• Title/Summary/Keyword: Low heating value

Search Result 245, Processing Time 0.026 seconds

Physicochemical Properties of a Biopolymer Flocculant Produced from Bacillus subtilis PUL-A (Bacillus subtilis PUL-A로부터 생산된 Biopolymer 응집제의 물리화학적 특성)

  • Ryu, Mi-Jin;Jang, Eun-Kyung;Lee, Sam-Pin
    • Microbiology and Biotechnology Letters
    • /
    • v.35 no.3
    • /
    • pp.203-209
    • /
    • 2007
  • Soybean milk cake (SMC) was used for the solid-state fermentation by Bacillus subtilis PUL-A isolated from soybean milk cake. In the presence of 5% glutamate the maximum production of biopolymer (59.9 g/kg) was performed by fermentation at $42^{\circ}C$ for 24 hr. The recovered biopolymer was consisted of 87% $\gamma$-polyglutamic acid with molecular weight of $1.3{\times}10^6$ dalton and other biopolymer. The biopolymer solution showed the great decrease in consistency below pH 6.0, regardless of the molecular weight of PGA. Biopolymer solution has a typical pseudoplastic flow behavior and yield stress. The consistency of biopolymer solution was greatly decreased by increasing heating time and temperature in acidic condition compared to the alkaline condition. In kaolin clay suspension, the flocculating activity of biopolymer was the highest value with 15 mg/L biopolymer and 4.5 mM $CaCl_2$, but decreased greatly with $FeCl_3$. The flocculating activity of biopolymer was maximum at pH5, but decreased drastically by heating at $60{\sim}100^{\circ}C$. In particular, biopolymer with native PGA showed the efficient flocculating activity compared to that of modified biopolymer containing low molecular weight of PGA.

An Experimental Study on the Devolatilization Kinetics of Ashless coal in Fixed and Entrained Conditions (초청정 석탄의 탈휘발 반응률에 관한 실험적 연구)

  • Yu, Da-Yeon;Lee, Byoung-Hwa;Song, Ju-Hun;Lee, Si-Hyun;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.997-1003
    • /
    • 2011
  • In order to investigate devolatilization characteristics for ashless coal with relatively low ash content and high heating value, an experiment was performed in different bed configurations of TGA and DTF(Drop Tube Furnace) at atmospheric pressure condition. The heating rate was $10^{\circ}C$/min up to $950^{\circ}C$ in TGA, while the temperatures of DTF varied from 500 to $1300^{\circ}C$ in step of $200^{\circ}C$. A weight loss and particle temperature were obtained to determine devolatilization kinetics. The kinetic parameters including an activation energy and pre-exponential factor for ashless coal were obtained using Coats-Redfern method in TGA and single step method in DTF. Furthermore, the devolatilization kinetics of the ashless coal were compared with the results of different kinds of conventional coal such as sub-bituminous and bituminous. The results show that the activation energy of devolatilazation for ashless coal is lower than those of others in fixed and entrained conditions.

An Experimental Investigation of the Effect of Particle Size on the Combustion Characteristics of Pulverized Sub-Bituminous Coal with Low Calorific Value by Using an LFR System (LFR 장치를 이용한 입자 크기 변화에 따른 저열량 아역청 미분탄의 연소특성에 관한 실험적 연구)

  • Jeon, Chung-Hwan;Kim, Yong-Gyun;Kim, Jae-Dong;Kim, Gyu-Bo;Song, Ju-Hun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.259-267
    • /
    • 2010
  • In this study, the effect of particle size on the combustion characteristics of pulverized sub-bituminous coal was experimentally investigated. A laminar-flow-entrained reactor was designed and implemented to realize the desired heating ratio and temperature corresponding to the combustion atmosphere of a pulverized-coal-fueled furnace. The flame length and structure of burning particles according to different sizes were investigated. Coal combustion processes were clearly distinguished by direct visual observation of the flame structure. The onset point of volatile ignition is greatly affected by changes in the particle size, and the burning time of the volatiles is least affected by changes in the particle size. The length and instability of char flame also increase with the increase of the particle size. However, the char consumption rate within the residential time remains nearly constant.

