• 제목/요약/키워드: Low cost sensor calibration

검색결과 38건 처리시간 0.028초

PSD센서를 이용한 모션캡쳐 시스템의 센서보정에 관한 연구 (A Study on the Sensor Calibration for Low Cost Motion Capture Sensor using PSD Sensor)

  • 김유건;최훈일;유영기;오춘석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.603-605
    • /
    • 2005
  • In this paper, we deal with a calibration method for low cost motion capture sensor using PSD (Position Sensitive Detection). The PSD sensor is employed to measure the direction of incident light from moving markers attached to motion body. To calibrate the PSD optical module, a conventional camera calibration algorithm introduced by Tsai. The 3-dimensional positions of the markers are measured by using stereo camera geometry. From the experimental results, the low cost motion capture sensor can be used in a real time system.

  • PDF

Calibration of Portable Particulate Mattere-Monitoring Device using Web Query and Machine Learning

  • Loh, Byoung Gook;Choi, Gi Heung
    • Safety and Health at Work
    • /
    • 제10권4호
    • /
    • pp.452-460
    • /
    • 2019
  • Background: Monitoring and control of PM2.5 are being recognized as key to address health issues attributed to PM2.5. Availability of low-cost PM2.5 sensors made it possible to introduce a number of portable PM2.5 monitors based on light scattering to the consumer market at an affordable price. Accuracy of light scatteringe-based PM2.5 monitors significantly depends on the method of calibration. Static calibration curve is used as the most popular calibration method for low-cost PM2.5 sensors particularly because of ease of application. Drawback in this approach is, however, the lack of accuracy. Methods: This study discussed the calibration of a low-cost PM2.5-monitoring device (PMD) to improve the accuracy and reliability for practical use. The proposed method is based on construction of the PM2.5 sensor network using Message Queuing Telemetry Transport (MQTT) protocol and web query of reference measurement data available at government-authorized PM monitoring station (GAMS) in the republic of Korea. Four machine learning (ML) algorithms such as support vector machine, k-nearest neighbors, random forest, and extreme gradient boosting were used as regression models to calibrate the PMD measurements of PM2.5. Performance of each ML algorithm was evaluated using stratified K-fold cross-validation, and a linear regression model was used as a reference. Results: Based on the performance of ML algorithms used, regression of the output of the PMD to PM2.5 concentrations data available from the GAMS through web query was effective. The extreme gradient boosting algorithm showed the best performance with a mean coefficient of determination (R2) of 0.78 and standard error of 5.0 ㎍/㎥, corresponding to 8% increase in R2 and 12% decrease in root mean square error in comparison with the linear regression model. Minimum 100 hours of calibration period was found required to calibrate the PMD to its full capacity. Calibration method proposed poses a limitation on the location of the PMD being in the vicinity of the GAMS. As the number of the PMD participating in the sensor network increases, however, calibrated PMDs can be used as reference devices to nearby PMDs that require calibration, forming a calibration chain through MQTT protocol. Conclusions: Calibration of a low-cost PMD, which is based on construction of PM2.5 sensor network using MQTT protocol and web query of reference measurement data available at a GAMS, significantly improves the accuracy and reliability of a PMD, thereby making practical use of the low-cost PMD possible.

병렬기구형 공작기졔의 기구학적 보정에 관한 연구 (Study on Kinematic Calibration of a Parallel-typed Machining Center Tool)

  • 이민기;김태성;박근우
    • 대한기계학회논문집A
    • /
    • 제26권11호
    • /
    • pp.2237-2244
    • /
    • 2002
  • This research develops a low-cost and high accuracy kinematic calibration method based on the following principles: 1) the platform locations are accurately measured by a constrained movement to inspect a calibration target; 2) the constrained movement is chosen to guarantee the parameter observability; 3) the mechanical fixture to constrain the movement and the sensor to check the constrained movement are implemented by low-cost and high-accuracy devices; 4) the calibration is easily done at an industrial environment. The kinematic parameters calibrated with respect to a single plane aren't influenced due to the misalignment of the plane. A parameter observability is successfully obtained even through one planar constraint, which guarantees that all kinematic parameters are estimated by minimizing the cost function.

PSD센서모듈 기반 단안 모션캡쳐 시스템 (PSD Sensor Module Based Monocular Motion Capture System)

  • 김유건;유영기;오춘석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.582-584
    • /
    • 2006
  • This paper describes a monocular PSD-based motion capture sensor to employ with commercial video game systems such as Microsoft's XBOX and Sony's Playstation II. The system compact, low-cost, and only requires a one-time calibration at the factory. The system includes a PSD(Position Sensitive Detector) and active infrared (IR) LED markers that are placed on the object to be tracked. The PSD sensor is placed in the focal plane of a wide-angle lens. The micro-controller calculates the 3D position of the markers using only the measured intensity and 2D position on the PSD. A series of experiments were performed to evaluate the performance of our prototype system. From the experimental results we see that the proposed system's compact size, low-cost, ease of installation, and high frame rates are suitable for high speed motion tracking in games.

  • PDF

Hybrid Sensor Calibration Scheme for Mobile Crowdsensing-Based City-Scale Environmental Measurements

  • Son, Seung-Chul;Lee, Byung-Tak;Ko, Seok Kap;Kang, Kyungran
    • ETRI Journal
    • /
    • 제38권3호
    • /
    • pp.551-559
    • /
    • 2016
  • In this paper, we propose a hybrid sensor calibration scheme for mobile crowdsensing applications. As the number of newly produced mobile devices containing embedded sensors continues to rise, the potential to use mobile devices as a sensor data source increases. However, because mobile device sensors are generally of a lower performance and cost than dedicated sensors, sensor calibration is crucial. To enable more accurate measurements of natural phenomena through the use of mobile device sensors, we propose a hybrid sensor calibration scheme for such sensors; the scheme makes use of mobile device sensors and existing sensing infrastructure, such as weather stations, to obtain dense data. Simulation results show that the proposed scheme supports low mean square errors. As a practical application of our proposed scheme, we built a temperature map of a city using six mobile phone sensors and six reference sensors. Thanks to the mobility of the sensors and the proposed scheme, our map presents more detailed information than infrastructure-based measurements.

