• Title/Summary/Keyword: Low contrast concentration

Search Result 195, Processing Time 0.027 seconds

Evaluation of the Low Tube Voltage in the Computed Tomography Scan Technique using a Low Concentration Contrast Agent (저농도 조영제를 사용한 CT검사에서 저관전압 기법에 따른 유용성 평가)

  • Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.71-79
    • /
    • 2016
  • The purpose of this study is computed tomography contrast agent at low concentrations and low tube voltage technique to evaluate the usefulness on the phantom image. By varying the degree of mixture by the contrast medium concentration it was inserted in phantom. It was taken by changing the tube voltage and tube current step by step, and to evaluate the dose and the CT value obtained from the phantom image. As a result, low-contrast, low tube voltage(300 mgI/ml, 100 kV) was reduced by an average 21%(CTDIvol; computed tomography dose indexvol) more standard condition(350 mgI/ml, 120 kV). SNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 12.2(26%) 6.2(17%). CNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 11.5(32%), 6.3(26%). Research work on the CT scan is necessary in a variety of studies on the low contrast concentration and low tube voltage techniques for dose reduction and reducing of side effects the contrast agent.

Photovoltaic Characteristics of Low-density Concentration GaAs Solar Cells with/without Anti-reflective Coating

  • Noh, Sam Kyu;Kim, Jong Soo;Kim, Jin Soo;Yu, Jae Su
    • Applied Science and Convergence Technology
    • /
    • v.23 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • We have studied photovoltaic characteristics of single-junction GaAs solar cells with/without an $MgF_2/ZnS$ anti-reflective coating (ARC) illuminated by low-density concentration (<10 suns). By the ARC deposition, the short-circuit current density ($J_{SC}$) and the fill factor (FF) are increased by $5mA/cm^2$ and 5% at a standard illumination (1 sun), respectively, and the resulted conversion efficiency is enhanced by 45%. In contrast with the cell with no ARC showing a rapid degradation with increasing concentration power, the efficiency of ARC-deposited cell remains almost constant as ($17.7{\pm}0.3$)% regardless of the concentration. It informs that ARC treatment is very effective in GaAs concentrator solar cells.

A Study on Combustion And Exhaust Emissions of Diesel Engine -For Gas Oil-Water Emulsified Fuel- (디젤 기관의 연소와 배출물에 관한 연구 -경유-물물의 유화연료 사용시-)

  • 조진호;김형섭;박정률
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.180-188
    • /
    • 1992
  • By means of the compatibility according to solving environmental pollution and energy problem due to the emissions of NOx and smoke from diesel engine this paper experimentally inspected the effect of using emulsified fuel, gas oil-water, for combustion characteristic, that is combustion pressure, pressure rise rate, heat generating rate, the period of ignition delay and specific fuel consumption, and CO, HC, NOx concentration and smoke density. When using emulsified fuel, as a water addition rate was increased, combustion pressure, pressure rise rate and heat generating rate was increased, the period of ignition delay was lengthening, the specific fuel consumption was some what increased in contrast to diesel fuel in low load, but deceased in high load region. And NOx concentration was decreased, CO concentration was increased in low load, but decreased in high load region, HC concentration was increased in contrast to diesel fuel in all region.

Comparison of Contrast-Enhanced T2 FLAIR and 3D T1 Black-Blood Fast Spin-Echo for Detection of Leptomeningeal Metastases

  • Park, Yae Won;Ahn, Sung Jun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.86-93
    • /
    • 2018
  • Purpose: Imaging plays a significant role in diagnosing leptomeningeal metastases. However, the most appropriate sequence for the detection of leptomeningeal metastases has yet to be determined. This study compares the efficacies of contrast-enhanced T2 fluid attenuated inversion recovery (FLAIR) and contrast-enhanced 3D T1 black-blood fast spin echo (FSE) imaging for the detection of leptomeningeal metastases. Materials and Methods: Tube phantoms containing varying concentrations of gadobutrol solution were scanned using T2 FLAIR and 3D T1 black-blood FSE. Additionally, 30 patients with leptomeningeal metastases were retrospectively evaluated to compare conspicuous lesions and the extent of leptomeningeal metastases detected by T2 FLAIR and 3D T1 black-blood FSE. Results: The signal intensities of low-concentration gadobutrol solutions (< 0.5 mmol/L) on T2 FLAIR images were higher than in 3D T1 black-blood FSE. The T2 FLAIR sequences exhibited significantly greater visual conspicuity scores than the 3D T1 black-blood sequence in leptomeningeal metastases of the pial membrane of cistern (P = 0.014). T2 FLAIR images exhibited a greater or equal extent (96.7%) of leptomeningeal metastases than 3D T1 black-blood FSE images. Conclusion: Because of its high sensitivity even at low gadolinium concentrations, contrast-enhanced T2 FLAIR images delineated leptomeningeal metastases in a wider territory than 3D T1 black-blood FSE.

