Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

Distribution of Benthic Macrofauna in subtidal area and on sand flat of Sindu-ri coast, Korea (신두리 해안의 조하대와 모래 갯벌에 서식하는 대형저서동물의 분포)

  • Koo, Bon Joo;Shin, Sang Ho;Woo, Han Jun
    • Journal of Wetlands Research
    • /
    • v.7 no.2
    • /
    • pp.69-88
    • /
    • 2005
  • Distribution of benthic macrofauna was surveyed in the subtidal area and on the sand flat of Sindu-ri coast during July 2002. A total of 134 species, 3,511 individuals and 388g biomass of macrobenthos were sampled inclusively from the study sites. 109 species with a mean density of $1,298ind./m^2$ and biomass of $69.4g/m^2$ were collected from 10 stations established in the subtidal area. Polychaetes were represented as a dominant faunal group of the subtidal area in both species richness and density with values of 54 species and $813ind./m^2$. Cluster analysis based on the faunal composition showed that the subtidal area could be divided into four stational groups according to sedimentary characteristics: Cirrophorus armatus - Lumbrineris longifolia association on the mud sediment with pebbles near aqua-farms; Aonides oxycephala association on the rocky bed; Scoloplos armiger - Grandifoxus cuspis association on the sand-dominated sediment along the lowest low water; a association with higher evenness on the sand-dominated sediment in the depth. Although having characteristics of high value in species richness, density and species diversity, the macrobenthic association around the farming area was dominated by the opportunistic species such as Lumbrineris longifolia and Tharyx sp. Natural community represented by S. armiger and G. cuspis was developed in most sand-dominated areas. 50 species were sampled with a mean density of $2,443ind./m^2$ and biomass of $381.3g/m^2$ from eight+ stations along two transects on Sindu-ri sand flat. Mollusks were represented as a dominant faunal group of the sand flat in species richness, density and biomass with values of 20 species, $1,345ind./m^2$ and $350.4g/m^2$, respectively. Umbonium thomasi, Veneridae sp., Mandibulophoxus mai, Armandia lanceolata, Eohaustorius spinigerus, Urothoe convexa were dominant species and these species accounted for over 83% of total individuals. There were three distinct zones of macrobenthos on Sindu-ri sand flat according to the extent of exposure time. The upper zone was dominated by Scopimera globosa, the middle zone was characterized by M. mai, and the lower zone was dominated by E. spinigerus. Sindu-ri coastal area was considered as a healthy habitat for macrobenthos, except for around the farming area. It was considered that Sindu-ri coastal area including the sand flat connected to the sand dune of natural monument was a valuable habitat as a protected site in having no pollution source and no artificial structure.

  • PDF

Evaluation of Surface Covering Methods for Reducing Soil Loss of Highland Slope in Soybean Cultivation (고랭지 경사 밭 콩 재배지에서 토양유실경감을 위한 피복방법 평가)

  • Lee, Jeong-Tae;Lee, Gye-Jun;Ryu, Jong-Soo;Kim, Jeom-Soon;Han, Kyung-Hwa;Zhang, Yong-Seon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.5
    • /
    • pp.725-732
    • /
    • 2012
  • There is relatively high vulnerability of soil erosion in slope highland agriculture due to a reclamation of mountain as well as low surface covering during early summer with high rainfall intensity. Especially, in soybean cultivation, soil disturbance by conventional tillage and exposure of topsoil at the early stage of soybean have intensified soil loss. The aim of this study was to evaluate various surface covering methods for reducing soil loss in highland soybean cultivation. The experiment was conducted in 17% sloped lysimeter ($2.5m{\times}13.4m$) with 8 treatments. Amount of runoff water and eroded soil, and soybean growth were investigated. Surface covering through sod culture and plant residue showed 3.4~45.0 runoff water amount with $177{\sim}2,375m^3\;ha^{-1}$ compared with control ($5,274m^3\;ha^{-1}$). And the amount of eroded soil was also reduced by 95% in surface covering treatment with $0.02{\sim}1.94Mg\;ha^{-1}$ than control with $40.72Mg\;ha^{-1}$. Yields of soybean pod showed $0.3Mg\;ha^{-1}$ in rye sod culture, $1.3Mg\;ha^{-1}$ in Ligularia fischeri var. spiciformis Nakai, $0.7Mg\;ha^{-1}$ in Aster koraiensis Nakai, $0.2Mg\;ha^{-1}$ in red clover and $2.0Mg\;ha^{-1}$ in non-covering, on the other hand, covering with cut rye showed $3.8Mg\;ha^{-1}$. Conclusively, covering the soil surface with cut rye were beneficial for reduction of soil loss without decreasing soybean yield in highland sloped fields.

