• Title/Summary/Keyword: Low grade heat source

Search Result 37, Processing Time 0.018 seconds

Optimum Pumping Rates of Ground-Water Heat Pump System Using Groundwater or Bank Infilterated Water (강변여과수와 천부 지하수를 이용하는 지하수 열펌프시스템의 적정유량)

  • Hahn, Jeong-Sang;Han, Hyuk-Sang;Hahn, Chan;Jeon, Jae-Soo;Kim, Hyong-Soo
    • Economic and Environmental Geology
    • /
    • v.40 no.6
    • /
    • pp.833-841
    • /
    • 2007
  • The groundwater heat pump system(GWHP) is one of the most efficient ground source heat pump system(GSHP) which uses low grade and shallow geothermal energy for cooling and heating purpose. The GWHP system shall be designed properly based on peak block load performance and optimum pumping rate of groundwater comparable to ground coupled heat pump system(GCHP). The optimum pumping rate depends on groundwater temperature at a specific site, size of plate heat exchanger, and total head loss occurred by whole system comprising pumps and pipings. The required optimum flow rates of the system per RT are ranged from 3.8 to 9.8lpm being less than the typical building loop flow of 9.5 to 11.4lpm.

Effect on the Cycle by the Properties of Working Fluids Using Organic Rankine Cycle (유기랭킨사이클의 작동유체 물성치가 사이클에 미치는 영향에 관한 연구)

  • Cho, Soo-Yong;Cho, Chong-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.4
    • /
    • pp.5-12
    • /
    • 2015
  • Several working fluids for Organic Rankine Cycle(ORC) were recommended by many researchers. However, the recommended optimal working fluids were not exactly same because the operating conditions of ORC and application were different. The major parameter to select the working fluid for ORC was the temperature of available thermal energy. In this study, low-grade thermal energy was used for the heat source for ORC and the appropriate working fluids were searched among 26 candidate working fluids. The requirements to be a working fluid for ORC were reviewed and the cycle analysis for simple cycle was conducted with $75^{\circ}C$ and $35^{\circ}C$ at the turbine inlet and exit, respectively. R600, R601, toluene were best candidates if the system could work without leaking the working fluid. Next, R236ea, R245ca, R245fa were recommended because they are not inflammable working fluids as well as better efficiency.

"A survey of Elementary School Children,s Concept of Temperature" (국민학교 아동의 온도개념 형성에 관한 조사)

  • Kim, Hyun-Jae;Kim, Han-Ho
    • Journal of The Korean Association For Science Education
    • /
    • v.10 no.1
    • /
    • pp.95-118
    • /
    • 1990
  • This students ideas in science are diverse and unique It is realized that children's preconceptions and misconceptions established before lessoning hgve a crucial in fluence on the following education. so it is meaningful to analyse the children's concept of temperature for the better teaching strategy in this study. This survey of the Elementary school children's concept is designed for the subtopics of temperature as the relation between heat and temperature, He relation between volume(size) and temperature, the temperature of change of state on water, the temperature of substances in the condition of thermal equilibrium. Using Clinical method, this research was executed to 306 children at elementary school. The network method or the analyse of questionnaires were used to analyse the children's response. Findings of this survey are as follow. Students are already familiar with such concept as this increase of temperature by geating, but they think every substance is not the case. Many students appears to believe that the temperature of an object(substance) is related to its size(vloume) Qualitative tasks are difficult than qualitative ones. This trend appear highly in the low grade students. Don't know the temperature of change of state on water and it's stability They think that the temperature is determined by the heating time(period) and the temperature of heating source. Students think, in general that temperature of substance in the condition of thermal equilibrium is different.

  • PDF

Experimental Study on the Performance Characteristics of a Scroll Expander for 1kW-class Organic Rankine Cycle (1kW급 유기랭킨사이클용 스크롤 팽창기의 성능 특성에 관한 실험적 연구)

  • Kim, Dokyun;Yun, Eunkoo;Yoon, Sang Youl;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.41-48
    • /
    • 2015
  • The performance characteristics of a scroll expander is the most important variable for the performance of organic Rankine cycle system. In this paper, the performance characteristics of a scroll expander was identified using 1kW class organic Rankine cycle system with various operating conditions. The ORC system is composed of an evaporator, a scroll expander, a condenser and a working fluid feed pump that uses R245fa as working fluid. The hot water temperature was controlled from $80^{\circ}C$ to $115^{\circ}C$ by the 50kW-class electric water-heater. The maximum isentropic efficiency of the scroll expander was measured about 77%, and the shaft power was measured from 0.5 kW to 1.8 kW according to heat source temperatures.

