• Title/Summary/Keyword: Low frequency electrical stimulation

Search Result 90, Processing Time 0.028 seconds

Low-Frequency Haptic Interface Developed for Electrical Safety Experience Education

  • Cho, Hyun-Seob
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.1
    • /
    • pp.75-78
    • /
    • 2015
  • Electric shock due to the increased use of power, equipment accidents, electrical accidents, such as electric fire and also continues to grow. To prevent electric shock accidents, an experience education is more effective than indoctrination education. But an electric shock experience education system required a proper physical stimulation on human body to experience electric shock. In this study, we conducted a study to take advantage of the realistic haptic interface using a low-frequency type experiential learning and prevention education. Results of this study could be applied to an electric shock experience education system.

The Effect of Electrical Acupuncture of High and Low Frequencies on Glucose, Immunoglobulin G and Cholesterol in Diabetic Rats (고빈도 및 저빈도 전침이 당뇨쥐의 혈당과 면역글로불린 G 및 콜레스테롤 농도에 미치는 영향)

  • Park, Mi-Hee;Kim, Eun-Young;Rho, Min-Hee;Kim, Jai-Young
    • Physical Therapy Korea
    • /
    • v.14 no.2
    • /
    • pp.37-43
    • /
    • 2007
  • Electrical acupuncture has been shown to induce hypoglycemic effect in streptozotocin diabetic rats. The Zusanli acupoints have been widely used in traditional Chinese medicine to relieve symptoms of diabetes mellitus. But, the effects of electrical acupuncture stimulation of different frequencies are still unclear. We designed an experiment to investigate the effect of electrical acupuncture of high (100 Hz) and low (2 Hz) frequencies on Zusanli acupoint for 15 minutes in streptozotocin diabetic rats. They were divided into 4 groups, high frequency electrical acupuncture (HFEA group, n=5), low frequency electrical acupuncture (LFEA group, n=5), without any treatment (control group, n=5) and normal group (n=5). After 2 weeks of treatment, the HFEA and LFEA groups had a significantly decreased glucose concentration in serum in comparison to the control group. Additionally, the HFEA group had a significantly decreased glucose concentration in serum compared with the LFEA group. Both the HFEA and LFEA groups had a significantly decreased Immunoglobulin G concentration in serum compared with control group. The LFEA and control groups had a significantly increased cholesterol concentration in serum compared with the normal group, but the HFEA did not have a significantly increased cholesterol concentration. Thus we suggest that electrical acupuncture stimulation at the Zusanli acupoints is effective on hypoglycemic effect and immune function. Overall, the therapeutic effects of electrical acupuncture at 100 Hz was better than effects at 2 Hz.

  • PDF

An Exercise Program for Paralyzed Muscles Employing Electrical Stimulation (전기자극에 의한 마비 근육의 훈련 프로그램)

  • Khang, Seon-Hwa;Khang, Gon
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.179-183
    • /
    • 1997
  • The objective of this study was to develop an FES exercise protocol that can enhance muscle force and fatigue resistance and to evaluate the resulting effects. We investigated contraction and fatigue properties of vasti of 10 normal subjects and 4 paraplegics by applying different types of electrical stimulation. Based on the results, we have been training quadriceps of a male paraplegic patient. The results suggested that the exercise be applied 7 days a week, and confirmed that low frequency and intermittent stimulation delays fatigue. After the two-year FES exercise, the patient's knee extensor torque increased by about ten folds and the fatigue index decreased to half of the preFES value.

  • PDF

The Effect of Frequency of Transcutaneous Electrical Nerve Stimulation (TENS) on Maximum Multi-finger Force Production

  • Karol, Sohit;Koh, Kyung;Kwon, Hyun Joon;Park, Yang Sun;Kwon, Young Ha;Shim, Jae Kun
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.1
    • /
    • pp.93-99
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the effect of transcutaneous electrical nerve stimulation (TENS) treatment on maximum voluntary force (MVF) production. Methods: Ten healthy, young subjects (5 males and 5 females) participated in the study. MVF was recorded after a fifteen minute session of TENS stimulation under two conditions: low frequency (4 Hz) at maximum tolerable level and high frequency (110 Hz) at maximum tolerable level. TENS was provided simultaneously via self-adhesive electrodes placed on the finger pads of the index, middle, ring and little fingers. MVF was also recorded in a baseline condition with no TENS treatment. Data were collected in three different sessions on three consecutive days at the sametime of the day. Results: Results from the study show that on an average, MVF increasesby 25% for the index, middle and little fingers for TENS treatment with 4 Hz frequency as compared to the baseline condition. However, the 110 Hz condition did not result in a significantly different MVF than the baseline condition during individual finger pressing tasks. In addition, while producing MVF with all the four finger stogether, MVF was 30% higher for the 4 Hz conditionin comparison to the baseline condition, and 15% higher for the 110 Hz condition in comparison to the baseline condition respectively. Conclusion: The results suggest that stimulation ofafferent fibers onthe glabrous skinwith TENS could have a net facilitatory effect on the maximum motoroutput.

