• 제목/요약/키워드: Low energy apartment houses

검색결과 10건 처리시간 0.019초

저에너지 공동주택 구현을 위한 요소기술 선정 기법에 관한 연구 (Energy Saving Design Method with the Consideration of the Initial Cost for Apartment Houses)

  • 손원득;이종일;윤대원;이건호;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.24-31
    • /
    • 2014
  • So many energy saving strategies to realize the low energy house are proposed in these days. Even if the energy saving performances are similar between the strategies, the costs are in abroad ranges. Therefore, the application of the energy saving strategies should be based upon two considerations; one is energy saving performance and the other is the cost. In this study, the decision making method for application of the passive design technologies in the design stage of the low energy apartment house are suggested. By utilizing the result of this study, practitioners can make an effective design alternatives which solve the conflicted values; energy saving and cost.

공동주택에서 에너지 파일을 이용한 지열히트펌프 시스템의 성능 분석 (Performance Evaluation of Ground Source Heat Pump System Utilizing Energy Pile in Apartment)

  • 이진욱;김태연;이승복
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.41-46
    • /
    • 2012
  • In Korea, Apartment houses recently occupy over 80% of all buildings. Ground source system has to be designed to consider feature of apartment house. Most apartment houses use PHC pile to get a bearing power of the soil. Therefore, the purpose of this study is to evaluate performance of ground source heat pump system utilizing energy pile under apartment. Object of experiment is low-energy experiment apartment in Song-do and Energy Pile are applied to 80%, 100% energy reduction model for heat-source. First, performance evaluation of Energy Pile geothermal system was done during summer season. As a result, The COP(coefficient of performance) about geothermal heatpump was approximately 5-6 while cooling. In winter season, Long experiment was performed because it was very important to evaluate ground condition for long time. During heating experiment, Indoor room set temperature was $20^{\circ}C$ and kept constant by heating. Coefficient of performance for heat pump and overall system was calculated. It was 3.5-4.5 for COP and 2.5-3.7 for system COP.

우리나라 아파트 단지의 친환경계획 경향에 관한 연구 - 2000년대 수도권 지역 공공부문 아파트 단지를 중심으로 - (A Study on the Eco-friendly Planning Methods in Korean Apartment Houses - Focusing on the public sector housing in the Metropolitan Area in the 2000s -)

  • 김용국;서경욱
    • 한국실내디자인학회논문집
    • /
    • 제22권4호
    • /
    • pp.141-148
    • /
    • 2013
  • This study aims to investigate the eco-friendly planning methods for a sustainable apartment houses in the Metropolitan area of Seoul. Eco-friendly plans that considers the environmental issues were attempted from the beginning of 2000s, and since then, many apartment houses in Korea were built using this concept. They were, however, generally focusing on the physical and spatial aspects of the site plan. After the Seoul C40 weather summit conference in 2009, the low carbon green housing standard has been emphasized and thus the chemical concept was added to the existing physical planning methods. Under such a background, this study intends to investigate the eco-friendly plans for the apartment houses in the 2000s. This includes an ecological network plan, an ecological base plan, a building greening plan, a water treatment plan, and an energy saving plan. Based on the analysis and synthesis of these planning methods in the early 21st century, it would be possible to set up a proper future plan to enhance the sustainable built environment in the housing industry in the coming years.

선행연구 분석을 통한 녹색건축 인증제의 개선방향에 관한 연구 - 공동주택 부문을 중심으로 (A Study on the Improvement of G-SEED through Analysis of the Previous Studies - Based on Apartment Houses)

  • 윤요선;류수훈
    • KIEAE Journal
    • /
    • 제13권5호
    • /
    • pp.31-42
    • /
    • 2013
  • Green Standard for Energy and Environmental Design (G-SEED) is evaluates the eco-friendliness of the building as an abjective means. Study in green building is made actively, and is being developed through constant revision. However, study results of green building have not been fully reflected in the standard. Therefore, this study analyzes the previous studies about G-SEED and checks the reflection of requirements. This study will be a reference of future revision of G-SEED. Score of items are divided into low and high score items. These items should be reflected appropriately in the standard through the score adjustment. Some requirements proposed in previous studies was reflected, while substantial requirements was not reflected. Proposed improvement requirements are classed as to establish specific standards, strengthen standards, propose a new evaluation method to existing items, and add new items.

