• 제목/요약/키워드: Low frequency

검색결과 11,387건 처리시간 0.039초

Study on Hybrid PWM Method under Low Switching Frequency

  • Kekang, Wei;Zheng, Trillion Q.;Wang, Ran;Wang, Chenchen
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권2호
    • /
    • pp.64-69
    • /
    • 2012
  • This paper presents a hybrid pulse width modulation (PWM) method under low switching frequency conditions based on space vector PWM (SVPWM) and selective harmonic eliminated PWM (SHEPWM), which use asynchronous carrier modulation SVPWM at low frequency, and SHEPWM at high frequency, a square wave after rated conditions. A transitive strategy is proposed to realize a smooth transition of individual modes including SVPWM, SHEPWM and square waves. Experimental results confirm this hybrid modulation method and their transition are reasonable and proper.

플라즈마 파동의 분산관계 측정에 관한 연구 (Measurement of Dispersion Relation of Plasma Wave)

  • 정중현;이종규
    • 수산해양기술연구
    • /
    • 제33권3호
    • /
    • pp.248-258
    • /
    • 1997
  • The analytical solutions of the Fraunhofer Diffraction(FD) theory and the principle for measurement of the dispersion relation of plasma wave is presented. Especially, the method for measurement of low-frequency wave is discussed. The wavenumbers of the density fluctuations are obtained from the curve fitting between the expremental FD profile and theoretical one for each frequency component. In measurement of the wavenumber of the low -frequency region, the information of the wavenumber is easily obtained from the ratio of the intensity at = 0 to the intensity at =0.5. The millimeter wave FD apparatus was designed to measure low-frequency density fluctuations. The determined wavenumbers are in the range of =0.1~ 1.0cm. Thus, the millimeter wave FD method was shown to be useful for the measurement of low-frequency density fluctuations, which are impossible to be measured by using a convention. Thomson scattering. The obtained dispersion relations will be useful information for plasma waves.

  • PDF

Parameter Estimation Method of Low-Frequency Oscillating Signals Using Discrete Fourier Transforms

  • Choi, Joon-Ho;Shim, Kwan-Shik;Nam, Hae-Kon;Lim, Young-Chul;Nam, Soon-Ryul
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.163-170
    • /
    • 2012
  • This paper presents a DFT (Discrete Fourier Transform) based estimation algorithm for the parameters of a low-frequency oscillating signal. The proposed method estimates the parameters, i.e., the frequency, the damping factor, the mode amplitude, and the phase, by fitting a discrete Fourier spectrum with an exponentially damped cosine function. Parameter estimation algorithms that consider the spectrum leakage of the discrete Fourier spectrum are introduced. The multi-domain mode test functions are tested in order to verify the accuracy and efficiency of the proposed method. The results show that the proposed algorithms are highly applicable to the practical computation of low-frequency parameter estimations based on DFTs.

Proposing a low-frequency radiated magnetic field susceptibility (RS101) test exemption criterion for NPPs

  • Min, Moon-Gi;Lee, Jae-Ki;Lee, Kwang-Hyun;Lee, Dongil
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1032-1036
    • /
    • 2019
  • When the equipment which is related to safety or important to power production is installed in nuclear power plant units (NPPs), verification of equipment Electromagnetic Susceptibility (EMS) must be performed. The low-frequency radiated magnetic field susceptibility (RS101) test is one of the EMS tests specified in U.S NRC (Nuclear Regulatory Commission) Regulatory Guide (RG) 1.180 revision 1. The RS101 test verifies the ability of equipment installed in close proximity to sources of large radiated magnetic fields to withstand them. However, RG 1.180 revision 1 allows for an exemption of the low-frequency radiated magnetic susceptibility (RS101) test if the safety-related equipment will not be installed in areas with strong sources of magnetic fields. There is no specific exemption criterion in RG 1.180 revision 1. EPRI TR-102323 revision 4 specifically provides a guide that the low-frequency radiated magnetic field susceptibility (RS101) test can be conservatively exempted for equipment installed at least 1 m away from the sources of large magnetic fields (>300 A/m). But there is no exemption criterion for equipment installed within 1 m of the sources of smaller magnetic fields (<300 A/m). Since some types of equipment radiating magnetic flux are often installed near safety related equipment in an electrical equipment room (EER) and main control room (MCR), the RS101 test exemption criterion needs to be reasonably defined for the cases of installation within 1 m. There is also insufficient data regarding the strength of magnetic fields that can be used in NPPs. In order to ensure confidence in the RS101 test exemption criterion, we measured the strength of low-frequency radiated magnetic fields by distance. This study is expected to provide an insight into the RS101 test exemption criterion that meets the RG 1.180 revision 1. It also provides a margin analysis that can be used to mitigate the influence of low-frequency radiated magnetic field sources in NPPs.