A Comparative Study of Motor Recovery from Stroke between High and Low Frequency Electrical Acupoint Stimulation (뇌경색 환자의 운동장애에 대한 주파수별 전침치료효과의 비교)

  • Kim, Young-Suk;Jung, Woo-Sang;Na, Byung-Jo;Park, Seong-Uk;Moon, Sang-Kwan;Park, Jung-Mi;Ko, Chang-Nam;Cho, Ki-Ho;Bae, Hyung-Sup;Hong, Jin-Woo
    • The Journal of Korean Medicine
    • /
    • v.28 no.3 s.71
    • /
    • pp.289-298
    • /
    • 2007
  • Objectives : Electrical acupoint stimulation (EAS) has been used to treat motor dysfunction of stroke patients with reportedly effective results. The purpose of this study was to evaluate the efficacy of EAS with different frequencies in treating motor dysfunction of ischemic stroke patients. Methods : The subjects of this study were sixty-two ischemic stroke patients with motor dysfunction at Kyunghee Oriental Medicine Hospital who were hospitalized for one week to one month from onset. They were treated with 2Hz or 120Hz EAS for two weeks, and motor evoked potentials (MEP) were measured before and after EAS treatment. To compare the effect of 2Hz EAS with 120Hz, we measured latency, central motor conduction time (CMCT) and amplitude of MEP before and after EAS treatment. Results : After two weeks of treatment, we compared MEP data of the affected side between the 2Hz group and the 120Hz group. The 2Hz group showed more significant improvement than the 120Hz group in latency, CMCT and amplitude (P=0.008, 0.002, 0.002). In case of the affected side MEP data divided by normal side MEP data, the 2Hz group also showed improvement on latency, CMCT and amplitude with significant differences (P=0.003, 0.000, 0.008). Conclusions : These results suggest that low frequency EAS activates the central motor conduction system better than high frequency EAS, and it means that EAS with low frequency is more helpful for motor recovery after ischemic stroke than that with high frequency.

  • PDF

Electric Corrosion of STS304 Acupuncture Needles Used for Electroacupuncture (STS304 스테인리스 강선 호침에서 전침 자극 후 침체에 나타나는 전기적 부식 연구)

  • Hwang, Hye-Suk;Koo, Sung-Tae;Ryu, Yeon-Hee;Jeong, Sang-Yong;Kim, Yu-Sung;Lee, Ji-Eun;Han, Kyung-Ju;Choi, Sun-Mi
    • Journal of Acupuncture Research
    • /
    • v.24 no.5
    • /
    • pp.105-111
    • /
    • 2007
  • Objectives : The electroacupuncture(EA) was often used in Oriental medicine clinic and basic researches. However, there have been neither any national standard of acupuncture needles in Korea nor many studies about the property of acupuncture needles for applying electrical stimulations. Therefore we investigated the electrical corrosion property of acupuncture needles used for EA stimulation in clinic. Methods : We observed the occurrence of electrical corrosion like changes in the surface of acupuncture needles after EA stimulation with various parameters(electrical stimulation intensity, treatment duration, diameter of needle) under a light microscope. We performed EA stimulation on Baekhoe($GV_{20}$) or Joksamli($ST_{36}$) of rats with intensity of 0.025, 0.05, 0.075, 0.1, 0.25 or 0.5mA at a 10Hz frequency. Results : The electrical corrosion-like changes were found on the surface of needles when the EA stimulation was given over 0.05mA of intensity. When electrical stimulation was treated for 10min, the electrical corrosion-like changes were low, but the electrical corrosion-like changes gradually increased by the treatment duration(20, 30min). We also found that acupuncture needles of 0.2mm diameter were produced more extensive electrical corrosion-like changes than acupuncture needles of 0.3 or 0.4mm diameter by electrical stimulation. Conclusions: These results suggested that EA stimulation could produce electrical corrosion-like changes of acupuncture needles through intensity of current, duration of electric stimulation and/or diameter of needle.