Nationwise Survey of the X-ray Beam Collimator Utilization in General Diagnostic Radiograph (진단방사선 일반촬영에서의 X-ray Beam Collimator 사용 전국 실태조사)

  • Kim, Jee Hye;Sung, Dong-Wook;Kim, Jeong Wook;Shin, Jin Ho;Lee, Soon Keun;Jung, Kyung Il;Uhm, Jong Kwan;Lee, Ki Nam;Seong, Ho Jin;Kim, Youn Hyun;Kim, Hyeog Ju
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.119-126
    • /
    • 2013
  • Due to the introduction of CR and DR, it has been neglected the use of the X-ray beam collimator and field size. This study examines nationwide survey of the proper use of collimator and field size by area in a specific field of plain radiography and the current status. Authors emphasized the need for the field size criteria, and propose a standard reference field size in each specific radiologic examination. Total 333 medical institutions (included in Seoul, Gyeonggi-do, Jeolla, Chungcheong, Gangwon-do, Busan area), were investigated in relation to the status of the X-ray beam collimation field size, type specific inspection areas, medical facilities, and image analyses by type to figure out whether they use the adjustment of image field to the specific examination. To assess the awareness and the impact of radiation exposure to the collimation adjustable, 168 radiographers who was working in 10 general hospitals, 10 hospitals, and 10 clinics, were surveyed how they haver adjusted the actual field size. We examine that 61.3% of medical institutions used the "Proper collimation" and only 49.9% of them employed proper one in lumbar spine densely crowded by major organs. 69% among general hospitals, and 65% among hospitals using DR system were using proper collimation. Radiographers recognized that proper adjustment of collimation could reduce the harmful radiation dose on patients. In the survey, 97.6% of respondents were aware of this fact, but only 83.3% of respondents did the adjustment of the size of the collimation field. The using of proper collimation field was low in the nationwide survey, so the effort to reduce the radiation dose on the patients is urgently needed. A unified standard for the field accompanied by thorough education should be needed.

The Evaluation of External Radiation Exposure dose rate for Radium-223 Dichloride (Radium-223 Dichloride의 외부 방사선량의 평가)

  • Cho, Seong Wook;Yoon, Seok Hwan;Seung, Jong Min;Kim, Tae Yub;Im, Jeong Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.28-31
    • /
    • 2016
  • Purpose $^{223}Ra-Dichloride$ is used for the medicine of castration-resistant prostate cancer (CRPC) and which emits ${\alpha}-ray$ of 28 Mev that is used for therapy. However $^{223}Ra-Dichloride$ emits ${\beta}-ray$ of 3.6% and ${\gamma}-ray$ of 1.1%(80,156,270 keV) aside from ${\alpha}-ray$ in decay. Therefore we would like to evaluate external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$. Materials and Methods We calculated external radiation expose dose rate using ${\gamma}-constant$ of $^{223}Ra-Dichloride$, $^{99m}Tc$ based on Health physics(2012). $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq were applied. external radiation expose dose rate 15 times from 1m by survey meter. Results ${\gamma}-contant$ of $^{223}Ra$, $^{99m}Tc-MDP$ from 1m distance based on Health physics(2012) is 0.0469, 0.0215. calculated value of external radiation expose dose rate was $16{\mu}Sy$, $34{\mu}Sy$ which activity is $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq from 1 m and measured mean value of 1 m was $0.7{\mu}Sy/h$, $18{\mu}Sy/h$. Conclusion ${\gamma}-constant$ of $^{223}Ra$ is higher than $^{99m}Tc$ based on Health physics(2012). however calculated maximum external radiation expose dose rate of $^{223}Ra-Dichloride$ is lower than $^{99m}Tc$ due to actually used quantity of activity of $^{223}Ra-Dichloride$ is small. measured value of $^{223}Ra-Dichloride$ is also lower than $^{99m}Tc-MDP$. Therefore external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$ is very low.