Preferred Skin Color Reproduction of Digital Image by Ink-jet Printer (잉크젯 프린터에 의한 디지탈 이미지의 바람직한 피부 색재현)

  • 서봉우
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.14 no.2
    • /
    • pp.37-49
    • /
    • 1996
  • The practical lith developer is a hydroquinone solution of moderate alkalinity and low free-sulfite ion concentration with potassium bromide as the restraining agent. In the study on composition of ilth developer to promote high sensitivity, high contrast and long term preservation or use, a new composition of lith developer, namely PK lith developer, was developed and of was found that PK lith developer was superior to the lith developer which was commercially available in terms of contrast, speed and preservation. This paper also describes studies on the addition of hdydrazine to PK lith developer, which have led to further improvements in the system.

  • PDF

Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography

  • Kim, Sang Youn;Cho, Jeong Yeon;Lee, Joongyub;Hwang, Sung Il;Moon, Min Hoan;Lee, Eun Ju;Hong, Seong Sook;Kim, Chan Kyo;Kim, Kyeong Ah;Park, Sung Bin;Sung, Deuk Jae;Kim, Yongsoo;Kim, You Me;Jung, Sung Il;Rha, Sung Eun;Kim, Dong Won;Lee, Hyun;Shim, Youngsup;Hwang, Inpyeong;Woo, Sungmin;Choi, Hyuck Jae
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1119-1129
    • /
    • 2018
  • Objective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose ($5.73{\pm}4.04$ vs. $8.43{\pm}4.38mSv$) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ${\geq}3$), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.

Perfusion MR Imaging in Gliomas: Comparison with Histologic Tumor Grade

  • Sun Joo Lee;Jae Hyoung Kim;Young Mee Kim;Gyung Kyu Lee;Eun Ja Lee;In Sung Park;Jin-Myung Jung;Kyeong Hun Kang;Taemin Shin
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • Objective: To determine the usefulness of perfusion MR imaging in assessing the histologic grade of cerebral gliomas. Materials and Methods: In order to determine relative cerebral blood volume (rCBV), 22 patients with pathologically proven gliomas (9 glioblastomas, 9 anaplastic gliomas and 4 low-grade gliomas) underwent dynamic contrast-enhanced T2*-weighted and conventional T1- and T2-weighted imaging. rCBV maps were obtained by fitting a gamma-variate function to the contrast material concentration versus time curve. rCBV ratios between tumor and normal white matter (maximum rCBV of tumor / rCBV of contralateral white matter) were calculated and compared between glioblastomas, anaplastic gliomas and low-grade gliomas. Results: Mean rCBV ratios were 4.90°±1.01 for glioblastomas, 3.97°±0.56 for anaplastic gliomas and 1.75°±1.51 for low-grade gliomas, and were thus significantly different; p < .05 between glioblastomas and anaplastic gliomas, p < .05 between anaplastic gliomas and low-grade gliomas, p < .01 between glioblastomas and low-grade gliomas. The rCBV ratio cutoff value which permitted discrimination between high-grade (glioblastomas and anaplastic gliomas) and low-grade gliomas was 2.60, and the sensitivity and specificity of this value were 100% and 75%, respectively. Conclusion: Perfusion MR imaging is a useful and reliable technique for estimating the histologic grade of gliomas.

  • PDF

Maximum TE Setting Range for Quantitatively Evaluating T2 Relaxation Time : Phantom Study (T2 이완시간의 정량적 평가에 있어서 Maximum TE의 설정 범위에 대한 연구 : 팬텀연구)

  • Park, Jin Seo;Kim, Seong-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.25-31
    • /
    • 2018
  • This study aimed to evaluate the range of maximum TE that could measure T2 relaxation time accurately by setting diverse maximum TE with using contrast medium phantoms. Contrast medium phantoms ranging from low to high concentrations were made by using Gadoteridol. The relaxation time and relaxation rate were compared and evaluated by conducting T2 mapping by using reference data based on various TEs and data obtained from different maximum TEs. It was found that accurate T2 relaxation time could be expressed only when the maximum TE over a certain range was used in the section with long T2 relaxation time, such as the low concentration section of saline or gadolinium contrast medium. Therefore, the maximum TE shall be longer than the T2 relation time for accurately maturing the T2 relaxation of a certain tissue or a substance.