중앙난방방식을 지역난방.소형열병합난방방식으로 전환시의 경제성 비교 분석 (Analysis for the Economic efficiency of District Heating and Gas Engine Co-generation System comparing with Central Heating System)

  • 김규생;이상혁;홍경표;원영재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.459-465
    • /
    • 2007
  • This study was conducted to calculate the LCC of a apartment complex with a type of heating system, district heating and cogeneration system. For the purpose of analyzing LCC according to size of apartment complex, 500, 1,500 and 4,000 houses of model apartment selected. This research performs design of heating system and the life cycle cost analysis including an initial cost, energy cost, maintenance and operation cost, replacement cost and renovation cost during the project period(15years). According to the calculated results, 1) Initial cost of cogeneration system with 500, 1500 and 4000 houses is higher than district heating system each of 20%, 13%, 12%. 2) In case of cogeneration system, the payback period by electric generation is 5.21, 4.92 and 4.47 years and saving cost was calculated 29 billion won, 94 billion won and 262 billion won after payback period. 3) Cogeneration system LCC was 1.12, 1.07 and 1.06 times larger than district system with the size of apartment complex. According to the case of this study district heating system is more efficient than cogeneration system in terms of the reduction of LCC. 4) Gas Engine Co-generation System is more efficient than other systems because it can collect progressive part from electric charge progressive stage system. However, the efficiency is decreasing because of raising of fuel bills(LNG) and lowering of power rate for house use. Especially the engine is foreign-made so the cost of maintenance and repair is high and the technical expert is short. 5) District heating is also affected by fuel bills so we should improve energy efficiency through recovering of waste heat(incineration heat, etc.). Also, we should supply district cooling on the pattern of heat using of let the temperature high in winter and low in summer.

  • PDF

건물일체형 지열히트펌프시스템의 난방 성능 분석 (Heating Performance Analysis of Building Integrated Geothermal System)

  • 김상진;이진욱;김태연;이승복
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.206-210
    • /
    • 2012
  • Ground source heat pump is a central heating and cooling system that pumps heat to or from the ground. Building Integrated Geothermal system used in this experiment is one of the Ground Source Heat Pump Systems which utilize energy pile. The purpose of this study is to evaluate heating performance of the system. The building is a low-energy experiment apartment in Yonsei University Songdo Campus and the subject is one of the energy reduced houses in this apartment. In the experiment, indoor temperature, outdoor temperature and the inlet and outlet temperature of ground heat exchanger and subject model, were measured. Then the heat pump's Coefficient of performance(COP) of the heat pump was calculated. As a result, the COP of heat pump is 4-5. Although the depth of the ground heat exchanger in this experiment is shallower than usual heat exchanger, the result of heating performance of this system was good as well.

  • PDF

에너지절약형 이중외피 창호의 기본채광 성능 (Daylighting Performance of a New-Developed Energy Efficient Double-Skin Window System)

  • 박종명;김재훈;최진우;임홍수;김곤
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.117-122
    • /
    • 2008
  • The apartment will be much more convenient than the other one in the application of green technologies, providing the merits by mass production. For example, pre-manufactured building materials can be effectively adapted to the formation of buildings. Recently, the form of double-enveloped window system has been developed for the purposed of minimizing energy loss occurred around windows. On the other hand, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. A various types of glass can be applied to the window system and it plays a critical role in the determination of inner visual environment. For the purpose of verifying the potential of its daylighting, a mock-up model has been constructed and tested. The refurbished version of conventional window shows its illuminated characteristics. Clear and Low-e glass have been adapted for window area and daylighting ratio has been compared in both test cells.

