• 제목/요약/키워드: Low head and Low Discharge

검색결과 33건 처리시간 0.033초

Counter-Rotating Type Pumping Unit (Impeller Speeds in Smart Control)

  • Kanemoto, Toshiaki;Komaki, Keiichi;Katayama, Masaaki;Fujimura, Makoto
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권3호
    • /
    • pp.334-340
    • /
    • 2011
  • Turbo-pumps have weak points, such as the pumping operation is unstable on the positive slope of the head curve and/or the cavitation occurs at the low suction head. To improve simultaneously both weak points, the first author invented the unique pumping unit composed of the tandem impellers and the peculiar motor with the double rotational armatures. The front and the rear impellers are driven by the inner and the outer armatures of the motor, respectively. Both impeller speeds are automatically and smartly adjusted in response to the pumping discharge, while the rotational torques between both impellers/armatures are counter-balanced. Such speeds contribute to suppress successfully not only the unstable operation at the low discharge but also the cavitation at the high discharge, as verified with the axial flow type pumping unit in the previous paper. Continuously, this paper investigates experimentally the effects of the tandem impeller profiles on the pump performances and the rotational speeds against the discharge, using the impellers whose loads are low and/or high at the normal discharge. The worthy remarks are that (a) the unstable operation is suppressed as expected and the shut off power is scarcely large in the smart control, (b) the blade profile contributes to determine the discharge giving the maximum/minimum rotational speed where the reverse flow may incipiently appears at the front impeller inlet, (c) the tandem impeller profiles scarcely affect the rotational speeds, while the loads of the front and the rear impellers are same, but (d) the impeller with the low load must run faster and the impeller with the high load must run slower at the same discharge to take the same rotational torque, and (e) the reverse flow at the inlet and the swirling velocity component at the outlet of the front impeller with the high load require making the rotational speed of the rear impeller with low load fairly faster at the lower discharge.

절대유량법(ASFM)을 이용한 저낙차.카플란 수차효율측정 적용사례 연구 (Case study of a low head & kaplan turbine efficiency measurement using ASFM)

  • 이용준;오석영;신창식;현정재
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.205.1-205.1
    • /
    • 2011
  • This study concerns a low head and kaplan turbine efficiency measurement using the acoustic scintillation flow meter(ASFM). The ASFM is one of absolute discharge measurement methods because it measures velocity-area of discharge with couples of transducers. This study shows that the highest efficiency of turbine is 87.7% and the efficiency is 85.8% in the rated output(600kW). The test result is reliable because the efficiency trend from this test is similar to the result of index test conducted in 1986. In this paper, the principle, measurement methods, application and test procedures of the test are discussed.

  • PDF

Transitions between Uncontrolled Submerged and Uncontrolled Free in Low-Head Ogee Spillway

  • Hong, Seung Ho;Hong, Da Hee;Song, Yang Heon;Lee, Jeong Myeong;Jegal, Jin A
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.155-155
    • /
    • 2022
  • Low head, ogee spillways is popularly used to defense against floods as well as to provide water for irrigation. Spillway is also used to assess compliance with water quality regulations by controlling amount of discharge to the downstream of a channel. For the purpose of water resource management and/or environmental aspects as explained above, the flow discharge through spillways need to be correctly rated as a function of geometry and hydraulic variables. Typically, four flow conditions are encountered during the operation of spillway: (a) uncontrolled free flow (UF); (b) uncontrolled submerged flow (US); controlled free flow (CF); and controlled submerged flow (CS), and each condition has a unique rating equation. However, one of the tricky part of the spillway operation is finding correct flow type over the spillway because structures can operate under both submerged and free flow conditions, and the types are continuously changing over time depending on the amount of discharge, head water and tail water elevation. Quite obviously, if the wrong rating curve relationship is applied because of misjudgment of the flow type due to a transition, a serious error can occur. Thus, an hydraulic model study of one of spillway structure located in South Florida was conducted for the purpose of developing transition relationships. In this presentation, US to UF transition is highlighted.