  • PDF

Development of Multi-wavelength Laser Medical Therapy Apparatus (다파장 레이저치료기의 개발)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Lee, Ho-Sik;Kim, Tae-Gon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.736-741
    • /
    • 2007
  • Low level laser therapy has various therapy effects, This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 660nm, 785nm and 850nm laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. To raise the stimulus effect of the human body, the optical irradiation frequency could be set up. In result, the $1{\sim}10\;Hz$ irradiation frequency could be controlled stably.

The Impacts of Muscle Energy Technique (MET) and Transcutaneous Electrical Nerve Stimulation (TENS) Performed on Elector Spinae Muscle of Acute Low Back Pain Patients on Pain and Meridian Electromyography (경근추나요법과 경피전기자극치료가 급성 요통 환자의 통증 및 척추기립근 경근전도에 미치는 영향)

  • Kim, Soon-Joong;Park, Dong-Su;Jeong, Su-Hyeon;Ahn, Jae-Min
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.24 no.1
    • /
    • pp.83-92
    • /
    • 2014
  • Objectives To evaluate the clinical usefulness between muscle energy techniques (MET) and transcutaneous electrical nerve stimulator (TENS), we performed both on elector spinae muscle of acute low back pain patients. Methods After performing MET and TENS, we compared both in terms of electrical activity. We performed MET or TENS on elector spinae muscle of acute low back pain patients in each group (n=15,15). After performing MET or TENS, we analyzed root mean square (RMS), median edge frequency (MEF) and asymmetry index (AI). Results 1. After performing MET on elector spinae muscle of acute low back pain patients, RMS was significantly decreased compared with before (p<0.005). 2. After performing TENS on elector spinae muscle of acute low back pain patients, RMS was significantly decreased compared with before (p<0.005). 3. After performing MET on elector spinae muscle of acute low back pain patients, asymmetric index was significantly decreased compared with before (p<0.05). Conclusions According to above results, performing MET on elector spinae muscle of acute low back pain patients has effect in terms of RMS and asymmetric index. And performing TENS on elector spinae muscle of acute low back pain patients also has similar effect in terms of RMS but has not in terms of asymmetric index.

The Effect of Microcurrent Stimulation on Pain and Quality of Life in Women with Primary Dysmenorrhea

  • Minkyoung Kwon;Wonjae Choi
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.3
    • /
    • pp.293-299
    • /
    • 2023
  • Objective: This study aimed to investigate the potential benefits of microcurrent stimulation as a non-invasive therapeutic approach for managing pain and improving the quality of life in women suffering from primary dysmenorrhea. Design: A case study. Methods: This study was conducted, involving a cohort of 6 women diagnosed with primary dysmenorrhea, aged between 20 to 30 years. Participants were received microcurrent stimulation using low-intensity microcurrents for 30 minutes every day for 4 weeks. The intensity of microcurrent stimulation was 25 μA and the frequency was 8 Hz. The intervention was administered between the menstruations, with pain intensity and quality of life being assessed at baseline, and then at the end of menstrual cycle. Pain intensity was evaluated using a visual analog scale (VAS) and menstrual symptom questionnaire (MSQ), while the quality of life was assessed through the stress response inventory (SRI), state trait anxiety inventory (STAI), center for epidemiologic studies depression (CES-D), and menstrual distress questionnaire (MEDI-Q). Results: After the intervention, participants demonstrated a statistically significant reduction in pain intensity, as evidenced by improved VAS scores (p<0.05). However, the changes in MSQ scores did not reach statistical significance. Regarding quality of life measures, no statistically significant differences were found in the SRI, STAI, CES-D, and MEDI-Q scores after the intervention (p>0.05). Conclusions: This study suggest that microcurrent stimulation holds promise as a potential treatment option for alleviating pain associated with primary dysmenorrhea.

Characteristics of Optical Power of Low Level Laser Apparatus (저출력 레이저 치료기의 광 출력 특성)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Kim, Yong-Pil;Yu, Seong-Mi;Park, No-Bong;Lee, Hee-Gab
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.496-496
    • /
    • 2007
  • Low level laser has various therapy effects. This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 660nm Laser diode for blood stream improvement and was designed for a pulse width modulation type to increase stimulation effects. In result, we could get the light power of 660nm wavelength and the 1~10Hz irradiation frequency could be controlled stably.

  • PDF