  • PDF

공동주택 지역난방 수질기준 설정에 관한 연구 (A Development of the Guideline for the Heating Water Quality in Apartment Houses with District Heating System)

  • 김용기;이태원;우달식;오준;안창구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.493-498
    • /
    • 2008
  • Particles or deposit formed by corrosion of the pipe material bring about bad influences on the heating systems with inconvenience, energy loss and so on. In order to obtain the non-corrosive environments, the circulation hot water should properly be treated in several ways to satisfy one or more conditions of the followings: suitable pH-level, low hardness, low oxygen content, low conductivity, low level of chlorides and sulphur compounds and low level of solid particles. This experimental study was carried out to develope the new guidelines on the optimal water quality and directions for water quality management in heating systems. As results, it was recommended that the heating water be maintained pH-level not less than 8, hardness contents as $CaCO_3$ no more than 50 mg/L, turbidity no more than 10 NTU and T-Fe contents 1 mg/L below.

  • PDF

건물에너지 효율등급 제도를 이용한 시나리오별 목표 온실가스 저감방안에 관한 연구 (A Study on Finding Ways to Reduce the Emission of Target Greenhouse Gases for Various Scenarios Utilizing the Building Energy Efficiency Rating)

  • 방영현;강아람;박효순;서승직
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.89-94
    • /
    • 2012
  • The international community is paying close attention to the climatic changes caused by the meteorological anomalies. In response to such phenomena, after the adoption of the United Nations Framework Convention on Climate Change in 1992, efforts to actively respond to the meteorological changes are proliferating all over the world; even in the Republic of Korea, the issue to tackle the meteorological changes has emerged as a top-priority national agenda. In the year of 2008, after the declaration of the low-carbon, green-growth paradigm by the government, the UNFCCC COP15 has announced a 30% reduction target of the emission of the greenhouse gases by 2020 as compared to the "Business As Usual, BAU" and has also confirmed, as a commitment plan to achieve reduction in the emission of greenhouse gases, the reduction target of greenhouse gases for all sectors, industries and years. (26.9% for buildings) Since the construction of the new apartment houses in the year of 2001, the "Building Energy Efficiency Rating", has been applied to newly constructed building complexes, built in 2010; the accumulated emission reduction has been evaluated at around 450,000toe and the accumulated carbon dioxide emission reduction is at $826,000tCO_2$ And through the prediction of these values under various scenarios (New construction, new construction / expansion of existing uses, when transferred to 1stgrade), the effects on the degree of reduction of greenhouse gases by the increased certification of the Building Energy Efficiency Rating are an alyzed and it is our aim to express the importance of the certification system capable of carrying out a quantitative evaluation of the building energy in order to establish the strategy to reduce the emission of carbon dioxide.

에어커튼형 레인지후드의 슬롯 토출 각도 변화와 배기 효율 (Effect of Slot Discharge-Angle Change on Exhaust Efficiency of Range Hood System with Air Curtain)

  • 성순경
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.468-474
    • /
    • 2015
  • When oil is used for cooking in detached or apartment houses, large amounts of oil-mist, smoke, and particulate substances are generated and dispersed into the indoor-air environment. These pollutants diffuse into the surroundings and spread their odor while rising fast at a high temperature due to the heat energy from the gas range. Although the exhaust gas is discharged from the exhaust hood, which is installed on the top of a gas range to remove the diffuse pollutants, the exhaust conditions can vary greatly because they depend on the shape of the exhaust hood and the discharge rate. In this paper, the air that is required for the gas-exhaustion process is supplied by an air curtain that surrounds the kitchen hood, and the pollutant-capturing efficiency varies depending on the angle of the discharge grills; the pollutant-capturing efficiency was studied using a numerical-analysis method. The results indicate that the pollutant-capturing efficiency is not significantly changed by a change of the discharge-grill angle at a low air-discharge rate; however, at a high air-discharge rate, the efficiency value increases with an increase of the discharge-grill angle, whereby the best value occurs at 30 degrees and the efficiency decreases above this angle. Below 30 degrees, the effect of the discharge rate on the capturing efficiency is more than that of the discharge-grill angle.