Low-Cost IoT Sensors for Flow Measurement in Open Channels: A Comparative Study of Laboratory and Field Performance

  • Khatatbeh, Arwa;Kim, Young-Oh
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.172-172
    • /
    • 2023
  • The use of low-cost IoT sensors for flow measurement in open channels has gained significant attention due to their potential to provide continuous and real-time data at a low cost. However, the accuracy and reliability of these sensors in real-world scenarios are not well understood. This study aims to compare the performance of low-cost IoT sensors in the laboratory and real-world conditions to evaluate their accuracy and reliability. Firstly, a low-cost IoT sensor was integrated with an IoT platform to acquire real-time flow rate data. The IoT sensors were calibrated in the laboratory environment to optimize their accuracy, including different types of low-cost IoT sensors (HC-SR04 ultrasonic sensor & YF-S201 sensor) using an open channel prototype. After calibration, the IoT sensors were then applied to a real-world case study in the Dorim-cheon stream, where they were compared to traditional flow measurement methods to evaluate their accuracy.The results showed that the low-cost IoT sensors provided accurate and reliable flow rate data under laboratory conditions, with an error range of less than 5%. However, when applied to the real-world case study, the accuracy of the IoT sensors decreased, which could be attributed to several factors such as the effects of water turbulence, sensor drift, and environmental factors. Overall, this study highlights the potential of low-cost IoT sensors for flow measurement in open channels and provides insights into their limitations and challenges in real-world scenarios.

  • PDF

The Development of a Wearable Prototype to Measure Clothing Pressure through Sensor Calibration Procedure

  • Jin, Heejae;Lee, Hyojeong
    • 한국의류학회지
    • /
    • 제46권5호
    • /
    • pp.827-835
    • /
    • 2022
  • Clothing pressure is considered the essential factor affecting the comfort of clothing, so it is crucial that it is measured precisely. The purpose of this study is to construct a prototype using the Adafruit Flora as the Arduino system, which can be used as a wearable framework for easy, low-cost, and precise clothing pressure measurement. The study also aims to determine how best to conduct the procedure of sensor calibration. To optimize the accuracy of the sensors, the calibration procedure was implemented using mathematical methods that combined polynomial and exponential regression in a hybrid approach. The prototype can easily measure clothing pressure even during active movements, as seen in the detection of stable signals. In addition, since the system was specifically proposed as a wearable patch that can be easily attached and removed as necessary, it can also be used to standardize the value of clothing pressure in each movement.

태양시선벡터를 이용한 저가 관성항법시스템의 보정 (Calibration of Low-cost Inertia Navigation System with Sun Line of Sight Vector)

  • 장세아;최기영
    • 제어로봇시스템학회논문지
    • /
    • 제14권8호
    • /
    • pp.774-778
    • /
    • 2008
  • The inaccuracy of inertial sensors used in low cost IMU's limits the usage to ARS, at best. Sensor fusion technologies are widely used to overcome this problem. GPS is the most popular secondary sensor, but GPS alone cannot fully compensate the IMU errors in the initial alignment process and rectilinear flights. This paper presents a new concept of aiding the low cost IMU with the sun line of sight vector. The simulation and experimental results in this paper proves that aiding of INS/GPS with the sun line of sight vector increases the observability and improves accuracy remarkably.

PSD 센서를 이용한 모션캡쳐센서의 정밀도 향상을 위한 보정에 관한 연구 (A Study on the Sensor Calibration of Motion Capture System using PSD Sensor to Improve the Accuracy)

  • 최훈일;조용준;유영기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.583-585
    • /
    • 2004
  • In this paper we will deal with a calibration method for low cost motion capture system using psd(position sensitive detection) optical sensor. To measure the incident direction of the light from LED emitted marker, the PSD is used the output current ratio on the electrode of PSD is proportional with the incident position of the light focused by lens. In order to defect the direction of the light, the current output is converted into digital voltage value by opamp circuits peak detector and AD converter with the digital value the incident position is measured. Unfortunately, due to the non-linearly problem of the circuit poor position accuracy is shown. To overcome such problems, we compensated the non-linearly by using least-square fitting method. After compensated the non-linearly in the circuit, the system showed more enhanced position accuracy.

  • PDF

타원체를 이용한 3축 센서의 실시간 보정 알고리듬 개발 (Development of the Calibration Algorithm of 3 Axis Vector Sensor Using Ellipsoid)

  • 황정문;김정한
    • 한국정밀공학회지
    • /
    • 제32권7호
    • /
    • pp.643-651
    • /
    • 2015
  • Multi-axis magnetic and accelerometer sensor are widely used in consumer product such as smart phones. The vector output of multi-axis sensors have errors on each axis such as offset error, scale error, non-orthogonality. These errors cause many problems on the performance of the applications. In this paper, we designed the effective inline compensation algorithm for calibrating of 3 axis sensors using ellipsoid for mass production of multi-axis sensors. The outputs with those kinds of errors can be modeled by ellipsoid, and the proposed algorithm makes sequential mappings of the virtual ellipsoid to perfect sphere which is calibrated function of the sensor on three-dimensional space. The proposed calibrating process composed of four main stages and is very straightforward and effective. In addition, another imperfection of the sensor such as the drift from temperature can be easily inserted in each mapping stage. Numerical simulation and experimental results shows great performance of the proposed compensation algorithm.