The Study on the improvement of vehicle fuel economy test method according to the characteristics of test fuel (시험용 연료 특성에 따른 자동차 연비측정 방법 개선에 관한 연구)

  • Lee, Minho;Kim, Jeonghwan
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.9-18
    • /
    • 2014
  • These test methods, the current domestic vehicles fuel economy calculation method is tested on a dynamometer for vehicles after you have installed the vehicle, given the test mode(FTP-75 & HWFET mode, etc.) are measured by vehicle emissions and fuel economy by seeking to have the results approach, the carbon balance method. At this point, using the carbon balance method is a test method was developed seeking fuel for a standard fuel properties, where the value of the constant and saved test was measured in THC, CO, $CO_2$ has a value calculation. Therefore, use fuel which is changed every time you test the fuel properties characteristics are not considered exactly. In this study, using the carbon balance method and fluid flow rate of the fuel used in the actual test is measured by comparing the results with the flow measurement methods, properties of the fuel used for the test attribute to study ways that can be considered, taking into account the physical attributes of a more diverse fuel line and fuel economy improved measurement methods that can be reviewed.

Synthesis, Characterization and Ammonia Decomposition Reaction Activity of Vanadium Oxynitride Obtained from the Reduction/Nitridation of Vanadium Oxide (바나디움 산화물의 환원 및 질화반응으로부터 얻어진 바나디움 산화질화물의 제조, 특성분석 및 암모니아 분해반응에서의 촉매 활성)

  • Yun, Kyung Hee;Shin, Chae-Ho
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.620-629
    • /
    • 2022
  • By varying various experimental conditions such as heating rate, molar hourly space velocity (MHSV), and nitridation reaction temperature, vanadium oxynitride was prepared through temperature programmed reduction/nitridation reaction (TPRN) of vanadium pentoxide and ammonia, and characterization were performed. In order to investigate the physico-chemical properties of the prepared catalyst, N2 adsorption-desorption analysis, X-ray diffraction analysis (XRD), hydrogen temperature programmed reduction (H2-TPR), temperature programmed oxidation (TPO), ammonia temperature programmed desorption (NH3-TPD), transmission electron microscopy (TEM) was performed. Transformation of V2O5 with 5 m2 g-1 low specific surface area by reduction at 340 ℃ to V2O3 showed a high specific surface area value of 115 m2 g-1 by micropore formation. As the nitridation temperature increased beyond that, the specific surface area continued to decrease due to sintering. The nitridation reaction variable that had the greatest influence on the specific surface area was the reaction temperature, and the x + y value of VNxOy of a single phase approached from 1.5 to 1.0 as the nitridation reaction temperature increased. At a high reaction temperature of 680 ℃, the cubic lattice constant a was VN. close to the value. At 680 ℃, the highest nitridation temperature among the experimental conditions, the ammonia conversion rate was 93%, and no deactivation was observed.

Winter Indoor Thermal Environment Status of Nursery Rooms in Workplace Daycare Centers in Jeju Island (제주지역 직장어린이집 보육실의 겨울철 실내온열환경 실태)