Anti-inflammatory Effects of Low-frequency Stimulator using Superposition of Alternating Microcurrent Wave in the Animal Models

  • Kim, Yoo-Jeong;Lee, Seong gwang;Go, Shin Jee;An, Suyeon;Kim, Ye eun;Kim, Ye in;Hyun, Kyung-Yae;Cho, Dong Shik;Choi, Go-Eun
    • 대한의생명과학회지
    • /
    • 제27권2호
    • /
    • pp.99-104
    • /
    • 2021
  • Treatment techniques that affect homeostasis by non-invasive regulation in peripheral organs will advance disease research. Here, we demonstrate a non-invasive method of conditioning within an organ using a low-frequency stimulator superposition of alternating microcurrent wave in stages. It is first applied to the inflammatory response in H3N2-infected sinusitis mice. To check the progress of the treatment, mice were sacrificed every week for 3 weeks, nasal tissue was removed, and the inflammatory response was investigated through H & E staining. The low-frequency stimulation treatment group was found to alleviate the proliferation of epithelial cells and invasion of inflammatory cells compared to the control group as the passage of treatment time. The reduction of inflammatory cytokines in the nasal lavage fluid was observed in H3N2-infected sinusitis mice treated with of low-frequency stimulation using superposition of alternating microcurrent wave compared to H3N2-infected sinusitis mice after 3 weeks. These data demonstrate that low-frequency stimulation device in the form of using alternating current wave superposition on within organs provides a new method to regulate specific physiological functions. Therefore, it is necessary to prove the inhibitory effect of low-frequency stimulation using alternating current wave superposition on inflammatory diseases by various methods through further studies and clinical studies.

CR 영상에서 기저선 보정을 위한 1차원 모폴로지컬 필터의 이용에 관한 연구 (Baseline Correction in Computed Radiography Images with 1D Morphological Filter)

  • 김용권;류연철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권5호
    • /
    • pp.397-405
    • /
    • 2022
  • Computed radiography (CR) systems, which convert an analog signal recorded on a cassette into a digital image, combine the characteristics of analog and digital imaging systems. Compared to digital radiography (DR) systems, CR systems have presented difficulties in evaluating system performance because of their lower detective quantum efficiency, their lower signal-to-noise ratio (SNR), and lower modulation transfer function (MTF). During the step of energy-storing and reading out, a baseline offset occurs in the edge area and makes low-frequency overestimation. The low-frequency offset component in the line spread function (LSF) critically affects the MTF and other image-analysis or qualification processes. In this study, we developed the method of baseline correction using mathematical morphology to determine the LSF and MTF of CR systems accurately. We presented a baseline correction that used a morphological filter to effectively remove the low-frequency offset from the LSF. We also tried an MTF evaluation of the CR system to demonstrate the effectiveness of the baseline correction. The MTF with a 3-pixel structuring element (SE) fluctuated since it overestimated the low-frequency component. This overestimation led the algorithm to over-compensate in the low-frequency region so that high-frequency components appeared relatively strong. The MTFs with between 11- and 15-pixel SEs showed little variation. Compared to spatial or frequency filtering that eliminated baseline effects in the edge spread function, our algorithm performed better at precisely locating the edge position and the averaged LSF was narrower.

