Browse > Article
http://dx.doi.org/10.5293/kfma.2012.15.3.032

The Study on Design of the 5kW Class Inline Micro-Turbine  

Park, Sang-Eun (인천대학교 공과대학 기계시스템공학과)
Roh, Hyung-Woon ((주)아이베이)
Publication Information
Abstract
This paper is aimed to propose the design database(DB) of the inline micro-turbine for 5kW class. CFD analysis is performed to investigate the effect of a turbine on each parameter. This study showed that RadhaKrishna's data is different from the 5kW class in the low-head and the micro-turbine. Therefore, new DB for the design of inline micro-turbine for 5kW class could be needed. This study configured new design DB for the design of inline micro-turbine for 5kW class. The DB of this study showed that the optimal hub ratio(Dp/DR), the optimal body ratio(Db/DR) and the optimal range of body length ratio(Lh/DR) is 50%, 1.1 and 2.3 to 2.9, respectively.
Keywords
Micro Turbine; Energy; Inline; Low head and Low Discharge; CFD;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 IEC60041 International Standard 3rd Ed., 1991, "Field Accepatance Tests to Determine the Hydrualic Performance of Hydraulic Turbines," Strorage Pumps and Pumps- Turbines.
2 수차 유동특성분석(CFD)을 통한 설계기술 향상 및 성능 개선 연구, 2010, 한국수자원공사.
3 카플란 수차 설계기술 및 국산화 개발, 1996-N-SH02- P-01, 산업자원부.
4 수도관 차압을 이용한 마이크로 소수력 발전 실용화 기술개발, 2006-N-SH02-P-02, 지식경제부.
5 Radha Krishna H. C. 1997, "Hydraulic Design of Hydraulic Machinery," Published by Avebury.
6 ANSYS-CFX11 Manual, ANSYS.
7 김정욱, 김호찬, 부창진, 2011, "혁신도시 신재생에너지 도입연구," J. of the Korea Academia-Industrial Cooperation Society, Vol. 12, No. 5, pp. 2254-2260.   DOI
8 이의준, 2011, "신재생에너지 프로젝트 에너지 및 온실가스 저감량 국제 평가도구 RETScreen 소개," 기계저널, Vol. 51, No. 5, pp. 35-39.
9 오석영, "4대강 수자원설비 현황소개," 4대강 수자원설비 워크숍, Kwater 댐유역관리처.
10 한국남동발전(주) 입찰공고 제PYC-I-BM26호. 영흥화력5, 6호기 해양수력 발전설비 구매.