  • Kim, Bong-Ae;Ko, Youn-Suk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.81-90
    • /
    • 2017
  • This study was conducted to investigate the thermal environment status of nursery rooms in workplace daycare centers in Jeju and propose measures to improve their indoor physical thermal environment. For this purpose, measurements were performed in the winter indoor physical environment of 51 nursery rooms in 11 workplace daycare centers and a psychological evaluation survey on the thermal environment of nursery rooms was conducted for 70 nursery teachers. The investigation was carried out over 11 days in January 2017. The results are as follow. The average indoor temperature of the nursery rooms was $21.3^{\circ}C$($18.7-23.8^{\circ}C$) and the indoor temperatures of 47 nursery rooms (92.9%) were higher than the environmental hygiene management standard for domestic school facilities ($18-20^{\circ}C$). The average relative humidity was 33.9% (16.4-56.0%), and 37 nursery rooms (86.3%) showed a lower average relative humidity than the standard (40-70%). The average absolute humidity was $9.1g/m^3$ ($4.7-13.6g/m^3$), which was lower than the standard for preventing influenza ($10g/m^3$). When the indoor temperature and humidity of the nursery rooms were compared with international standards, it was found that 85% or more of the 51 nursery rooms maintained appropriate indoor temperatures, but 40-50% of the nursery rooms maintained a low humidity condition. Therefore, they need to pay attention to maintaining the appropriate humidity of the nursery room to keep the children healthy. The average indoor temperature of the nursery rooms showed a weak negative correlation with the average relative humidity. The indoor temperature had a significant effect on the relative humidity: a higher indoor temperature resulted in lower relative humidity. Regarding the fluctuations in the average indoor temperature of the nursery rooms during the day, in daycare centers that used floor heating, the indoor temperature gradually increased form the morning to the afternoon and tended to decrease during lunch time and the morning and afternoon snack times, due to ventilation. The daycare centers that used both floor heating and ceiling-type air conditioners showed a higher indoor temperature and greater fluctuations in temperature compared to the daycare centers that used floor heating only. In the survey results, the average value of the whole body thermal sensation was 3.0 (neutral): 32 respondents (62.7%) answered, "Neutral", Which was the largest number, followed by 21 respondents (30%) who answered, "Slightly hot" and 17 respondents (24.2%) who answered, "Slightly cold." Twenty-nine respondents answered, "Slightly dry," which was the largest number, followed by 28 respondents (54.9%) who answered, "Neutral" and 10 respondents (19.6%) who answered, "Dry." The total number of respondents who answered, "Slightly dry" or "Dry" was large at 39 (56.4%), which suggests the need for indoor environment management to prevent a low-humidity environment. To summarize the above results about the thermal environment of nursery rooms, as the indoor temperature increased, the relative humidity decreased. This suggests the effect of room temperature on the indoor relative humidity; however, frequent ventilations also greatly decrease the relative humidity. Therefore, the ventilation method and the usage of air conditioning systems need to be re-examined.

Overall Performance characteristic for 300MW Taean IGCC Plant (300MW 태안 IGCC 플랜트 종합성능 특성)

  • Kim, Hakyong;Kim, Jaehwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.129.2-129.2
    • /
    • 2010
  • As a part of the government renewable energy policy, KOWEPO is constructing 300MW IGCC plant in Taean. IGCC plant consists of gasification block, air separation unit and power block, which performance test is separately conducted. Overall performance test for IGCC plant is peformed to comply with ASME PTC 46. Major factors affected on the overall efficiency for IGCC plant are external conditions, each block performance(gasification, ASU, power block), water/steam integration and air integration. Performance parameters of IGCC plant are cold gas efficiency, oxygen consumption, sensible heat recovery of syngas cooler for gasification block and purity of oxygen, flow amount of oxygen and nitrogen, power consumption for air separation unit and steam/water integration among the each block. The gas turbine capacity applied to the IGCC plant is 20 percent higher than NGCC gas turbine due to the low caloric heating value of syngas, therefor it is possible to utilize air integration between gas turbine and air separation unit to improve overall efficiency of the IGCC plant and there is a little impact on the ambient condition. It is very important to optimize the air integration design with consideration to the optimized integration ratio and the reliable operation. Optimized steam/water integration between power block and gasification block can improve overall efficiency of IGCC plant where the optimized heat recovery from gasification block should be considered. Finally, It is possibile to achieve the target efficiency above 42 percent(HHV, Net) for 300MW Taean IGCC plant by optimized design and integration.