  • PDF

5kW급 인라인 마이크로 수차 설계에 대한 연구 (The Study on Design of the 5kW Class Inline Micro-Turbine)

  • 박상언;노형운
    • 한국유체기계학회 논문집
    • /
    • 제15권3호
    • /
    • pp.32-38
    • /
    • 2012
  • This paper is aimed to propose the design database(DB) of the inline micro-turbine for 5kW class. CFD analysis is performed to investigate the effect of a turbine on each parameter. This study showed that RadhaKrishna's data is different from the 5kW class in the low-head and the micro-turbine. Therefore, new DB for the design of inline micro-turbine for 5kW class could be needed. This study configured new design DB for the design of inline micro-turbine for 5kW class. The DB of this study showed that the optimal hub ratio(Dp/DR), the optimal body ratio(Db/DR) and the optimal range of body length ratio(Lh/DR) is 50%, 1.1 and 2.3 to 2.9, respectively.

원뿔형 벤츄리수로의 수리특성 (Hydraulic Characteristics in the Movable Venturi Flume with Circular Cone)

  • 김대근
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.177-184
    • /
    • 2013
  • This study analyzed the hydraulic characteristics of a venturi flume with a circular cone using a 3-D numerical model which uses RANS(Reynolds-Averaged Navier-Stokes Equation) as the governing equation. The venturi flume with the circular cone efficiently measures the discharge in the low-flow to high-flow range and offers the advantage of accurate discharge measurements in the case of a low flow. With no influence of the tail-water depth, the stage-discharge relationship and the flow behaviors were analyzed to verify the numerical simulation results. Additionally, this study reviewed the effect of the tail-water depth on the flow. The stage-discharge relationship resulting from a numerical simulation in the absence of an effect by the tail-water depth showed a maximum margin of error of 4 % in comparison to the result of a hydraulic experiment. The simulation results reproduced the overall flow behaviors observed in the hydraulic experiment well. The flow starts to become influenced by the tail-water depth when the ratio of the tail-water depth to the total head exceeds approximately 0.7. As the ratio increases, the effect on the flow tends to grow dramatically. As shown in this study, a numerical simulation is effective for identifying the stage-discharge relationship of a venturi flume with various types of venturi bodies, including a venturi flume with a circular cone.

경사형 및 계단형 보의 유량계수 산정을 위한 실험연구 (Experimental study on the discharge coefficient of slope-type and step-type weirs)

  • 강준구;김종태
    • 한국수자원학회논문집
    • /
    • 제49권12호
    • /
    • pp.961-969
    • /
    • 2016
  • 최근 들어 보의 환경적인 측면을 고려한 저낙차형 구조물 설치가 요구되면서 고정보의 형태도 다양하게 제안되고 있다. 그러나 실무에 적용하기 위한 횡단구조물의 설계 가이드라인은 매우 한정적이다. 따라서 본 연구는 국내 중소하천에 설치된 고정보의 물리적 제원 변경에 의한 수리적 특성을 분석함으로써 환경적인 측면을 고려한 저낙차형 고정보의 유량계수 산정을 위한 기초자료를 제공하는데 목적이 있다. 이를 위해 경사형 및 계단형 보에 대해 crest 변화에 따른 기본적인 유량계수를 도출하였으며 수위-유량 관계 곡선을 개발하였다. 또한 유량과 crest 등과 같은 수리학적조건을 변화시켜 자유 흐름 조건 및 잠긴 흐름 조건의 흐름특성을 분석하였다.

Investigation on the Internal Flow Characteristics of the Low Specific Speed Centrifugal Pump with Circular Casing

  • Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.404-412
    • /
    • 2008
  • As a suitable volute configuration in the range of low specific speed, circular casing is suggested in this study. The internal flows in a centrifugal pump with the circular and spiral casings are measured by PIV and analyzed by CFD. The results show that the head and efficiency of the pump by a circular casing of very small radius are almost same as those by the spiral casing. Even at the best efficiency point, the internal flow of the pump by circular casing is asymmetric, and vortex and strong secondary flow occurs in the impeller passage. The radial velocity becomes higher remarkably only near the region of the discharge throat. The flow in the impeller outlet is strongly controlled by the circular casing because the velocity distribution almost does not affected by the position of the impeller blades.