댐 유입량 자료를 이용한 갈수빈도해석에 대한 연구 (A Study on Low-flow Frequency Analysis Using Dam Inflow)

  • 정영훈;남우성;신홍준;허준행
    • 대한토목학회논문집
    • /
    • 제32권6B호
    • /
    • pp.363-371
    • /
    • 2012
  • 본 연구에서는 댐의 상시보장유량 설정에 기준이 되는 갈수량을 산정하기 위하여 화천댐과 춘천댐의 유입량 자료를 구축한 후 적합도 검정을 실시하여 적정확률분포형을 선정하였다. 또한 선정된 적정확률분포형에 대하여 재현기간에 따른 월별 유입량 계열로 산정한 갈수빈도해석 방법(case 1)과 월단위 누가유입량 계열의 차로 산정한 갈수빈도해석 방법(case 2)을 수행하였다. 본 연구를 통해 한강유역의 상류댐인 화천댐과 춘천댐의 통계적 특성을 반영한 월별 재현기간에 따른 유입량은 홍수기에 제한수위를 설정하는 것과 같은 형식으로 댐의 상시보장유량을 보장하는 저수위를 설정하거나 이수용량을 결정하는데 활용될 수 있을 것으로 판단된다.

Low Frequency Perception of Rhythm and Intonation Speech Patterns by Normal Hearing Adults

  • Kim, Young-Sun;Asp, Carl-W.
    • 음성과학
    • /
    • 제9권1호
    • /
    • pp.7-16
    • /
    • 2002
  • This study tested normal hearing adults' auditory perception of rhythm and intonation patterns, with low-frequency speech energy. The results showed that the narrow-band low-frequency zones of 125, 250, or 500 Hz provided the same important rhythm and intonation cues as did the wide-band condition. This suggested that an auditory training strategy that uses low-frequency filters would be effective for structuring or re-structuring the perception of rhythm and intonation patterns. These filters force the client to focus on these patterns, because the speech intelligibility is drastically reduced. This strategy can be used with both normal-hearing and hearing impaired children and adults with poor listening skills, and possibly poor speech intelligibility.

  • PDF

조합형 소음기를 이용한 박용 디젤 엔진 배기 소음 제어 (Exhaust Noise Control of Marine Diesel Engine Using Hybrid Silencer)

  • 이태경;주원호;배종국
    • 한국소음진동공학회논문집
    • /
    • 제19권7호
    • /
    • pp.679-684
    • /
    • 2009
  • Low frequency exhaust noise of marine diesel engine is one of the most important noise sources in vessels. However, conventional absorptive silencers are ineffective to control exhaust noise because of low absorption in the low frequency range. In the paper, exhaust noise control of marine diesel engine was studied by using the hybrid silencer, which was composed of virtually divided array of concentric hole-cavity resonators and conventional absorptive silencer. A series of tests including field tests were performed to investigate the acoustic performance of the hybrid silencer. Consequently, its high performance of 5${\sim}$10 dB noise reduction in the low frequency range was confirmed and it is expected to be very helpful in reducing the exhaust noise of marine diesel engine.

희석된 수소/공기 확산화염의 비정상 음향파 응답특성 해석 (Unsteady Analysis of Acoustic-Pressure Responses of $N_{2}$ Diluted $H_{2}$ and Air Diffusion Flames)

  • 손채훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.320-325
    • /
    • 2003
  • Acoustic-Pressure Response of diluted hydrogen-air diffusion flames is investigated numerically by adopting a fully unsteady analysis of flame structures. In the low-pressure regime, the amplification index remains low and constant at low frequencies. As acoustic frequency increases, finite-rate chemistry is enhanced through a nonlinear accumulation of heat release rate, leading to a high amplification index. Finally, the flame responses decrease at high frequency due to the response lag of the transport zone. For a medium-pressure operation and low-frequency excitation, the amplification index is low and constant. It then decreases at moderate frequencies. As frequency increases further, the amplification index increases appreciably due to an intense accumulation effect.

  • PDF