Loss Analysis of Three Phase Induction Motor Connected to Single Phase Source (단상전원에 접속된 3상 유도전동기의 손실분석)

  • Kim, Do-Jin;Jwa, Chong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.121-126
    • /
    • 2008
  • This paper analyzes the losses of a Steinmetz connection three-phase induction motor which is supplied by a single-phase source. The T-type equivalent circuit which is taken no-load losses into account is used to determine phase converter capacitive reactances at starting and rated speed by using the condition of the minimum voltage unbalance. The starting and the operating capacitor are replaced at the slip of the same voltage unbalance factor points which are depicted using two capacitive reactances. The operation characteristics are investigated by comparing with those of three-phase balanced operation to find the feasibility of single-phase operation. To analyze the losses of this motor, the output power decrease factor(OPDF), the loss ratio(LR), the no load loss ratio(NLLR), the copper loss ratio(CLR), the stator copper loss ratio(SCLR), and the rotor copper loss ratio(RCLR) are defined and simulated in the whole slip range. The simulated results show that OPDF is maintained almost uniformly, LR is low at low speed and high at high speed, CLR is higher !ban NLLR, but CLR varies concavely and NLLR varies convexly at high speed, SCLR is low at low speed and high at high speed, but SCLR varies convexly at high speed, and RCLR is nearly opposite to SCLR.

Contractible Beat Pipe for Conduction Cooled Superconducting Magnets

  • Kim, Seokho;Sangkwon Jeong;Jin, Hong-Beom;Kideok Sim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.76-80
    • /
    • 2003
  • A contractible heat pipe is designed and tested to improve cooling performance of conduction cooled superconducting magnet. When the heat pipe temperature drops below the triple point temperature, heat pipe working fluid freezes to create low pressure. From this moment the heat pipe does net work any more (OFF state) and it just works as a heat leak path when the temperature of the first stage is higher than that of the second stage. Considering small cooling capacity of the second stage around 4.2 K, the conduction loss is not negligible. Therefore, the contractible heat pipe, made of a metal bellows and copper tubes, was considered to eliminate the conduction loss. Nitrogen and argon are as working fluid of heat pipe. The copper block is cooled down with these heat pipe and the cooling performance for each heat pipe is compared. At off state, the bellows is contracted due to the low pressure of heat pipe and the evaporator section of the heat pipe is detached about 3 mm from the second stage cold head of the cryocooler. In this way, we tan eliminate the conduction loss through the heat pipe wall.

Comparison frequency responses of hairpin type superconducting and copper bandpass filters (헤어핀 초전도체 필터와 구리 필터의 주파수 응답비교)

  • 박정호;송석천;이상렬
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.798-801
    • /
    • 2000
  • For the performance enhancement of communication system, high quality filters are required. Also a minimization of size of filter is required for the interation of devices in the limited area. Conventional metal filters made of copper can be substituted by high quality high temperature superconducting(HTS) films for better performance. Hairpin type filters have been designed with the center frequency 14 GHz for the size reduction. 3-pole and 4-pole filters centered at 14 GHz with the bandwidth of about 300 MHz were designed and fabricated. With the simulation results, the frequency responses showed low insertion loss and sharp skirts characteristics. The frequency response of HTS 14 GHz fi1ter was measured at 77 K and compared with the simulation results. We have compared YBCO filters and copper filters which were made with the same design rules. Simulated and measured frequency responses reveal that HTS YBCO hairpin type bandpass filters show better performance than copper filters.

  • PDF

A study on the reduction of ac loss of YBCO coated conductor by a mechanical striation method (기계적으로 분할된 YBCO 선재의 교류손실 감소에 대한 연구)

  • Yoo, Yong-Su;Hong, Gye-Won;Lee, Hee-Gyoun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • High temperature superconductor (HTS) coated conductors has high hysteretic magnetization loss which is an obstacle for the AC applications of coated conductors. We propose a method to reduce the magnetization loss of the coated conductor. It is the mechanical striation method by load variety using office knife. The magnetization loss measured in the mechanical striated YBCO coated conductor without copper layer was compared with the loss generated by perpendicularly exposed external magnetic filed. The reduction in magnetization loss due to the mechanical striation is clearly shown at higher field and was dependent on the striation number. The mechanical striation method was proven to have additional advantages of a low cost and high fabrication process.

Analysis on the Hot-spot Temperature Location of a 24MVA Cast Resin Transformer by FEM (FEM을 이용한 24MVA 몰드변압기의 Hot-spot 위치 분석 연구)

  • Kim, Yong-Bae;Ha, Jung-Woo;Shin, Pan-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.26-32
    • /
    • 2012
  • This paper calculates the core and copper losses as heating sources of a 24MVA cast resin transformer, and analyzes the thermal distribution of the transformer to find out its hot-spot area by FEM program. Since the winding of the transformer is composed with many series and parallel circuits, the analyzing model of the winding is simplified and modelled by axi-symmetric domain. As the results, the maximum temperature is estimated by $137^{\circ}C$ in the upper part of the low-voltage winding. The maximum temperature has discrepancy of approximately $10^{\circ}C$, which is able to be considered as an acceptable error range in the design stage of power transformers. For the overall pattern of the temperature distribution is almost same as test results, the analyzing method can be a useful tool to find out a hot-spot area of the winding.