부분방전 신호 검출 시 노이즈 제거방법 (The Noise Removal Methode of Partial Discharge Signal)

  • 최문규;차한주
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1436-1441
    • /
    • 2016
  • Currently, partial discharge diagnosis in the field of prevention applied technology and diagnostic equipment is a possible strong limit to remove the noise generated by external or internal I still have one unreliable diagnosis. This technology is the noise removal from signal the time lag analysis algorithms technique is applied by a fundamental. Increasing the reliability in terms of technology spectrum frequence of analysis method for by applying the acquisition through the position of the frequency content and sources of traffic lights partial discharge of the acquisition of signal analysis to judge whether a way diagnosis the environment of the scene, and conditions. Partial discharge signal and make the discharge while building blocks were found through the Analysis. Spectrum frequence of Analysis and wide discharge part, to be more precise, in line with the various functions, including the analysis technique band. Diagnosis and comes up with advanced technology that can detect the presence of a position. This method is portable single device developed for maintenance and mobility and ease and convenience of getting caught by discharge of the pattern analysis and position detection method suitable for a new diagnosis will suggest.

Tolerability and Effect of Early High-Dose Amino Acid Administration in Extremely Low Birth Weight Infants

  • Choi, Jin Wha;Kim, Jisook;Ahn, So Yoon;Chang, Yun Sil;Park, Won Soon;Sung, Se In
    • Neonatal Medicine
    • /
    • 제25권4호
    • /
    • pp.153-160
    • /
    • 2018
  • Purpose: The aim of this study is to examine the tolerability and effect of early high-dose amino acid administration in extremely low birth weight infants (ELBWIs). Methods: This retrospective cohort study included ELBWI (birth weight <1,000 g, n=142). Biochemical, nutritional, and neurodevelopmental data were compared between infants who received conventional low amino acid (LAA; 1.5 g/kg/day) and those who received high amino acid (HAA; 3 g/kg/day) within the first 48 hours after birth. Neurodevelopmental data included weight, height, and head circumference at discharge, 12 to 14 and 18 to 24 months of corrected age and the Korean Bayley Scale of Infant Development II (K-BSID-II) score at 18 to 24 months of corrected age. Results: The HAA group demonstrated higher peak plasma albumin ($3.0{\pm}0.4$ vs. $3.2{\pm}0.5$, P<0.05) and lower serum creatinine ($1.7{\pm}0.9$ vs. $1.4{\pm}0.8$, P<0.05) during the first 14 days than the LAA group. Full enteral feeding was achieved significantly earlier in infants in the HAA group than in infants in the LAA group ($46.2{\pm}23.0days$ vs. $34.3{\pm}21days$, P<0.01). There was no difference between the two groups in the z score changes in all growth indicators from birth to discharge and at 12 to 14 and 18 to 24 months of corrected age, as well as in the K-BSID-II score at 18 to 24 months of corrected age. Conclusion: Aggressive administration of amino acids during the first 2 days of life in ELBWI was well tolerated and correlated with earlier full enteral feeding, but did not improve growth and neurodevelopment.

왕복동 압축기의 소음 및 진동 기여도 분석 (Coherence Analysis of Noise and Vibration For Reciprocating Compressor)

  • 이대성;황원걸;이유엽;임형은
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.875-880
    • /
    • 2002
  • It is necessary to determine the vibration source and its transmission paths in order to develop a low-noise compressor. Through the use of multiple-input/single-output(MISO) mode1, the transmission paths of vibration within a reciprocating compressor have been investigated. In order to identify the transmission path, we measure the accelerations of the block and transverse vibrations of the line discharge tube. As outputs, vibrations of compressor shell were measured at three positions; cylinder head, one near the suction line, and the top of upper shell. The partial coherence function and transfer function are obtained ken the measured data, and the results are observed in order to determine vibration source and its influence on the shell vibration.

  • PDF