  • PDF

The current status and control measures of BSE in the worldwide (국내, 외 광우병의 발생 현황과 대응 방안)

  • Yoo, Han-Sang
    • 한국환경농학회:학술대회논문집
    • /
    • 2009.07a
    • /
    • pp.273-282
    • /
    • 2009
  • The transmissible spongiform encephalopathies (TSEs) disease group are fatal neurodegenerative disorders affecting a wide range of hosts. The group includes kuru and Creutzfeldt-Jakob disease (CJD) in humans, scrapie in sheep and goats and Bovine spongiform encephalopathy (BSE) in cattle. The exact nature of the infectious agent involved in the transmission of these diseases remains controversial. However, a central event in their pathogenesis is the accumulation in infected tissues of an abnormal form of a host-encoded protein, the prion protein (PrP). Whereas the normal cellular protein is fully sensitive to protease ($PrP^{sen}$), the disease-associated prion protein ($PrP^d$) is only partly degraded ($PrP^{res}$), its amino-terminal end being removed. BSE was first reported in the mid-80s in the UK. Ten years later, a new form of human prion disease, variant CJD (vCJD) developed in the wake of the BSE epidemic, and there is now strong scientific evidence that vCJD was initiated by the exposure of humans to BSE-infected tissues, thus indicating a zoonotic disease. However, the ban on the feeding of animal-derived proteins to ruminants, and the apparent lack of vertical transmission of BSE, have led to a decline in the incidence of the disease within cattle herd and therefore, an assumed decreased risk for human contacting vCJD. The origin of the original case(s) of BSE still remains an enigma even though three hypotheses have been raised. Hypotheses are i) sheep- or goat-derived scrapie-infected tissues included in meat and bone meal fed to cattle, ii) a previously undetected sporadic or genetic bovine TSE contaminating cattle feed or iii) originating from a human TSE through animal feed contaminated with human remains. A host cellular membrane protein ($PrP^C$), which is abundant in central nervous system tissue, appear to be conformationally altered in the diseased host into a prion protein ($PrP^{Sc}$). This $PrP^{Sc}$ is detergent insoluble and partially protease-resistant ($PrP^{res}$). The term $PrP^{res}$ is normally used to describe the protein detected after protease treatment, in techniques such as Western immunoblotting, and enzyme-linked immunosorbant assay using fresh/frozen tissue. Immunohistochemistry may performed with formalin-fixed tissues. Also, clinical signs of the BSE are one of the major diagnostic indicators. Recently, atypical forms (known as H- and L-type) of BSE have appeared in several European countries, Japan, Canada and the United States. An unusual case was also reported in a miniature zebu. The atypical BSE fall into two groups based on the relative molecular mass (Mm) of the unglycosylated $PrP^{res}$ band relative to that of classical BSE, one of the higher Mm (H-type) and the other lower (L-type). Both types have been detected worldwide as rare cases in older animals, at a low prevalence consistent with the possibility of sporadic forms of prion diseases in cattle. This raises the unwelcome possibility that vCJD could increase in the human population. Now, active surveillance program against BSE is going on in Korea. In regional veterinary service lab, ELISA is applied to screen the BSE in slaughter and confirmatory tests by Western immunoblotting and immunohistochemisty are carried out if there are positive or suspect in the screening test. Also, the ruminant feed ban is rigorously enforced. Removal of specified risk materials such as brain and spinal cord from cattle is mandatory process at slaughter to prevent the infected material from entering the human food chain.

  • PDF

Time Course Variation of Liver 25-Bydroxyvitamin $D_3$ Content in Broiler Chicks Exposed to UVB Light with Different Dobe (상이한 선양의 자외선을 조사한 브로일러 병아리에 있어서 간장 25-Hydroxyvitamin $D_3$회량의 계치적 변화)

  • 장윤환;강훈석;여영수;김강수;조인호;배은경
    • Korean Journal of Poultry Science
    • /
    • v.19 no.4
    • /
    • pp.217-225
    • /
    • 1992
  • This research was carried out to determine the 25-Hydroxyvitamin $D_3$[25(OH)$D_3$] content in liver of broiler Hubbard chicks fed vitamin VD-deficient diet for 31 days in a subdued light room and exposed to UVB light (maximum intensity at 297nm) with dose of 0.204 or 0.408 mJ/$\textrm{cm}^2$(30 or 60 min irradiation) . The lipid in liver collected at 0~138 hr after irradiation was extracted by chloroform-methanol(2:1, v /v) and 25(OH)$D_3$ fraction was separated by Sep-Pak silica cartridge. The 25(OH)$D_3$ concentration was measured by normal phase HPLC. The negative control chicks Presented 25(OH)D$_3$17.5 ng/g liver. When 0.204mJ/$\textrm{cm}^2$ was treated to whole body of chicks, the 25(OH)$D_3$ level was increased to 37.8 ng/g at 12 hr after irradiation, the peak concentration, 40.5 ng /g was appeared at the time of 86 hr, and decreasing trend was shown thereafter until 138 hr, the final time in this study. When 0.408 mJ/$\textrm{cm}^2$ was applied, the 25(OH)$D_3$ content was 36.7 ng /g liver at 12 hr, 61.4 ng/g(maximum value ) was appeared at 42 hr, and 39.5 ng /g at 138 hr. The increased absolute amounts in liver 25(OH)$D_3$ were 23 and 43.9 ng/g as chicks were exposed to UVB light with dose of 0.204 and 0.408mJ/$\textrm{cm}^2$, respectively. Consequently, it was found that when double dose of UVB light was irradiated to the chicks, their liver samples produced nearly double 25(OH)$D_3$ at 42 hr after exposure, and the peak value was presented earlier by 24 hr than that in the low dose treatment.