EFFECTS OF ATMOSPHERIC WATER AND SURFACE WIND ON PASSIVE MICROWAVE RETRIEVALS OF SEA ICE CONCENTRATION: A SIMULATION STUDY

  • Shin, Dong-Bin;Chiu, Long S.;Clemente-Colon, Pablo
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.892-895
    • /
    • 2006
  • The atmospheric effects on the retrieval of sea ice concentration from passive microwave sensors are examined using simulated data typical for the Arctic summer. The simulation includes atmospheric contributions of cloud liquid water and water vapor and surface wind on surface emissivity on the microwave signatures. A plane parallel radiative transfer model is used to compute brightness temperatures at SSM/I frequencies over surfaces that contain open water, first-year (FY) ice and multi-year (MY) ice and their combinations. Synthetic retrievals in this study use the NASA Team (NT) algorithm for the estimation of sea ice concentrations. This study shows that if the satellite sensor’s field of view is filled with only FY ice the retrieval is not much affected by the atmospheric conditions due to the high contrast between emission signals from FY ice surface and the signals from the atmosphere. Pure MY ice concentration is generally underestimated due to the low MY ice surface emissivity that results in the enhancement of emission signals from the atmospheric parameters. Simulation results in marginal ice areas also show that the atmospheric and surface effects tend to degrade the accuracy at low sea ice concentration. FY ice concentration is overestimated and MY ice concentration is underestimated in the presence of atmospheric water and surface wind at low ice concentration. In particular, our results suggest that strong surface wind is more important than atmospheric water in contributing to the retrieval errors of total ice concentrations over marginal ice zones.

  • PDF

A Study on Clinical Hematology of Korean Cattle Resident in High-land (고지사육한우(高地飼育韓牛)의 임상혈액학적연구(臨床血液學的硏究))

  • Lee, Bang Whan;Ko, Kwang Du
    • Korean Journal of Veterinary Research
    • /
    • v.15 no.2
    • /
    • pp.161-176
    • /
    • 1975
  • In order to evaluate the epizootiological influence of high-land on cattle feeding, routine hematological observation, with additional examinations of feces and general clinical condition, was conducted comparing the high-land cows resident at altitude of 800 to 1,200 meters in Daegwanryeong to the low-land cows resident at altitudes of less than 100 meters in Samcheok and Gangneung. The high-land cows were divided into 3 groups such as group A, B and C, consisting of 15, 16 and 20 adult cows respectively, and among the 3 groups only group C was exposed to abrupt high-land cold before observation. The low-land cows, that is group D, were consisted of 25 adult cows. The results obtained in the survey were summarized as follows: 1. Number of erythrocytes, concentration of hemoglobin and packed cell volume were remarkably higher (p<0.01) in all of 3 groups (group A, B and C) of high-land cows than trios of low-land cows (group D). These higher values in high-land cows were ascribable to the better feeding and hygienic management, and lesser infestation of small-type Piroplasma (Theileria) and internal parasites in contrast with the low-land cows. 2. Remarkably higher value of mean corpuscular volume (p<0.01) and a tendency to lower value of mean corpuscular hemoglobin concentration were noted in group D in contrast with group A, B and C. The reason was attributed to the higher infestation (p<0.01) of smalltype piroplasma in low-land cows in contrast with high-land cows. 3. It was noticiable that even though lesser infestation of small type Piroplama in the highland cows was shown, a natural case of clinical small-type-piroplasmosis was found in high-land group B as well as a case in the low-land group D. The blood Pattern showed characteristic macrocytic-hypochromic-anemia with increased reticulocytes in both two cases (Table 7). 4. In the observation of leukocytic series, marked increase of eosinophils in group D was seen in accordance with heavy infestation of gastrointestinal nematodes, and increased neutrophils with higher appearance of nonlobulated form and eosinopenia in group C only was observed suggesting the leukocytic response to the cold exposure in high-land. 5. Mean values of thrombocytes in group A,B,C and D were 48.4, 40.7, 42.7 and $32.3{\times}10^4/mm^3$ respcetively, and no statistically significant differences were observed.

  • PDF