The Challenges of Diagnosing and Following Wilson Disease in the Presence of Proteinuria

  • Khan, Soofia;Schilsky, Michael;Silber, Gary;Morgenstern, Bruce;Miloh, Tamir
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.19 no.2
    • /
    • pp.139-142
    • /
    • 2016
  • The coexistence of Wilson disease with Alport syndrome has not previously been reported. The diagnosis of Wilson disease and its ongoing monitoring is challenging when associated with an underlying renal disease such as Alport syndrome. Proteinuria can lead to low ceruloplasmin since it is among serum proteins inappropriately filtered by the damaged glomerulus, and can also lead to increased urinary loss of heavy metals such as zinc and copper. Elevated transaminases may be attributed to dyslipidemia or drug induced hepatotoxicity. The accurate diagnosis of Wilson disease is essential for targeted therapy and improved prognosis. We describe a patient with a diagnosis of Alport syndrome who has had chronic elevation of transaminases eventually diagnosed with Wilson disease based on liver histology and genetics.

Characteristics Analysis of a Novel Segmental Rotor Axial Field Switched Reluctance Motor with Single Teeth Winding

  • Wang, Bo;Lee, Dong-Hee;Lee, Chee-Woo;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.852-858
    • /
    • 2014
  • A novel 12/10 axial field switched reluctance motor (AF-SRM) is proposed for cooling fan applications in this paper. Unlike from conventional structures, the proposed motor uses the axial field instead of the radio field, the rotor is constructed from a series of discrete segments, and the stator poles are constructed from two types of stator poles: exciting and auxiliary poles. This concept improves the torque capability of a previous design by reducing the copper volume, which leads to a higher efficiency. To verify the proposed structure, the finite element method (FEM) and Matlab-Simulink are employed to get characteristics of the proposed SRM. Finally, a prototype of the proposed motor was tested for characteristic comparisons.

The Properties of $Bi_2Mg_{2/3}Nb_{4/3}O_7$ Thin Films Deposited on Copper Clad Laminates For Embedded Capacitor (임베디드 커패시터의 응용을 위해 CCL 기판 위에 평가된 BMN 박막의 특성)

  • Kim, Hae-Won;Ahn, Jun-Ku;Ahn, Kyeong-Chan;Yoon, Soon-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.45-45
    • /
    • 2007
  • Capacitors among the embedded passive components are most widely studied because they are the major components in terms of size and number and hard to embed compared with resistors and inductors due to the more complicated structure. To fabricate a capacitor-embedded PCB for in-line process, it is essential to adopt a low temperature process (<$200^{\circ}C$). However, high dielectric materials such as ferroelectrics show a low permittivity and a high dielectric loss when they are processed at low temperatures. To solve these contradicting problems, we studied BMN materials as a candidate for dielectric capacitors. processed at PCB-compatible temperatures. The morphologies of BMN thin films were investigated by AFM and SEM equipment. The electric properties (C-F, I-V) of Pt/BMN/Cu/polymer were evaluated using an impedance analysis (HP 4194A) and semiconductor parameter analyzer (HP4156A). $Bi_2Mg_{2/3}Nb_{4/3}O_7$(BMN) thin films deposited on copper clad laminate substrates by sputtering system as a function of Ar/$O_2$ flow rate at room temperature showed smooth surface morphologies having root mean square roughness of approximately 5.0 nm. 200-nm-thick films deposited at RT exhibit a dielectric constant of 40, a capacitance density of approximately $150\;nF/cm^2$, and breakdown voltage above 6 V. The crystallinity of the BMN thin films was studied by TEM and XRD. BMN thin film capacitors are expected to be promising candidates as embedded capacitors for printed circuit board (PCB).

  • PDF

Galvanic Sensor System for Detecting the Corrosion Damage of the Steel in Concrete

  • Kim, Jung-Gu;Park, Zin-Taek;Yoo, Ji-Hong;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.118-126
    • /
    • 2004
  • The correlation between sensor output and corrosion rate of reinforcing steel was evaluated by laboratory electrochemical tests in saturated $Ca(OH)_2$ with 3.5 wt.% NaCl and confirmed in concrete environment. In this paper, two types of electrochemical probes were developed: galvanic cells containing of steel/copper and steel/stainless steel couples. Potentiodynamic test, weight loss measurement, monitoring of open-circuit potential, linear polarization resistance (LPR) measurement and electrochemical impedance spectroscopy (EIS) were used to evaluate the corrosion behavior of steel bar embedded in concrete. Also, galvanic current measurements were conducted to obtain the charge of sensor embedded in concrete. In this study, steel/copper and steel/stainless steel sensors showed a good correlation in simulated concrete solution between sensor output and corrosion rate of steel bar. However, there was no linear relationship between steel/stainless steel sensor output and corrosion rate of steel bar in concrete environment due to the low galvanic current output. Thus, steel/copper sensor is a reliable corrosion monitoring sensor system which can detect corrosion rate of reinforcing steel in concrete structures.

Study on Transport Current Properties of HTS cable connected with SFCL by using YBCO Thin Film type wire (YBCO 박막형 선재를 이용한 초전도 전류제한기의 연계에 따른 고온 초전도 케이블의 사고전류 통전 특성에 관한 연구)

  • Lee, Dong-Hyeok;Kim, Yong-Jin;Han, Byeong-Seong;Du, Ho-Ik;Han, Sang-Cheol;Lee, Jeong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.43-43
    • /
    • 2010
  • HTS(High Temperature Superconductor) cable has a high possibility of practical use due to the possibility of low voltage and high capacity transmission caused by its lower power loss than copper cable. On the other hand, when fault current occurred, resistance increase caused by superconductivity loss, the amount of power supplies has diminished, furthermore, it's necessary to take the possible danger of damage to HITS cable into account. Therefore, an effective plan for dealing with the above problem is to link HITS cable to SFCL. In this study, we researched the possibilities of normal transport current as well as the safety of HITS cable by analyzing the properties of transport current in HITS cable connected with SFCL.

  • PDF