  • PDF

Comparison of Passive Diffusional Organic Vapor Samplers with Charcoal Tubes for the Measurement of Mixed Organic Solvents (확산형 포집기와 활성탄관을 이용한 공기중 혼합 유기용제 측정에 관한 연구)

  • Ahn, Kyu-Dong;Yeon, You-Yong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.127-136
    • /
    • 1994
  • Diffusional sampling devices offer many advantages for measuring concentration levels of industrial contaminants than the conventional pump and charcoal tubes because they are lightweight, require no power, pump or tubing. This study designed to evaluate and compare the sampling performance of passive sampler to charcoal tube from mixed organic solvent workplace with 181 organic solvent using workers working in different concentration of organic solvents. All study workers kept both devices in their breathing zone simultaneuosly in the workplaces, and the sampling analytical results were compared with those of charcoal tube. The results obtained are as follows: 1. The concentrations of toluene and xylene measured by passive sampler were slightly higher than those of charcoal tube, but there were no significant statistical differences between two methods. 2. The concentrations of MEK and cyclo-hexanone measured by passive sampler in low exposure workplace (below 0.20 of MEK TLV levels and 0.1 of cyclo-hexanone TLV levels) were about 2 times higher than that of charcoal tube sampling. While, absorption efficiency of passive sampler was reduced according to increasing concentration measurements of MEK and cyclo-hexanone in air. 3. The ratios of concentrations of toluene, xylene, MEK and cyc1o-hexanone measured by passive sampler over those measured by charcoal tube were 1.11, 1.07, 1.63 and 3.65 respectively. 4. The percentages of concentration of passive samplers within 0.75 and 1.25 of charcoal tube value as a reference value of 1.0 were 57% in toluene, 74% in xylene, 34% in MEK and 32% in cyclo-hexanone respectively. 5. The correlation coefficients of toluene, xylene, MEK and cyclo-hexanone between passive sampler and charcoal tube sampler were 0.963, 0.957, 0.943 and 0.562 with statistical significance.

  • PDF

A Study on the Effective Half-life after the High Dose Radioactive Iodine (131I) Therapy for Thyroid Cancer Patients (갑상선암 환자에서 고용량 방사성요오드 치료 후 유효반감기에 대한 연구)

  • Kim, Seongcheol;Gwon, DaYeong;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.597-603
    • /
    • 2017
  • High-dose $^{131}I$ therapy has been generally carried out to remove remaining thyroid tissue or to cure metastasize lesion of patients who received full thyroidectomy due to differentiated thyroid cancers. In case high-dose $^{131}I$ therapy is carried out for a patient, the patient should be hospitalized being isolated for a certain period in order to restrict the amount of exposure to radiation of people at large from the patient within the limit of a level of radiation. Effective half-life is an important value to calculate how family members are exposed to radiation from a patient or to decide the period of isolation of the patient from the family members. Therefore, in this study we calculated the effective decay constant, effective half-life and period of isolation of high-dose $^{131}I$ therapy patient using NM670 SPECT/CT. As a result of carrying out this study, the effective half-life of high-dose $^{131}I$ therapy patients was derived and the time to reach the discharge level of 1.2 GBq was confirmed. When they were compared with each other in each of curative doses, the effective half-life did not have significant difference, but the time when the level of radiation remaining in the interior of the body to reach the criteria of isolation and discharge showed significant difference and it could be confirmed that the higher the curative dose the longer the period of isolation becomes. When the effective half-lives in each type of preparation were compared with each other, they did not show significant difference. However, When the times to reach the level of radiation that is the criteria of isolation and discharge in each type of preparations, they showed significant difference. The cause of the shortening of the isolation period for rhTSH patients group is decided to be low curative dose. Accordingly, if the current national health insurance (the insurance is applied to using of rhTSH in 3.7 GBq or lower) is maintained, while discerning them in each of types of preparation, we would be able to discharge patients at the time earlier than the current period of isolation (2 nights and 3 days).