The study on Coal Spontaneous Ignition Prevention using Safety Materials of Food and Cosmetics (식품과 화장품의 안전 소재를 이용한 석탄 자연발화 억제에 대한 연구)

  • Jun, Soo-Man;Kim, Young-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.2
    • /
    • pp.368-376
    • /
    • 2022
  • Spontaneous ignition occurs in industrial sites or anywhere in our lives, and is a phenomenon in which a substance ignites itself without an ignition source in the atmosphere. As the rate of chemical reaction increases, the heat generated increases, and the risk of spontaneous ignition increases. In this study, safe raw materials used for food and cosmetics were mixed to prepare coal spontaneous ignition prevention agents specifically among various spontaneous ignition phenomena. The effect of suppressing spontaneous combustion of coal was confirmed through lab and field tests with low-calorie, low-grade coal from Indonesia. As a result of the outdoor field test, the ignition prevention agent manufactured in this study compared with the control group(Fire after 90 days) showed excellent ignition inhibitors for more than 120 days. In addition, CO concentration control was confirmed by comparing the concentration of carbon monoxide for 50 days at the indoor coal yard. It was confirmed that the results were better than the comparative group coal and the existing anti-firing method. In addition, the possibility of coal fire prevention agents for indoor coal farms will be applied from 2024 was confirmed by studying the environment and safety of workers' working environments through official test such as soil and water quality test, MSDS of coal fire prevention agents in consideration of working workers, water quality, and eye irritation tests.

Performance Characteristics of Organic Rankine Cycles Using Medium Temperature District Heating Water as Heat Source (지역난방용 중온수 열원 유기랭킨사이클 성능 특성)

  • Park, Woo-Jin;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2016
  • It is becoming increasingly important to make use of alternative energy source. because It is not able to rely on only fossil fuel for the recent increasing demand of energy consumption. With this situation, lots of studies for utilizing low grade energy such as industrial waste heat, solar energy, and geothermal energy have been conducted. The aim of this study is to predict the operation characteristics of working fluid by using performance analysis program (ThermoFlex) through the system analysis which is not mixing district return water but using ORC(Organic Rankine Cycle, hereinafter ORC) as a downstream cycle when accumulating district heating (hereinafter DH). In this study, We conducted the performance analysis for the case which has the district heating water temperature($120^{\circ}C$) and Flow rate of $163m^3/h$ (including District Heating return water flow), and examined several working fluid which is proper to this temperature. The case using R245fa (which is the best-case) showed 269.2kW power output, 6.37% efficiency. Additionally, Cut down on fuel was expected because of the boiler inlet temperature increase by being Formed $57.3{\sim}85^{\circ}C$ in a temperature of district heating return water, depending on a pressure change of a condenser in ORC system.

  • PDF

Prevalence of Enteyobius vermiculuris infection and preventive effects of masts treatment among children in rural and urban areas, and children in orphanages (농촌, 도시 및 집단생활 아동의 요충 감염과 집단 구충에 의한 예방 효과)

  • Kim, Jong-Su;Lee, Hae-Yong;An, Yeong-Gyeom
    • Parasites, Hosts and Diseases
    • /
    • v.29 no.3
    • /
    • pp.235-244
    • /
    • 1991
  • An epidemiological study and mass treatments of Enterobius vermicularis infection among children near Wonju area of Kangwon province were carried out. The children were divided into 4 groups according to their residing localities; children in the mountainous area, rural area, urban area and in orphanage. They were examined by adhesive cellotape anal swab technique, and egg positive rates were obtained. The rates of egg reduction and re-infection rates after repeated mass treatments were also observed. The results obtained were as follows: 1. The overall egg Positive rate of E. vermicularis in the first screening was 19.9% (251 out of 1, 262 examinees; 19.7% in males and 20.1% in females). The positive rates were 13.0% in the mountainous area, 11 9% in the rural area, 15.1% in the urban (medium-sized) area and 61.9% in orphanages. 2. The highest positive rates were observed in the kindergarten children, and 1st and 2nd grade children of primary schools (26.2~32.2%), and the lowest rate (13.6%) in 6-year grade children of primary schools. 3. Cumulative detection rates from 3 repeated anal swabs at 4~5 days interval were higher (70.8%) than those from single anal swabs (50.0~59.2%). 4. Out of the examinees who showed the highest cumulative positive rate (70.8%), about 39.2% were consecutively positive in 3 anal swabs. Among different groups of children, the higher the total egg detection rates (87.5%), the higher the consecutive positive rates (71.9%) . 5. A total of 2, 609 (male : female=1 : 12.4) worms were collected from 17 egg-positive cases treated with anthelinintics. The mean number of worms per child was 153 (range: 4-824) . 6. The egg-positive cases in several studied groups (180 children) were treated with anthelmintics 6 times at 3-week intervals. In this case, the overall positive rate was decreased from 54.8% to 2.2% at 15 weeks after the treatments, but no complete negative conversion was experienced. However, in a group of children (154 children) including egg Positive and negative cases who were both treated with anthelmintics at 3-week interval, a complete egg-negative conversion was observed in the 9th week after treatments. 7. The egg-detection rate in the brothers or sisters of egg Positive children was 70.0% (28 out of 40 examined), and the egg-positive rate according to the family unit was 69.7%. In summarizing the above results, it is concluded that Enterobius vermicularis infection is still highly prevalent among children in Korea, and that repeated mass treatments of more than 3 times will be effective for control of this infection.

  • PDF