average plastic strain ratio of initial AA1050 Al sheets was 0.41. After 84% hot asymmetric rolling at $400^{\circ}C$, the average plastic strain ratio was 0.77. The average plastic strain ratio of 84% hot asymmetrically rolled AA1050 Al sheet at $400^{\circ}C$ is 1.9 times higher than that of initial AA1050 Al sheet. The ${\mid}{\Delta}R{\mid}$ of 84% hot asymmetrically rolled AA1050 Al sheet at $400^{\circ}C$ is 1/2 times lower than that of initial AA1050 Al sheet. This result is due to the development of the intensity of the ${\gamma}-fiber$ texture and the decrease of the intensity of {001}<100> texture after the hot asymmetric rolling of AA1050 Al sheet.