  • PDF

Physico-Chemical Characteristics of Municipal Solid Wastes in the East Coast of Gangwon (강원 동해안지역의 생활폐기물 발생특성)

  • Lee Hae-Seung;Choi Yog-Bum;Kim Byoung-Ug
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.1 s.55
    • /
    • pp.1-11
    • /
    • 2005
  • This research was performed to investigate the generation and physico-chemical characteristics of municipal solid wastes in the east coast of gangwon. The results were as follows: i) The generation rate of G city and Y gun were 0.187-0.384 $\cal{kg/cap/d}$ and 0.136-0.259 $\cal{kg/cap/d}$. Apparent density of G city and Y gun were 137.9-191.9 g/L and 157.3-238.3 g/L, respectively. ii) The wastes consisted of $76.1-97.5\%$ of combustibles and $2.5-23.9\%$ of incombustibles in G city. And the wastes consisted of $73.7-98.6\%$ of combustibles and $1.4-26.3\%$ of incombustibles in Y gun. Most of municipal solid wastes are composed of food, paper, and vinyl-plastics waste. Water content of commercial area, agricultural resident, detached resident, apartment area, school zone were 42.5-45.9, 37.6-43.4, 32.4-38.4, 29.3-32.3, $6.8-26.9\%$, respectively. iii) The low heating value of G city and Y gun were 1,125.5-2,540.7 $\cal{kcal/kg}$, 1,104.4-2,062.3 $\cal{kcal/kg}$, and school and apartment area were higher than commercial area.

Developing Polyclonal Antibody-based Indirect-ELISA to Detect Anthracnose Inocula Prior to Soybean Sprout Rot

  • Park, Soo-Bong;Lim, Young-Ji;Lee, Jung-Han;Han, Ki-Soo;Lee, Sun-Cheol;Shim, Chang-Ki;Kang, Jin-Ho;Bae, Dong-Won;Kim, Dong-Kil;Kim, Hee-Kyu
    • The Plant Pathology Journal
    • /
    • v.20 no.4
    • /
    • pp.252-257
    • /
    • 2004
  • We developed a polyclonal antibody based-ELISA system to monitor inocula accurately and rapidly before onset of anthracnose on soybean sprouts. Titer of mouse antisera against conidia of Colletotrichum gloeosporioides, determined by indirect ELISA, was high enough to be detectable up to ${\times}$25,600 dilutions. Both PAb1 and PAb2 had the highest level of reactivity to Colletotrichum gloeosporioides. Absorbance readings exceeded 0.15. Sensitivity of PAb to C. gloeosporioides was precise enough to detect spore concentration as low as 500 conidia/well by indirect ELISA. Both antibodies are very sensitive and highly specific to the target pathogen Colletotrichum gloeosporioides, apparently discriminating other unrelated pathogen, or epiphytes. This kit fulfills the requirements far detecting inocula before infection and onset of anthracnose. Our ELISA system should also be feasible to detect C. acutatum (Mungbean sprouts rot) and G. cingulata (C. gleosporioides), (apple, pepper). It was remarkable that absorbance value was not reduced even after 4 consecutive washings (Fig.4), suggesting that antigenic determinants are on the surface of conidia. Antigenic determinant was characterized by heating and enzyme treatment: Both PAb1 and PAb2 bind to protein epitope that does not contain residue of amino acid, arginine, and Iysine, even though more work needs to be done.

A Numerical Analysis on Combustion Characteristics of the Gasoline Engine using Methanol Reformulated Fuels under WOT Condition (전부하 운전조건에서 메탄올 개질연료를 사용한 가솔린 엔진의 연소특성에 대한 수치해석)

  • Lee, Suk-Young;Jeon, Chung-Hwan
    • Journal of Energy Engineering
    • /
    • v.20 no.2
    • /
    • pp.163-169
    • /
    • 2011
  • This research is to decide the possibility of using RM50(reformulated methanol fuel) without any modification of engine by the method of numerical analysis. Comparing the heat release rate, the difference among each fuel was decreased according to the increase of the engine speed, and the maximum heat release rate was higher in the order of RM50 and gasoline fuel. Also, this order corresponds to the order of burning speed. RM50 had the higher turbulent burning speed, and the curve of turbulent intensity was showed similar tendency to the curve of turbulent burning speed. RM50 had relatively high burning speed, short quenching length, high temperature in cylinder, so that it might increase NO emission, but owing to chemical reaction dynamics, it was decreased NO emission. Therefore, in order to predict the possibility of using RM50, it is needed to consider not only the temperature in cylinder by low heating value, but also combustion characteristics including burning speed.